• Title/Summary/Keyword: Instantaneous reactive power

Search Result 103, Processing Time 0.022 seconds

Sensorless speed Control of a Permanent Magnet Synchronous Motor based on an Instantaneous Reactive Power in the Field-Weakening Region (약계자 제어 영역에서의 순시무효전력을 이용한 영구자석 동기전동기의 센서리스 속도제어)

  • Lee Jeong-Hum;Kim Young-Seok;Choi Yang-Kwang;Kim Dai-Hyun
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.926-928
    • /
    • 2004
  • For the permanent magnet synchronous motor(PMSM) drive to operate above the base speed in the constant horsepower region, field weakening control is applied. But field weakening control was not almost applied to sensorless control of the permanent magnet synchronous motor. In this paper, field weakening control is applied to the sensorless control of PMSM based on an instantaneos reactive power. And the effectiveness of the proposed system is verified by the experimental results.

  • PDF

A Study on the Unity Power Factor Converter to Inhibit Harmonics of Distributed Line (배전선로의 고조파 성분억제가 가능한 단위역률 전력변환기 개발에 관한 연구)

  • 박성준;변영복;권순재;김철우
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.5
    • /
    • pp.57-63
    • /
    • 1995
  • In this paper, 3-Phase PWM AC/DC step up type converter that reduces the harmonics and reactive power of the distribution line is analyzed and the stable control method is proposed as controlling the sinusoidal phase current and phase voltage in phase. In implementation of controller, simple control algorithm is derived as the instantaneous voltage control methods without current sensor. The instantaneous voltage is controled by PWM method and the switching frequency is presented in low range 3 [kHz] for reducing the switching loss. In case of active load, four quadrants operation converter regenerate power from the load to the power source is conducted. Through the computer simulation and experimentation, the proposed control method is justified.

  • PDF

A Control Algorithm of Single Phase Active Power Filter based on Rotating Reference Frame (회전좌표계를 이용한 단상능동전력필터의 제어이론)

  • Kim, Jin-Sun;Kim, Young-Seok;Shin, Jae-Hwa
    • Proceedings of the KIEE Conference
    • /
    • 2005.07b
    • /
    • pp.1480-1482
    • /
    • 2005
  • The major causes of power quality deterioration are harmonic current through semiconductor switching device, due to use of nonlinear loads such as diodes rectifier or thyristor rectifiers. In response to this concerns, this paper presents a new control method of single-phase active power filter(APF) for the compensation of harmonic current components in nonlinear loads. In order to make the complex calculation to be possible, the single-phase system that has two phases was made by constructing a imaginary second-phase giving time delay to load currents. In the conventional method, a imaginary-phase lagged to the load current T/4(here T is the fundamental cycle) was made. But in this proposed method, the new signal, which has the delayed phase through the filter, using the phase-delay property of low-pass filter, was used as the second phase. As this control method is applied to the system of single phase, an instantaneous calculation was done rather by using the rotating reference frames that synchronizes with source-frequency than by applying instantaneous reactive power theory that uses the conventional fixed reference frames.

  • PDF

Performance Analysis of UPQC(Unified Power Quality Conditioner) with Compensation Capability for Voltage Interruption (순간정전에 대한 보상능력을 갖는 UPQC(Unified Power Quality Conditioner)의 성능해석)

  • 김희중;배병열;한병문;설승기;조보형
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.52 no.5
    • /
    • pp.279-286
    • /
    • 2003
  • A new UPQC(unified power quality conditioner), which consists of series inverter, shunt inverter, dc/dc converter, and energy storage, is proposed. The proposing UPQC can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance, and voltage interruption. The control strategy for the proposing UPWQC was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the EMTDC/PSCAD simulation and the experimental work with the hardware prototype. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems or industrial power systems and can be utilized for the custom power device in the future distribution system.

Performance Analysis for the UPQC(Unified Power Quality Conditioner) Interconnected to the Distributed Generation System (분산전원 연계형 UPQC(Unified Power Quality Conditioner)의 성능해석)

  • 김희중;배병열;한병문
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.3
    • /
    • pp.152-160
    • /
    • 2004
  • A novel UPQC(Unified Power Quality Conditioner), which consists of series inverter, shunt inverter, distributed generation system, is proposed. The proposing system can compensate reactive power, harmonics, voltage sag and swell, voltage interruption etc. through the change of paralleling operation mode and islanding operation mode. The control strategy for the proposing system was derived using the instantaneous power method. The performance of proposing system was analyzed by means of the PSCAD/EMTDC simulation and the experimental work with the hardware prototype. The proposing system has the ultimate capability of improving power quality at the point of installation on power distribution systems or Industrial power systems and can be utilized for the custom power device in th future distribution system.

