GIS에 있어서 전기적 절연진단법에 대한 연구[1] (A Study on the Electrical Diagnostic Methods In GIS)

  • 최재구;김영배;김익수;이형호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.904-906
    • /
    • 1998
  • PD pulses have about one nanosecond rise time in the $SF_6$ gas insulation. These pulses propagate in the apparatus to PD sensors in the form of the voltage oscillation, high frequency current and the electromagnetic radiation. In this paper, we investigated the characteristics of two types of PD sensors, by putting high frequency signals in the form of sine waves and pulse into the test apparatus in air. Also, we measured PD quantity from the needle electrode and the sensitivity of the sensors. We found that PD of 70pC could be detected with this method and the study in $SF_6$ gas should be carried out for application to $SF_6$ GIS.

  • PDF

농촌주택 유형분석을 통한 재생우선순위 도출 (Selection of Priority for Revitalization by Analyzing Rural House Type)

  • 박길범;박준모;김옥규;방세라
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.174-175
    • /
    • 2014
  • A Rural house in Chungcheong area have been variety of matters, rapid deterioration of house and incomplete of maintenance control, that is represented lack of durability heating from lack of heat insulation property, health worsening form use of toxic substance and so on. For farmers who did not know where to repair and how to repair, they are urgently needed measures of standard and basis that is to realize a condition of rural house. Accordingly, this study drew major matters and priority for revitalization through analysis of type of rural house from research on the actual condition in order to develope of diagnostic criteria of rural house.

  • PDF

가스분석을 이용한 전력용 변압기 이상진단 연구 (A Study of the Preventive Diagnostic Algorithm of Gas Analysis in Oil for Power Transformer)

  • 최인혁;권동진;정길조;유연표;선종호;신명철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1676-1678
    • /
    • 2001
  • In general, power demand is on an increasing trend as industries have made rapid strides. Power transformer is the most important equipment in substation for this reason. Transformer trobles go with blackout, expensive repair costs and huge economic losses. Therefore it is important to find the quick detection of incipient fault for the least losses. There have been gas, partial discharge, temperature, OLTC, fan and pump diagnosis for preventive techniques by present. Specially gas analysis has been adapted for a long time and proved as confident method. In this paper, we analysed the fault causes of used power transformer. The insulation faults was occupied 40% of inquired 152 faults from 1991 to 2000. This study presents the developed algorithm and expert system for finding abnormal status within transformer. We used the Element Expert tool developed Neuron DATA Inc.

  • PDF

회전기 고정자 권선의 부분방전 측정용 RFCT 특성 (Characteristics of RFCT for Partial Discharge Measurement in the Stator Winding of Rotating Machines)

  • 강동식;윤대희;황돈하;김용주;장기찬;송상옥
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1616-1618
    • /
    • 2001
  • In recent the on-line partial discharge (PD) measurement using sensors, such as EMC, SSC, RTD and RFCT, as an indicator of stator winding insulation condition has been developed. RFCT sensor was placed arounding a grounding lead of surge capacitor to detecting PD. Trend of PD magnitude/phase angle/pulse number over time are useful parameter to diagnosis aging state. We have developed Radio Frequency Current Transformer(RFCT) sensor which is suitable for PD diagnostic measurement in 6.6kV rotating machines. In this paper, we describe the characteristics of RFCT sensor, such as frequency and PD magnitude using 6.6 kV model stator winding in Lab.

  • PDF

도시철도 변전소 절연진단 프로그램 기술 분석 (An Analysis on Technology of Urban Railway Substation Insulation Diagnostic Program)

  • 박현준;박영;정호성;김형철;유기선
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.116-116
    • /
    • 2010
  • This paper introduces an comprehensive monitoring and management program for implementation of a real-time monitoring system that monitors condition of urban railway AC/DC transformers, disconnecting switches, circuit breakers, regulators, and GIS (Gas Insulated Switchgear). Especially, the system is applied to diagnose the overall condition of urban railway substations by sending acquired data through an OPC server to a database, effectively storing and monitoring conditions simultaneously. The above system is a management based system and is also applicable to small-scale systems.

