• Title/Summary/Keyword: Instrument Panel

Search Result 129, Processing Time 0.028 seconds

TRIO-CINEMA의 시스템 harness

  • Jeon, Je-Heon;Lee, Hyo-Jeong;Chae, Gyu-Seong;Seon, Jong-Ho;Jin, Ho;Lee, Dong-Hun;Lin, Robert P.;Immel, Thomas
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.199.1-199.1
    • /
    • 2012
  • TRIO-CINEMA(TRiplet Ionospheric Observatory-Cubesat for Ion, Neutron, Electron & MAgnetic field)는 지구근접공간에서의 미세 자기장 변화 및 중성입자의 검출을 목적으로 경희대학교와 UC Berkeley가 공동 개발하는 초소형위성이다. 초소형위성은 내부 공간이 협소하여 효율적인 공간배치 및 위성체발사 시 진동에도 견딜 수 있도록 harness가 제작되어야 한다. CINEMA는 OBC, EPS, 배터리, 수신기, IIB(Instrument Interface Board), MAGIC(MAGnetometer Imperial College) board, HVPS(High Voltage Power Supply)로 구성된 avionics bus와 MAGIC, STEIN(Supra Thermal Electron, Ion, Neutral)의 payload, Solar panel, UHF와 S-band 안테나로 구성되어 있다. Solar panel에서 생산된 전력은 EPS를 통해 배터리에 저장되고 PC104를 통해 avionics stack의 각 board로 전력이 분배된다. IIB는 탑재체 파트와 연결되어 이를 제어하고 HVPS에서 STEIN에 공급되는 고전압은 특수 와이어를 통해 연결되며 UHF 안테나와 S-band 안테나는 RF 케이블로 수신기와 송신기가 연결되어 있다. 각각의 harness는 케이블타이와 lacing tape로 위성체와 고정되며 커넥터는 고정 지지대를 제작하여 나사로 체결하였다. CINEMA에 적용된 harness는 진동시험과 열진공시험을 통해 harness와 시스템의 안정성이 검증 되었다.

  • PDF

A study on the measuring health literacy in patients with diabetes in Korea (당뇨병 환자의 건강정보이해능력 측정을 위한 기초 연구)

  • Kang, Soo Jin;Sim, Kang Hee;Chang, Soo Jung;Lee, Mi Sook
    • Korean Journal of Health Education and Promotion
    • /
    • v.33 no.5
    • /
    • pp.47-57
    • /
    • 2016
  • Objectives: To develop and evaluate the applicability of a health literacy instrument in patients with diabetes by measuring their ability to understand diabetes-related words. Methods: Diabetes-related words were extracted from the Korean Diabetes Association's website and literature reviews. In the first phase, three nursing researchers evaluated 2,661 diabetes-related words based on graded lexical vocabularies and what patients need to know about self-care, and the narrowed them to 255 words. In the second phase, a content validity assessment was conducted by an expert panel. In the third phase, the remaining 25 words were administered to 200 conscientious with type 2 patients aged 40 years old and using a Gallup survey from March 3 to 17, 2016 in Seoul, Korea. Descriptive analysis and Rasch analysis were performed to test psychometric properties. Results: The mean score was 21.47 with a range of 0 to 25. The Cronbach's ${\alpha}$ was .92. The health literacy instrument using diabetes-related words had a ceiling effect response. Conclusions: Diabetes-related words are useful and reliable items for testing the health literacy of diabetes patients. Future study is needed to develop and validate health literacy measures for diabetic patients.

