마운트 시스템을 갖는 유연 로터-베어링 시스템의 기초전달 충격 과도응답 해석을 위한 유한요소 모델링 (FE Modeling for the Transient Response Analysis of a Flexible Rotor-bearing System with Mount System to Base Shock Excitation)

  • 이안성;김병옥
    • 한국소음진동공학회논문집
    • /
    • 제17권12호
    • /
    • pp.1208-1216
    • /
    • 2007
  • Turbomachinery such as turbines, pumps and compressors, which are installed in transportation systems, including aircrafts, ships, and space vehicles, etc., often perform crucial missions and are exposed to potential dangerous impact environments such as base-transferred shock forces. To protect turbomachinery from excessive shock forces, it may be needed to accurately analyze transient responses of their rotors, considering the dynamics of mount designs to be applied. In this study a generalized FE transient response analysis model, introducing relative displacements, is proposed to accurately predict transient responses of a flexible rotor-bearing system with mount systems to base-transferred shock forces. In the transient analyses the state-space Newmark method of a direct time integration scheme is utilized, which is based on the average velocity concept. Results show that for the identical mount systems considered, the proposed FE-based detailed flexible rotor model yields more reduced transient vibration responses to the same shocks than a conventional simple model, obtained by treating a rotor as concentrated lumped mass, equivalent spring and a damper or Jeffcott rotor model. Hence, in order to design a rotor-bearing system with a more compact light-weighted mount system, preparing against any potential excessive shock, the proposed FE transient response analysis model herein is recommended.

A Mobile Object Tracking Scheme by Wired/wireless Integrated Street Lights with RFID

  • Cha, Mang Kyu;Kim, Jung Ok;Lee, Won Hee;Yu, Ki Yun
    • 대한공간정보학회지
    • /
    • 제24권2호
    • /
    • pp.25-35
    • /
    • 2016
  • Since a sophisticated location determination technology (LDT) is necessary for accurate positioning in urban area environments, numerous studies related to the LDT using the RFID (Radio Frequency IDentification) technology have been implemented for real-time positioning and data transferring. However, there are still lots of unsolved questions especially regarding what to use as base stations and what are corresponding results under the intrinsic complexity of alignment and configuration of components used for the RFID positioning. This study proposes the street light fixtures as base stations where the RFID receivers will be embedded for the mobile tracking scheme. As street light fixtures are usually installed at a certain distance interval, they can be used as base stations for the RFID receiver installation. Using the principle of the single row triangle network, the RFID receiver organization is determined based on the experiments such as recognition distance measurement and tag position accuracy estimation at inside and outside of the single row triangle network. The results verify that the mobile tracking scheme which uses RFID-embedded street light fixtures, suggested and configured in this study, is effective for the real-time outdoor positioning.

상용해석 툴을 이용한 소형 스크류 디캔터의 설계에 관한 연구 (A Study on Design of Small Type Screw Decanter using Commercial Analysis Tool)

  • 김용석;김종태;양순용
    • 드라이브 ㆍ 컨트롤
    • /
    • 제11권4호
    • /
    • pp.46-52
    • /
    • 2014
  • This study suggests a small-sized screw decanter specialized for dredging sites. Generally, conventional screw decanters are composed of a cylinder and a cone. However, the suggested screw decanter simply has a cone based on a cone-type bowl structure. In this research, a commercial analysis tool is used to establish an optimal design for the bowl and the screw conveyor. Moreover, the base frame, where the main bearings that support the spindle of the bowl and the screw conveyor are installed, is optimally designed considering the weight of the rotating body and the deflection caused by the high centrifugal force. Furthermore, the natural frequency range of the spinning body, the bowl and the screw conveyor, is applied to this base frame; it is designed not to correspond to the resonance frequency range and achieves stability as a result. This study suggests an optimal design for the rotating body and the base frame of a screw decanter considering its vibration characteristics. Such a design will prevent overuse of materials and help to reduce the weight and volume-and the price-of a screw decanter.

Application of AIS in AtoN Wireless Surveillance System

  • Liu, Chang;Liu, Ren-Jie;Shi, Xiao-Fei;Huang, Yao-Liang
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2006년도 Asia Navigation Conference
    • /
    • pp.129-133
    • /
    • 2006
  • In China, the traditional method of artificial and periodical cruise is still adopted for the AtoN management, which has brought many disadvantages to the work of the AtoN management, such as non real-time, fallibility, and low efficiency However, with the rapid development of AIS technique, now AIS equipments have been widely installed on ships, and on the other hand China Maritime Safety Administration (abr. China MSA) is carrying out the scheme of AIS base station network in china, based on which the digital AtoN will develop in the future. According to what have been analyzed above, this paper puts forward a design of AtoN wireless surveillance system based on AIS. The system consists of AIS on AtoN, AIS base station and AtoN management center. It can provide such functions as the information gathering, managing of AtoN and the service of navigation assistance. This paper gives the whole design including the work theory, the hardware structure and the software scheme of the system, and finally gives the simulation software of the AtoN management center. The AtoN wireless surveillance system brought forward by this paper will be more efficient with less repair cost and less work of the supervisors. It will bring revolutionary progress in the navigation aids system in China.

