Present and Future of Green Hospitals in Korea (종합병원의 친환경적 시설 실태와 향후 과제)

  • Seo, Youngjoon;Kang, Shinhee;Kim, Yeon-Hee;Lee, Yong-Gyun
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.16 no.1
    • /
    • pp.43-53
    • /
    • 2010
  • This study purports to investigate the status quo of the environmentally-friendly green healthcare in teaching hospitals through the questionnaire survey. Data were collected from a total of 46 hospitals. The survey results revealed that most teaching hospitals did not meet the global standard of environmentally-friendly green hospitals. Especially, such items as alternative energy system, water recycling, CO2 emission reduction, green building construction, installation of pond or spring were found to be significantly below global standard. Based upon the study results, various strategies for establishing green hospitals were discussed. For example, energy saving design, such as solar heating, natural wind cooling, automatic temperature controller, green material use, wall surrounded by ivy, were recommended. In conclusion, the strategy and evaluation tool developed in the study will provide a good guide for establishing environmentally-friendly green hospitals.

Development of an Electro-mechanical Driven Broaching Machine

  • Park, Hong-Seok;Park, In-Soo;Dang, Xuan-Phuong
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.1
    • /
    • pp.7-14
    • /
    • 2015
  • The machine tools builders are trying to improve the efficiency and performance of the machine tools. The electro-mechanical driven broaching machine has many advantages such as lower noisy operating, higher energy efficiency, and smaller space of installation. This paper presents the structural and mechanical development of an electro-mechanical driven broaching machine that is replaced for traditional hydraulic one. The servo motor, ball screw and roller linear guide are used instead of hydraulic cylinder and translation frictional sliding guides. The simulation method based on FEM was applied to analyze the stress, deformation of the machine for static analysis. The dynamic analysis was carried out for verifying and assessing the mechanical behavior of the developed broaching machine. This work helps broaching machine developer make a better product at the early design stage with lower cost and development time.

The Establishment of Evaluation Criteria for CD-ROM Encyclopedias (CD-ROM 백과사전의 평가기준 설정)

  • Park, Joon-Shik;Moon, Jung-Soon
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.34 no.1
    • /
    • pp.17-37
    • /
    • 2000
  • This study aims to provide a guide to the selection and purchase of a good CD-ROM encyclopedia by establishing evaluation criteria for CD-ROM encyclopedia. This study first divided evaluation criteria into the following rune categories: reviews available, print version, availability of trial disc, hardware requirements and ease of software installation, database contents, retrieval software, standalone/network version, standard/deluxe version, costs. Next, it suggested evaluation points and items in detail under each category.

  • PDF

Performance and Flow Characteristics of Axial Fan (축류팬의 성능 평가 및 주변 유동 특성)

  • 김재원;정윤영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.972-981
    • /
    • 2000
  • Comprehensive work is done for flows by an axial fan by experimental research. The present model fan is used for air handling device for out-door unit of an air conditioner in home appliance. PIV(Particle Image Velocimetry) system and wind tunnel are adopted for measurements of flows and performance evaluation, respectively. Major experimental conditions are the installation depth of a fan into a bellmouth of it. Optimal position of a fan in an inlet guide tube is observed by examination of fan-performance and flows in both upstream and downstream of the fan. Consequently, in the case of the fan inserted in half depth into the inlet tube, the efficiency of fan shows its maximum value and flow patterns is also streamlined.

  • PDF

Recent Trends in Domestic Landfill Liners (국내폐기물 매립장 치수재 현황조사 연구)

  • 정하익;홍성완
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1994.03a
    • /
    • pp.65-74
    • /
    • 1994
  • In this paper, various aspects of landfill liners such as guide of liner installation, type of bottom liners and vertical barriers, domestic companies producing and dealing liners, quality assurance and control of liners, are investigated. Although sanitary landfilling of domestic municipal wates has begun at the last decade, we still need to strengthen the regulation for designing and constructing the liner systems and to diversify the types of liners used in the landfills. Technologies of quality control for selecting and installing landfill liners should be improved as soon as possible. In order to develop the technologies and to slove th problems related to landfill liners, more efforts should be taken among the engineers and the agencies who are interested in maintraining safe subsurface environments.

  • PDF

Development of Cleaning Robot System for Live-line Suspension Insulator Strings in 345kV Power Lines and Its Application (345kV 송전선로 활선 현수애자련 청소로봇 시스템의 개발 및 적용)

  • Park, Joon-Young;Cho, Byung-Hak;Byun, Seung-Hyun;Lee, Jae-Kyung;Park, Doo-Yong
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1769-1770
    • /
    • 2007
  • To prevent an insulator failure, an automatic cleaning robot was developed for suspension insulator strings. The robot autonomously moves along the insulator string using the clamps installed on its two moving frames, and adopts a dry cleaning method using rotating brushes and a circular motion guide. In addition, a mechanized brush bristles and a voltage-balancing contactor are devised to increase cleaning efficiency and to prevent arc generation under live-line conditions, respectively. Moreover, a manual tool for its installation and removal is presented. We confirmed its effectiveness through experiments.

