• 제목/요약/키워드: Installation location

검색결과 609건 처리시간 0.029초

교류전기철도 보호특성 해석 및 고장점표정 시뮬레이션 (The Analysis of Protection -Characteristics and Fault-Locator Simulation on the Electrical Railway)

  • 창상훈;이장무
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.262-269
    • /
    • 1998
  • In case the fault occurs in AC power supply network, protective relaying system must selectively detect line-to-line/ground fault and immediately cut off the power flow into the fault location for guaranteeing the safety of people, electric vehicle and ground installation etc. It is the most important point in power system operation to minimize the fault duration by rapid trip scheme and accurate estimation of the fault location. In this paper, we analyze the load characteristics of each vehicle, perform the fault analysis of AC power supply network using AT current-ratio method. The result shows its usefulness.

  • PDF

자율주행차량과 일반차량의 인지 방식과 범위의 차이에 따른 교통안전시설 설치 및 운영 개선방안 연구 (Study on Improvement Plans for Installation and Operation of Traffic Safety Facilities according to Differences in Perception Methods and Range of Autonomous Vehicles and Human Vehicles)

  • 장혁준;고은정;한음;장기태
    • 한국ITS학회 논문지
    • /
    • 제22권1호
    • /
    • pp.311-326
    • /
    • 2023
  • 본 연구는 자율주행차량과 일반차량의 인지 방식과 범위의 차이를 비교하고 미시적 교통시뮬레이션을 활용한 교통안전시설의 설치 및 운영 개선방안을 제안하는 것을 목적으로 하였다. 연구에서는 기존 교통안전표지 설치·관리 업무편람을 검토하고 교통안전시설 중 안전표지를 차량의 행동 변화에 따라 분류하였다. 이후, 분류된 시설에 대해 가상환경에서 시뮬레이션 실험을 통해 안전표지의 설치 위치를 변경해가며 최적 설치지점을 추론하여 개선방안을 제시하였다. 본 연구는 일반 운전자의 시인성을 기준으로 설치된 교통안전시설이 자율주행차량과 일반차량이 혼재된 상황에서 도로 효율성과 안전성에 어떠한 영향을 주는지 확인하였다. 본 연구를 통해 도출한 교통안전시설의 인지에 대한 임곗값은 교통안전시설의 설치·관리에 관한 규칙의 개정 근거로 활용될 수 있다는 데 의의가 있다.

Thermal Performance Evaluation of Junction Thermal Bridge according to Installation Position of Window

  • Lee, Soo-Man;Kim, Dong-Yun;Ahn, Jung-Hyuk;Eom, Jae-Yong;Shin, U-Cheul
    • KIEAE Journal
    • /
    • 제17권3호
    • /
    • pp.15-21
    • /
    • 2017
  • Purpose: "Building energy design standard" is used to limit the thermal transmittance of building in Korea. However, it only covers the insulation standard for each appropriate elements of a building, not the thermal performance of Junction thermal bridge of windows and doors installed in wall. Therefore in this study, we have evaluated the thermal performance of Junction thermal bridge depending on installation method and position of windows and provide it as design data. Method: We analyzed heat transfer of 4-Track sliding window and tilt & turn triple glazed window that are placed in the first class category on window energy efficiency rating using Window 7.4 and Therm 7.4. Result : First, linear thermal transmittance of 4-Track sliding window differs by 2.2 times or more depending of installation method and location. It is higher than the linear thermal transmittance, 0.01W/mK, proposed by Passivhaus. Second, linear thermal transmittance of Tilt & turn triple glazed window differs by 7.7 times or more depending of installation method and location. The average linear thermal transmittance was less than 0.01W /mK when windows were installed on the internal wall insulation by the fixed hardware attachment method. Third, the thermal losses of a window caused by a junction thermal bridge are inversely proportional to the window area and converge gradually as the area increased.