  • PDF

Effects of floating wave barriers on wave-induced forces exerted to offshore-jacket structure

  • Osgouei, Arash Dalili;Poursorkhabi, Ramin Vafaei;Hosseini, Hamed;Qader, Diyar N.;Maleki, Ahmad;Ahmadi, Hamid
    • Structural Engineering and Mechanics
    • /
    • 제83권1호
    • /
    • pp.53-66
    • /
    • 2022
  • The main objective of the present research was investigating the effects of a floating wave barrier installed in front of an offshore jacket structure on the wave height, base shear, and overturning moment. A jacket model with the height of 4.55 m was fabricated and tested in the 402 m-long wave flume of NIMALA marine laboratory. The jacket was tested at the water depth of 4 m subjected to the random waves with a JONSWAP energy spectrum. Three input wave heights were chosen for the tests: 20 cm, 23 cm, and 28 cm. Two different cross sections with the same area were selected for the wave barrier: square and rhombus. Results showed that the average decrease in the jacket's base shear due to the presence of a floating wave barrier with square and rhombus cross section was 24.67% and 34.29%, respectively. The use of wave barriers with square and rhombus cross sections also resulted in 19.78% and 33.11% decrease in the jacket's overturning moment, respectively. Hence, it can be concluded that a floating wave barrier can significantly reduce the base shear and overturning moment in an offshore jacket structure; and a rhombus cross section is more effective than an equivalent square section.

Load-settlement curve combining base and shaft resistance considering curing of cement paste

  • Seo, Mi Jeong;Park, Jong-Bae;Lee, Dongsoo;Lee, Jong-Sub
    • Geomechanics and Engineering
    • /
    • 제29권4호
    • /
    • pp.407-420
    • /
    • 2022
  • Embedded piles, which are typically used in Korea, are precast piles inserted into prebored ground with cement paste. Dynamic pile tests tend to underestimate the bearing capacity of embedded piles because of the undeveloped shaft resistance prior to the curing of the cement paste and the insufficient energy transferred after the curing. In this study, a resistance combination method using the base resistance before the cement paste is cured and the shaft resistance after the cement paste is cured is proposed to obtain a combined load-settlement curve from dynamic pile tests. Two pairs of embedded piles with diameters of 600 and 500 mm are installed. Each pair comprises one pile for the dynamic pile test and another pile for the static load test. The shape of the load-settlement curve obtained using the proposed method is similar to that obtained from the static load test. Thus, the resistances evaluated using the proposed method at selected settlements are similar to those obtained from the static load test. This study shows that the resistance combination method may be used effectively in dynamic pile tests to accurately evaluate the bearing capacity of embedded piles.

갈수기 지하수 물 사용량 저감 및 기저유출 수질 개선 방안 연구 (A Study on How to Reduce the Amount of Groundwater Used in the Dry Season and Improve the Water Quality of the Base Runoff)

  • 강태성;양동석;유나영;신민환;임경재;김종건
    • 한국농공학회논문집
    • /
    • 제64권2호
    • /
    • pp.27-35
    • /
    • 2022
  • Based on the current status of groundwater usage in the dry season through field surveys, this study tried to suggest countermeasures to reduce groundwater usage and to improve the water quality of baseflow from agricultural fields. For this purposes, basins with water curtain cultivation preceded were targeted where decreases of groundwater due to continuous use of groundwater in spring and winter annually observed. From monitoring groudwater usage of the study watershed, 130,058, 130,105 m3/day of water was pumped in during the water curtain cultivation period (October-February) in the Shindun, Seokwon watershed respectively. And the pilot application of the smart automated sensor-based water curtain cultivation system (smart WC system) developed in this study to reduce groundwater consumption has been conducted. As a result, the efficiency of the smart WC system when threshold temperature is set as 6.3 ℃ was 21.1% compared to conventional cultivation and efficiency increased as threshold temperature gets lower. Lastly, in this study, culvert drainage and Bio-filters were installed and rainfall monitoring was performed 15 times in order to analyze the baseflow securement and pollutant loads behavior. As a result, the test-bed with culvert drainage and Bio-filter installed together generated 61.4% more baseflow (4.974 m3) than the test-bed with only culvert drainage was installed (3.056 m3). However, the total pollutant load of all water quality contents (BOD, COD, T-N, TOC) except for the SS and T-P was found to be greater in the culvert drain and Bio-filter installed than in the culvert drain test-bed.

