• Title/Summary/Keyword: Insulation characteristics

Search Result 1,269, Processing Time 0.023 seconds

A Study on the step response characteristics in shielded resistor divider for full lightning impulse voltage (전파 뇌충격전압 측정용 쉴드저항분압기의 직각파 특성에 관한 연구)

  • 김익수;이형호;조정수;박정후
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.45 no.2
    • /
    • pp.283-288
    • /
    • 1996
  • This paper presents the development technology of standard shielded resistor divider for full lightning impulse voltage. The ability of large-capacity power apparatus to withstand lighting stroke is usually evaluated by means of full lightning impulse voltage. Lightning impulse voltage test has been essential to evaluate the insulation performance of electrical power apparatus. Recently international standard (IEC 60) on high voltage measurement techniques is being revised and requests a formal traceability of high voltage measurements. Therefore, general interest for this area has grown considerably during last years, and several international intercomparisons have already completed worldwide, i.e. Europe, Japan, America etc., In this viewpoint, we have also investigated the step response of the standard shielded resistor divider, which satisfies the IEC recommendation.

  • PDF

Characteristics of Thin-film Type Pt-RTD's Fabricated on Si Wafers (Si기판상에 제작된 박막형 백금 측온저항체 온도센서의 특성)

  • 홍석우;노상수;정귀상
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.354-357
    • /
    • 1999
  • This paper describes on the electrical and physical charateristics thin-film type Pt-RTD\\`s on Si wafers, in which MgO thin-films were used as medium layer in order to improve adhesion of Pt thin-films to SiO$_2$ layer. The MgO medium layer had the properties of improving Pt adhesion to SiO$_2$ and insulation without chemical reaction to Pt thin-films and the resistivity of Pt thin-films was improved. In the analysis of properties of Pt-RTD, TCR value had 3927 ppm/$^{\circ}C$ and liner in the temperature range of room temperature to 40$0^{\circ}C$

  • PDF

Hydrothermal Reaction Characteristics on the ALC of Pitchstone-Lime System (송지암-석회계 ALC에 대한 수열반응 특성 - 배합비에 따른 영향)

  • 최병현;김순환;안용관;이종민
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.8
    • /
    • pp.660-666
    • /
    • 1992
  • Pitchstone reacted with CaO in hot water(9$0^{\circ}C$) and increased its sedimentary volume by forming Ca(OH)2 and calcium silicate hydrates. ALC was prepared from gel at 9$0^{\circ}C$ and subsequently autoclaved at 18$0^{\circ}C$ by using the property of swelling and the physical properties of ALC was investigated with experimental conditions. When the ratio of pitchstone/CaO was 2 (CaO/SiO2 mol ratio=0.81), bulk density, modulus of rupture and thermal conductivity of the ALC were 0.75g/㎤, 73kg/$\textrm{cm}^2$ 0.150 kcal/m.hr.$^{\circ}C$, respectively. The crystalline phase of it was mainly tobermorite. Therefore ALC was turned out to be much lightweighted and good thermal insulation.

  • PDF

Fault Analysis of IPM type BLDC Motor Using Nonlinear Modeling of Stator Inter Turn Faults (고정자 절연파괴 비선형 모델링을 이용한 매입형 영구자석 전동기의 고장분석)

  • Kim, Kyung-Tae;Hur, Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.531-537
    • /
    • 2011
  • This paper proposes a finite element method (FEM)-based model of an interior permanent magnet (IPM) type BLDC motor having stator inter-turn faults. For more realistic simulation studies, the magnetic non-linearity is also considered in proposed model. And the simulation data are verified through experiment. By integrating the developed model with a current-controlled voltage source inverter (CCVSI) model, the characteristics of an inter-turn fault operated by six-switched inverter are investigated considering the speed control. And the circulating current, which is induced by magnetic linkage flux originated from PM, was analyzed from the view point of distortion of air-gap magnetic flux distribution caused deterioration of their torque.

Characteristics of Ultra High Frequency Partial Discharge Signals of Turn to Turn Defect in Transformer Oil (절연유 내 변압기 Turn간 결함에 의한 부분방전의 극초단파 전자기파 신호 특성)

  • Yoon, Jin-Yul;Ju, Hyung-Jun;Goo, Sun-Geun;Park, Ki-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.10
    • /
    • pp.2000-2004
    • /
    • 2009
  • In general, for the condition monitoring of a power transformer using the UHF PD measuring technique, detection of any partial discharge, identifying the defect in the transformer and locating the insulation defect are necessary. In this paper one of the most frequent detects which can result in turn to turn fault in power transformer was examined for identifying the defect. In order to model the defect, as a discharge source, a partial discharge cell was used for experimental activity. Magnitude of electromagnetic wave signals and corresponding amount of apparent discharge were measured simultaneously against phase of applied voltage to the discharge cell. Frequency range and phase resolved partial discharge signals were measured and analyzed. The results will be contributed to build the defect database of power transformer and to decrease the occurrence of transformer faults.