가공 송전선의 사고 및 낙뢰 검출을 위한 새로운 하이브리드 센서 (A Novel Hybrid Fault Location Sensor Employable to the Power Transmission Systems)

  • 장용무;강무성;황률
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.583-584
    • /
    • 2005
  • In this work, a novel hybrid FL sensor consisting of two Rogowski coils has been designed for the installation on the ground wire of the transmission tower. The operation range of these coils is as follows: 30kA for the fault current comingfrom the ground fault or short-circuit and for the lightning current up to 150kA over 500kHz. Thus, two important functions could be provided: one is to detect the fault current and the other one is to find the fault location between towers or the location of induced lightning stroke. The on-site investigation at 800kV test yard has been under progress for its on-site application.

  • PDF

군 상징조형물 설치 특성에 관한 조사 연구 - 전라남도 군 상징조형물을 대상으로 - (A Study on the Installation Characteristics of Military Symbolic Sculptures - Targeting Symbolic Sculptures in Counties in Jeollanam-do -)

  • 김자연;김윤학
    • 한국농촌건축학회논문집
    • /
    • 제25권3호
    • /
    • pp.47-58
    • /
    • 2023
  • This study, as part of a study on the visual impact and evaluation of the symbolic sculptures currently installed in counties in Jeollanam-do on the formation of Landscapes by local governments, investigated and analyzed the installation characteristics of symbolic sculptures by local governments. As a result, many local governments have installed local specialties and landmarks as symbolic sculptures, and the installation location is often installed in open spaces and in the center of roundabouts. It was investigated that the use of color or the color of the material as it is was preferred. It was found that more symbolic sculptures installed on the roadside were installed in the center of the roundabout or along the side of the street than installation at the gateway. It is considered that it is more effective to recognize the symbolism of the area to the tourists through the installation of the symbolic sculpture at the entrance of the area, the center of the roundabout, or the side of the road rather than the gate, because the size of the symbol is bigger in order to recognize the symbolism of the area due to the width of the large road when installing the symbolic sculpture at the gateway, It is considered.

우수유출저감을 위한 간선저류지 위치선정에 관한 연구 (A study on the determination of location of the detention pond in trunk sewer for reducing runoff amounts)

  • 이성호;윤세의;이재준
    • 한국수자원학회논문집
    • /
    • 제50권4호
    • /
    • pp.223-232
    • /
    • 2017
  • 도시화 및 산업화로 인한 도시지역의 불투수율의 증가와 국지성 호우로 인하여 도시지역의 홍수에 대한 방어능력이 취약하게 되었다. 도시지역의 홍수피해 저감을 위하여 저류지와 침투시설을 포함한 각종 우수유출저감시설이 적용되고 있다. 그러나 국내 대도시의 경우 우수유출저감시설 설치를 위한 부지 확보가 어렵고 노후화된 관거 개선을 위한 예산확보도 어려운 실정이므로 도심지의 치수능력 향상과 예산을 절감시킬 수 있는 기존 우수관거를 연계한 저류시스템(이것을 간선저류지라 부르기로 한다)의 설계가 필요하다고 판단된다. 본 연구에서는 세 가지 형상(세장형, 중앙형, 집중형)의 가상유역을 대상유역으로 선정하여 기존 우수관거를 연계한 저류시스템인 간선저류지를 유역 내의 임의의 위치에 설치하였을 경우 간선저류지의 용량에 따른 우수유출저감효과를 분석하였다. 간선저류지는 6가지의 용량($1,000m^3$, $3,000m^3$, $5,000m^3$, $10,000m^3$, $20,000m^3$, $30,000m^3$)으로 설정하였고, 우수유출저감효과를 분석하기 위한 저류지의 설치위치는 전체 유역면적에 대한 저류지 상류부 면적의 비를 각각 20%, 40%, 60%, 80%로 변화시키면서 설치위치를 다양하게 적용하여 대상유역의 우수유출저감효과를 분석하였다. 또한 도출된 결과를 이용하여 간선저류지 설치위치에 따른 관계도 및 관계식을 제시하였다.

