• Title/Summary/Keyword: Insulation level

Search Result 341, Processing Time 0.027 seconds

A Study on the Directions of Sustainable Architecture for Dwelling Planning (지속가능한 주거건축계획의 방향에 관한 연구)

  • 김성화
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 1994.10a
    • /
    • pp.31-38
    • /
    • 1994
  • The purpose of paper is to suggest directions of sustainable Architecture for dwelling planning. It deals with foreign example regading recycling Architecture in the point of using natural reources and energy effectively and minimizing environmental wastes. The methods which can be applied to Korean dwelling planning are as follows : 1) To use the underground space of apartments as pubilc energy-saving facility 2) To use conservatory passive solar systems at south-facing balconies of apartments 3) To flow daylight into the staircase of single-family house 4) To construct compactly doors and windows which have high-level insulation with high insulated walls and ventilation systems 5) To recycle materials such as steel, wood and soil 6) To recycle space according to the change of uses 7) To make users participate actively when we plan for dwelling.

  • PDF

A Study on the Directions of Sustainable Architecture for Dwelling Planning (지속가능한 주거건축계획의 방향에 관한 연구 - 문헌 고찰을 통한 사례연구를 중심으로 -)

  • 김성화
    • Journal of the Korean housing association
    • /
    • v.6 no.2
    • /
    • pp.77-86
    • /
    • 1995
  • The purpose of paper is to suggest directions of sustainable Architecture for dwelling planning. It deals with foreign examples regarding recycling Architecture in the point of using natural resources and enerty effectively and minimizing environmental wastes. The methods which can be applied to Korean dwelling planning are as follows : 1) To use the underground space of apartments as public energy-saving facility 2) To use conservatory passive solar systems at south-facing balconies of apartments 3) To flow daylight into the staircase fo single-family house 4) To construct compactly doors and windows which have high-level insulation with high insulated walls and ventilation systems 5) To recycle materials such as steel. wood and soil 6) To recycle space according to the change of uses 7) To make users participate actively when we plan for dwelling.

  • PDF

A Survey on Foreign and Domestic Interior Noise Criteria for Walls and Floors (공동주택 내부소음 기준과 바닥 및 벽체 차음성능 기준 고찰)

  • Kim, Sun-Woo;Song, Min-Jeong
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.37-44
    • /
    • 2004
  • In this study, foreign and domestic noise criteria on walls, floors, and water supply facilities were reviewed and the results are as follows : regulation can be divided two things, one is on thickness the other is sound insulation performance. Green Building regulation based on the law and this have sound classification systems. Since these regulations are not established in Korea. The noise regulation on water supply-drain facilities and domestic guideline on interior noise level is needed. Foreign regulations are stricter than those of ours. And those has sound classification system for the better acoustic condition of inhabitants'.

Evaluation of Insulating Reliability in Epoxy Composites

  • Park, No-Bong;Yang, Dong-Bok;Lim, Jung-Kwan;Park, Yong-Pil;Lee, Hee-Kab;Kim, Gui-Yeul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07b
    • /
    • pp.1200-1203
    • /
    • 2003
  • The dielectric breakdown of epoxy composites used for transformers was experimented and then its data were applied to Weibull distribution probability. First of all, speaking of dielectric breakdown properties, the more hardener increased, the stronger breakdown strength became at low temperature because of cross-linked density by the virtue of ester radical. The breakdown strength of specimens with filler was lower than it of non-filler specimens because it is believed that the adding filler forms interface and charge is accumulated in it, therefore the molecular motility is raised and the electric field is concentrated. In the case of filled specimens with treating silane, the breakdown strength become much higher. Finally, according to Weibull distribution analysis, reducing breakdown probability of equipment insulation lower than 0.1% level requires the allowable field allowable field intensity values to be kept under 21.5 MV/cm.

  • PDF

The Noise property and Its improvement of the Turbo Compressor (터보압축기의 소음특성 및 개선방안)

  • Chun, Kwang-Wook;Shin, Bum-Sik;Choi, Yeon-Sun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.282-287
    • /
    • 2009
  • In this paper, 3-stage centrifugal turbo compressor was measured and analyzed numerical simulation for find noise source and was reduced noise with changing designs. For this purpose, it was measured noise level and was analyzed noise frequency at each stage. In order to Find where is noise source, the study was investigated about structure borne noise by using modal analysis and also was checked sound radiation and leakage of noise at inlet and outlet by result of sound intensity. In order to reduce of noise, sound insulation rings were maded and were adhered at joint and noise reduction effects were verified by measurement and numerical simulation. From the analysis results of leakage of noise, this study presented new joint designs, also it was verified by result of numerical simulation.

