• Title/Summary/Keyword: Insulation degradation

Search Result 230, Processing Time 0.029 seconds

Invention Methodology of High Strength Insulated Steel Stud using TRIZ (강도향상형 단열스터드 개발을 위한 트리즈 기법 활용방안)

  • Cho, Bong-Ho;Kim, Sun-Sook;Kwak, Chai-Eun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.14 no.3
    • /
    • pp.33-41
    • /
    • 2013
  • This study used TRIZ methodology to develop a new steel stud for load bearing or non-load bearing walls. Technical contradiction of high strength with high insulation performance can be solved by TRIZ. We suppose a new shape of high-strength insulated (HSI) Stud. This study showed TRIZ can be usefully applied to the development of new construction materials by solving technical contradictions. Insulation performance of HSI stud can be improved approximately 12% compared to the standard KS stud. Although up to 3.9% of the flexural strength degradation is expected, compressive strength of HSI studs are improved from 4.1% to 8%. In conclusion, improved thermal performance and higher strength can be expected for the HSI stud developed using TRIZ.

The study of in-situ measurement method for wall thermal performance diagnosis of existing apartment (기존 공동 주택의 벽체 열성능 현장 측정법에 관한 연구)

  • Kim, Seohoon;Kim, Jonghun;Yoo, Seunghwan;Jeong, Hakgeun;Song, Kyoodong
    • KIEAE Journal
    • /
    • v.16 no.4
    • /
    • pp.71-77
    • /
    • 2016
  • Purpose : The energy saving in a residential building (apartment) sector is known as one of the effective solution of energy reduction. In South Korea, the government has recently reinforced regulations associated with the energy performance of buildings. However, there is a lack of research on the methods for the energy performance diagnosis that is used to analyze the wall thermal performance of the existing apartments. Because a reliable diagnosis is necessary to save the building energy, this study analyzed wall thermal performance of an existing apartment in Seoul. Method : This paper applied two methods for analysis of the thermal insulation performance; HFM(Heat Flow Meter) method and ASTR(Air-Surface Temperature Ratio) method. The HFM method is suggested by ISO9869-1 code to measure the thermal performance. The ASTR method is proposed by this study for the simplified In-situ measurement and it uses three temperature data (interior wall surface, interior and exterior air) and the overall heat transfer coefficient. This study conducted the experiment of an existing apartment in Seoul using these methods and analyzed the results. Furthermore, the energy simulation tool of the building was used to suggest retrofit of the building based on the results of measurements. Result : The error rate of HFM method and ASTR method was analyzed in about 17 to 20%. As the results of comparison between the initial design values of the wall and the measured values, the 26% degradation of insulation thermal performance was measured. Lastly, the energy simulation tool of the building shows 10.8% energy savings in accordance with the construction of suggested retrofit.

THE TRACKING CHARACTERISTICS BY THE DIFFERENT CROSSLINKED DENSITY OF SILICONE RUBBER MATERIAL USED FOR OUTDOOR INSULATION (옥외용 실리콘 고무재료의 가교도에 따른 내트랙킹 특성)

  • Kim, D.W.;Lee, C.Y.;Hong, J.Y.;Baek, J.H.;Lee, S.J.
    • Proceedings of the KIEE Conference
    • /
    • 1995.07c
    • /
    • pp.1058-1060
    • /
    • 1995
  • In this paper, we studied the tracking characteristics of silicone rubbers that differed in the degree of crosslinking. As the tracking method, we adopted ASTM D 2303 and Merry-Go-Round(MGR) test method. It was found that the higher the degree of crosslinking, the better tracking characteristics. In these two test methods, specimens showed similar tendency of performance variation according to the degree of crosslinking. However the degradation phenomena were very different. As for MGR method, only the color of specimens' surface changed without any erosion or tracking path on them. On the contrary, the specimens subjected to ASTM D 2303 test method showed severe erosion.