Operation Analysis of Novel UPQC(Unified Power Quality Conditioner) without Series Injection Transformers (직렬주입변압기가 없는 새로운 UPQC(Unified Power Quality Conditioner)의 성능분석)

  • Kim H.J.;Bae B.Y.;Jon Y.S.;Han B.M.;Kim H.W.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.251-255
    • /
    • 2003
  • This paper proposes a novel UPQC(unified power quality conditioner) based on H-bridge modules, isolated through single-phase multi-winding transformers. The dynamic performance of proposed system was analyzed by simulation with EMTDC/PSCAD, assuming that the UPQC is connected with the 22.9kV distribution line. The proposed system can be directly connected to the transmission line without series injection transformers. It has flexibility in expanding the operation voltage by increasing the number of H-bridge modules and can compensate reactive power, harmonics, voltage sag and swell, voltage unbalance. The control strategy for the proposing UPQC was derived using the instantaneous power method. The proposing UPQC has the ultimate capability of improving power quality at the point of installation on power distribution systems and can be utilized for the future distribution system.

  • PDF

Modeling of shunt active power filter using PSCAD/EMTDC

  • Vu, Trung-Kien;Seong, Se-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2009.11a
    • /
    • pp.293-295
    • /
    • 2009
  • In this paper, a shunt active power filter (SAPF) has been used to eliminate the harmonic distortion and to improve the power quality of three-phase grid-connected power conditioning system (PCS). The adopted control strategy in active power filter system is based on the instantaneous reactive power theory (P-Q theory). Based on the theoretical analysis, the overall system of three-phase grid-connected with non-linear load PCS has been built and modeled using PSCAD$^{(R)}$/EMTDC$^{TM}$. The simulation results are shown to verify the high effective performance of the implemented SAPF in power system and to verify the reasonableness of the system structure.

  • PDF

Diagnostic and Active Filtering of Harmonics Generated by Compact Fluorescent Lamps

  • Moulahoum, Samir;Houassine, Hamza;Kabache, Nadir
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.162-168
    • /
    • 2014
  • Use of nonlinear loads, such as power converters, fluorescent lamps and adjustable speed motor drives, is expected to grow rapidly. All of these loads inject harmonic currents. This paper presents the active filtering of the harmonic distortion generated by the compact fluorescent lamps (CFL). The Instantaneous active and reactive power theory (the p-q Theory) is used to design the control of parallel active filter. The control scheme has been verified using Matlab/Simulink with SimPower Systems through a set of simulation tests under different load conditions. Also, the tuning of the active power filter is performed to improve the quality of the electrical power supply.

An Active Power Filter For A Compensation Of Power Factor and Harmonic Currents (역률개선 및 고조파 보상을 위한 능동전력필터)

  • Kim, Yong-Ho;Ahn, Bok-Shin
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.447-450
    • /
    • 1991
  • A novel effective calculation method of the compensation current commands of active power filter using voltage source PWM converter is proposed on the basis of the instantaneous reactive power theory. The load currents and the phase of the source voltages are used for the simplification of the calculations and the reduction of the its time. And the calculation of the currents is performed by DSP 32014 within 50 uSEC. For reducing the DC voltage and saving the costs, a passive power filters are used. The simulation results of the effects of the active power filter with a passive filter are presented.

  • PDF

CONTROL STRATEGIES FOR SHUNT ACTIVE POWER FILTERS IN DISTORTION SOURCE VOLTAGE SITUATION

  • Yang, Jun;Wang, Zhaoan
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.876-881
    • /
    • 1998
  • The compensation strategy of shunt active power filters is one of the most important link that determine its compensation characteristics. In this paper, a new interpretation of the instantaneous reactive power theory in three-phase circuits was proposed. A compensation strategy (ip, iq mode) was introduced on the basis of the new interpretation. This compensation strategy was compared with other two compensation strategies(P, q mode and UPF mode). When source voltage is distorted, a sinusoidal, the three compensation strategies are equivalent to each other. When source voltage is distorted, a sinusoidal source current may result only by using ip, iq mode. This is the advantage of ip, iq mode. The result is verified by simulation.

  • PDF