• 제목/요약/키워드: Insulation characteristics

검색결과 1,267건 처리시간 0.023초

FEM을 이용한 음향신호의 전달특성에 관한 연구 (Investigation on propagation characteristics of AE signal with FEM)

  • 서판석;구경완;김종석;한상옥
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.274-277
    • /
    • 2001
  • This paper describes the simulation study, conducted on the propagation characteristics of AE signal. In the case of gas insulation, such as SF6, the equipment is less affected by the environment condition than air insulation, because the component parts of equipment were placed in the enclosure, which is filled with compressed gas. But, when the breakdown in the electric insulation occurs, it takes much time and economical efforts to repair. Therefore it is very important to diagnose the equipment before the accident. And, in general, UHF and AE signal is the most common transducer to diagnose the state of the power equipment, so, in this investigation, we make a experimental apparatus with aluminum plate and transient analysis with ANSYS to observe the propagation characteristics of AE signal. Through the result of the analysis, we can make a further understanding on the propagation characteristics of AE signal, and get the fundamental skills for the GIS diagnosis.

  • PDF

광섬유 센서로 측정한 절연유에 따른 방전신호 특성 (The Characteristics of Discharging signal in various kinds of insulation oil using Optical Fiber Sensor)

  • 김태영;남진호;서광석;김상준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1599-1601
    • /
    • 1999
  • The characteristics of ultrasonic signal in insulation oil were investigated by optical fiber sensor(OFS) utilizing Mach-Zehnder interferometer. For checking the response properties of OFS ultrasonic signal was generated by function generator in various kinds of insulation oil. The attenuation of ultrasonic signal linearly increased with the increase of viscosity of insulation oil in log scale. Discharging signal was produced by neele-sphere electrode system. Intensity of discharging signal was plotted in terms of cumulative $y^2$ and the intensity of discharging signal in new oil was little bigger than that in serviced one.

  • PDF

Generalized Stability Criterion for Multi-module Distributed DC System

  • Liu, Fangcheng;Liu, Jinjun;Zhang, Haodong;Xue, Danhong
    • Journal of Power Electronics
    • /
    • 제14권1호
    • /
    • pp.143-155
    • /
    • 2014
  • The stability issues of a multi-module distributed DC power system without current-sharing loop are analyzed in this study. The physical understanding of the terminal characteristics of each sub-module is focused on. All the modules are divided into two groups based on the different terminal property types, namely, impedance (Z) and admittance (Y) types. The equivalent circuits of each group are established to analyze the stability issues, and the mathematical equations of the equivalent circuits are derived. A generalized criterion for multi-module distributed systems is proposed based on the stability criterion in a cascade system. The proposed criterion is independent of the power flow direction.

중량벽체의 차음특성에 관한 실험적 연구 (An Experimental Study on the Sound Insulation Characteristics of Heavyweight Walls)

  • 김선우;이태강;송민정
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1078-1085
    • /
    • 1998
  • This study is carried out to investigate the characteristics of sound insulation performances for masonry walls. PC walls and ALC walls. For these purposes. 17 types of masonry walls were selected and tested in accordance with KS F 2808 at reverberation room The sound insulation performance of 8" cement block walls are graded with D-45 ∼ D-55 which are to be evaluated very favorable grade. 4" cement block walls are D-30 ∼ D-40. 1 B cement brick walls are D-40∼D-50 favorable grade. 0.5 B brick walls are D-30∼D-45. 150 mm PC wall is D-50. and ALC walls(150 mm, 200 mm) are D-30∼D-45.

  • PDF

$SF_6$ 가스의 온도변화에 따른 절연특성 (The Characteriztics of Insulation and Discharge with a Variation of Temperature in $SF_6$)

  • 박경태;윤대희;박광서;김이국;박원주;이광식;이동인
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2002년도 학술대회논문집
    • /
    • pp.335-338
    • /
    • 2002
  • In this paper the experiments of insulation characteristics by temperature change of SF6 gas and insulation characteristics about liquid SF6 in GIS(Gas Insulated Switchgear) were described. From this result, at low temperature, the breakdown voltage was increased with a drop of temperature and an increase of the inner pressure in GIS. The ability of insulation in liquid SF6 was higher than that of the highly pressurized SF6 gas.