A Study on the Flame Retardant Effect for Metal Complexes-Cellulose Hybrid Insulator (금속착물-셀룰로오스 복합 단열재의 난연 효과 연구)

  • Kim, Hong;Kang, Young-Goo
    • Journal of the Korean Society of Safety
    • /
    • v.10 no.3
    • /
    • pp.62-67
    • /
    • 1995
  • The combustion characteristics of cellulose Insulation treated with several metal complexes such as Aluminium hydroxide, Cupric sulfate pentahydrate, Magnesium sulfate heptahydrate, Manganese chloride tetrahydrate and Tnisodium phosphate dodecahydrate are studied to evaluate the effectiveness as a potential flame retardant for cellulosic materials. In this study, we found that LOI values of cellulosic materials treated with the metal complexes are generally increased with the increase of their content. At high concentration, CS(24% ) and SP(24% ) show high LOI values, suggesting resistance to flame spread, The materials examined in this study were found to be relatively more resistance to smouldering and flaming combustion in comparision with untreated cellulosic material. The flammability behavior of the materials exhibits combustion process as follows : LOI$\rightarrow$smouldering region$\rightarrow$smouldering-flaming spread region$\rightarrow$flame spread region.

  • PDF

FEM을 이용한 몰드변압기의 예방진단에 관한 연구

  • 청영기;정종욱;최명준;김재철;박일한;곽희로
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 1997.10a
    • /
    • pp.70-73
    • /
    • 1997
  • This paper describes the technique for detecting failure symptom of mold transformer. This study uses the vibration signal analysis method and FEM as the technique. A loading back method is constructed for experiment, accelation sensors are adhered for measurement of vibration signal. Vibration signal measured by this method is analyzed into variation trend of measurement variables by control of control variables. Magnetic field distribution of molded winding is also acquired by FEM considering the design specfication and the characteristics of insulation material, in conclusion, he relation of results between vibration signal and FEM is studied by these methods.

  • PDF

Introduction of the field - test evaluation system in KEPCO (배전 실증시험장 시스템 현황 소개)

  • Kim, Dong-Myung;Choi, Sun-Kyu;Jang, Sang-Ok;Oh, Jae-Hyoung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.05a
    • /
    • pp.81-85
    • /
    • 2004
  • This paper describes the testing facility to demonstrate the performance of the distribution class circuit breakers and switchgears and the testing methods. The field-test evaluation system consists of two parts. One is the distribution system for simulation of the condition on interruption mode of switches which are installed in the system and tested by the AFG(Artificial Fault Generator) and the thunderbolt generator just like in the real field. The other is a laboratory for confirmation or the important characteristics regarding to the insulation, gas, environment durability of equipment. For the fatal failure mode, a FMEA(Failure Modes and Effects Analysis) technique which is a kind of a structural analysis to consider a counter-plan was emploved.

  • PDF

The Characteristics of Artificial Contamination of Distribution Polymer Insulators Used for Outdoor Insulation (옥외에서 사용되는 배전용 폴리머애자의 인공오손 특성)

  • 이병성;한재홍;김찬영;한상옥
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.595-597
    • /
    • 2000
  • Poymeric insulators using in an heavy contamination area are easily attached to contaminants such as salt and by-products of industrial processes. To understand its effect on contaminants adhered to these insulators, we manufactured slurry mixed by some kaolin and salt as artificial contaminated solution. And then put samples in its slurry, for about one minute. And these samples are dried in natural condition for 6 days. We measured the degree of contaminant, AC leakage current for these contaminated samples.

  • PDF

Development Of A Pole On The Distribution Line System (배전용 FRP 전주의 제조 기술 개발)

  • 이웅선;한만준;조한구;박기호;송일근
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.402-404
    • /
    • 2000
  • The FRP pole had great advantages over other material poles. Light weight, easy installing and transporting were good characteristics. The material's superior properties represented the good durability for sea weather and air pollution, good insulation for electric, and changeable colors. In those properties, usages were like a area affected by sea, downtown, the area among the mountains and a special area for the outstanding views. It was studied that pole manufacturing method, structure analysis of pole by FEM in this study. Filament winding method was selected for a new pole manufacturing method. It produced the tapered poles and mechanically strong properties.

  • PDF