• Title/Summary/Keyword: Insulation effect

Search Result 736, Processing Time 0.029 seconds

The Effect of Rare-Earth Additives on Dielectric Properties of X7R MLCC Composition (X7R용 적층 칩 세라믹 캐패시터 조성의 희토류 첨가에 따른 유전 특성)

  • 이석원;윤중락
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12
    • /
    • pp.1080-1086
    • /
    • 2003
  • Effects of E$_2$O$_3$. HO$_2$O$_3$ and Dy$_2$O$_3$ addition on dielectric properties of non-reducible BaTiO$_3$ based X7R dielectrics with Ni electrode have been studied in a reduced atmosphere. As the content of rare-earth with E$_2$O$_3$. HO$_2$O$_3$, Dy$_2$O$_3$ was less than 3wt%, The TCC(Temperature Capacitance Change) and insulation resistance characteristics were improved by compensate the oxygen vacancies due to occupy either the Ba or Ti site. We developed the composition of X7R (EIA standard) for higher capacitance MLCC which had high reliability electric properties by the addition of Er ion into BaTiO$_3$ + MgO + Y2O$_3$ + MnO + (Ba$\sub$0.4/Ca$\sub$0.6/)SiO$_3$ composition.

Improvement of surface insulation properties of engineering thermoplastics by using nano/micro composite (나노/마이크로 컴포지트를 이용한 엔지니어링 열가소성 플라스틱의 표면 절연 개선)

  • Jung, Eui-Hwan;Lim, Kee-Joe;Hur, Jun;Jeong, Jong-Hun;Kim, Pyung-Jung;Jeong, Su-Hyun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.29-29
    • /
    • 2010
  • Engineering plastics have excellent electrical properties, mechanical strength and various characteristic which include chemical resistance, environmental resistance, weatherability at a wide temperature range. It has good characteristic(light weight, good productivity) as compare with epoxy or porcelain insulators. However, engineering plastics not suited to outdoor insulator because it isn't hydrophobic. Therefore, to over come these critical problems, we improve the surface insulation characteristics of engineering plastic by coating micro-, nano- size inorganic fillers added to RTV-SIR(Room temperature vulcanized-silicone rubber) at this plastic surface. The effect is analyzed through salt-fog test, tracking test. In conclusion, the engineering plastic coated RTV with micro-$Al_2O_3$20[phr], nano-Al(OH)3 1 ~ 3[phr] improved much better than the others.

  • PDF

Investigation on Thermal and Mechanical Characteristics of HDPE Mixed EVA Applied for Power Cable Insulation (전력 케이블 절연재 적용을 위한 HDPE/EVA 혼합수지의 열적, 기계적 특성 고찰)

  • Lee, Han-Joo;Jung, Eui-Hwan;Yoon, Jae-Hoon;Lim, Kee-Joe;Lee, Hung-Kyu
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.85-85
    • /
    • 2010
  • In this paper, each specimen blended at weight proportions of 80% HDPE to 20% EVA, 70% HDPE to 30% EVA, 60% HDPE to 40% EVA, and 50% HDPE to 50% EVA was manufactued respectively. FE-SEM, DSC and XRD analysis were carried out as the means of structural and chemical analysis. From the results of DSC and XRD analysis, the lower contents in blended specimens were, the higher melting temperature and crystallinity of main crystal were. It seems that the phenomena was attributes to themoplastic interpenetrating network effect(TPIPN) in which EVA having low melting point penetrated into HDPE. Also, from the decreasing tendeancy of melting point as a function of blend ration, it was confirmd that above resins have compatibility. The thermal and mechanical performance of proposed insulator were compared with conventional XLPE, main insulating material of CV cable. Also, validity was proved by superior and inferior factor respectively.