  • PDF

양수발전기 고정자 권선에서 운전중 및 정지중 부분방전 특성 (On-Line and Off-Line Partial Discharge Properties in the Pumped Storage Generator Stator Windings)

  • 김희동;주영호;윤대헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2089-2092
    • /
    • 1999
  • Partial discharge(PD) tests were performed both when the pumped storage generator(rated 13.8kV and 220MVA) was on-line and off-line. This generator has been equipped with 12 bus coupler sensors in directional mode. PD tests were conducted using partial discharge analyzer(PDA), partial discharge meter(PDM) and digital partial discharge detector. PDA showed that the patterns of the normalized quantity number(NQN) and the partial discharge magnitude are in accord with on-line and off-line. The insulation condition was estimated by diagnostic tests(off-line) such as PD magnitude and dissipation factor.

  • PDF

UHF 기술을 이용한 온라인 부분방전 모니터링 (On-line Insulation Diagnostic by PD Monitoring Field Practical of UHF Technique for On-line PD Monitoring)

  • 오용;최용성;황종선;이경섭
    • 전기학회논문지P
    • /
    • 제57권2호
    • /
    • pp.176-180
    • /
    • 2008
  • A field-oriented UHF system for on-line PD monitoring of transformers is designed, which has been installed inside the oil tank of transformer in a substation by two ways: on-line installing mode through the oil-valve and pre-installing mode through the man hole/hand hole cover. This system has successfully captured long intermittent discharge signals that hadn't been detected through conventional techniques, and solved the problem successfully. The results demonstrate that UHF technique has great advantages for on-line PD monitoring of transformers. By adopting the peak detection technique, it becomes easy and effective for the transplantation of the phase-resolved pattern recognition technique from conventional method to UHF method, and then to realize continuous on-line monitoring, source characterization and trending analysis.

가스분석을 이용한 변압기의 이상진단 알고리즘 연구 (A Study of the Preventive Diagnostic Algorithm of Gas in Oil for Power Transformer)

  • 최인혁;권동진;정길조;유연표;선종호;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.1903-1905
    • /
    • 2000
  • Power transformers have a tendency of ultra-high voltage capacity as power demand increases day after day KEPCO also will have plan to supply transmission power from 345KV to 765KV in the early of 2000. Therefore, the fault by insulation destruction gives rise to large area of power failure in huge capacity transformers. On-line predictive diagnostics is very important in power transformers because of economic loss and its spreading effect. This study presents the algorithm for transformer oil analysis used KEPCO code, IEC code, gas pattern method and Dornenburg & Roger Ratio method. We also describe the MMI display of expert system programmed by Element Expert Tool(Neuron Data Inc.).

  • PDF

대용량 유입변압기의 온라인 진단시스템 적용연구 (Field Test of On-line Monitoring System for Oil-filled Power Transformers)

  • 이창용;김용한;김남해;김정한;윤자홍;남극채
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1644-1646
    • /
    • 2003
  • This paper presents recent studies on the on-line insulation monitoring and diagnostic systems for transformers developed by HHI. Sufficiently high sensitivity and accuracy for practical use were achieved for the system, combined with communication networks to provide an on-line remote monitoring system. Several alarm criteria are formulated to enable a superimposed monitoring system to perform decisive action. The reasons for monitoring the condition and maintaining the health of electrical apparatus were discussed. The experience at the fields and the criteria for the judgment are also discussed in detail.

  • PDF

전력용 변압기 유중가스분석 결과와 동향 (A Result and Pattern of Dissolved Gases Analysis in Kepco)

  • 조성민;김재철;권동진;구교선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.95-96
    • /
    • 2007
  • Dissolved gas analysis (DGA) is one of the most widely used diagnostic tools for detecting and evaluating faults in electrical equipment. However, interpretation of DGA results is often complex and should always be done with care, involving experienced insulation maintenance personnel. KEPCO (Korea Electric Power Cooperation) has been using DGA technique since KEPCO established the criteria of DGA in 1985. In this paper, we introduce the DGA criteria of KEPCO and analyze the result of DGA. Also we sort pattern in result of DGA. Then, relation between pattern and inner inspection was studied. 67 DGA data was used for analyzing pattern. Some patterns have something to do with cause of incipient fault.