  • PDF

The Trend of suppression technology of harmonics for distribution system (고조파 유출 억제기술의 동향)

  • Koh Hee Seog;Lee Hyun Moo;Lee Chung Sik
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.330-332
    • /
    • 2004
  • Reliance on electric power has increased together with customer's demand for delightful and convenient linging. Recently, as appeared in the rapid growth of the technology of power electronics, the installation and apparatus using semiconductor applicotion is widly supplied and used from a household goods to industrial goods. However, these machine generate harmonics current and voltage for electric power system. The harmonics current is increased voltage distortion and generate a lot of interference in the electric power system. In this paper, the trend of the trend of suppression technology of harmonics outflow and the fundamental theory about the suppression of harmonics current in the distribution system are investigated and evaluated Therefore we look forward to supply electric power of good quality to satisfy the harmonics current guide line which is applied to household goods in the world.

  • PDF

Change in Exposure Concentration in the Cleaning Process after Installing a Local Exhaust System (디클로로메탄 사용 세척공정의 국소배기장치 설치 후 노출농도 변화)

  • Myung Hwa Cho;Seung gi Kim;Hyun Soo Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.280-283
    • /
    • 2023
  • Objectives: The purpose of this study was to examine the change in exposure concentration in the cleaning process after installing a local exhaust system. Methods: Dichloromethane measurement was conducted according to the KOSHA Guide (A-19-2019). Results: After the local exhaust device was installed, a total of three measurements were conducted, including temporary work environment measurements, and all of the measurements did not exceed the DCM exposure standard, but were more than 50% of the DCM Time Weighted Average((8-TWA) Conclusions: It is thought that the local ventilation system of a small business needs not only support for the initial installation cost, but also educational support for maintaining the performance of the local ventilation system and support for consumables (adsorbents, filters, etc.) that incur periodic costs.

Implant Supported Fixed Restoration for Maxillary Edentulism using CAD/CAM Guided Implant Surgery (NobelGuide$^{TM}$) and Immediate Loading (상악 완전 무치악 환자의 CAD/CAM 을 이용한 임플란트 식립(NobelGuide$^{TM}$) 및 즉시하중 후 고정성 보철수복 증례)

  • Huh, Yoon-Hyuk;Yi, Yang-Jin;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.423-439
    • /
    • 2012
  • This case report described a technique utilizing a computer-aided design (CAD)/computer-aided machining (CAM) - guided surgical implant placement and prefabricated temporary fixed prosthesis for an immediately loaded restoration. The advantages of CAD/CAM guided implant procedures are flapless, minimally invasive surgery and shorter surgery time. With this technique, less postoperative morbidity and delivery of prosthesis for immediate function would be possible. A patient with an edentulous maxilla received 8 implants in maxilla using CAD/CAM surgical templates. Prefabricated provisional maxillary implant supported fixed prosthesis were connected immediately after implant installation. Provisional prosthesis was evaluated for aesthetics, function during 6 months. Definitive implant supported fixed porcelain fused metal bridges were fabricated.

Numerical Analysis for Improvement of Windshield Defrost Performance of Electric Vehicle (전기자동차 전면유리 제상성능 개선을 위한 전산수치 해석)

  • Kim, Hyun-Il;Kim, Jae-Sung;Kim, Myung-Il;Lee, Jae Yeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.5
    • /
    • pp.477-484
    • /
    • 2019
  • As the residence time in the vehicle increases, the passenger desires a pleasant and stable riding environment in addition to the high driving performance of the vehicle. The windshield defrosting performance is one of the performance requirements that is essential for driver's safe driving. In order to improve the defrosting performance of the windshield of a vehicle, relevant elements such as the shape of the defrost nozzle should be appropriately designed. In this paper, CFD based numerical analysis is conducted to improve defrost performance of small electric vehicles. The defrost performance analysis was performed by changing the angle of the defrost nozzle and the guide vane that spray hot air to the windshield of the vehicle. Numerical simulation results show that the defrosting performance is best when the defrost nozzle angle is $70^{\circ}$ and the guide vane installation angle is $60^{\circ}$. Based on the analytical results, the defrosting experiment was performed by fabricating the defrost nozzle and the guide vane. As a result of the experiment, it is confirmed that the frost of windshield is removed by 80% within 20 minutes, and it is judged that the defrost performance satisfying the FVMSS 103 specification is secured.