APPLICATION OF WIFI-BASED INDOOR LOCATION MONITORING SYSTEM FOR LABOR TRACKING IN CONSTRUCTION SITE - A CASE STUDY in Guangzhou MTR

  • Sunkyu Woo;Seongsu Jeong;Esmond Mok;Linyuan Xia;Muwook Pyeon;Joon Heo
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.869-875
    • /
    • 2009
  • Safety is a big issue in the construction sites. For safe and secure management, tracking locations of construction resources such as labors, materials, machineries, vehicles and so on is important. The materials, machineries and vehicles could be controlled by computer, whereas the movement of labors does not have fixed pattern. So, the location and movement of labors need to be monitored continuously for safety. In general, Global Positioning System(GPS) is an opt solution to obtain the location information in outside environments. But it cannot be used for indoor locations as it requires a clear Line-Of-Sight(LOS) to satellites Therefore, indoor location monitoring system could be a convenient alternative for environments such as tunnel and indoor building construction sites. This paper presents a case study to investigate feasibility of Wi-Fi based indoor location monitoring system in construction site. The system is developed by using fingerprint map of gathering Received Signal Strength Indication(RSSI) from each Access Point(AP). The signal information is gathered by Radio Frequency Identification (RFID) tags, which are attached on a helmet of labors to track their locations, and is sent to server computer. Experiments were conducted in a shield tunnel construction site at Guangzhou, China. This study consists of three phases as follows: First, we have a tracking test in entrance area of tunnel construction site. This experiment was performed to find the effective geometry of APs installation. The geometry of APs installation was changed for finding effective locations, and the experiment was performed using one and more tags. Second, APs were separated into two groups, and they were connected with LAN cable in tunnel construction site. The purpose of this experiment was to check the validity of group separating strategy. One group was installed around the entrance and the other one was installed inside the tunnel. Finally, we installed the system inner area of tunnel, boring machine area, and checked the performance with varying conditions (the presence of obstacles such as train, worker, and so on). Accuracy of this study was calculated from the data, which was collected at some known points. Experimental results showed that WiFi-based indoor location system has a level of accuracy of a few meters in tunnel construction site. From the results, it is inferred that the location tracking system can track the approximate location of labors in the construction site. It is able to alert the labors when they are closer to dangerous zones like poisonous region or cave-in..

  • PDF

아스팔트 콘크리트 포장 변형률계 매설 방법 개선에 관한 연구 (Improvement of Field Installation Method for Asphalt Concrete Pavement Strain Gauge)

  • 이재훈;김지원;김도형;이광호
    • 한국도로학회논문집
    • /
    • 제5권3호
    • /
    • pp.31-42
    • /
    • 2003
  • 국내의 포장 재료와 교통 및 기후조건이 반영되는 포장설계법 개발을 위한 연구가 진행중에 있으며, 이를 위해 실제 교통량 및 기후조건이 반영되고 이에 따른 포장의 거동을 모니터링 할 수 있는 대규모의 현장시험시설로 시험도로를 건설하였다. 시험도로 아스팔트 포장구간은 15개의 다양한 두께 및 재료를 가진 단면들로 구성되어 있다. 이러한 단면들을 평가하기 위해 포장체 내에 다양한 계측기들이 매설되어 있다. 계측기 매설에 있어서 핵심 요소는 매설 위치의 정확성과 장기적인 생존율 및 내구성이다. 외국의 시험사례를 보면, 이런 정확성과 내구성은 매설 방법에 크게 영향을 받는다. 이에 본 연구에서는 2000년도부터 3년여 동안 일반적인 계측기 매설 방법인 마운드, 블록아웃. 트렌치컷에 대해 시험시공을 수행하였으며 시험시공 결과를 분석하여 시험도로에 적용하였다. 위치의 정확성, 생존의 안전성, 시공성, 재료의 균질성 측면에서 시험시공 결과를 평가한 결과 블록아웃이 가장 효율적인 방법으로 나타났다. 그러나, 표층의 경우 블록아웃에 부적절한 층두께 등의 특성을 감안하여 마운드 방법을 사용하는 것으로 결정하였다. 아스팔트 기층과 중간층의 매설에는 블록아웃을, 표층의 매설에는 마운드를 사용하는 것으로 결정했다. 2003년 9월 3일부터 11월 18일까지 2달 여에 걸쳐 총 374개의 아스팔트 포장 변형률계를 시험도로에 매설하였다. 계측값 분석 결과, 마운드의 경우 6.3%, 블록아웃은 2.5%의 계측기가 매설 전후의 계측값 변화가 일반적인 계측기 사양 범위를 초과하는 것으로 나타났다. 생존율의 경우 매설후 손실된 계측기는 2개로 99.5%의 높은 생존율을 나타났다.