  • PDF

A Study on the Improvement of the Floor Impact Sound Insulation Performance in Wall Slab Type Apartment (벽식구조 공동주택의 바닥충격음 개선에 대한 연구)

  • Kim, Sun-Woo
    • KIEAE Journal
    • /
    • v.12 no.1
    • /
    • pp.73-81
    • /
    • 2012
  • Floor impact sound has been most annoying for years among the noises which are produced in apartment. This study aims to analyze the improvement of floor impact sound by comparing the results of the test which was carried out for the wall slab type apartment and moment frame apartment, and also for the effect of advanced vibration isolation layer. Moment frame structure that main structure consists of column and slab has shown better performance for the heavyweight impact sound comparing with wall slab type structure which is general type in Korea. Stiffness of floor system was raised by reinforcing the stiffness of vibration isolation layer, and it was analyzed how much the floor impact sound performance was improved. The result showed that the reinforced floor had better performance than the existing floor system that uses lightweight porous concrete as vibration isolation material. In addition, a system used wire mesh in mortar showed improvement of floor impact sound than a system without wire mesh, and better performance for the frequency bands lower than 160 Hz which causes floor impact problem in wall slab type apartment.

The Noise Reduction Effect by the Enclosure of Gas Turbines (가스터빈 차폐막의 소음 저감효과에 관한 연구)

  • Park, Dae Hun;Shin, Yoo In;Park, Sung Gyu;Kim, Kang Il;Song, Chul Ki
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.34 no.4
    • /
    • pp.287-292
    • /
    • 2017
  • A gas turbine is the main equipment used in a combined heat and power plant. It generates a high sound pressure noise level. To reduce the noise level, an enclosure is installed around the turbine. The sound insulation performance of the enclosure affects the amount of external noise reduction. In this study, a sound transmission loss analysis is performed using the boundary element method to predict sound insulation performance according to the numbers and shapes of the supporter. Radiated noise analysis is also performed for the main external points of the enclosure using ray-acoustics. The results of these analyses are presented and a design plan is proposed that reduces the sound pressure noise level of the enclosure.

Effects of Various Factors on the Energy Consumption of Korean-Style Apartment Houses (한국형 아파트의 냉난방 에너지에 미치는 제 인자의 영향)

  • 유호선;현석균;홍희기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.11
    • /
    • pp.972-980
    • /
    • 2002
  • This work is aimed at estimating the effects of various factors on the energy consumption of Korean-style apartment houses using TRNSYS. The factors considered here include the nominal size of floor area, type of remodeling, azimuth, sidewall insulation, and window type. Based on some assumptions, an actual apartment house is simplified into a model that is used for thermal load calculations. The simplified model is validated by showing a good agreement with the actual one in the predicted result. Remodeling balconies into unconditioned buffer spaces yields a favorable thermal performance in comparison with the original type regardless of the nominal size. Incorporating balconies into a conditioned indoor space leads to sharp increases in thermal loads, which must be avoided in view of energy conservation as well as structural problem. A quantitative assessment on the azimuthal effect indicates that the heating energy can be saved up to 16% by taking the south or southeast direction. Reduction in the heating load with enhancing the sidewall insulation is gradual, so that a cost-effectiveness analysis may be needed when amending the regulations concerned. Glazing appears to significantly affect the heat transfer through window. A typical case illustrates that the heating load is decreased about 25% by simply adopting triple glazing instead of double glazing.

An Experimental Study on the Effects of a Radiation Shield on the Thermal Load of a Cryochamber (복사 차폐막이 극저온 용기의 부하에 미치는 영향에 관한 실험적 연극)

  • Kim, Young-Min;Park, Seong-Je;Kang, Byung-Ha
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.365-370
    • /
    • 2005
  • Infrared (lR) detectors are widely used for such applications as thermoelstic stress analysis, medical diagnostics and temperature measurement. Infrared detectors commonly need to be refrigerated below 80 K, and thus a cooling system should be equipped together with the detector system. The cooling load, which should be removed by the cooling system to maintain the nominal operating temperature of the detector, critically depends on the insulation efficiency of the cryochamber housing the detector. Cryochamber considers the conduction heat transfer through a cold finger, the gases conduction and radiation heat transfer. The thermal loads of an infrared detector Cryochamber with radiation shield are investigated experimentally in present study. Since the effect of radiation heat transfer on thermal loads is significant, radiation shields is installed in the cold finger part to protect heat input through radiation. It is found that the thermal load can be substantially reduced by increasing the number of radiation shield.

