• 제목/요약/키워드: Insulating

검색결과 1,647건 처리시간 0.026초

평등전계중의 절연유에 미치는 첨가물의 영향 (A study on the effect of additives in insulating oil under uniform electric field)

  • 국상훈
    • 전기의세계
    • /
    • 제30권6호
    • /
    • pp.357-365
    • /
    • 1981
  • When electronegative gas SF$_{6}$ is dissolved and charged with insulating oil, the effect caused in the process by electronegative characteristic is studied and also the pressure effect caused by electronegative SF$_{6}$ acting on the liquid-level is examined respectively. When inert gas Ar is used to find a pressure effect acting on the liquid-level, its effect on dielectric strength is considered in the experiment. With three kinds of impulse voltage different in the duration of wave front and wave tail, a brief experiment if carried out ot see the effects on the dielectric breakdown characteristic as the wave is changing; either if I$_{2}$ and SF$_{6}$ are added to the insulating oil, or if the oil pressure is increased by Ar the dielectric strength becomes great and the longer the duration of wave front is, the greater the increase of the breakdown voltage, because I$_{2}$ added by a small quantity brings about some hirderance in the formation of gas phase. Likewise, the greater the changed pressure is, the greater the incerase of the breakdown voltage. When SF$_{6}$ is charged, the electronegative characteristic is prevailing at the time of low balanced pressure, and the pressure effect at the time of high balanced pressure.ressure.

  • PDF

A Study on the Electrical Strength of Insulating Materials for High-Tc Superconducting Devices

  • Bae, Duck Kweon;Kim, Chung-Hyeok;Pak, Min-Sun;Oh, Yong-Cheul;Kim, Jin-Sa;Shin, Cheol-Gee;Lee, Joon-Ung;Song, Min-Jong;Choi, Woon-Shik
    • Transactions on Electrical and Electronic Materials
    • /
    • 제6권6호
    • /
    • pp.294-300
    • /
    • 2005
  • According to the trend for electric power equipment of high capacity and reduction of its size, the needs for the new high performance electric equipments become more and more important. On of the possible solution is high temperature superconducting (HTS) power application. Following the successful development of practical HTS wires, there have been renewed activities in developing superconducting power equipment. HTS equipments have to be operated in a coolant such as liquid nitrogen ($LN_2$) or cooled by conduction-cooling method such as using Gifford-McMahon (G-M) cryocooler to maintain the temperature below critical level. In this paper, the dielectric strength of some insulating materials, such as unfilled epoxy, filled epoxy, and polyimide in $LN_2$ was analyzed. Epoxy is a good insulating material but fragile at cryogenic temperature. The filled epoxy composite not only compensates for this fragile property but enhances its dielectric strength.

PICTS 방법에 의한 급속열처리시킨 반절연성 InP(100)에서 깊은준위에 관한 연구 (A Study on Deep Levels in Rapid Thermal Annealed PICTS Semi-Insulating InP(100) by PICTS)

  • 김종수;김인수;이철욱;이정열;배인호
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제10권8호
    • /
    • pp.800-806
    • /
    • 1997
  • The behavior of de levels in rapid thermal annealed Fe-doped semi-insulating InP(100) was studied by photoinduced current transient spectrocopy(PICTS). In bulk InP, T2(Ec-0.24 eV), T3(Ec-0.30 eV) and T5(Ec-0.62 eV) traps were observed. After annealing the T2 trap was annihilated at 20$0^{\circ}C$ and recreated at 35$0^{\circ}C$. T3 trap was not affected below 40$0^{\circ}C$. With increasing temperature the concentration of T5 trap reduced and it was annihilated at 30$0^{\circ}C$. However the T1(Ec-0.16 eV) and T4(Ec-0.42 eV) traps were began to appear at 40$0^{\circ}C$and these concentrations were increased with annealing temperature. The T1 and T4 traps seem to be related to the isolated phosphorus vacancy( $V_{p}$) and $V_{p}$-indium antisite( $V_{p}$- $P_{in}$ ) or $V_{p}$-indium interstitial( $V_{p}$-I $n_{I}$) respectiely.respectiely.

