• 제목/요약/키워드: Insulation Design

검색결과 894건 처리시간 0.031초

항공기소음에 노출된 학교 교실 창호 설계에 관한 연구 (A Study on the Window Design of Classroom Exposed to the Aircraft Noise)

  • 송혁;송민정;박현구;김선우
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.214-223
    • /
    • 2004
  • This study aim to find an appropriate window for classrooms to provide proper sound insulation against aircraft noise and to achieve this goal, measurements were taken of the sound insulation performance of windows with various thicknesses of inner air space and sound absorption materials in the inner air spaces. As a result of this study the improvement of the sound insulation performance of windows(single, double and triple window) was shown through the analysis and the measuring of windows with these characteristics. These results may be applied to the manufacture of window frames and provide basic data for the improvement of the sound insulation performance of windows.

공동주택 발코니 창호의 차음성능 평가에 관한 실험적 연구 (An Experimental Study on Evaluation of the Sound Insulation for Balcony Window in Apartment Houses)

  • 김하근
    • 한국소음진동공학회논문집
    • /
    • 제14권11호
    • /
    • pp.1137-1146
    • /
    • 2004
  • In an apartment house In Korea, the balcony is one of the important spaces as a buffer zone for controlling the outdoor environments such as noise, heating & cooling load, humidity etc. Because most areas of building facade in apartment building occupy the area of balcony window the sound Insulation design of It Is very Important to provide the quiet indoor environment. The aim of this research is to evaluate the sound insulation of balcony windows in apartment building by new and revised Korean Industrial Standards. We measured and studied the sound insulations of 18 balcony windows by the type of measuring methods, noise sources, correction of reverberation time in balcony and so on. The results show that the single-number quantities for sound insulation of windows are ranged from 24 dB to 30 dB.

항공기소음에 노출된 학교 교실 창호 설계에 관한 연구 (A Study on the Window Design of School Class Room Exposed to The Aircraft Noise)

  • 송혁;송민정;박현구;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.710-717
    • /
    • 2003
  • This study aim to find an appropriate window for class rooms to provide proper sound insulation against aircraft noise and to achieve this, measurements were taken of the sound insulation performance of windows with varying thicknesses of inner air space and sound absorption materials in the inner air spaces. As a result of (his study the improvement of the sound insulation performance of windows(single , double and triple window) has been shown through the analysis and the measuring of windows with these characteristics. These results may be applied to the manufacture of window frames and provide data lot the improvement of the sound insulation performance of windows.

  • PDF

공항 인근 건물(호텔)에서의 벽체구조의 차음성능에 관한 연구 (An experimental study on sound insulation of building elements of the hotel near airport)

  • 이성호;정갑철;양관섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.579-585
    • /
    • 2002
  • This study has measured and evaluated the sound insulation of building elements of the hotel near airport. That measurement was made in both the actual site and laboratory. The differences of sound insulation performance in between granite and double glass were measured. Moreover, the difference of sound insulation was analyzed. For the measurement, this study has tried several methodologies, and analyzed the differences respectively. The results from this analysis were applied to produce a design guides for sound insulation to prevent external noise and to make more silent indoor space which satisfied the standard rate of noise.

  • PDF

절연물의 연면섬락 전압에 미치는 금속 격벽의 영향 (The Effect of Metallic Barrier on the Surface creeping Flash-over Voltage along the Insulation Materials)

  • 정성계
    • 전기의세계
    • /
    • 제14권2호
    • /
    • pp.8-13
    • /
    • 1965
  • It is expected that the impurities contained in a solid state insulation material will affect a considerable influence on its break-down voltage, dielectric loss, and insulation resistance. In this thesis, as a preliminary experimental research for the investigation described above, the effect of metalic barrier between the electrodes on the creepin flash over discharge voltage along the surface of a solid insulation material has been investigated, and got some interesting results. It was found that generaly the flash over voltage rises when a metalic barrier is located between the electrodes. The results of this investigation will be taken into account as an important components on the insulation design to prevent the creeping flash over discharge in insulators, bushings, and so on.

  • PDF

인버터구동 고압전동기 열화특성 분석 및 필터 설계기법 확립 (Insulation System and Filter Design for Inverter-Fed Motor)

  • 최영찬;이상동;김익모;정명길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 B
    • /
    • pp.711-713
    • /
    • 2000
  • Recently, the insulation breakdown accident happened at 6.6kV inverter driving motor brings out the reliability decrease to the motor driving system. We need to find the solution with system engineering level. The objectives of this study are developing the appropriate filter for the drive to protect the motor and the insulation system of motor which is driven by inverter. The circuit parameters of cable are calculated by EMTP(Electromagnetic Transient Program) to simulate the system. And we use MATLAB to find the appropriate filter parameter. The simulation and the test results are compared to verify the suitability of the filter parameter. We clarify the cause of the deterioration of the inverter driving motor through the analysis of insulation breakdown accidents. The endurance test scheme and the configuration method of insulation system are established.

