• 제목/요약/키워드: Installation qualification

검색결과 23건 처리시간 0.149초

생물안전 3등급 연구 시설의 검증 사례 (A Case Study of Biosafety Level-3 Research Facilities Validation)

  • 주영덕;김진손;손익수;노희전
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.887-892
    • /
    • 2009
  • Biosafety research facilities require to verified about the facility and experimental environment, especially for level-3 and level-4 of biosafety research facilities verification is very important. In this paper, introduce verified procedures and present the methods and the results through a verified case of the biosafety level-3 research facilities.

  • PDF

Seismic qualification using the updated finite element model of structures

  • Sinha, Jyoti K.;Rao, A. Rama;Sinha, R.K.
    • Structural Engineering and Mechanics
    • /
    • 제19권1호
    • /
    • pp.97-106
    • /
    • 2005
  • The standard practice is to seismically qualify the safety related equipment and structural components used in the nuclear power plants. Among several qualification approaches the qualification by the analysis using finite element (FE) method is the most common approach used in practice. However the predictions by the FE model for a structure is known to show significant deviations from the dynamic behaviour of 'as installed' structure in many cases. Considering such limitation, few researchers have advocated re-qualification of such structures after installation at site to enhance the confidence in qualification vis-$\grave{a}$-vis plant safety. For such an exercise the validation of FE model with experimental modal data is important. A validated FE model can be obtained by the Model Updating methods in conjugation with the in-situ experimental modal data. Such a model can then be used for qualification. Seismic analysis using the updated FE model and its advantage has been presented through an example of an in-core component - a perforated horizontal tube of a nuclear reactor.

Basic Principles of the Validation for Good Laboratory Practice Institutes

  • Cho, Kyu-Hyuk;Kim, Jin-Sung;Jeon, Man-Soo;Lee, Kyu-Hong;Chung, Moon-Koo;Song, Chang-Woo
    • Toxicological Research
    • /
    • 제25권1호
    • /
    • pp.1-8
    • /
    • 2009
  • Validation specifies and coordinates all relevant activities to ensure compliance with good laboratory practices (GLP) according to suitable international standards. This includes validation activities of past, present and future for the best possible actions to ensure the integrity of non-clinical laboratory data. Recently, validation has become increasingly important, not only in good manufacturing practice (GMP) institutions but also in GLP facilities. In accordance with the guideline for GLP regulations, all equipments used to generate, measure, or assess data should undergo validation to ensure that this equipment is of appropriate design and capacity and that it will consistently function as intended. Therefore, the implantation of validation processes is considered to be an essential step in a global institution. This review describes the procedures and documentations required for validation of GLP. It introduces basic elements such as the validation master plan, risk assessment, gap analysis, design qualification, installation qualification, operational qualification, performance qualification, calibration, traceability, and revalidation.

액체금속 피동냉각유동모사 실증설비의 개발 (Development of Liquid Metal Passive Cooling Flow Simulation System)

  • 류경하;김재형;이태현;이상혁;반병민
    • 대한기계학회논문집 C: 기술과 교육
    • /
    • 제3권4호
    • /
    • pp.257-264
    • /
    • 2015
  • 원자력 발전이 중요한 에너지 공급역할을 담당하기 위해서는 안전성을 확보하고, 사용 후 핵연료 문제를 해결하여야 한다. 이와 같은 문제를 해결하기 위한 방안으로 소듐이나 납비스무스 공융합금 등과 같은 액체금속을 냉각재로 이용하는 방안이 연구되고 있다. 본 논문에서는 액체금속 유동모사 실증 설비 개발을 위한 설계변수 검토, 설계 해석, 구조재의 선정 및 설비 개발 결과를 서술하였다. 설비의 개발은 열수력 해석코드의 해석을 통해 수행되었고 충분한 자연순환 유량을 갖는 설비제작 기술을 확보하였다.

원전 캐비넷 구조물의 동적보강효과에 관한 연구 (A study on Seismic Retrofitting of the NPP Cabinets)

  • 이계희;김재민;정연석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 봄 학술발표회 논문집
    • /
    • pp.374-381
    • /
    • 2003
  • In this study, the reduction schemes of ICRS(In-Cabinet Response Spectra), the main part of seismic safety qualification of old nuclear power plant(USI A-46 problem), are studied. To obtain accurate dynamic characteristics of cabinet structure, the cabinet structure modeled by frame model and its eigen analysis is performed. The three types of seismic retrofitting scenarios, such as 1) the installation of bracing, 2) installation of damper, 3) installation of tuned mass damper(TMD), are established and evaluated for the decreasing of ICRS. In the cases of 1) & 2), since, the retrofitted structures show larger ICRS than that of original structure, the careful considerations are need in the application of these methods. Though, the case of TMD show the best retrofitting result, the tuning between the real structure and analysis model is estimated the essential step of retrofitting.

