• Title/Summary/Keyword: Insulation characteristics

Search Result 1,267, Processing Time 0.034 seconds

Estimation of Total Dust Concentration Complying with the TLV of Airborne Man-made Mineral Fibers by Regression Analysis (회귀분석에 의한 공기중 인조광물 섬유 허용기준과 부합하는 총분진 농도의 추정)

  • Shin, Yong Chul;Yi, Gwang Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.9 no.2
    • /
    • pp.158-166
    • /
    • 1999
  • The purpose of this study was to investigate the correlation between airborne total dust and man-made mineral fibers (MMMF), and to estimate total dust concentration to maintain below the American Conference of Governmental Industrial Hygienists (ACGIH) Threshold Limit Value (TLV$^{(R)}$) for the MMMF. The regression coefficients between airborne total dust concentrations and fiber concentrations determined in the industries producing glass fibers, rock wool. refractory ceramic and continuous filament glass fibers products were 0.41, 0.42, 0.20 and 0.19, respectively. The size characteristics of fibers as well as the amounts of contaminated non-fibrous dusts could affect the correlation intensities. When total dust and fiber exposure data were compared with the occupational exposure limits, there was a large gap between two evaluation results. The regression coefficient between total dust and fiber data was increased ($r^2=0.88$) in the process of insulation installation generating in the higher levels of glass or rock wool fibers. In this case, an estimated total dust concentration of glass wool or rock wool fibers complying with the ACGIH TLV (1 f/cc) was $1.7mg/m^3$. In conclusion, the total dust and fibers concentrations was highly correlated at the higher exposure levels so that total dust-monitoring data could be used to control simply and economically and to estimate worker's exposure to fibers.

  • PDF

Analysis on the Effect of Filter to Mitigate Transient Overvoltage on the High Voltage Induction Motor Fed by Multi Level Inverter using EMTP (EMTP를 이용한 멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감필터의 효과분석)

  • Kwon, Young-Mok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.10
    • /
    • pp.82-93
    • /
    • 2006
  • In this paper, filters are designed to reduce transients overvoltage in inverter fed high-voltage large-capacity induction motor drive system. Design issues for a LCR filter at the inverter output terminals to reduce the dv/dt of the inverter output pulse and a RC filter at the induction motor input terminals to match the characteristic impedance between cable and induction motor are examined in detail. These filters are modeled to be suitable to high-voltage large-capacity induction motor. The performance of the filter is evaluated through simulation using EMTP(ElectroMagnetic Transients Program). We presented filters that used high voltage large-capacity induction Motor on the basis of this. Effect of the filter is analyzed for variation of the cable length. Characteristics of filters are analyzed to reduce harmonic in voltage waveform of induction motor input terminal. The switching surge voltage became the major cause to occur the insulation failure by serious voltage stress in the stator winding of induction motor. Filter for to mitigate transients overvoltage presents a required component in drive system of high-voltage large-capacity induction motor. Also, proposed filters are proved through simulation using EMTP.

A Study on Methodology for Verifying Energy Saving and Activity in School (학교 건물에서의 에너지절감 성과 활동 검증을 위한 방법론 연구)

  • Lee, Hangju;Kim, Insoo
    • Journal of Energy Engineering
    • /
    • v.29 no.1
    • /
    • pp.25-33
    • /
    • 2020
  • Recently, as the mandatory policy of zero energy building is promoted, policies / systems for transition to Zero Energy School are being promoted, but there is no method to systematically analyze and verify the results of energy saving activities for school buildings. For the study of energy performance verification methodology, the current status of related standards was referred to, and the case study of other methodologies was conducted to examine the tools that can analyze the performance in the field. In addition, this study analyzed the current status and characteristics of energy management through domestic school visits. In this paper, we presented various energy saving projects such as air conditioning and heating facilities, lighting, insulation, change operation behavior, and improve operation methods in new and existing school buildings, and M & V methods for verifying energy savings before and after implementation of energy conservation projects.

The Analysis of the Carbonization Properties between RCD Source Terminals Deteriorated by Tracking (누전차단기 외함 전원측 단자사이의 트래킹에 의한 탄화특성 분석)

  • 최충석;송길목;김동우
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.13-19
    • /
    • 2003
  • In this paper, we studied on the characteristics of RCD(Residual Current Device) case deteriorated by tracking, and compared the tracked samples between in the site of fire($S_1$) and in the reappearance experiment($E_1$). This experiment is applied to IEC Publ. 112 method. Electrical fire by tracking occurred after scintillation and dry-band generated. The insulation resistance between source terminals of RCD case was about 25.7Ω in $E_1$ and the resistance was about 58.6Ω in $S_1$.The exothermic peaks of $E_1$ appeared at $491.0^{\circ}C$ and $603.2^{\circ}C$. The exothermic peak at $603.2^{\circ}C$ was shown by tracking. And the exothermic peak of $S_1$ appeared at $593.1^{\circ}C$. In spectrum of $S_1$ and $E_1$, absorption peak didn't appear at near 1590 cm$^{-1}$ .

