• 제목/요약/키워드: Insulated switchgear

검색결과 234건 처리시간 0.022초

에폭시 수지를 이용한 전기 절연물의 기계적 해석 방법에 관한 연구 (The Study of Mechanical Analysis for Electric Insulator using Epoxy Resign)

  • 정대석;박창우;조정환;김정배
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.192-193
    • /
    • 2007
  • Epoxy resign is used to insulate electricity in the gas insulated switchgear. There were many research to find out characteristics of the epoxy resign. But there is a poor research for the mechanical investigations. In this paper, we made an experiment and evaluated mechanical properties with specimens of the epoxy resign. Using Spacer which is a part of high voltage switchgear, and we studied the structural analysis methods and made an overture a how to analysis in order to solve problems.

  • PDF

진공 인터럽터의 쉴드 형상 최적설계 (Optimal Design of a Shield in Vacuum Interrupter)

  • 최승길;김규호
    • 한국전기전자재료학회논문지
    • /
    • 제20권4호
    • /
    • pp.374-380
    • /
    • 2007
  • In this paper a nobel optimum design method is presented for a shield in a vacuum interrupter which is equipped in switchgear to improve its electric insulation capability. The design of Taguchi experiment method which is based on the results by finite element method is used to find optimum design conditions. The important design factors are chosen at first and the concept of signal to noise ratio is applied to evaluate the vacuum interrupter performance, and the optimal values of each parameters are determined. From the results of various analyses, it is shown that the shield plate in circuit circuit breaker compartment of switchgear can reduce the concentration of electric field intensity. This method is very useful to design the construction of a shield in a short time. Consequently, the insulation capability of circuit breaker compartment in a gas insulated switchgear is improved by adopting an additional optimized shaped shield.

가스절연 구조에서 단일 부분방전펄스 분석에 의한 결함 판별 (Identification of Defect Type by Analysis of a Single PD Pulse in Gas Insulated Structure)

  • 조향은;김선재;정기우;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제28권5호
    • /
    • pp.320-325
    • /
    • 2015
  • This paper dealt with a defect identification algorithm which is based on single partial discharge (PD) pulse analysis in gas insulated structure. Four types of electrode systems such as a needle-plane, a plane-needle, a free particle and a crack inside spacer were fabricated to simulate defects in gas insulated switchgear (GIS). We measured single PD pulse by an oscilloscope with a sampling rate of 5 GS/s and a frequency bandwidth of 1 GHz. Data aquisition and signal processing were controlled by a LabVIEW program. Physical shapes of PD pulses were compared with kurtosis, skewness and time-based parameters as rising time, falling time and pulse-width. These parameters were analysed by an algorithm with a back propagation algorithm (BPA). By applying the algorithm, the identification rate was 97% for the needle-plane electrode, 96% for the plane-needle electrode, 91% for the free particle and 93% for the crack inside spacer. The results verified that the algorithm could identify the type of defects in GIS.

가스절연 개폐장치의 진단기술 지도 (Technology Road Map on Predictive Diagnosis for Gas Insulated Switchgear)

  • 윤진열;구선근;박기준;한기선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.2-3
    • /
    • 2005
  • 국내 전기설비진단연구회에서 GIS 고장을 예방할 목적으로 고안한 예방진단 기술지도 초안을 바탕으로하여 결함의 종류와 진단기술의 종류, 년도별 기술 개발 목표, 기술지도 등을 제시하였다.

  • PDF

$SF_6$ Gas Insulation for next Generation GIS

  • Endo, Fumihiro
    • E2M - 전기 전자와 첨단 소재
    • /
    • 제11권10호
    • /
    • pp.13-18
    • /
    • 1998
  • Many factors influence SF6 insulation and a number of them have been clarified quantitatively. For the next generation of gas-insulated switchgear (GIS), quantitative considerations of these factorsare necessary to enhance reliability and to make GIS more compact. Advanced insulation technology this purpose is described.

  • PDF

적층된 에폭시 고체유전체와 도전성 파티클에 대한 Dry-Air의 연면방전특성 (Surface Discharge Characteristics in Dry-Air on Laminated Epoxy Solid Dielectrics and Conductive Particle)

  • 임동영;전종철;배성우;이광식;박원주
    • 조명전기설비학회논문지
    • /
    • 제30권2호
    • /
    • pp.93-101
    • /
    • 2016
  • This paper presents the surface discharge characteristics in Dry-Air on laminated epoxy solid dielectrics and conductive particles in order to provide the valuable information for the insulation design of eco- friendly gas insulated switchgear. To improve insulation performance, the three types of the laminated epoxy solid dielectrics were proposed, and it was revealed that their surface discharge characteristics were similar to the bakelite dielectrics of same-laminated types. From the surface discharge characteristics of dry air, it was demonstrated that the effect of conductive particles on surface discharge voltage was dominant when there are this particles at the shortest electrode gap and that the degradation of insulation performance on the conductive particles was evident in epoxy than teflon. These phenomena were interpreted in terms of particle-triggered discharge mechanism and electric field of triple junction, respectively.