Reliability and Validity of an Instrument Assessing Spiritual Needs of Families of Terminal Cancer Patients (말기 환자 가족 영적요구 측정도구의 신뢰도 및 타당도 검증)

  • Kang, Kyung-Ah;Choi, Youngsim;Kim, Yejean
    • Journal of Hospice and Palliative Care
    • /
    • v.21 no.4
    • /
    • pp.144-151
    • /
    • 2018
  • Purpose: The purpose of this study was to test the reliability and validity of an instrument that measures spiritual needs of families of terminal cancer patients. Methods: This methodological study was processed as follows: 1) The preliminary 26 items were developed based a conceptual framework of spiritual needs of families of patients with cancer. 2) The content was validated by an expert panel (Three nursing professors and five hospice nursing specialists). 3) The instrument was validated by a survey (n=111). 4) Twenty-six items were selected and used for the final version of the scale. Results: Three factors were extracted through factor analysis: 'relationship with God/Acceptance of dying', 'recovery of relationship/hope and peace', and 'meaning and purpose of life'. These factors explained 61.088% of the total variance. Cronbach's alpha and Guttman split-half coefficient of the 26 items were 0.944 and 0.826 respectively. Conclusion: This scale was identified as a valid and reliable tool. Therefore, the scale is useful in assessing spiritual needs of families of terminal cancer patients in the field of hospice and palliative care.

Reliability and Validity of an Instrument Assessing Advance Directives for Nurse (간호사의 사전의사결정 태도측정 도구의 신뢰도 및 타당도 검증)

  • Cheon, Hojung;Kim, Eunha
    • Journal of Hospice and Palliative Care
    • /
    • v.22 no.3
    • /
    • pp.134-143
    • /
    • 2019
  • Purpose: This methodological study was conducted to test the reliability and validity of an instrument that measures attitudes of advance directives (ADs) among nurses. Methods: 1) Sixteen items related to attitudes in the English version of the Knowledge, Attitudinal, and Experiential Survey on Advance Directives (KAESAD) were forward/backward translated into Korean. 2) The content was validated by an expert panel (three nursing professors and eight hospice nursing specialists). 3) The preliminary 12 items were selected as a tool to assess the Korean version of Nurses' Attitudes towards Advance Directives (NAAD-K). 4) The instrument was validated by a survey (n=216). 5) It was confirmed to use the 12 items for the final version of the instrument. Results: NAAD-K was shown to be valid in terms of factors, items and content. The three factors extracted from the factor analysis were named as follows: Caring for patients with an AD (factor 1), nurses' role in informing patients (factor 2) and patient right (factor 3). The three factors explained total variance 57.796%. Factor loadings of the 12 items ranged from 0.47 to 0.93. For the 12 items, Cronbach's alpha was 0.81, and Guttman split-half coefficient was 0.78. Conclusion: This instrument was identified to be applicable with satisfactory reliability and validity for further use in measuring nurses' attitudes towards ADs in hospice and palliative care.

The Government Expenditure Multiplier in Korea : Evidence From Input-Output Table Panel Data (산업연관표 패널 자료를 이용한 정부지출 승수 추정)

  • Hong, Minki
    • Economic Analysis
    • /
    • v.27 no.3
    • /
    • pp.33-60
    • /
    • 2021
  • This study estimates the fiscal multiplier using Input-Output table panel data from year of 2010 to 2018. Considering the endogeneity of the government expenditure, this study uses the share of government expenditure by sector in the initial period as an instrument variable. The estimation from the panel fixed effect instrumental variables model shows that the estimate for the current period of government expenditure is 1.15~1.22 and the estimate for the cumulative multiplier is 1.23~1.32 depending on the method of controlling time trend. Since the general equilibrium effect absorbed by the time-fixed effect in the estimation equation, the estimated multiplier in this study may be different from the multiplier of the economy as a whole. The general equilibrium effect depends on the response of monetary policy, changes in tax policy, and interaction between sectors.

A basic research for evaluation of a Home Care Nursing Delivery System (가정간호 서비스 질 평가를 위한 도구개발연구)

