• 제목/요약/키워드: Insulating varnish

Search Result 12, Processing Time 0.022 seconds

Physical and Electrical Characteristics of Varnish and Varnish Treated Insulating Paper for Pole Transformers

  • Jung, Jong-Wook;Song, Il-Keun;Koo, Kyo-Sun;Song, Hyun-Seok;Kwak, Hee-Ro;Han, Yong-Huei
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.2C no.6
    • /
    • pp.321-326
    • /
    • 2002
  • This paper describes the mechanical and electrical characteristics of insulating paper impregnated with diluted varnish(W-128), according to Korean Standards. The varnish was diluted with a solvent of 6 different wt%. Kraft paper and Nomex paper were impregnated with the diluted varnish in a vacuum condition, and then completely dried. As the mechanical characteristics, the thickness of the completely dried varnish, the drying time and the tensile strength of the specimens were measured, and as the electrical characteristics, the permittivity, the tan $\delta$ and the specific resistance were evaluated as well.

Effect of Electrical Properties in the insulating Varnish due to Internal Voids (내부 보이드가 절연 바니시의 전기적 특성에 미치는 영향)

  • Park, Hyoung-Jun;Heo, Youn;Kim, Weon-Jong;Yoon, Hun-Ju;Shin, Jong-Yeal;Hong, Jin-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.472-475
    • /
    • 2003
  • In this paper, insulating varnish has been used for field magnet and armature impregnated insulating material of electric locomotive and traction motor. When it was duplicated coating, it could be accuse internal void, and which could change electrical characteristics. We used to boundary elemental method of simulation tool, and improved optimal insulating design of insulating varnish according to measuring electric distribution in void of specimen.

  • PDF

Electrical Properties of Insulating Varnish (절연 바니시의 전기적특성)

  • 김정훈;신종열;변두균;이종필;조경순;김왕곤;홍진웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.07a
    • /
    • pp.299-302
    • /
    • 2001
  • In this study, we are studied the electrical conduction and dielectric breakdown properties of insulating varnish. In order to analyze the molecular structure and physical properties of insulating varnishs, FT-lR was used. As the result, it can be confirmed that the peak of alcoholic group appeared in wavenumbers 3452[cm$\^$-1], the peak of =CH appeared in 3080[cm$\^$-1] and the peak of -CH appeared in 2919[cm$\^$-1] respectively. The following results were obtained from electrical properties of insulating varnish. The amplitude of current density was decreased by thickness increasing and the current density was effected by the thermal energy from external due to temperature increasing. In study temperature dependence of dielectric strength, the specimen of 10[$\mu\textrm{m}$] thickness was measurement from room temperature to 180[$^{\circ}C$]. It is confirmed that the temperature regions below 60[$^{\circ}C$] is due to electron avalanche breakdown and the temperature regions over 60[$^{\circ}C$] is due to free volume breakdown which makes electron movements easy.

  • PDF

Electric Characteristics on the Insulating Paper with Varnish-Impregnant (바니쉬 함침이 절연지에 미치는 영향)

  • Kim, Pil-Hwan;Kim, Ju-Han;Lee, Won-Yeong;Han, Sang-Ok
    • Proceedings of the KIEE Conference
    • /
    • 2004.05b
    • /
    • pp.180-182
    • /
    • 2004
  • We have investigated characteristics of varnish and oil impregnant. When transformers are manufactured with some moisture and varnish impregnant not entirely dried, those should be caused by factors that deteriorate the electrical or mechanical property after installation. Therefore, in this study we experienced moisture content of the new insulating paper and the varnish impregnant paper in the ratio of time for confirming factors that deteriorate the paper characteristics. Besides, we investigated a property study that was experienced the value of dielectric strength and tensile strength as no serviced insulating samples of transformer.

  • PDF

Study of Thermally Accelerating Aged Varnish Treated Insulating Paper (바니쉬 함침에 따른 절연지의 가속 열 열화특성에 관한 연구)

  • Kim, Ju-Han;Han, Sang-Ok;Lee, Sei-Hyun;Lee, Byung-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2005.07c
    • /
    • pp.1983-1985
    • /
    • 2005
  • This paper describes moisture content, dielectric strength and dielectric properties of thermally accelerating aged insulating paper as varnish treatment. Kraft, nomex paper were impregnated with diluted varnish, varnish and solvent were diluted in the ratio of 40wt%, in vacuum condition, and then completely dried. To analysis of papers were influenced by varnish treatment, we applied thermal stress, and then measured moisture content, dielectric strength and relative permittivity, $tan{\delta}$ as varnish impregnated papers.

