• Title/Summary/Keyword: Insulation level

Search Result 341, Processing Time 0.033 seconds

Analysis of the Edge Sealing Strength for Vacuum Glass Panel Using Design of Experiment (실험계획법을 이용한 진공유리 패널 모서리 용융 접합 강도실험 분석)

  • Kim, Seung-Jong;Jeon, Euy-Sik
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.4
    • /
    • pp.1819-1824
    • /
    • 2014
  • The vacuum-glazing panel is a panel that keeps two glasses completely sealed in a vacuum condition. It is the high function insulation material of having the wall level minimizing the heat loss by the conduction and convection heat transmission coefficient. The edge sealing is a very important process of vacuum glass on the strength, thickness and air tightness. In this study, by using the hydrogen mixture gas torch, two sheets of glass was sealing in the furnace. The thickness and strength of the glass according to the process parameters is measurement and analysis, and predicting the edge sealing strength of glass by using taguchi method of experiment. We verified the validity of the experiment by checking the error rate through additional experiment.

Development and Verification of Thermal Control Subsystem for High Resolution Electro-Optical Camera System, EOS-D Ver.1.0 (고해상도 전자광학카메라 EOS-D Ver.1.0의 열제어계 개발 및 검증)

  • Chang, Jin-Soo;Kim, Jong-Un;Kang, Myung-Seok;Yang, Seung-Uk;Kim, Ee-Eul
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.921-930
    • /
    • 2013
  • Satrec Initiative successfully developed and verified a high-resolution electro-optical camera system, EOS-D Ver.1.0. We designed this system to give improved spatial and radiometric resolution compared with EOS-C series systems. The thermal control subsystem (TCS) of the EOS-D Ver.1.0 uses heaters to meet the opto-mechanical requirements during in-orbit operation and uses different thermal coatings and multi-layer insulation (MLI) blankets to minimize the heater power consumption. Also, we designed and verified a refocusing mechanism to compensate the misalignment caused by moisture desorption from the metering structure. We verified the design margin and workmanship by conducting the qualification level thermal vacuum test. We also performed the verification of thermal math model (TMM) by comparing with thermal balance test results. As a result, we concluded that it faithfully represents the thermal characteristics of the EOS-D Ver.1.0.

Characterization and Evaluation of Worker s Exposure to Airborne Glass Fibers in Glass Wool Manufacturing Industry (유리섬유 단열재 제조업 근로자의 공기중 유리섬유 폭로 특성 및 평가 방법에 관한 연구)

  • 신용철;이광용;박천재;이나루;정동인;오세민
    • Journal of Environmental Health Sciences
    • /
    • v.22 no.2
    • /
    • pp.43-57
    • /
    • 1996
  • To characterize worker's exposure to glass fibers, to find the correlation between airborne total dust concentrations and fiber concentrations and to recommend an appropriate evaluation method for worker's exposure to fibrous dusts in glass wool industry, we carried out this study. Average respirable fiber levels at five factories were 0.013-0.056 f/cc, and fairly below the OSHA PEL, 1 f/cc. A factory showed the lowest airborne fiber level, 0.013 f/cc, which was different significantly from those of other factories of which average fiber concentration was 0.046 f/cc. The cutting and grinding operations of insulation products resulted in higher airborne fiber cocentrations than any other processes(p<0.05). To characterize airborne fiber dimension, fiber length and diamter were determined using phase contrast microscope. The geometric means of airborne fiber lengths were $42-105 \mu m$. One factory had airborne fibers whose length distribution(GM = $105 \mu m$) was different from those of other factories(GM = $42-50 \mu m$). The percentages of respirable fibers less thinner than 3 gm were 38.9-90.9% at four factories, and two factories of them had the higher percentages than others. The findings explain for variation of airborne fiber diameters between factories. On the other hand, between the processes were the difference of fiber-length distributions observed. The cutting and grinding operations showed shorter fiber-length distributions than the fiber forming one. However, fiber-diameter distributions or respirable fiber contents were similar in all processes. The airborne fiber concentrations and the dust concentrations had relatively weak correlation(r=0.25), thus number of fibers couldn't be expected reliably from dust amount. Fiber count is appropriate for assessing accurate exposures and health effects caused by fibrous dusts including glass fibers. Ministry of Labor have established occupational exposure limit to glass fibers as nuisiance dust, but should establish it on the basis of respirable fiber concentration to provide adequate protection for worker's health

  • PDF

Predicting Noise inside a Trimmed Cavity Due to Exterior Flow (외부 유동에 의한 흡차음재 공간내의 소음 예측)