  • PDF

마이크로전자 응용에서의 저유전율 고분자 재료 (Low Dielectric Constant Polymeric Materials for Microelectronics Applications)

  • 이호영
    • 마이크로전자및패키징학회지
    • /
    • 제9권3호
    • /
    • pp.57-67
    • /
    • 2002
  • 반도체 칩의 신호처리속도를 향상시키기 위한 방법에는 세 가지가 있다. 첫 번째 방법은 금속배선의 배치(layout)를 바꾸는 것이고, 두 번째 방법은 배선으로 사용되는 금속의 비저항을 감소시키는 것이며, 세 번째 방법은 절연재료(insulating material)의 유전상수(dielectric constant)를 감소시키는 것이다. 첫 번째나 두 번째의 방법에 대해서는 많은 연구가 이루어졌고, 지금도 연구가 이루어지고 있다. 그러나 첫 번째나 두 번째의 방법을 통하여 얻을 수 있는 신호처리속도의 향상보다는 세 번째 방법을 통하여 얻을 수 있는 신호처리속도의 향상이 더 크다. 본 논문에서는 먼저 마이크로전자에 응용되기 위한 절연재료의 요구조건을 살펴보고, 지금까지 개발된 저유전율 고분자재료들을 간략하게 소개할 예정이다. 아울러 유전상수를 낮추기 위하여 최근 개발된 기공을 갖는 고분자재료들과 이들을 제조하기 위한 공정에 대해서도 간략하게 소개할 예정이다.

  • PDF

단열콘크리트의 레올로지 특성에 관한 실험적 연구 (An Experimental Study on the Rheology Characteristics of Insulating Concrete)

  • 류동우;지석원;전현규
    • 한국건설순환자원학회논문집
    • /
    • 제4권2호
    • /
    • pp.118-124
    • /
    • 2016
  • 본 연구는 단열성능 향상 재료의 타입별 단열콘크리트의 레올로지 특성을 분석하여 최적 유동설계 및 펌핑해석을 위한 기초자료로 활용하고자 하였다. 그 결과 경량골재 혼입시 항복응력이 큰 폭으로 감소한 것으로 나타났으며, 2 type의 경우 마이크로기포제 (MFA) + 규조토 미분말(DM)의 조합이 가장 이상적인 유동특성을 나타내었다. 또한 3 type의 경우 마이크로기포제(MFA) + 규조토 미분말(DM) + 경량골재(L)의 조합이 가장 우수한 유동특성을 나타내었다.

자외선 열화에 의한 에폭시 절연재료의 표면특성과 내트래킹성 (Surface Characteristics and Tracking Resistance of Epoxy Insulating Materials against Ultraviolet)

  • 조한구;유대훈;강형경
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.495-496
    • /
    • 2008
  • This paper describes the influence of Ultra-violet irradiation on time to tracking resistance of epoxy insulating materials by use of the inclined plane test. And, the influence of surface degradation was evaluated through several method such as measurement of contact angle, surface roughness, using a scanning electron microscopy. As the 1000 hours of the surface degradation with UV-CON, the flashover time decreases at different rates depending on epoxy resin and silicone rubber specimen. As the duration of the surface degradation with UV-CON is prolonged, the contact angle of epoxy resin decreases at the rate of degradation time, while that of silicone rubber was not exchanged. It is assumed that this phenomenon is related to the decrease in hydrophobicity of the surface of the materials. Also, as to epoxy resin, the decrease of hydrophobicity due to surface degradation with UV-CON is greater than that resulting from surface degradation with WOM. The UV radiation produced chalking and crazing on the surface of the insulating materials specimen.

  • PDF

Electrical characteristics of insulating materials for HTS bushing immersed in $LN_2$

  • Choi, J.H.;Kim, W.J.;Shin, H.S.;Kim, S.H.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권4호
    • /
    • pp.10-13
    • /
    • 2011
  • For the operation of high temperature superconducting (HTS) power equipments, it is necessary to develop insulating materials and high voltage (HV) insulation technology at cryogenic temperature of bushing. In this paper, the surface flashover characteristics of various insulating materials in $LN_2$ are studied. These results are studied at both AC and impulse voltage under a non-uniform field. The negative impulse breakdown voltage of GFRP is slightly higher than the positive impulse breakdown voltage. The use of glass fiber reinforced plastic (GFRP) and polytetrafluoroethylene (PTFE, Teflon) as insulation body for HTS bushing should be much desirable. Especially, GFRP is excellent material not only surface flashover characteristics but also mechanical characteristics at cryogenic temperature. The surface flashover is most serious problem for the shed design in $LN_2$ and operation of superconducting equipment.

