• Title/Summary/Keyword: Insulation effect

Search Result 737, Processing Time 0.036 seconds

HFPD Analysis Using Fractal and Statistical Methods (프랙탈 및 통계적 방법을 이용한 HFPD 분석)

  • Jung, Young-Ill;Lim, Yong-Bae;Kim, Duck-Keun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.927-930
    • /
    • 2002
  • The HFPD measurement method is a technique to analyze aging state of high voltage insulation materials and detect higher frequency signals than conventional PD measurement method therefore it takes less noise effect and could execute active line measurement. It is possible to analyze main discharge phenomena and obtain access to aging progress occurred in insulation materials through accumulation of HFPD signals during determined interval and expression of fractal dimension using statistical process of accumulated signals. In this study, the statistical parameters (skewness & kurtosis) and fractal dimensions are changed by discharge patterns that is shown up different characteristics with applied voltages and times.

  • PDF

Properties Electric of AIN Thin Film on the Si and GaAs Substrate (Si와 GaAs기판 위에 AIN 박막의 전기적 특성)

  • Park, Jung-Cheul;Chu, Soon-Nam;Kwon, Jung-Youl;Lee, Heon-Yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.1
    • /
    • pp.5-11
    • /
    • 2008
  • To study the effects of $H_2$ gas on AIN insulation thin film, we prepared AIN thin film on Si and GaAs substrate by means of reactive sputtering method using $H_2$ gas as an additives, With treatment conditions of $H_2$ gas AIN thin film shows variable electrical properties such as its crystallization and hysterisis affected to electrical property, As a results, AIN thin film fabricated on Si substrate post-treated with $H_2$ gas for 20 minutes shows much better an insulation property than that of pre-treated, And AIN film treated with $H_2$ gas comparing to non-treated AIN film shows a flat band voltage decreasment. But In GaAs substrate $H_2$ gas does not effect on the flat band voltage.

The Study on Treeing under the Temperature Variation in Low Density Polyethylene Mixed with Dodecyl Alcohol (Dodecyl Alcohol이 첨가된 P.E에서 온도변화에 따른 Treeing에 관한 연구)

  • Lee, Chang-Hee;Lee, Kye-An;Kim, Sang-Jun;Kim, Jung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 1989.11a
    • /
    • pp.75-78
    • /
    • 1989
  • Insulation of P.E insulated cable under the field of high-voltage will be breakdown ultimately due to the degradation process called 'Treeing' which is generated in the insulation, so long as any counter-measure suppressing or eliminating it could not be provided. In this paper as a counter-measure Dodecyl Alcohol is mixed with P.E and Treeing under the temperature variation has been observed. Results show that the larger weight ratio of Dodecyl Alcohol is stronger the effect of suppressing Tree ing in the range from room temperature to 40$^{\circ}C$ and generated Treeing has been soon eliminated and it never again generated.

  • PDF

Temperature History of the Wall Concrete Subjected to -10℃ depending on Heat Curing Method (-10℃ 조건에서의 보온양생방법 변화에 따른 벽체 콘크리트의 온도이력)

  • Han, Sang-Yoon;Son, Ho-Jung;Cheong, Sang-Hyun;Ahn, Sang-Ku;Han, Cheon-Goo;Han, Min-Cheol
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.255-256
    • /
    • 2011
  • This study investigates the effect of a curing condition on the temperature history and strength development of concrete under -10℃. Combination of various curing methods was applied, i.e. a conventional form was combined with compressed insulation, heat panel and heat cable. Results showed that the concrete cured by a single use of a conventional form resulted in serious deterioration of early strength development. However, other concretes cured by the proposed curing methods maintained the temperature of the concretes between 5 and 20℃, and thus resulted in no frost damage.

  • PDF

A Measurement of Switching Surge Voltage Using Inverter devices (인버터의 스위칭 서지전압 측정)

  • Kim, Jong-Gyeum;Jeong, Jong-Ho;Lee, Eun-Woong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.53 no.1
    • /
    • pp.14-21
    • /
    • 2004
  • Most adjustable-speed drives (ASDs) designed to operate low voltage induction motors incorporate voltage-source inverters (VSIs), which create motor voltages at high switching frequencies. The motor leads used to connect an ASD to a motor can behave like transmission lines for voltage pulses, which can be reflected at the motor terminals. The resulting oscillatory transient, known as the long-lead effect, can stress and consequently degrade the stator insulation system of a motor. This paper describes the results of tests to 1) determine the correlation between peak motor voltage and the length of motor leads and 2) determine the correlation between peak motor voltage and the switching frequency of the ASD Insulation failures like this usually are caused by voltage surges. Voltage surges are often the result of switching power circuits, lightning strikes, capacitor discharges and solid-state power devices.