주구조물 및 부구조물에 대한 감진장치의 지진응답 감소 효율성 (Effectiveness of Isolation-System on Reduction of Seismic Response of Primary and Secondary Structures)

  • 김영상;이동근
    • 대한토목학회논문집
    • /
    • 제12권4_1호
    • /
    • pp.9-21
    • /
    • 1992
  • 논문에서는 주구조물의 기초와 부구조물의 지지점에 설치된 감진장치가 구조물의 지진응답 감소에 미치는 영향을 분석하였다. 여러가지 지진하중의 특성에 따른 감진장치가 설치된 주구조물과 부구조물의 거동을 비교분석하였으며, 이때 사용된 해석모델은 고정기초 구조물에 지지점이 고정된 부구조물, 감진기초 구조물에 지지점이 고정된 부구조물, 고정기초 구조물에 지지점 감진장치가 설치된 부구조물과 같은 세가지이다. 부구조물의 응답계산에서는 주구조물과 부구조물의 상호작용을 고려하였다. 계산에 사용한 수치적분방법은 constant average acceleration 방법이며, 이 방법과 축소행렬방법을 이용한 전산프로그램(KBISAP)을 사용하였다. 또한 지진하중에 대한 구조물의 지면에 대한 상대변위를 제한시키기 위하여 여러가지 지진하중에 대한 구조물의 가속도와 변위의 상관관계를 계산하여 감진장치의 적합한 수평강성을 분석하였다.

  • PDF

Real-time hybrid simulation of smart base-isolated raised floor systems for high-tech industry

  • Chen, Pei-Ching;Hsu, Shiau-Ching;Zhong, You-Jin;Wang, Shiang-Jung
    • Smart Structures and Systems
    • /
    • 제23권1호
    • /
    • pp.91-106
    • /
    • 2019
  • Adopting sloped rolling-type isolation devices underneath a raised floor system has been proved as one of the most effective approaches to mitigate seismic responses of the protected equipment installed above. However, pounding against surrounding walls or other obstructions may occur if such a base-isolated raised floor system is subjected to long-period excitation, leading to adverse effects or even more severe damage. In this study, real-time hybrid simulation (RTHS) is adopted to assess the control performance of a smart base-isolated raised floor system as it is an efficient and cost-effective experimental method. It is composed of multiple sloped rolling-type isolation devices, a rigid steel platen, four magnetorheological (MR) dampers, and protected high-tech equipment. One of the MR dampers is physically tested in the laboratory while the remainders are numerically simulated. In order to consider the effect of input excitation characteristics on the isolation performance, the smart base-isolated raised floor system is assumed to be located at the roof of a building and the ground level. Four control algorithms are designed for the MR dampers including passive-on, switching, modified switching, and fuzzy logic control. Six artificial spectrum-compatible input excitations and three slope angles of the isolation devices are considered in the RTHS. Experimental results demonstrate that the incorporation of semi-active control into a base-isolated raised floor system is effective and feasible in practice for high-tech industry.

자동복원 및 보강 시스템과 결합된 면진받침의 지진거동과 평가 (Seismic Behavior and Estimation for Base Isolator Bearings with Self-centering and Reinforcing Systems)

  • 허종완
    • 대한토목학회논문집
    • /
    • 제35권5호
    • /
    • pp.1025-1037
    • /
    • 2015
  • 지반과 상부 구조물 사이의 경계에서 유연성이 확보된 지진동 격리 받침 시스템을 설치한 후에 전체 구조물의 고유 주기를 연장하고 구조물에 전달되는 지진 가속도를 저감하여 구조물을 보호하는 면진 설계 방식이 최근 건설 현장에서 널리 활용되고 있다. 하지만 도심지의 현대 구조물이 점차 대형화 및 고층화 되면서 기존의 면진 받침을 그대로 사용하기에는 지진 발생시 저항 능력의 부족으로 인한 전단파괴 혹은 잔류변형이 발생하여 구조물의 사용성 향상을 위한 보수 및 붕괴 위험에 따른 철거의 문제점을 발생시킨다. 따라서 본 연구에서는 기존에 주로 사용되는 면진 받침의 저항 강도와 복원성을 향상시키기 위하여 부가적인 개장 시스템을 설치하고 지진 하중에 대한 성능을 평가하고자 한다. 초탄성 형상기억합금 소재의 보강 봉을 납 적층 고무 받침에 설치한 면진 시스템을 설계하고 단자유도 스프링 모델로 모형화하여 지진 데이터를 활용하고 비선형 동적 해석을 실시하였다. 본 연구에서 제안된 면진 시스템이 성능적인 우수성을 입증하기 위하여 기존에 사용된 면진 받침과 여기에 추가로 강재 봉으로 보강된 면진 시스템과의 극한 전단 저항력, 복원성 및 잔류변형 발생 등을 해석을 통하여 비교 평가하였다. 그 결과 초탄성 형상기억합금 소재의 제어 봉으로 보강된 면진 받침이 다른 면진 받침과 비교하여 지진저항 성능에 있어서 우수함을 확인하였다.