• 제목/요약/키워드: Insulation level

검색결과 341건 처리시간 0.033초

공동주택 중량바닥충격음 현장측정을 통한 차단성능 평가방법의 비교검토 연구 (A Study of Rating Method Comparison for Heavy-weight Floor Impact Sound based on the Field Test Data in Apartment Houses)

  • 신훈;백건종;국찬;송민정;김선우
    • KIEAE Journal
    • /
    • 제10권5호
    • /
    • pp.187-194
    • /
    • 2010
  • Heavy-weight floor impact sound insulation performance criteria have been effective in Korea since the regulation which enforces the standard thickness of slabs in domestic apartment houses should be constructed by 180mm or 210mm was adopted. But every slab does not satisfy this criteria. So, review on existing floor impact sound insulation performance is needed to propose some basic materials for the revision of rating method. To achieve this goal, 63 field test data were checked and analyzed. The results of this study are as follows ; 1) The 210mm thickness slab has the characteristics of deeper level decrease above 120Hz frequency band than that of 180mm thickness slab's. 2) 27.5% of 180mm thickness slabs were satisfied the floor impact sound insulation performance criteria, whereas 65% of 210mm slabs do. 3) Among the main contribution frequency bands for the determination of single rating index, 63Hz was shown as the most contributive band in 210mm slabs. 4) In comparison of single rating index between bang machine test and ball test. there is a big difference between the two and this phenomenon is frequent in 210mm slab results. 5) Rating Methods for the analysis of cross-correlation between the amount of rating, the usefulness of the arithmetic mean could be secured.

단열바닥기초 적용을 위한 발포유리 골재의 기초 특성 평가 (A Study on the Basic Properties of Foam Glass Aggregate for the Application of Insulated Foundation)

  • 김상헌;문수영;김현수
    • 한국건설순환자원학회논문집
    • /
    • 제10권4호
    • /
    • pp.420-427
    • /
    • 2022
  • 본 연구는 국내 생산 발포유리 골재를 활용하여 단열바닥기초로 활용하기 위해, 발포유리 골재로 구성된 단열부의 물리역학적 특성 및 열적특성을 평가하였다. 평가 결과, 압축강도는 기존 유기단열재인 XPS, EPS 등에 비해 높은 40.6 N/cm2로 나타났으며, 열전도율은 0.84 W/mK로 나타났다. 또한 단열바닥구조를 모사한 시험체의 열관류율은 0.37 W/m2K로 나타나 실제 발현되는 발포유리 골재의 열전도율은 0.80 W/mK으로 평가되었다. 본 연구를 통해 발포유리 골재를 사용한 단열바닥구조의 활용가능성을 확인할 수 있었다.

학교주변 소음실태 분석에 관한 연구 -원주지역 학교를 중심으로- (A Study of Analysis on the Noise Aspect of School District -A Case Study of Wonju City-)

  • 가종길;이준대
    • 한국안전학회지
    • /
    • 제14권3호
    • /
    • pp.140-145
    • /
    • 1999
  • In this study, noise analyses were performed toward ten school and one library-building adjacent to road. In particular, noise levels measured in the case-study city were compared to those from environmental noise standard as well as to encouraged noise level. In the analyses, the following conclusions are emphasized in order to make comfortable educational learning environment. 1) When windows were open, the measured noise level of 9 schools exceeded the encouraged noise level. In order to mitigate the exceeded level, it is necessary to plant trees or lawn and install soundproofing wall. 2) When windows were closed, the measured noise level of the most schools showed lower than that of encouraged level. For sound insulation, installing both double window and casement window are required. 3) Schoolhouse's vertical arrangement from the road in order to minimize the expected noise effect, and provision of green space by which visual hiding as well as psychological comfort are presumably achieved.