The Analysis of Green Roof during the Summer by Numerical Method (모델을 이용한 하절기 옥상정원 해석)

  • Byun, Kihong
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.5
    • /
    • pp.51-62
    • /
    • 2016
  • The purpose of this paper is to study the effectiveness of a green roof by simple mathematical model. The developed model simulates a green roof during the summer. The results explain and support the claims in the literature such that effectiveness of a green roof depends on the climate condition, and on the insulation condition of the roof. If insolation can not be reduced more than 60% by the shading effects of a green roof, more active measures than green roof seem necessary. The analysis tools like presented in the paper is necessary especially to consider climate effect, to design, and also to test green roof.

Study on thermal performance of vacuum window with various low-ε coating glasses (저방사 코팅이 진공창의 열성능에 미치는 영향)

  • Cho, S.H.;Tae, C.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.300-311
    • /
    • 1997
  • A theoretical method was developed to analyze the effect of low-$\varepsilon$ coatings which have influence on thermal performance of vacuum windwo glazing and double pane glazing. The overall heat transfer coefficient(U) value and thermal performance were analyzed by theroretical method on various kins of windows. TRNSYS program was used to analyze total heating and cooling energy consumption on the model building which has various windows. As the result, better thermal insulation can be achieved on the vacuum window glazing than double pane glazing when low-$\varepsilon$ coating was done on the surface of glass. Total heating and cooling energy consumption was almost same on the double pane window glazing but was lessened on the vacuum window glazing when the window size of south direction increased. Therefore, low-$\varepsilon$ coating was very necessary for vacuum window glazing in order to improve thermal insulation performance and efficient energy conservation can be achieved by vacuum window glazing at the real building which has large window.

  • PDF

The Improvement of NGR for Power Transformer Open Circuit Protection (전력용변압기 단선 보호용 NGR 성능 개선)

  • Kang, Y.W.;Shim, E.B.;Kwak, J.S.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.83-88
    • /
    • 2004
  • As the electric system is getting larger to meet the increasing demand for electric power, the rating of power apparatus is becoming inevitably higher in its working voltage and larger in its capacity. According to KEPCO reports, power transformers in the KEPCO system have undergone troubles such as winding short insulation breakdowns every year since 1981. the cause of this troubles were high one line grounding fault currents in KEPCO systems that had direct grounding systems. KEPCO has installed the NGR(neutral grounding reactor) to lower this fault current and reduced winding short insulation breakdowns in power transformers. But when a circuit breaker opened a no load bus, some trips of circuit breakers for protecting transformer have occurred by mal-operation of 59GT(overvoltage ground relay) that detect disconnection of NGR. Therefore, in this paper, we analyzed the cause and examined the effect of time delav circuit to prevent wrong operation of 59GT.

  • PDF

Transient State Analysis in Case of Lightning Arrester Deterioration due to Lightning Surge (뇌서지로 인한 피뢰기 열화시 과도상태 분석)

  • Lim, Sung-Yong;Kim, Kyu-Ho;Rhee, Sang-Bong;Kim, Soo-Bae
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.276-277
    • /
    • 2015
  • As the effect of global warming continues, surge rates in Korea are also getting increased. Although there are devices to protect distribution line from the surge like lightning arrester, insulation of the lightning arrester can be destroyed if frequent surge occurs in distribution line. This paper assumed that the lightning surge hits the lightning arrester and make this device's insulation destroyed. This paper also simulated these processes utilizing EMTP/ATPDraw and verified voltage behavior when faults such as line to ground fault due to frequent lightning surge occur in lightning arrester.

  • PDF

The Aging Effects on Electrical Properties for the Irradiated EPDM (방사선을 조사한 EPDM에서 전기적 특성의 경년열화 효과)

  • 류부형
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.4
    • /
    • pp.78-87
    • /
    • 2000
  • The $\gamma$-ray irradiation and aging effects on electrical characteristics of $^{60}Co$ $\gamma$-ray irradiated ethylene-propylene-diene-terpolymer(EPDM) contained with 1 to 3phr phenolic and quinolinic antioxidants as antirads were investigated. The marked effects of type and amounts of the antioxidant on the volume resistivity and AC breakdown strength of the $\gamma$-ray irradiated EPDM are different. A phenolic antioxidant(IR 1010) contribute to improving the electrical insulation properties on the EPDM better than quinolinic antioxidant(Kumanox RD) during irradiation. In aging the irradiated EPDM specimens contained antioxidants at room temperature in air, it was shown a improvement of insulation properties due to radical scavenging and crosslinking of EPDM aged until 360 days.

  • PDF