  • Kim, Mo-Im;Cho, Won-Jung;Kim, Eui-Sook;Kim, Sung-Kyu;Chang, Soon-Bok;Ryu, Ho-Sihn
    • Journal of Home Health Care Nursing
    • /
    • v.6
    • /
    • pp.33-45
    • /
    • 1999
  • The purpose of this study was to develop a basic framework and criteria for evaluation of quality care provided to patients with the attributes of disease in the home care nursing field, and to provide measurement tools for home health care in the future. The study design was a developmental study for evaluation of hospital-based HCN(home care nursing) in Korea. The study process was as follows: a home care nursing study team of College of Nursing. Yonsei University reviewed the nursing records of 47 patients who were enrolled at Yonsei University Medical Center Home Care Center in March, 1995. Twenty-five patients were insured at that time, were selected from 47 patients receiving home care service for study feasibility with six disease groups; Caesarean Section (C/S), simple nephrectomy, Liver cirrhosis(LC), chronic obstructive pulmonary disease(COPD), Lung cancer or cerebrovascular accident(CVA). In this study, the following items were selected : First step : Preliminary study 1. Criteria and items were selected on the basis of related literature on each disease area. 2. Items were identified by home care nurses. 3. A physician in charge reviewed the criteria and content of selected items. 4. Items were revised through preliminary study offered to both HCN patients and discharged patients from the home care center. Second step : Pretest 1. To verify the content of the items, a pretest was conducted with 18 patients of which there were three patients in each of the six selected disease groups. Third step : Test of reliability and validity of tools 1. Using the collected data from 25 patients with either cis, Simple nephrectomy, LC, COPD, Lung cancer, or CVA. the final items were revised through a panel discussion among experts in medical care who were researchers, doctors, or nurses. 2. Reliability and validity of the completed tool were verified with both inpatients and HCN patients in each of field for researches. The study results are as follows: 1. Standard for discharge with HCN referral The referral standard for home care, which included criteria for discharge with HCN referral and criteria leaving the hospital were established. These were developed through content analysis from the results of an open-ended questionnaire to related doctors concerning characteristic for discharge with HCN referral for each of the disease groups. The final criteria was decided by discussion among the researchers. 2. Instrument for measurement of health statusPatient health status was measured pre and post home care by direct observation and interview with an open-ended questionnaire which consisted of 61 items based on Gorden's nursing diagnosis classification. These included seven items on health knowledge and health management, eight items on nutrition and metabolism, three items on elimination, five items on activity and exercise, seven items on perception and cognition, three items on sleep and rest, three items on self-perception, three items on role and interpersonal relations, five items on sexuality and reproduction, five items on coping and stress, four items on value and religion, three items on family. and three items on facilities and environment. 3. Instrument for measurement of self-care The instrument for self-care measurement was classified with scales according to the attributes of the disease. Each scale measured understanding level and practice level by a Yes or No scale. Understanding level was measured by interview but practice level was measured by both observation and interview. Items for self-care measurement included 14 for patients with a CVA, five for women who had a cis, ten for patients with lung cancer, 12 for patients with COPD, five for patients with a simple nephrectomy, and 11 for patients with LC. 4. Record for follow-up management This included (1) OPD visit sheet, (2) ER visit form, (3) complications problem form, (4) readmission sheet. and (5) visit note for others medical centers which included visit date, reason for visit, patient name, caregivers, sex, age, time and cost required for visit, and traffic expenses, that is, there were open-end items that investigated OPD visits, emergency room visits, the problem and solution of complications, readmissions and visits to other medical institution to measure health problems and expenditures during the follow up period. 5. Instrument to measure patients satisfaction The satisfaction measurement instrument by Reisseer(1975) was referred to for the development of a tool to measure patient home care satisfaction. The instrument was an open-ended questionnaire which consisted of 11 domains; treatment, nursing care, information, time consumption, accessibility, rapidity, treatment skill, service relevance, attitude, satisfaction factors, dissatisfaction factors, overall satisfaction about nursing care, and others. In conclusion, Five evaluation instruments were developed for home care nursing. These were (1)standard for discharge with HCN referral. (2)instrument for measurement of health status, (3)instrument for measurement of self-care. (4)record for follow-up management, and (5)instrument to measure patient satisfaction. Also, the five instruments can be used to evaluate the effectiveness of the service to assure quality. Further research is needed to increase the reliability and validity of instrument through a community-based HCN evaluation.