  • PDF

바닥충격음 차단성능 평가방법의 상호비교 (Comparison of Rating Methods for the Floor Impact Sound Insulation Performance)

  • 김경우;최현중;양관섭;이승언
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.291-294
    • /
    • 2005
  • In this study, we compared and analyzed the floor impact sound insulation performance produced by the rating methods. The rating methods are using reversed A-weighting curve, A-weighted sound pressure levels and arithmetic average. On-site floor impact sound pressure levels of living room and room are measured. The results of this study are 1)the rating using reversed A-weighting curve for heavy-weight impact sound's standard deviation is lower than that of light-weight impact sound, 2)the number of rating using A-weighted sound pressure levels and arithmetic average is larger than that of using reversed A-weighting curve, and 3)the number of rating using reversed A-weighting curve mainly depends on impact sound pressure level of 63Hz in heavy-weight impact sound.

  • PDF

소규모 공간에서의 잔향시간 영향요인 분석 (Analysis of the Factors affecting Reverberation Time in Small Room)

  • 김명준;이병기
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.492-497
    • /
    • 2006
  • This study gives the results of the measurements and analysises of the reverberation times in a small room such as apartment houses. We measured the RT by changing measurement conditions, which were sound sources. sound source's positions, receiving point & height, sampling time and so on. The critical factor affecting reverberation time was sound source in unoccupied houses and the reverberation time differences between result of RT using impulsive and interrupted sound source was 0.3sec at 500Hz frequency. And the difference of RT due to sound sources affected the sound insulation such as apparent sound reduction index and sound level difference about 1dB at each frequency in unoccupied houses.

  • PDF

건설현장 소음저감을 위한 건설장비용 방음덮개 개발 (A Development of Sound Encloser for Breaker to reduce Construction Noise)

  • 장재희;정재국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.177-182
    • /
    • 2000
  • This study aims to provide an effective method to reduce construction noise generated by breakers. To reduce the breaker's noise level, a sound encloser was developed; the sound insulation's performance was tested in the field. From the field test, the following results were obtained. The sound insertion loss was about 6.5dB(A), even though part of the sound encloser for the breaker was left unclosed. This is equal to the reduction value which can be obtained by using more expensive low noise breakers, proving that there are more effective measures for sound insulation at lower cost. The characteristic of frequency was evaluated to show an even reduction through all frequency bands, except 630Hz.

  • PDF

피뢰기 적용에 따른 다양한 배전계통의 뇌과전압 변화특성 (Lightning Overvoltage Characteristics in Distribution System with Arrester Application)

  • 김상국;정채균;이종범;하동혁
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.355-357
    • /
    • 2002
  • Distribution lines are spanned on a much large area as compared to transmission lines, and therefore, are more often susceptible to lightning strokes. The selection of the proper value of basic insulation level(BIL), for particular insolation components of distribution structures in specific, is very important. Lightning strikes has current risetimes ranging from 0.1 to several $\mu s$ and can produce transient overvoltages substantially greater than the BIL of many distribution systems in spite of lightning arresters. This paper describes lightning overvoltage of a 22.9kV distribution system due to lightning strike. This study will provide the information on insulation coordination studies to adopt BIL.

  • PDF

A Simple Metric for Assessing the Severity of Partial Discharge Activity Based on Time-Sequence-Analysis-Discharge Level Patterns

  • Stewart Brian G;Yang Lily;Judd Martin D;Reid Alistair;Fouracre Richard A
    • Transactions on Electrical and Electronic Materials
    • /
    • 제7권6호
    • /
    • pp.313-318
    • /
    • 2006
  • This paper introduces a partial discharge (PD) severity metric, S, based on the evaluation of time-sequence PD data capture and resulting Time-Sequence-Analysis Discharge (TSAD) level distributions. Basically based on an IEC60270 measurement technique, each PD event is time stamped and the discharge level noted. By evaluating the time differences between a previous and subsequent discharge, a 3D plot of time-sequence activity and discharge levels can be produced. From these parameters a measurement of severity, which takes into account dynamic or instantaneous variations in both the time of occurrence and the level of discharge, rather than using standard repetition rate techniques, can be formulated. The idea is to provide a measure of the severity of PD activity for potentially measuring the state of insulation within an item of plant. This severity measure is evaluated for a simple point-plane geometry in $SF_{6}$ as a function of gap distance and applied high voltage. The results show that as the partial discharge activity increases, the severity measure also increases. The importance of future investigations, quantifications and evaluations of the robustness, sensitivity and importance of such a severity measurement, as well as comparing it with typical repetition rate assessment techniques, and other monitoring techniques, are also very briefly discussed.