크랙저항성(抵抗性)과 단열성(斷熱性)을 향상(向上)시킨 EVA칩 첨가 기포콘크리트의 려공법(旅工法) 연구(硏究) (A Study on Method of Construction for Foamed Concrete adding EVA Chip that improves the Resistance of Cracking and Capability of Insulating)

  • 이종식;안정찬;이종학
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 추계 학술논문 발표대회
    • /
    • pp.5-9
    • /
    • 2007
  • The construction method for Foamed-Concrete has not been important due to following process of construction work. However, according to the code about enhance of energy saving design policy and impact noise, noised isolation has been used in construction site so that the resistance for cracking and capability for insulating of Foamed-Concrete has been required. Therefore, new alternatives are demanded. Optimum mixing design, which can get the improvement of insulation and resistance of crack for Foamed-Concrete adding EVA chip, was derived and also the device, applying to construction site, was invented to equalize quality. This device can measure quantity of all input and placement, and show up the sum of placement and mixing design on a touch screen. This valuable construction method is friendly environment and recycling method because of using EVA chip, by-product of an EVA insole scrap burned or embedded, as a light-weight aggregate.

  • PDF

DC 리액터형 고온초전도한류기용 고온초전도자석의 권선 및 전류리드의 절연 (Insulation of Winding and Current Lead of the High-Tc Superconducting Magnets for DC Reactor Type SFCL)

  • 양성은;배덕권;전우용;김영식;김상현;고태국
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2003년도 추계학술대회 논문집
    • /
    • pp.226-229
    • /
    • 2003
  • Following the successful development of practical high temperature superconducting (HTS) wires, there has been renewed activity in the development of superconducting power equipments. HTS equipments must be operated in the coolant, such as liquid nitrogen (L$N_2$) or cooled by cooler, such as GM-cryocooler to maintain the temperature below critical temperature. In this paper, dielectric strength of some insulating materials, such as epoxy, teflon, and glass fiber reinforced plastic (GFRP) in L$N_2$was measured. Surface breakdown voltage of GFRP which is basic property in design of HTS solenoid coil was measured. Epoxy is a goof insulating material but it is fragile at cryogenic temperature. The multi-layer insulating method of current lead is suggested to compensate this fragile property. It consists of teflon tape layer and epoxy layer fixed with texture. Based on these measurements, the 6.6㎸ class HTS magnet for DC reactor type high-T$_{c}$ superconducting fault current limiter (SFCL) was successfully fabricated and tested.d.

  • PDF

Pd-MIS 소자의 수소가스 검지 특성 (Characteristics of Pd-MIS devices on hydrogen gas sensing)

  • 이철환;조원일;신치범;윤경석;주재백
    • 한국수소및신에너지학회논문집
    • /
    • 제3권2호
    • /
    • pp.17-24
    • /
    • 1992
  • Hydrogen gas sensors were fabricated after the form of metal/insulator/semiconductor(MIS) structure on a p-type silicon wafer and a insulating layer (silicon dioxide) thickness was changed from $500{\AA}$ to $5000{\AA}$. Their electrical properties were investigated with the variation of the hydrogen gas concentration at room temperature. At the applied forward bias of lV to both ends of Pd-MIS sensors the current was decreased logarithmically with the increase of hydrogen concentration in air. In the case of a thin $SiO_2$ layered ($500{\AA}$) sensor the current ratio was decreased to 25 % at 1 % of hydrogen concentration in air and 50% for a thick $SiO_2$ layered ($5000{\AA}$) sensor. And the response time of the thick insulating layered sensor to 1% hydrogen containing air was about 50 seconds and regeneration time was 2.5 minutes. When a 0.5mA current was appied to the thick insulating layered sensor the maximun voltage shift was calculated to 0.8V in the case of ${\theta}$ = 1 and the Pd surface coverage of hydrogen was increased logarithmically with hydrogen partial pressure.

  • PDF