  • PDF

A Study on Insulation Degradation Properties of Thermal Conductive Silicone Rubber due to Temperature Transition (온도 변화에 의한 열전도성 실리콘 고무의 절연 열화 특성)

  • Lee, Sung Ill
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.7
    • /
    • pp.456-461
    • /
    • 2015
  • In this study, the frequency properties of electrostatic capacity and dielectric loss for the samples with different types of filler has been measured in through the applied frequency range of 7 kHz ~3,000 kHz at temperature of $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$. The results of this study are as follows. When the sample is degradated at the temperature of $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$ and the frequency range of 7 kHz ~3,000 kHz is applied, It found that the electrostatic capacity of the sample with Polyimide film is larger than the sample with Grass fiber. It found that the dielectric loss for the sample with Polyimide film is larger than the sample with Grass fiber with increasing frequency and temperature in the $80^{\circ}C$, $110^{\circ}C$, $140^{\circ}C$, $170^{\circ}C$ range. Also, the dielectric loss decreased with increasing frequency. In case of the sample with Polyimide film, It found that the electrostatic capacity decreased with increasing temperature, and the dielectric loss gradually decreased with increasing frequency.

A Study on the Process Analysis and the Risk Assessment for Removal Work of the Asbestos Cement Slate (석면 슬레이트 해체작업의 공정분석 및 위험성평가에 관한 연구)

  • Oh, Hyunsoo;Kim, Jeong-Min;Chang, Seong Rok
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.137-143
    • /
    • 2014
  • Asbestos is given to a variety of six naturally occurring silicate minerals. These minerals possess high tensile strength, flexibility, resistance to chemical and thermal degradation, and electrical resistance. These minerals have been used for decades in thousands of commercial products, such as insulation and fireproofing materials, automotive brakes, textile products, cement and wallboard materials. When handled, asbestos can separate into microscopic-size particles that remain in the air and are easily inhaled. It is now known that prolonged inhalation of asbestos fibers can cause serious and fatal illnesses including malignant lung cancer, mesothelioma, and asbestosis. Therefore the use of asbestos and asbestos products has dramatically decreased in recent years. Also all constructions including asbestos should be removed under strictly controlled conditions and very tightly implemented health & safety management systems. In this study, the process of the removal work of the asbestos cement slate was analyzed by IDEF-0 modeling and evaluated by 4M risk assessment method. The results show that removal work of the asbestos cement slate was classified five process and eighteen detail process. The risk of safety side the higher than the risk of health side in 4M risk assessment.

A Study on Water Tree Degradation Using Image Measurement in Underground Power Cables (화상계측에 의한 지중 전력케이블의 수트리 열화에 관한 연구)

  • Kim, Duck-Keun;Lim, Jang-Seub;Lee, Jin
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.12
    • /
    • pp.1063-1068
    • /
    • 2000
  • Water treeing in underground distribution power cable is not easy to observe by nondestructive method and it has very complex patterns. This study describes the principles and practices of a continuous observation of initiation and growth of tree in polymeric insulation material using an image measurement technique. Using this technique we could observe water tree and the growing process of electrical tree due to the water tree and the growing process of electrical tree due to the water tree. All of these growing process is analyzed quantitatively by image measurement program composed of borland c++. We fabricated the thin film type specimen to observe water tree easier and also the needle electrode was prepared by etching method using electrolytes. Initiation and the growth of three was observed somewhat different depending on the applied voltage and the water electrode. AgNO$_3$solution electrode accelerates the initiation and the growth of water tree, compared to those of distilled water electrode. The water and the electrical tree occurred by water tree has discontinuous growth characteristic.

  • PDF

The Design and Experiment of a Planar Patch Sensor for Partial Discharge Diagnostics in 6.6 kV Rotating Machine Stator Windings

  • Yang, Sang-Hyun;Park, Noh-Joon;Park, Dae-Hee;Kim, Hee-Dong;Lim, Kwang-Jin
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.5
    • /
    • pp.173-176
    • /
    • 2009
  • In the stator windings of a 6.6 kV rotating machine, internal discharges, slot discharges, and surface discharges are mainly caused by internal voids and insulation degradation. If a partial discharge(PD) occurs in an inner-part of the stator windings, it will cause electromagnetic pulses with wide frequency ranges. Discharge sparks and electromagnetic pulses generated from a discharge source, can be detected using various RF resonators like an EM sensor. In order to detect these types of electromagnetic sources, a planar patch sensor was designed and fabricated using a CST-MWS simulation, and PD signals from an artificially defected stator winding were also measured by the sensor proposed in this study. Furthermore, an HFCT was used as a reference sensor and compared with the proposed new planar patch sensor. In the results of the experiment, the planar patch sensor showed a similar performance to the HFCT sensor.