EFFECT OF HEAT CURING METHODS ON THE TEMPERATURE HISTORY AND STRENGTH DEVELOPMENT OF SLAB CONCRETE FOR NUCLEAR POWER PLANT STRUCTURES IN COLD CLIMATES

  • Lee, Gun-Che;Han, Min-Cheol;Baek, Dae-Hyun;Koh, Kyung-Taek
    • Nuclear Engineering and Technology
    • /
    • 제44권5호
    • /
    • pp.523-534
    • /
    • 2012
  • The objective of this study was to experimentally investigate the effect of heat curing methods on the temperature history and strength development of slab concrete exposed to $-10^{\circ}C$. The goal was to determine proper heat curing methods for the protection of nuclear power plant structures against early-age frost damage under adverse (cold) conditions. Two types of methods were studied: heat insulation alone and in combination with a heating cable. For heat curing with heat insulation alone, either sawdust or a double layer bubble sheet (2-BS) was applied. For curing with a combination of heat insulation and a heating cable, an embedded heating cable was used with either a sawdust cover, a 2-BS cover, or a quadruple layer bubble sheet (4-BS) cover. Seven different slab specimens with dimensions of $1200{\times}600{\times}200$ mm and a design strength of 27 MPa were fabricated and cured at $-10^{\circ}C$ for 7 d. The application of sawdust and 2-BS allowed the concrete temperature to fall below $0^{\circ}C$ within 40 h after exposure to $-10^{\circ}C$, and then, the temperature dropped to $-10^{\circ}C$ and remained there for 7 d owing to insufficient thermal resistance. However, the combination of a heating cable plus sawdust or 2-BS maintained the concrete temperature around $5^{\circ}C$ for 7 d. Moreover, the combination of the heating cable and 4-BS maintained the concrete temperature around $10^{\circ}C$ for 7 d. This was due to the continuous heat supply from the heating cable and the prevention of heat loss by the 4-BS. For maturity development, which is an index of early-age frost damage, the application of heat insulation materials alone did not allow the concrete to meet the minimum maturity required to protect against early-age frost damage after 7 d, owing to poor thermal resistance. However, the combination of the heating cable and the heat insulating materials allowed the concrete to attain the minimum maturity level after just 3 d. In the case of strength development, the heat insulation materials alone were insufficient to achieve the minimum 7-d strength required to prevent early-age frost damage. However, the combination of a heating cable and heat insulating materials met both the minimum 7-d strength and the 28-d design strength owing to the heat supply and thermal resistance. Therefore, it is believed that by combining a heating cable and 4-BS, concrete exposed to $-10^{\circ}C$ can be effectively protected from early-age frost damage and can attain the required 28-d compressive strength.

공동주택 수음실의 평면형태에 따른 중량충격음 특성 변화 연구 (A Study on the Heavy Impact Sound Insulation Performance of Apartments depending on the Shape of Receiving Room)

  • 기노갑;김항;최은석;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1317-1320
    • /
    • 2006
  • This study compared the floor impact sound level of rectangular receiving room type to differed receiving room types to analyze effect of room mode. The floor impact sound level of master room were higher than the level of living room which resulted from room mode. The result showed that the level of low frequency bandwidth in the location varied with receiving room types were lower than general measuring point of rectangular receiving room.

  • PDF