  • PDF

Cabin Noise Reduction using Unit Cabin Mock-up of High Value Ship (고부가가치선의 Unit Cabin Mock-up 을 이용한 캐빈소음 저감 연구)

  • Joo, Won-Ho;Song, Keun-Bok
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2010.05a
    • /
    • pp.483-484
    • /
    • 2010
  • Unit cabin means room, which is installed in the high value ship such as drill ship and FPSO, after pre-assembled. In order to develop the noise control design for a unit cabin, a variety of acoustic tests such as sound absorption, transmission, and radiated noise measurements were carried out by using the mock-up of living quarter. From the tests, it was found out that the combined noise level of a unit cabin could be dominated by the radiated noise from wall panel in low frequency range and the design guidelines for the noise control of unit cabin were fully established, such as the improvement of sound transmission loss between the cabin and corridor, and radiated cabin noise reduction.

  • PDF

The Lightning Current Parameters that Impact on the Surge Analysis of the EHV Gas Insulated Substation by EMTP

  • Shim Eung-Bo;Han Sang-Ok
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.1
    • /
    • pp.1-7
    • /
    • 2005
  • This paper describes the lightning surge analysis model of extra high voltage GIS using EMTP. Various lightning current parameters were investigated in order to confirm the impact on the lightning surge analysis such as lightning current amplitude, waveform, size of GIS, tower footing resistance and surge arresters. The multi-story tower model and EMTP/TACS model were introduced for the simulation of dynamic arc characteristics. The margin between the maximum overvoltage and BIL of the GIS was about 10 percent and the margin between the maximum overvoltage and BIL of the transformer was 21 percent.

Electrical Strength of the Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck-Kweon;Kim, Chung-Hyeok;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Song, Min-Jong;Lee, Joon-Ung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.11a
    • /
    • pp.149-150
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of unfilled epoxy and filled epoxy in $LN_2$ was analyzed. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.

  • PDF

A Study on the Characteristics of Propagation and Attenuation of Piling Noise by SIP Method with Casing (Casing 부착 SIP공법에 의해 발생하는 항타소음의 전달 및 감쇠특성에 관한 연구)

  • 이병윤;윤해동;조원희;김재수
    • Journal of KSNVE
    • /
    • v.9 no.5
    • /
    • pp.899-905
    • /
    • 1999
  • Construction equipment noise has caused much annoyance for a number of dwellers in nearby construction field and has become a very serious issure in our living environment. Therefore, in our country, a practical solution and a better method of reducing construction equipment noise are highly required in construction field. Practical solutions for the construction equipment noise, however, are very difficult because of the poorness of basic data and insufficiency of the existing research. Especially, in order to establish the sound insulation plan about pilling works noise with high sound pressure level and impactive, a real situation of sound characteristics about the noise of pilling works in foundation work demands more detail investigation. In this point, this study attempts to survey the characteristics of attenuation and propagation of construction equipment noise in pilling work using SIP(soil-cement injected precast pile) method with casing. And this study intends to get the basic data for establishment of a standard about construction noise.

  • PDF

A Study on the Acoustic Performance Indication Standards of Apartment Housing Performance Grade Indication System (공동주택 성능등급 표시제도 상의 음성능 표시기준 고찰)

  • Yang, Kwan-Seop;Kim, Kyoung-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.1252-1255
    • /
    • 2006
  • The government has enforced Housing Performance Grade Indication System (Article 21, Paragraph 2 of Housing Act) starting January 2006 for the purpose of giving users in hope of toying an apartment opportunities to select housing based on personal preferences by providing information on housing performance at the time of tenant recruitment announcement as well as securing desirable environment (comfort) by encouraging construction companies to build housing of the indicated performance level. The acoustic performance indication items include three items such as floor impact isolation performance(light weight impact sound, heavy weight impact sound), bathroom noise and insulation performance of boundary walls between households. This paper explains the background, the basis of creation and evaluation method focused on the acoustic environment performance helping for the developer of technique and a staff in charge of construction business who cope with this system.

  • PDF