  • Jeong, ChanHee;Ganty, Bastien;Choi, EuiSung;Cho, MunHwan
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.04a
    • /
    • pp.466-471
    • /
    • 2014
  • The interior vehicle noise due to the exterior aerodynamic field is an important topic in the acoustic design of a car. The air flow detached from the A-pillar and impacting the side windows are of particular interest as they are located close to the driver / passenger and provides a lower insulation index than the trimmed car body parts. This paper presents a numerical analysis method for a simplified vehicle model. The internal air cavity including trim component are included in the simulation. The car body includes the windshield and two side windows. The body is made of aluminum and trimmed with porous layers. The methodology proposed in this paper relies on two steps: the first step involves the computation of the exterior flow and turbulence induced non-linear acoustic field using PowerFlow. The second step consists in the computation of the vibro-acoustic transmission through the window using the finite element vibro-acoustic solver Actran. Additionally in order to validate the numerical process, an experimental set-up has been created based on the simplified vehicle. The vibration of the windshield and windows, the total wind noise level results and the relative contributions of the different windows are then presented and compared to measurements. The influence of the flow yaw angle (different wind orientation) is also assessed.

  • PDF

A Study on The Comparison of Mechanical Property Between The Staggered Stud Wood Wall and The Standard Wood Frame Wall (일반벽체와 교호 샛기둥 벽체의 역학적 성능 비교 연구)

  • Shim, Jae-Kwang;Kim, Gwang-Chul
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.640-649
    • /
    • 2017
  • A comparative research on the traditional standard wood walls and other light-frame wood walls is necessary to expand the base of wooden buildings and improve consumer satisfaction. Therefore, in this research we looked for new possibilities through comparison of performance between standard wood wall and newly presented staggered stud wood wall. First, the strength characteristics of staggered stud wood walls were evaluated and the those of standard wood walls were compared. The ultimate load of the standard wall was larger than that of the staggered stud wood wall, because the cross section of the wood making up the standard wood wall was larger than that of the staggered stud wood wall. However, the statistical analysis between the two groups didn't showed a significance of 95% confidence level. This means that, staggered stud wood walls have shown the possibility of replacing the standard wood wall. Because the cross-section of the stud in the staggered stud wood walls is smaller than that of the standard wall, the material can be saved. Therefore, staggerd wood stud wall is judged to be more economical than the standard wall. In addition, since the area of the insulation also increases, improvement of the heat bridge is also expected.

The Development of a Retirement Home Model with Emphasis on Clothing, Nutrition, Housing, and Psychological Dimension (노인의 의.식.주생활 및 심리적 적응을 위한 이상적 모델개발 연구 -양로원을 중심으로-)

  • 윤복자
    • Journal of the Korean Home Economics Association
    • /
    • v.27 no.4
    • /
    • pp.167-191
    • /
    • 1989
  • The present study was conducted to devlop and appropriate retirement home model for the elderly in terms of clothing and textiles; nutrition, health, and foodservice; housing and environment; and psychological adaptation. Specifically, the purposes of the study were: 1) to provide basic guidelines for clothing by comparing the clothing behavior of the elderly living in the retirement home and those living in their own homes with family, 2) to provide basic guidelines for balanced diet and effective foodservice, 3) to develop an ideal life space and facilities, and 4) to assess the psychological characteristics of the elderly. Questionnaires, observation, experimental method, and survey of literature were used for the study. Clothing behavior showed that the elderly were much concerned about clothing, and they preferred comfortable as well as fashionable designs. The elderly in the retirement homes complained of a lack of quantity and variety in clothing. They preferred natural fiber rather than blended fabrics. Flame resistance, thermal insulation, and flexibility of textile fabrics were found to be prime considerations in manufacturing and selecting clothing materials for the elderly. The health status of the surveyed elderly was generally good, but some poor eating habits were observed. Dietary nutrients intakes were generally sufficient, but several nutrients intakes were insufficient. The level of equipment in the kitchens of the institutions was low. Furthermore, the employment rate of dietitians in institutional settings was extremely low. This resulted in a lack of systematic foodservice management. Residents in the institution were generally satisfied with present life space and facilities but this was mainly because of abandonment, adaptation, and past experience. Optimal allocation of residents per bedroom and an adequate design for storage, bathroom, utility room, and dining room were recommended. The comparison of psychological status of the elderly living at home was more stable than those living in an institution. The emotional state of the elderly living in the institution was characterized by loneliness; they did not have close interpersonal relationships or future plans. An appropriate model for the elderly was developed on the basis of these findings.