Study on the Thermal Protective Performance Measurements of Fire Fighter's Protective Clothing for Low Level Radiant Heat Exposures (저열유속 조건의 복사열 노출에 따른 소방보호복의 열보호성능 측정에 관한 연구)

  • Lee, Jun-Kyoung;Bang, Young-Jun;Bang, Chang-Hoon;Kwon, Jung-Suk
    • Fire Science and Engineering
    • /
    • v.28 no.2
    • /
    • pp.1-8
    • /
    • 2014
  • Despite advancements in the development of synthetic fibers and materials that provide better insulation, fire burn injuries remain a significant issue. To ensure adequate protection, clothing and equipment must be selected on the basis of performance. There are different standards like ISO standards applicable to each of the various types of clothing used by fire fighters. But, in most cases, the tests are performed in the conditions of high heat flux exposure, the clothing material can be destroyed easily. Thus the effective way to investigate the protective performance for the low (radiant) heat flux conditions should be needed. Therefore improved RPP (Radiant Protective Performance) test method based on the onset of pain burn injury was suggested. Experiments were performed to verify the proposed method with current protective clothing for fire fighters and the transient heat transfer characteristics were identified, also. Moreover, several protective performance indices were acquired from experimental results to analyze their relations.

A Study on Electrostatic Electrification Relaxation Properties of Glass Filament for Insulation (절연용 유리장섬유의 정전기 대전완화 특성에 관한 연구)

  • Lee, Sung Ill;Lee, Won Jae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.28 no.12
    • /
    • pp.837-842
    • /
    • 2015
  • In this study, the characteristics of electrostatic attenuation in plain shape glass filament sample (0.29 mm thickness, cross section of $12.25cm^2$, $16cm^2$, $20.25cm^2$) for insulator has been measured at temperature of $5^{\circ}C{\sim}38^{\circ}C$, humidity of 50%~90%. The results of this study are as follows. In case of samples that the cross section is $12.25cm^2$, $16cm^2$, $20.25cm^2$ at humidity of 50%~90%, it found that the electrification voltage of electrostatic increased with increasing temperature, with a return to decrease at $20^{\circ}C$. In case of samples that the cross section is $12.25cm^2$, $16cm^2$, $20.25cm^2$ at temperature of $5^{\circ}C{\sim}38^{\circ}C$, it found that the electrification voltage of electrostatic decreased with increasing humidity. In case of the sample at temperature of $20^{\circ}C$ and humidity of 65%, 75%, it found that the electrification voltage of electrostatic increased with increasing cross section. In case of the sample at humidity of 65% and cross section of $12.25cm^2$, the time that it takes to reduce electrification voltage of electrostatic in half decreased to 0.912s, 0.736s, 0.673s with increasing temperature to $10^{\circ}C$ $20^{\circ}C$, $30^{\circ}C$.

An Experimental Study on the Performance of a Simultaneous Heating and Cooling Heat Pump in the Cooling-only and Cooling-main Operation Mode with the Variation of the Indoor Air Temperature (동시냉난방 열펌프 시스템의 냉방전용 및 냉방주체 운전모드에서의 실내기온 변화에 따른 성능특성에 관한 실험적 연구)

  • Ahn, Jae-Hwan;Joo, Young-Ju;Kang, Hoon;Chung, Hyun-Joon;Kim, Yong-Chan;Choi, Jong-Min
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2165-2170
    • /
    • 2008
  • The cooling load in winter season is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. Therefore, the development of a multi-heat pump which can cover heating and cooling simultaneously for each indoor unit is required. In this study, the characteristics and performance of a simultaneous heating and cooling heat pump in the cooling-only and cooling-main operating mode was investigated experimentally with a variation of indoor air dry bulb temperature which is from $21^{\circ}C$ to $35^{\circ}C$. EEV opening was adjusted from 20% to 24% during the tests. When the indoor air temperature varied, the performance in the cooling-only mode was more sensitive to the temperature than in the cooling-main mode. The total capacity and COP were increased by 53.8% and 48.1%, respectively, in the cooling-main, while those were increased by 19.6% and 19.3% in the cooling-only mode. The performance differences between the two operating modes became larger at lower temperatures, especially for the COP.