  • PDF

Design technology by structure of transformer (변압기의 형태에 따른 설계기술)

  • Lee O.K.;Song H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.313-316
    • /
    • 2003
  • Investigated about topology of each component of transformer and material choice method and property in this paper. Component of transformer is bobin, winding, insulating paper, Varnish etc. And, experiment and investigated special quality by primary winding of transformer and composition of secondary winding. Investigated loss of transformer and EMI decrease method. Investigated method to select winding size that consider frequency.

  • PDF

Special quality analysis by component type choice of transformer (변압기의 구성요소 선정에 따른 특성고찰)

  • Lee, O.K.;Kim, S.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07c
    • /
    • pp.1601-1603
    • /
    • 2003
  • Investigated about topology of each component of transformer and material choice method and property in this paper. Component of transformer is bobin winding, insulating paper, Varnish etc. And experiment and investigated special quality by primary winding of transformer and composition of secondary winding. Investigated loss of transformer and EMI decrease method. Investigated method to select winding size that consider frequency.

  • PDF

Enhancement of Dielectric Properties of Polyamide Enamel Insulation in High Voltage Apparatuses Used in Medical Electronics by Adding Nano Composites of SiO2 and Al2O3 Fillers

  • Biju, A.C.;Victoire, T. Aruldoss Albert;Selvaraj, D. Edison
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.4
    • /
    • pp.1712-1719
    • /
    • 2015
  • In recent days, there was a significant development on the electrical, thermal, mechanical, physical, chemical, magnetic and optical properties of the polyamide enamel, varnish and other insulating materials by the addition of nano fillers to it. Enamel was used in High Voltage Apparatuses used in Medical Electronics as insulation. Insulating materials determine the life time of the electrical apparatuses. The life time of the insulating materials was improved by the addition of nano fillers to it. Hence the life time of the electrical apparatuses was improved by the mixing of nano fillers to the enamel. In this research, the basic dielectric properties of the enamel and enamel mixed with nano composites of silica and alumina were analyzed and compared with each other. The addition of nano fillers has improved the quality factor and capacitance of the enamel. It was also observed that the addition of nano fillers has reduced the dissipation factor and dielectric losses of the enamel. Heat produced by the dielectric losses was also reduced by adding nano fillers to it.

Estimation of Insulation Life of PAI/Nano Silica Hybrid Coil by Accelerated Thermal Stress (가속된 열적 스트레스에 의한 PAI / Nano Silica 하이브리드 코일의 절연수명 추정)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.68 no.1
    • /
    • pp.52-60
    • /
    • 2019
  • In this paper, four types of insulation coils were fabricated by adding various kinds of glycols to improve the flexibility and adhesion of insulating coils in varnish dispersed with PAI / Nano Silica_15wt%. The applied voltage and frequency were 1.5 kV / 20 kHz for accelerated life evaluation. Through the 6th temperature stress level, the cause of the insulation breakdown of the coil was ignored and only the breakdown time was measured. The Arrhenius model was chosen based on the theoretical relationship between chemical reaction rate and temperature for estimating the insulation life of the coil due to accelerated thermal stress. Three types of distributions (Weibull, Lognormal, Exponential) were selected as the relationship between thermal stress model and distribution. The average insulation lifetime was estimated under the temperature stress of four types of insulation coils through the relationship between one kind of model and three kinds of distributions.

Development of Time Domain Reflectometry Probe for Evaluation of Copper Concentration in Saline Environment (염수환경에서의 구리 농도 평가를 위한 Time Domain Reflectometry 프로브 개발)

  • Lee, Dongsoo;Lee, Jong-Sub;Hong, Won-Taek;Yu, Jung-Doung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.3
    • /
    • pp.15-24
    • /
    • 2018
  • As electromagnetic waves are affected by electrical conductivity or permittivity, they are widely used to evaluate geotechnical characteristics. In this study, a probe for measuring electromagnetic waves using a time domain reflectometry is manufactured to evaluate heavy metal concentration in saline water. In the experiments, a copper is used as a heavy metal, and a probe is demonstrated with the concentration of copper. Solutions were set for 8 different copper concentration (0, 0.01, 0.05, 0.1, 0.5, 1, 5, 10 mg/L) in saline water with 3% salinity. The probe is coated by electrical insulating materials such as epoxy, top-coat, varnish, acrylic paint, heat-shrinkage tube to measure electromagnetic waves in saline water. The measured signals are compared according to coating material. As results, for probes coated with acrylic paint and heat-shrinkage tube, signal variation is not detected. For epoxy, top-coat, and varnish coated probes, the voltage decreases with an increase of copper concentration. Probes coated by epoxy at once and top coat can estimate under 5 mg/L of copper concentration and the probe coated by epoxy twice can estimate over 5 mg/L of copper concentration. This study shows that the probe using the time domain reflectometry can be used to evaluate the concentration of heavy metal in saline water by coating the probe with insulating material.