  • PDF

고온초전도 케이블의 유전 특성 (Dielectric Characteristics of HTS Cable)

  • 곽동순;김해종;조전욱;성기철;김상현
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 제4회 영호남학술대회 논문집
    • /
    • pp.64-68
    • /
    • 2002
  • According to the increasing power demand for the future construction of many underground cables will be required. However, construction of new ducts for power cables will be more difficult. Therefore, research work for realizing the high temperature superconducting(HTS) cable has advanced, where the development of electrical insulating system at cryogenic temperature is one of the major researches. For an electrical insulation design of HTS cable, it is important to understand not only breakdown but also partial discharge and dielectric loss($tan{\delta}$) in liquid nitrogen/paper composite insulation system. In this paper, we investigated breakdown characteristics in liquid nitrogen/paper composite insulation system for the application to HTS cable. And, we studied the breakdown characteristics of the multi-layer and butt gap of the insulation papers in liquid nitrogen. Also, we measured dielectric loss($tan{\delta}$) of the mini-model Cable made of TERLAM IPP.

  • PDF

Insulation Saving Effect for Korean Apartment House Using Cross-Laminated Timber (CLT)

  • Pang, Sung-Jun;Lee, Bumjin;Jeong, Gi Young
    • Journal of the Korean Wood Science and Technology
    • /
    • 제45권6호
    • /
    • pp.846-856
    • /
    • 2017
  • The aim of this study was to develop the details of cross-laminated timber (CLT) envelops for satisfying the design standard for energy saving (DSEA) and passive standard in South Korea. When the same thickness of 180 mm concrete or CLT was used and the same materials for other layers were used for the roof, wall, and interlayer floor, the required insulation thickness for the different building envelopes in central, southern, and Jeju island was evaluated. As a result, compared to the concrete envelop, about 43 mm of insulation thickness was reduced for wall and roof with the CLT envelope. When the CLT envelopes were modified to protect the CLT from moisture based on FPInnovations (2011), the insulation thickness was further reduced by 12 mm. When the modified CLT building envelops satisfied with a passive standard are used for 10-story building, the required insulation was decreased by $40.89m^3$ for a floor ($105.27m^2{\times}2.3m$ in height) compared to concrete building. As the number of floors increases, about 3.58 m3 of insulation per floor was additionally saved.

Efficiency of insulation layers in fire protection of FRP-confined RC columns-numerical study

  • El-Mahdya, Osama O.;Hamdy, Gehan A.;Hisham, Mohammed
    • Structural Engineering and Mechanics
    • /
    • 제77권5호
    • /
    • pp.673-689
    • /
    • 2021
  • This paper addresses the efficiency of thermal insulation layers applied to protect structural elements strengthened by fiber-reinforced polymers (FRP) in the case of fire event. The paper presents numerical modeling and nonlinear analysis of reinforced concrete (RC) columns externally strengthened by FRP and protected by thermal insulation layers when subjected to elevated temperature specified by standard fire tests, in order to predict their residual capacity and fire endurance. The adopted numerical approach uses commercial software includes heat transfer, variation of thermal and mechanical properties of concrete, steel reinforcement, FRP and insulation material with elevated temperature. The numerical results show good agreement with published results of full-scale fire tests. A parametric study was conducted to investigate the influence of several variables on the structural response and residual capacity of insulated FRP-confined columns loaded by service loads when exposed to fire. The residual capacity of FRP-confined RC column was affected by concrete grade and insulation material and was shown to improve substantially by increasing the concrete cover and insulation layer thickness. By increasing the VG insulation layer thickness 15, 32, 44, 57 mm, the loss in column capacity after 5 hours of fire was 30%, 13%, 7% and 5%, respectively. The obtained results demonstrate the validity of the presented approach for estimation of fire endurance and residual strength, as an alternative for fire testing, and for design of fire protection layers for FRP-confined RC columns.

노출콘크리트 중단열 벽체의 단열성능 분석 (Insulation Performance Analysis of Exposed Concrete Sandwich Wall)

  • 여창재;유정호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.105-106
    • /
    • 2016
  • The study of the sandwich wall with the increasing interest in building energy consumption have been actively conducted. This study designed exposed sandwich wall in the light of energy saving design standard and thermal bridge of share connection. The heat insulating performance was analyzed U-fator using calculation program provided in passive houses association and KS F 2277 (method of measuring thermal insulation of construction component materials).

  • PDF