  • PDF

Spectro-electrochemical Analyses of Immobilization of Glucose Oxidase (Glucose Oxidase 고정화에 대한 전기화학적/광학적 분석)

  • Kim, Hyun-Cheol;Cho, Young-Jai;Gu, Hal-Bon;SaGon, Geon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.316-319
    • /
    • 2000
  • In the case of immobilizing of glucose oxidase into polypyrrole (PPy) using electrosynthesis, the glucose oxidase (GOx) forms a coordinate bond with the polymer's backbone. However, because of intrinsic insulation and net-chain of the enzyme, the charge transfer and mass transport are obstructed during the film growth. Therefore, the film growth is dull. We synthesized the enzyme electrode by electropolymerization added some organic solvent, A formative seeds of film growth is delayed by adding the solvent. The delay is induced by radical transfer between the solvent and pyrrole monomer. In the case of adding ethanol, the radical transfer shares the contribution of dopant between electrolyte anion and GOx polyanion. This may lead to increase amount of immobilized the enzyme in ppy. However, adding tetrahydrofuran (THF), the radical transfer is more brisk, resulting in short chained polymer. Therefore, the doping level is lowered and then amount of immobilized of enzyme is decreased. For the UV absorption spectra of synthetic solution before synthesis and after, in the case of ethanol added, the optical density was slightly decreased for the GOx peaks. It suggests amount of GOx in the solution was decreased and amount of GOx in the film was increased. We established qualitatively that amount of immobilization can be improved by adding a little ethanol in the synthetic solution. It is due to radical transfer reaction. The radical transfer shares the contribution of dopant between small and fast electrolyte anion and big and slow GOx polyanion.

  • PDF

Noise Reduction Method for Environment Friendly Housing Estate (신도시 친환경 주거단지조성을 위한 소음저감 대책방안)

  • 김흥식;주문기;주시웅
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.535-541
    • /
    • 2004
  • For housing estate of a new administrative capital city, Noise reduction method is a important design factor. As measuring a noise level of traffic noise according to separation from road, it can be created a quite housing estate. Analyzing of merits and demerits in sound barrier walls and tunnels can be proposed environment friendly soundproofing facilities. Number of measurement was performed to know what kind of layout of housing estate is good for noise reduction. Through this measurement, ㄷ shaped layout or parallel layout has the advantage of sound insulation rather than right angled layout. In this case (ㄷ shaped layout or parallel layout) buildings neighboring to the road should be designed to insulate sound. Evergreen trees should be planted between housing estate and road more than 30m (at least 7~8m) in order to reduce noise and have masking effects. If broad-leaved trees are planted more than 30m, approximately 10dB noise is reduced and 2~4dB if 7~8m. Roads in the estate should be designed considering pedestrians first, and special roads for moving and ambulance should be designed as skew road, if possible. The result shows that 15$^{\circ}$-sloped‘S’road reduces 1~2dB noise and 30$^{\circ}$-sloped road reduces 4~7dB. If noise barrier is inevitably installed, it should be designed to go well wit neighboring environment so as to install Environment Friendly Noise Barrier using materials and trees including wood and soil. Through this study the results are used to guideline for construction of environment friendly housing estate

  • PDF

Linearity Verification of Measured Voltage Deterioration of High Voltage Cable based on Weibull Lifetime Index (와이불 수명지수에 의한 고전압 케이블의 전압열화 측정값의 선형성 확인)

  • Um, Kee-Hong;Lee, Kwan-Woo
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.227-232
    • /
    • 2016
  • As the demand for electric power increases, all devices operating in power stations and all devices adopted in order to deliver distant loads need to be operating in perfect condition at the level of reliability expected by consumers. In general, the lifetime of cables used in delivering high power is declared to be 30 years from the time of production. Deterioration (which is the worsening of electric properties) starts from the very moment of operation. In spite of the reduction in reliability caused by deterioration, the reality is that cables often operate at considerable risk of accidents because the reliability of operation has not been diagnosed. We have invented a device to diagnose the deterioration processes of high-voltage power cables. It has been installed and is currently operating at Korea Western Power Co., Ltd., located in Chungnam, Korea. In previously published papers we have shown graphs obtained by plotting insulation resistances versus time, through analyzing the data extracted from operating cables using the devices we have invented. In this paper, we verify that the previously plotted graphs agree with the life time index of Weibull distribution of probability.

Study on Adiabatic Performance of LNG Storage Tank for Vehicles (차량용 LNG연료용기의 단열성능에 관한 연구)

  • Han, Jeong-Ok;Lee, Young-Won
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.31-35
    • /
    • 2008
  • Natural gas vehicles are being applied to city buses for improving air quality in metropolitan and have proved the effective way to reduce the pollutant emissions. Liquified Natural Gas(LNG) has also attempted a vehicle fuel in order to raise the fuel storage density that is a disadvantage of Compressed Natural Gas(CNG). This paper described insulation characteristic of a LNG storage tank. From the results, adiabatic coefficient of a tested tank was around $40J/h{\cdot}^{\circ}C{\cdot}m^2$ and it was the lower level than gas safety regulation limit. Two experimental methods were adopted to justify the evaluation results and they were revealed that the results were very similar to each other. Also, through testing relief valve operation characteristic it was investigated venting amount of boiled off gas.

  • PDF