  • PDF

바닥마감재에 의한 바닥충격음 차음특성 연구 (A Study on the Floor Impact Sound Insulation Characteristics of Floor Coverings)

  • 기노갑;권현종;송민정;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문집
    • /
    • pp.682-686
    • /
    • 2002
  • It is increasing the interest on the comfortable dwelling environment, while sound Insulation performance of materials and elements used in building is falling down as they become thicker and lighter. Therefore, sound insulation performance in building has become the most important factor determining the level of housing, especially for apartment that has common wall and floor with next neighbors. This paper aims to experiment the sound insulation characteristics of floor coverings as their types and to analyse their noise reduction effect.

  • PDF

전력 케이블 절연재에 대한 DC절연파괴강도특성 고찰 (Investigation on DC Breakdown Strength Characteristics of Power Cable Insulation)

  • 이한주;정의환;조성훈;윤재훈;임기조
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2010년도 하계학술대회 논문집
    • /
    • pp.86-86
    • /
    • 2010
  • Recently, CV, CNCV, CNCV-W cable are used to transmit and distribute electric power. And a lot of researchers put more effort to realize high performance. The dielectric breakdown strength characteristic is a standard to design insulators. Examination of that is a main factor to determine long term insulation performance, which is used to diagnose Insulation deterioration. In this paper, we prepared XLPE, XLPE/nano-filler, LDPE/nano-filler for comparing each of the dielectric breakdown strength characteristics.

  • PDF

$SF_{6}$ 가스의 온도변화에 따른 절연특성 (The Characteristics of Insulation with Temperature Variations of $SF_{6}$)

  • 이광식;박광서;박경태;김이국;박창기
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권8호
    • /
    • pp.354-358
    • /
    • 2003
  • In this paper, insulations characteristics by temperature changes(+50~-50[$^{\circ}C$]) of $SF_{6}$ gas in the experimental chamber were studied. From this result, at the low temperature, the breakdown voltage was increased with a drop of temperature and an increase of inner pressure in GIS. In addition the ability of insulation of liquid $SF_{6}$ was higher than that of the highly pressurized $SF_{6}$ gas. That is, with progress of low temperature, the main reason of breakdown was not liquefaction of $SF_{6}$ but rapid decrease of inner pressure. This study will come in greatly handy for the insulation design of GIS in a hard cold region

가열조건이 폴리아미드지의 절연특성에 미치는 영향 (A Study on the heating conditions affect on the insulation characteristics of polyamid papers)

  • 선종호;김우성;김광화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 C
    • /
    • pp.2047-2049
    • /
    • 2000
  • In this study, we describe comparison of insulation characteristics of polyamid papers with heating conditions. The partial discharge behavior until breakdown and breakdown strength for thermal degradation films are observed in $SF_6$ gas chamber. The four layered NOMEX films of thickness of 50${\mu}m$ were used as solid insulation films and the sphere of which diameter is 40mm to sphere electrode system was used and each insulation films were inserted between sphere electrodes. The used gas pressure was 1.0bar and used temperature was each of 250$^{\circ}C$, 270$^{\circ}C$, 300$^{\circ}C$, 320$^{\circ}C$, 350$^{\circ}C$ and the voltage were applied until breakdown films.

  • PDF

통계처리와 패턴 인식 기법에 의한 부분방전 해석 (Analysis of Partial Discharge Signals Using Statistical and Pattern Recognition Technique)

  • 변두균;홍진웅
    • 제어로봇시스템학회논문지
    • /
    • 제12권12호
    • /
    • pp.1231-1234
    • /
    • 2006
  • In this study, we detected electromagnetic waves generated in an enclosed switchgear and applied various statistical methods for detecting signals. We calculated the various statistical factors via the appropriate statistical methods. Further, we used these statistics to recognize the characteristics for each pattern by identifying the partial discharge in each case for normal, proceeding and abnormal states. The characteristics of electromagnetic wave patterns occurred in various states at electric power facilities and were used as an output variable for more efficient diagnosis. In this paper, we confirmed that the pattern of partial discharge signal can be used as one of the factors used to analyze the insulation state and to consider while estimating diagnosis of insulation states by recognizing the signal pattern to intelligence. We will utilize the proposed diagnosis method to determine insulation degradation states.