Effects of PD-induced Degradation on the accumulation of Space Charges in the Polymer Insulation (고분자 절연 재료에서 부분방전에 의한 열화가 공간전하 축적에 미치는 현상)

  • Shin, Doo-Sung;HwangBo, Seung;Kang, Ji-Hoon;Han, Min-Koo
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1612-1614
    • /
    • 1997
  • 고분자 절연재료의 결함에 의하여 발생하는 부분방전은 고분자 재료의 화학적, 전기적 열화를 가져오며 때로는 전기 트리로 성장하여 재료의 절연파괴에 이르게 하기도 한다. 따라서 부분 방전 현상의 메카니즘 뿐만 아니라 측정법에 대한 많은 연구들이 있었으나 부분방전 열화가 고분자 재료에 미치는 열화과정에 대하여서는 명확한 메카니즘이 보고되지 않았다. 본 논문에서는 부분방전에 의한 고분자 절연재료 내의 공간전하 축적 현상에 대하여 연구하였다. 고분자 재료로는 현재 전력용 케이블에 주로 사용되고 있는 가교 폴리에틸렌(XLPE)를 사용하였으며, 1kHz의 주파수로6kV, 8kV, 10kv 및 11kV로 수시간 부분방전을 발생시킨 후 펄스정전응력법(PEA)으로 공간전하를 측정하였다. 실험결과 부분방전에 의하여 고분자 재료 내에 이종공간전하의 주입이 확인되었으며 따라서 부분방전에 의하여 고분자 재료가 열화되며 이러한 열화에 의한 전자의 방출율의 변화와 같은 고분자 표면의 상태 변화에 의하여 부분방전의 패턴에 지배적인 영향을 미친다. 이러한 공간전하의 축적에 의하여 부분방전 현상에 미치는 영향은 추후 보고할 예정이다.

  • PDF

Characteristics of Critical Current Degradation with Bending Diameter of High Temperature Superconducting Cable (고온 초전도 케이블의 굽힘 직경에 따른 임계전류 저하 특성)

  • Kim Hae Joon;Kim J.H.;Cho J.W.;Sim K.D.;Bae J.H.;Kim H.J.;Seong K.C.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1067-1069
    • /
    • 2004
  • 22.9[kV]/50[MVA]/30[m] HTS transmission power cable has been developed and tested at Korea Electrotechnology Research Institute and LG Cable Company by 21 century center for applied superconductivity technology. It is necessary to measure of critical current degradations, AC loss, insulation test and etc at the HTS cable development. This paper is analyzed characteristics that critical current of HTS cable bending condition according to this paper. We will be able to decide the diameter of drum which HTS cable is wound around and minimum curvature radius of HTS cable from results of this research.

  • PDF

Surface aging and hydrophobicity recovery of silicone rubber by salt fog method (Salt fog 시험법에 의한 실리콘 고무의 표면 열화 및 발수성 회복 특성)

  • 김정호;서광석;문중섭;송우창;이재형;박용관;양계준;유영식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.636-641
    • /
    • 2000
  • The purpose of this study is assessing the characteristics of surface aging and recovery of hydrophobicity for silicone rubber which takes a great interest as outdoor insulation recently subjected to the combined stressed of salt fog and AC power. The methods for assessing are contact angle ATR-FRIR, AFM and XRD. In addition salt fog method is adopted as the artificial contamination experiment and AC power is applied 24 hour on and 24 hour off repeatedly for 5 cycles. The results suggest that degraded surface was more rough than virgin but was restored water repellency through the off cycle. It was due to not only the formation of fractal surface but also maintenance of hydrophobic surface by diffusion of low molecular oil. Although surface recovers initial hydropohbicity there are possibilities of decreasing electrical performance due to irreversable changes such as depolymerization of surface and loss of filler particles. This fact is confirmed by surface conductivity measurement showing that the degradation is significant and the recovery of hydrophobicity is imperfect as the energized cycle increases.

  • PDF