  • PDF

Localization of solar-hydrogen power plants in the province of Kerman, Iran

  • Mostafaeipour, Ali;Sedaghat, Ahmad;Qolipour, Mojtaba;Rezaei, Mostafa;Arabnia, Hamid R.;Saidi-Mehrabad, Mohammad;Shamshirband, Shahaboddin;Alavi, Omid
    • Advances in Energy Research
    • /
    • 제5권2호
    • /
    • pp.179-205
    • /
    • 2017
  • This research presents an in-depth analysis of location planning of the solar-hydrogen power plants for electricity production in different cities situated in Kerman province of Iran. Ten cities were analyzed in order to select the most suitable location for the construction of a solar-hydrogen power plant utilizing photovoltaic panels. Data envelopment analysis (DEA) methodology was applied to prioritize cities for installing the solar-hydrogen power plant so that one candidate location was selected for each city. Different criteria including population, distance to main road, flood risk, wind speed, sunshine hours, air temperature, humidity, horizontal solar irradiation, dust, and land costare used for the analysis. From the analysis, it is found that among the candidates' cities, the site of Lalezar is ranked as the first priority for the solar-hydrogen system development. A measure of validity is obtained when results of the DEA method are compared with the results of the technique for ordering preference by similarity to ideal solution (TOPSIS). Applying TOPSIS model, it was found that city of Lalezar ranked first, and Rafsanjan gained last priority for installing the solar-hydrogen power plants. Cities of Baft, Sirjan, Kerman, Shahrbabak, Kahnouj, Shahdad, Bam, and Jiroft ranked second to ninth, respectively. The validity of the DEA model is compared with the results of TOPSIS and it is demonstrated that the two methods produced similar results. The solar-hydrogen power plant is considered for installation in the city of Lalezar. It is demonstrated that installation of the proposed solar-hydrogen system in Lalezar can lead to yearly yield of 129 ton-H2 which covers 4.3% of total annual energy demands of the city.

용량제약이 있는 설비의 위치선정 및 수요자 할당문제에 대한 최적화 모형 및 해법 (Optimization Models and Algorithm for the Capacitated Facility Location-Allocation Problem)

  • 강성열;손진현
    • 디지털콘텐츠학회 논문지
    • /
    • 제3권2호
    • /
    • pp.221-233
    • /
    • 2002
  • 본 논문에서는 용량제약이 있는 설비의 위치선정 및 수요자 할당 문제(Capacitated Facility Location-Allocation Problem)에 대한 정수계획 모형과 해법을 제시하였다. 이 문제는 설비를 설치할 수 있는 후보지의 집합과 각 후보지별로 설치 가능한 설비의 용량 및 설치비용, 수요를 만족시켜야 할 수요자의 집합 및 각 수요자와 설치 후보지 사이의 운반비용이 주어져 있을 때, 설비들의 설치비용과 수요의 운반비용의 합을 최소화하는 설비의 설치 위치 및 대수 그리고 수요자와 설비간의 연결상태를 구성하는 문제이다. 본 논문에서는 이 문제에 대한 두 가지 정수계획모형을 제시하고, 이 모형에 대한 최적해를 구하기 위한 다면체적 절단평면을 이용한 분지-절단해법(Branch-and-cut algorithm)과 열생성기법을 이용한 분지-평가해법(Branch-and-Price algorithm)을 제시하였다. 제시된 모형과 해법은 물류시스템의 설계 및 정보통신시스템의 통신설비 위치선정 등에 활용될 수 있다.

  • PDF