  • PDF

신호시스템 시운전 시험 연구 (A Study on Test Working of Signalling System)

  • 정의진;황종규;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.157-163
    • /
    • 2000
  • Testing evaluation is a part of process for design, production, evaluation, operation and abolition, and is the process of certifying system performance. The main purpose of testing evaluation is to reduce the risk factor under the determining process. Testing process has the three step such as design qualification, integration and validation test in factory, system integration and commissioning test. Design Qualification is to verify errors on the design process. Integration and validation test in factory is for the H/W and S/W of an equipment and is to verify interface of subsystem, communication protocol and main functions. System integration and commissioning test is a functional test to adjust successful installation of equipment. According to the testing process, briefly consideration for test item, test method and test contents about signalling system is carried out.

  • PDF

원자력 발전소 계측제어시스템의 정보취득장치 설계 (Data Acquisition System Design of I&C System in Nuclear Power Plant)

  • 조정환;이동희
    • 조명전기설비학회논문지
    • /
    • 제17권2호
    • /
    • pp.102-108
    • /
    • 2003
  • 본 논문에서는 SDAS(Signal Data Acquisition System)를 설계하여 정밀도와 응답특성을 향상시킨 새로운 정보취득장치를 제안한다. 원자력 발전소에 적용되는 계측제어 시스템은 안전에 직접 또는 간접적으로 영향을 미치는 장치이므로 이들 기기는 안전등급의 분류에 따라 기기 검증의 절차에 의하여 현장 적용 이전에 주요 제어 설비가 설계명수 기간동안에 의도된 기능을 수행할 수 있음이 검증되어야 한다. 본 논문에서는 국제 기준 규격인 IEEE 규격과 Nuclear Regulatory Guide의 규격에 명시되어 있는 성능시험방법과 절차에 의한 기기검증에서 필수적인 장비인 정보취득장치를 제안하였고, 기존에 사용되고 있는 정보취득장치와 성능을 비교 분석하였다. 이론과 실험적인 연구가 수행되었고, 그 결과는 제안된 정보취득장치의 정밀도 성능이 개선되었음을 입증한다. 따라서 제안된 시스템은 고성능 계측제어시스템에 적용될 수 있다.

한국형 기동 헬기 엔진 (T700/701K) 개발 (Development of T700/701K Engine for KUH)

  • 김재환;안이기;이대성;성옥석;성인경
    • 한국추진공학회지
    • /
    • 제15권4호
    • /
    • pp.79-84
    • /
    • 2011
  • 본 논문은 한국형 기동헬기(수리온)에 탑재되는 T700/701K 터보 샤프트 엔진의 개발 현황을 기술한다. T700/701K 엔진은 군용 헬기엔진으로 널리 사용되고 있는 GE사의 T700엔진을 후방 구동형으로 최초 개조 개발한 엔진이다. 주요 개발 내용은 크게 엔진 장착 요구조건에 의한 후방 구동형 개조, 동력터빈 성능 향상 및 엔진 운전 신뢰성 향상을 위한 2채널 FADEC 시스템 적용 등이다. 2006년 6월 사업이 착수되어 개발 및 인증시험용 엔진의 초도 운전이 2008년에 성공적으로 수행되었으며 예비비행 정격시험 수행을 통해 2010년 3월에 첫 비행을 성공적으로 수행하였다. 현재 저주기 피로 시험과 일부 해석을 제외하고 군 인증을 위한 해석 및 시험이 완료 되었으며 2011년 상반기에 인증완료 예정이다.

방폭설비 성능유지 실태분석을 통한 관리방안 연구 (A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities)

  • 권용준;변정환
    • 한국안전학회지
    • /
    • 제35권2호
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

원자력 발전소 캐비닛구조물의 내진보강 (Seismic Retrofitting of Cabinet Structures in Nuclear Power Plant)

  • 이계희;김재민;김상윤
    • 한국지진공학회논문집
    • /
    • 제7권4호
    • /
    • pp.31-37
    • /
    • 2003
  • 본 논문에서는 오래된 원자력발전소의 내진검증과 관련한 USI A-46 문제의 해결에 사용될 수 있는 캐비닛의 내진보강방안에 대해 연구하였다. 캐비닛 구조물의 동적거동특성을 파악하기 위하여 3종류의 모델링을 수행하였고 그 결과를 비교하였다. 또한 ICRS(In Cabinet Reponse Spectrum)의 저감을 위하여 1) 보강프레임, 2)감쇠기 설치, 3) 동조질량감쇠기 등 세 가지 내진보강방안에 대하여 구조물의 응답을 산정하였다. 해석결과, 가새보강 및 감쇠기를 설치하는 보강방법에서는 보강전의 구조물보다 큰 ICRS가 얻어지는 경우가 발생해 보강시 많은 주의가 요구된다. 동조질량감쇠기의 사용은 좋은 제진효과를 보였으나 실구조물과 정확한 진동특성을 반영한 모델의 작성이 중요한 것으로 판단되었다.