• Title/Summary/Keyword: Insulation characteristics

Search Result 1,269, Processing Time 0.029 seconds

The Fractal Estimation and on the Long-Term Reliability in Polymer Insulation (폴리머 애자의 장기 신뢰성과 프랙탈 평가)

  • Lim, Jang-Seob;Kim, Jin-Gook;Lee, Jin;Chung, Seung-Cheon;Lee, Woo-Sun
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.08a
    • /
    • pp.117-120
    • /
    • 2003
  • Fractal mathematics is being highlighted as a research method for classification of image. But the application of Fractal dimension(FD) has been required the complicated calculation method because of its complex repetition progressing. In this paper, it has been developed the new approach method to express the Fractal Dimension(FD) for aging level calculation and estimation system of outside insulator using special image processing algorithm. As a result after FD testing, the recognized aging estimation of FD has a very characteristics compared to the conventional visual inspection.

  • PDF

Preparation and Characteristics of High Voltage Liquid Silicone Rubber by Modified Cross-linking Agent

  • Jung, Se-Young;Kim, Byung-Kyu
    • Transactions on Electrical and Electronic Materials
    • /
    • v.10 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • There is a growing demand for a high voltage silicone rubber composite with high mechanical property and high electrical property. The effect of modified cross-linking agent on the mechanical, electrical properties, and short-circuit test performance of silicone rubber insulators have been investigated. To use base polymer, the various silicone polymers were prepared by the equilibrium polymerization. Aluminum trihydrate surface was treated by vinyl silane. Liquid silicone rubber nanocomposite was prepared from the compounding of VPMPS, HPDMS, catalyst, and alumina trihydrate modified with 1,3,5-trivinyl-l,3,5-trimethylcyclotrisiloxane. The mechanical property and electrical property for insulation materials were measured, indicating the high tensile strength and the good short-circuit property.

Study on Controlling Oil Movement in Electro-wetting Display (Electro-wetting Display의 오일의 움직임 제어 방법에 대한 연구)

  • Kim, Youn-Sik;Kim, Su-Young;Kim, Tae-Hyun;Song, Eun-Gyoung;Sureshkumar, Palanivelu;Lee, Seung-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.2
    • /
    • pp.173-177
    • /
    • 2007
  • Electro-wetting display (EWD) that displays information by controling movement of fluid is one of the strong candidates for electronic paper display (EPD). In EWD cell. the movement of oil which locates between hydrophobic insulation layer and deionized water is rather random, which makes it difficult to realize gray scale, fast response time, and good color characteristics. In this paper, we investigated how to control the oil movement in specific one direction by surface treatment and pattered electrodes. From these experiments, we could control oil movement in a desired direction.

Detemination of Tower Skeleton Diagram for KEPCO 765kV Transmission Lines (765kv 송전용 철탑 Skeleton Diagram 결정)

  • Park, K.H.;Kim, Y.W.;Won, B.J.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07e
    • /
    • pp.1804-1806
    • /
    • 1997
  • Route conditions, applied voltage and the condition of stringing conductors should be considered in determining standard types and skeleton diagrams of towers. In skeleton diagrams the necessary number of insulators and the air clearance have been decided by the results of studies on insulation coordination. Galloping, sleet-jumping, sag characteristics and the possibility of closeness of conductors should be considered according to the condition of stringing conductor and the span. After reviewing those factors, it is necessary to determine the minimum vertical and horizontal distance for the safety of transmission lines under any circumstances. Also it should be economical.

  • PDF

Effects of Dielectric Breakdown in XLPE Insulation Cables by Metal Impurities (XLPE 절연케이블내 금속성 불순물이 절연파괴에 미치는 영향)

  • Lee, Woo-Sun;Choi, Chang-Ju;Chung, Yong-Ho;Kim, Nam-Oh;Kim, Chung-Gu;Kim, Sang-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1196-1198
    • /
    • 1997
  • In this work, simultaneous measurement such as change distribution and electrical conduction of maleic anhydride grafted XLPE was investigated. Heterocharge was found in XLPE and it decreased with increasing MAR graft ratio in XLPE-g-MAH. Conduction currents also decreased with increasing MAR graft ratio. The relationship between the space change behavior and the electrical conduction characteristics in XLPE-g-MAH is discussed.