전자충돌과정을 통한 SF6 혼합기체의 절연특성 분석 (The Analysis of Insulation Properties with Electron Collision Processes on SF6 Mixture Gases)

  • 소순열
    • 전기학회논문지P
    • /
    • 제59권2호
    • /
    • pp.197-201
    • /
    • 2010
  • $SF_6$ gas would be used in power transformer, GIS (Gas insulated switchgear) and so on because of its electrically superior insulation and chemically stable structure. Recently, the reduction of $SF_6$ is required to avoid global warming and the researches on the dilution of $SF_6$ with other gases have been carried out. $SF_6$ mixture gases with $N_2$ and $C_xF_y$ have drawn attention to the synergy effect. However, in order to understand the mechanism of the synergy effect, it is important to analyze and evaluate properties of mixture gases quantitatively. In this paper, we investigated the mechanism of synergy effect from electron collision processes and electron energy distribution by solving Boltzmann equation with propagator method. Three kinds of gases for dilution of $SF_6$ ($SF_6/N_2$, $SF_6/CF$4 and $SF_6/C_4F_8$) are considered in this simulation. On the properties of $SF_6/N_2$ mixture gas, the variation of reduced electric field was shown highly within 0%~40% mixtures of $SF_6$. And the more low-level electron energy has been distributed, the higher insulation capability has appeared.

NURB 곡선을 이용한 가스절연 원통형 관로 내에서의 전계 최적화 (Electric Field Optimization using the NURB curve in a Gas-Insulated Switchgear)

  • 한인수;김응식;민석원;이준호;박종근;이태형;박춘수
    • 전기학회논문지
    • /
    • 제58권3호
    • /
    • pp.548-558
    • /
    • 2009
  • This paper attempts to develop an algorithm which optimizes the electric field through the so-called NURB(Non-Uniform Rational B-spline) curve in order to improve the insulation capacity. In particular, the NURB curve is a kind of interpolation curve that can be expressed by a few variables. The electric field of a conductor is computed by Charge Simulation Method(CSM) while that of a spacer by Surface Charge Method(SCM); this mixed calculation method is adopted for the electric field optimization. For calculation of the initial and optimal shapes, the Gauss-Newton method, which is quite easy to formulate and has slightly faster convergence rate than other optimization techniques, was used. The tangential electric field, the total electric field, and the product of the tangential electric field and area (Area Effect) were chosen as the optimization objective function by the average value of electric field for the determined initial shape.

A Study on the Condition Monitoring for GIS Using SVD in an Attractor of Chaos Theory

  • J.S. Kang;Kim, C.H.;R.K. Aggarwal
    • KIEE International Transactions on Power Engineering
    • /
    • 제4A권1호
    • /
    • pp.33-41
    • /
    • 2004
  • Knowledge of partial discharge (PD) is important to accurately diagnose and predict the condition of insulation. The PD phenomenon is highly complex and seems to be random in its occurrence. This paper indicates the possible use of chaos theory for the recognition and distinction concerning PD signals. Chaos refers to a state where the predictive abilities of a systems future are lost and the system is rendered aperiodic. The analysis of PD using deterministic chaos comprises of the study of the basic system dynamics of the PD phenomenon. This involves the construction of the PD attractor in state space. The simulation results show that the variance of an orthogonal axis in an attractor of chaos theory increases according to the magnitude and the number of PDs. However, it is difficult to clearly identify the characteristics of the PDs. Thus, we calculated the magnitude on an orthogonal axis in an attractor using singular value decomposition (SVD) and principal component analysis (PCA) to extract the numerical characteristics. In this paper, we proposed the condition monitoring method for gas insulated switchgear (GIS) using SVD for efficient calculation of the variance. Thousands of simulations have proven the accuracy and effectiveness of the proposed algorithm.

72.5kV 가스절연차단기(Gas Insulated Switchgear)의 내진해석 (The Seismic Analysis of 72.5kV Gas Insulated Switchgear(GIS))

  • 이성호;조상순;강성모;안길영;방재동;민길식;최종웅;윤시수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.762-764
    • /
    • 2001
  • In order to evaluate the structural safety from an earthquake, the seismic analysis of large structures such as GIS in electric power substations and equipments for nuclear power plant has been carried out because the seismic qualification by experiment is very expensive. This paper presents the seismic analysis of the 72.5kV GIS produced by LGIS. The finite element model of the GIS is developed and analyzed using ANSYS. The model consists of beam elements for the enclosures and mass elements for the conductors and the mechanisms. Using the transient analysis under seismic load, the structural safety is verified.

  • PDF