  • PDF

THEORY OF BACKGROUND NOISE CANCELLATION ON PREDICTION OF RESPONSE PROBABILITY DISTRIBUTION FOR AN ARBITRARY SOUND WALL SYSTEM AND ITS APPLICATION TO ACTUAL SOUND WALL SYSTEMS

  • Ohta, M.;Takaki, N.
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1994.06a
    • /
    • pp.740-745
    • /
    • 1994
  • In the actual situation of measuring the environmental noise, it is very often that only the resultant phenomenon fluctuation contaminated by the additional noise of arbitrary distribution type can be observed. Furthermore, the observed data is usually given in a sound level form the purpose of estimating only the undisturbed objective output response, some estimation method is necessary to reasonably remove the effect of the above additional noise. In this paper, first, a mathematical model of arbitrary sound insulation systems is introduced in the form of a linear system on intensity scale, by using the well-known additive property of energy quantities. Next, some estimation method of the output response under the existence of background noise is derived. Then, based on the expression of the above estimation method, a new prediction method of only the output response probability function form for arbitrary sound insulation systems without. a background noise is proposed by use of observed data contaminated by a background noise. Finally, the effectiveness of the proposed method is confirmed experimentally too by applying it to the actual various type sound wall systems.

  • PDF

The Effect of Heat Curing Methods on the Temperature History of the Fly Ash Concrete Subjected to Extremely Low Temperature (복합보온양생 방법이 극저온 조건하 플라이애시 치환 콘크리트의 온도이력에 미치는 영향)

  • Han, Min-Cheol;Son, Ho-Jung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.7 no.3
    • /
    • pp.85-90
    • /
    • 2012
  • In this study, temperature profile of the fly ash concrete were studied in accordance with the change of heating curing method combination for the slab concrete in order to develop efficient protection method of the concrete subjected to $-20^{\circ}C$. The slab concretes with the size of $1200mm{\times}600mm{\times}200mm$ were fabricated with W/B of 50% and exposed to $-20^{\circ}C$ for 7 days. Five different combinations of heat curing methods were applied to the slab concrete specimen; two combinations of heat supplying by electrical heater and surface heat insulation material such as polyethylene film and quadrupled layer bubble sheet based on heat enclosure installment; three combinations of heating coil embedment and surface heat insulation materials such as polyethylene film, sawdust and quadrupled layer bubble sheet based on heat enclosure installment. Test results showed that by applying both heating coil and bubble sheet and heat enclosure, the concrete exposed to $-20^{\circ}C$ can be effectively protected from early-age frost damage.

  • PDF

Synthesis and Properties of High Voltage Silicone Rubber by Platinum-based Flame Retardant

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.7 no.6
    • /
    • pp.283-292
    • /
    • 2006
  • So that high-strength and electrical properties apply by excellent high voltage insulator electricity material, ATH content and platinum-based flame retardant that influence in flame retardant and tracking characteristic among composite of silicone rubber studied mechanical strength and influence getting to electrical properties. Composition of ${\alpha}$, ${\omega}-vinyl$ poly (dimethyl-methylphenyl) siloxane(VPMPS) of a polymer quantity made doing mole of D4, $D3^{Me,Ph}$ and VMS by 1000:15:0.2 mole ratio and uses basic catalyst tetramethylammonium silanolate(TMAS) and do opening equilibrium polymerization to be used to main polymer for high voltage insulation insulator. Control ATH content and content of platinum-based flame retardant and made high voltage insulation silicone rubber. Measured mechanical strength of making silicone rubber using UTM, and tracking characteristic according to standard of IEC 60587, flame retardant test studied effect that flame retardant characteristic gets in tracking characteristic, measuring according to UL94V method of test.