  • PDF

Properties of PD Pulses accompanying with Electrical Tree in LDPE (LDPE에서 전기트리에 수반된 부분방전 펄스의 특성)

  • Park, Y.G.;Bae, M.H.;Kang, S.H.;Lim, K.J.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1997.07d
    • /
    • pp.1507-1509
    • /
    • 1997
  • Property of insulation of electric machine is severely affected by process of electrical tree growing. Partial discharges(PD) have been used to determine degradation of insulations. In this paper, PD quantities detected and analyzed are PD magnitudes, repetition rates, phase angle distribution of PD pulses, and wavelet transformation. The wavelet transformation is an extended method of fourier transformation. The fourier transformation is a powerful tool for signal analysis, but it can't include informations for time. However the wavelet transformation analysis can include on the informations of time and frequencies at the same time. This paper discusses correlation between process of electrical tree growing and characteristics of PD in LDPE specimens.

  • PDF

Cause Analysis of Cone Roof Tank Collapse during Plant Construction (플랜트 공사 중 발생한 Cone Roof Tank 붕괴 사고 원인 분석)

  • Kim, Seung-Han;Kim, Byung-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.3
    • /
    • pp.71-80
    • /
    • 2016
  • This study is on safety improvement measures through analysis of accident cases during plant storage tank construction. Storage tank is a general term for artificial ground facility constructed to store oil, water, gas, and other chemicals. Some companies have clustered storage tanks (tank farm). The construction methods vary according to the component and types of fluids. Because most of the construction procedures include lifting heavy weight materials using heavy construction equipment and are carried out at high places, storage tank construction contains more risk factors than normal aerial construction. Recently, major accidents such as storage tank collapse have occurred often, and cost many lives due to the characteristics of the structure. In this study we would like to analyze the cause of these accidents and propose measures to improve safety.

Comparison Study of Sound Transmission Loss in High Speed Train

  • Kim, Tae-Min;Kim, Jeung-Tae
    • International Journal of Railway
    • /
    • v.4 no.1
    • /
    • pp.19-27
    • /
    • 2011
  • Many studies for improving the railway vehicle's performance and comfort such as speed, weight and noise are currently in progress. Improving the structural characteristics of the vehicle for greater noise insulation is considered important for reducing disturbance due to noise, but measuring transmission loss entails large costs. This study explores an alternative method for estimating and measuring the railway vehicle's transmission loss that involves on applying the numerical analysis coupled with scaled reverberation chamber measurement. The transmission loss measurement using scaled reverberation chamber was performed after the compensation value was found through 1mm thickness(1t) specimen. For numerical analysis, a commercially available acoustics solver VA ONE was used. The proposed method is found to lead to transmission loss measurement comparable to the measurements based on large-scale reverberation chamber. Thus, it can be argued that a reliable method has been developed for measuring railway vehicle's transmission loss.

Analysis of the lightning characteristics by LPATS Data during 7 year (LPATS에 의한 7년간의 한반도 뇌격특성분석)

  • Woo, J.W.;Shim, E.B.;Kwak, J.S.;Kweon, D.J.;Moon, J.D.;Han, S.O.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.509-511
    • /
    • 2003
  • Because the overhead transmission lines are exposed to the outdoor weather, the faults of the transmission lines are due to natural conditions, and among these faults, the outage rate by lightning is about 50%. The lightning causes the damage of power system equipments, the shut down of electricity and the electro-magnetic interference. Therefore, the pertinent insulation design is important, not only to decrease the damage of the facility itself but also to increase the reliability of electric power system. For these reasons, we have to obtain and accumulate the lightning current parameters for the basic lightning research. This paper describes the statistical distribution of lightning current parameters and the IKL map.

  • PDF

Considerations on the Long-term Reliability of On-line Partial Discharge Ceramic Sensor for Thermal Power Generators and its Demonstration in the Field

  • Sun, Jong-Ho;Youn, Young-Woo;Hwang, Don-Ha;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.1
    • /
    • pp.103-108
    • /
    • 2012
  • The present study describes the considerations on the long-term reliability of the on-line partial discharge (PD) ceramic sensor for thermal power generators. Voltage acceleration aging tests were carried out under continuous and impulsive thermal aging at more than $100^{\circ}C$, considering the practical service environment. Experimental results show that the sensors have a life that could last for more than 100 years, excellent dielectric characteristics, and insulation strength. In addition, the ceramic on-line PD sensors were installed in a thermal power generator in Korea for demonstration. The results of the PD calibration and test voltage application prove that the on-line ceramic sensors have satisfactory performances for on-line PD measurement.