  • PDF

Analysis of the ODA impact that Donor's Exports - Focus on Korean Technology Cooperation ODA (ODA가 공여국의 수출에 미치는 영향 분석 - 한국의 기술협력 ODA를 중심으로)

  • Byun, Sejun;Choi, Jaeyoung
    • Journal of Technology Innovation
    • /
    • v.27 no.2
    • /
    • pp.99-122
    • /
    • 2019
  • ODA (Official Development Assistance) aims for practicing international humanitarianism in developing countries. However, ODA donors also seek to find convincing evidence meeting the national economic & political interests in the international community. In this regards, precise & unbiased estimation of the policy effects of ODA aid on the donors' exports to the recipient countries has recently become one of the primary concerns of the ODA donors, especially developing countries including Korea of which economy structure heavily relies on exports for economic growth. Based on the basic gravity model, this study empirically analyzes the effects of technical cooperation ODA delivering skills, knowledge and technical know-how on Korea's exports to the ODA recipient countries using 10-year panel data from 2007 to 2016. Specifically, by incorporating major variables affecting trade such as GDP, distance, FDI etc, the effect of technical cooperation ODA on Korea's exports to the ODA recipient countries is estimated with various kinds of panel models. As a result, technical cooperation ODA has a statistically significant impact on Korea's exports to ODA recipient countries, especially in the exports of intermediate goods. And the detail process of this black-boxed mechanism is scrutinized through case studies on Uzbekistan, The Philippines, and Morocco.

A Study on Foaming Characteristics of Polyurethane Reaction Injection Molding using Cup Foam Test (컵 발포시험을 이용한 폴리우레탄 반응사출성형의 발포 특성에 관한 연구)

  • Youn, J.W.;Kim, H.S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.10a
    • /
    • pp.106-109
    • /
    • 2008
  • Polyurethane has been one of the most important materials for automobile elastic parts such as bumper, head rest, instrument panel and so on since it covers very wide range of mechanical characteristics with low production costs. The process variables such as formulation of ingredients and mold temperature, mixing speed, etc. can affect the quality of produced polyurethane foams so that process conditions should be determined appropriately. In this study, foaming behaviors of semi-rigid polyurethane were investigated by conducting cup foam tests with 2 major process variables such as environmental temperature and blowing agent content.

  • PDF

Telerobot System for Carrying FPD (FPD 운반을 위한 텔레로봇 시스템)

  • Igor, Gaponov;Jo, Hyeon-Chan;Kim, Jong-Won;Khalis, Totorkulov;Choe, Seong-Ju
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2007.04a
    • /
    • pp.135-138
    • /
    • 2007
  • In this paper, intelligent filtering methodology for masterarm translation signal is proposed. Fidelity and stability are contradicting factors in teleoperation. Human hand trembling filtering is one of the problems in telemanipulation field. During every operation the hand has a certain vibration that can affect the quality of teleoperation, especially in carrying FPD (Flat Panel for Display), nanomanipuation and other precise tasks. It is very important to study the kinesthetic perception of the human and to optimize the teleoperation system accordingly. To cancel out the influence of human's hand vibration the signal from the masterarm should be filtered. One of the feasible solutions is to use an intelligent filter, which is a very flexible instrument. Applying intelligent filtering methodology, we can use some heuristic methods to solve the filtering problem.

  • PDF

Relation of Luminance by Insulator and Phosphor Layer with Thin Type (형광층 및 절연층의 두께에 의한 휘도특성)

  • 박수길;조성렬;손원근;박대희;이주성
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.11a
    • /
    • pp.85-88
    • /
    • 1998
  • Light-emitting diode(LEDs), diode arrays, and phosphor display panels are finding increased use in a variety of commercial applications. Present and anticipated application of these devices include solid state indicator(e.g., digital clocks, meter readout) and display systems(e.g., instrument panels, TV display), the application being determined by the light -output capability and size availability(cost) of the particular device. In this work, Phosphor based on ZnS:Cu are used. Relation by luminance with the thickness of insulating layer and phosphor layer are discussed. Increased thickness of insulating layer are stable on voltage to 300V. By considering thickness and voltage, optimal structure and thickness are investigated. Also in order to maximize even surface emission, various sieving process are introduced. Very similar phosphor particle size is selected. Luminance by various wave intensity is also investigated. 150cd/m$^2$ luminance are investigated in stable voltage and frequency.

  • PDF