  • PDF

Post-purchase Evaluation on the Maternity Wear on the Current Korean Market by Survey and Wear test

  • Park, Soon-Jee;Lee, Hee-Jung;Suh, Chu-Yeon
    • Journal of Fashion Business
    • /
    • v.11 no.3
    • /
    • pp.15-34
    • /
    • 2007
  • This study was designed to collect a precise information concerning to the preference and evaluations after usage of pregnant Korean woman for the maternity wear bysurvey and wear tests. Through the survey, 212 respondents were asked to answer what type of maternity wear they prefer and what requirements for maternity wear design are important. According to the results of survey, the mostly preferred maternity wear items were pants and one-piece dress. Korean customers for maternity wear usually pay more for the one-piece dress than other items and they also usually put on medium price pants and low-price blouse. Concerning to the purchase criteria, it may be said that design and movability, fit factors are the buying decision criteria of great weight for Korean pregnant women. Special function most desired was thermal insulation, followed by buffer action, electromagnetic shield and quickly water-absorbent and dry property. Preferred maternity wear design details were flat collar, slightly fitted waist and empire style, gather skirt, rubber band waist. Wear test was performed for two kinds of blouse (BL) and one-piece dress (OP), and threekinds of pants (PT), which have different design details respectively. According to the wear test for ready-to-wear maternity garments, the garment which considers well the characteristics of Korean pregnant women body shape earned much higher score no matter of brands or prices. Generally, high-priced national brands received an excellent evaluation in design aspect, but not satisfied with comfort to move.

Fabrication and Characteristics of HTS Field Winding of a 100 hp Synchronous Motor (100마력 동기전동기용 고온초전도 계자권선 제작과 특성)

  • Sohn Myung-Hwan;Baik Seung-Kyu;Lee Eon-Young;Kwon Young-Kil;Jo Young-Sik;Moon Tae-Sun;Kim Yeong-Chun;Kwon Woon-Sik
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.2
    • /
    • pp.88-93
    • /
    • 2005
  • To develop a 100 hp high temperature superconducting(HTS) motor with high efficiency first in Korea, we fabricated a HTS field winding and test. HTS field winding is composed of sixteen HTS race track shaped coils wound with stainless steel-reinforced Bi-2223 tape conductor by react and wind fabrication method. Nomex paper was used for electrical insulation. Each of four magnet pole assemblies was constructed with four double pancake sub-coils, mechanically stacked and electrically in series. Four magnet assemblies were fixed on an aluminum support structure to make effective heat transfer. The Critical current (Ic) was 41.5A at 77K and self field. However the lowest Ic value of sub-coils was 35A. Joule heat generated by each joints between sub-coils was lower than 1mW at 77K and 34A. And Joule heat generated by the joints between field coils was lower than 10mW at 77K and 34A. Joule heat of the whole field winding was 1W at 77K and 32A. And so, the lowest Ic value of sub-coils was more important than Joule heats generated by all joints. The operating current must be lower than the lowest Ic of all the sub-coils. In this paper, design, construction and testing of HTS field winding, Joule heat generated by the joints, and operating current were discussed.

Wet Foam Stability from Colloidal Suspension to Porous Ceramics: A Review

  • Kim, Ik Jin;Park, Jung Gyu;Han, Young Han;Kim, Suk Young;Shackelford, James F.
    • Journal of the Korean Ceramic Society
    • /
    • v.56 no.3
    • /
    • pp.211-232
    • /
    • 2019
  • Porous ceramics are promising materials for a number of functional and structural applications that include thermal insulation, filters, bio-scaffolds for tissue engineering, and preforms for composite fabrication. These applications take advantage of the special characteristics of porous ceramics, such as low thermal mass, low thermal conductivity, high surface area, controlled permeability, and low density. In this review, we emphasize the direct foaming method, a simple and versatile approach that allows the fabrication of porous ceramics with tailored microstructure, along with distinctive properties. The wet foam stability is achieved under the controlled addition of amphiphiles to the colloidal suspension, which induce in situ hydrophobization, allowing the wet foam to resist coarsening and Ostwald ripening upon drying and sintering. Different components, like contact angle, adsorption free energy, air content, bubble size, and Laplace pressure, play vital roles in the stabilization of the particle stabilized wet foam to the porous ceramics. The mechanical behavior of the load-displacements curves of sintered samples was investigated using Herzian indentations testes. From the collected results, we found that microporous structures with pore sizes from 30 ㎛ to 570 ㎛ and the porosity within the range from 70% to 85%.