• Title/Summary/Keyword: Installation guide

Search Result 147, Processing Time 0.025 seconds

An Analysis of the Trend on the Interior Lighting Design of High-rise Office Buildings in Korea (국내 초고층 오피스 건축물의 조명설계 경향 분석)

  • Jeong, Keun-Young;Hong, Seong-Kwan;Choi, An-Seop;Lee, Jeong-Ho
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.157-160
    • /
    • 2007
  • Recently, may high-rise buildings have been constructed, and will be constructed so that concerns about high-rise buildings have increased. We need to develop energy saving techniques immediately because the high-rise buildings consume a lot of energy. The most of effective energy saving method is the application of the efficient lighting designs and fixtures. The purpose of this study is to analyze the trend of lighting design, fixture and control system in Korea and it can be used the lighting application guide-line for the high-rise buildings.

  • PDF

Development and Performance Property Investigation of Lighting System using Plastic Optical Fiber (플라스틱 광섬유를 이용한 조명시스템 개발과 특성 분석)

  • Shin, Sang-Uk;Yi, Chin-Woo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.12
    • /
    • pp.25-32
    • /
    • 2010
  • Compared to general lighting method, the lighting system that uses optic fiber can provide only the visible light of good quality to subject by eliminating ultraviolet ray and infrared ray. Thanks to this merit, it is possible to prevent the hard phenomenon of subject caused by ultraviolet ray and infrared ray and to provide the agreeable light environment. This study developed indoors illumination system of high color rendering on the basis of plastic optic fiber with excellent optical property and processing to substitute halogen lamp which has been used for excellent color rendering in spite of low efficiency and short life. Producing pilot product of the designed illumination system and evaluating the property of electric and optical property, ultraviolet ray radiation quantity and temperature property, this study verified the excellence of suggested lighting system of plastic optic fiber.

Assesment of the Decrement in Tensile Strength of an Overhead Transmission Line's Conductor in Korean Power System

  • Bae, In-Su;Kim, Dong-Min;Kim, Jin-O
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.9
    • /
    • pp.61-69
    • /
    • 2006
  • The tensile strength of an overhead transmission line's conductor in response to an aging is being assessed in this paper. It is our view that, the decrement in the conductor's tensile strength is a key index that can be used to determine a conductor's end of life and a current limits. This paper describes a probabilistic method of assessing this index for main transmission lines which are responsible for the north bound power flow in the Seoul metropolitan area. Such an assessment can be a useful guide for economic system operation.

A Study on Improvement of Ramp Installation Standard for BF Certification (BF 인증을 위한 경사로 설치기준 개선에 대한 연구)

  • Shin, Dong Hong
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.26 no.2
    • /
    • pp.31-38
    • /
    • 2020
  • Purpose: The ramp is an important facility for the barrier free access and vertical circulation of users of various buildings, including users of walker, wheelchair users, stroller users, and baggage carriers. The installation standards for ramps in Korea have various problems during construction and BF certification. It is necessary to improve the criteria for ensuring practical mobility and safety. Method: Korean standard, International Standard(ISO 21542, 2011), German Standard(DIN 18040-1, 2010), Austrian Standard(OENORM B 1600, 2017), Swiss Standard(Norm SIA 500, 2009), Canadian Standard(Building Standards Guide, 2017), American Standard(ADA Standards, 2010) were investigated and analyzed. A comprehensive improvement of the ramp installation standards is proposed. Results: The ramp is a necessary facility for the barrier free access and vertical circulation of the disabled. It shall be installed with comprehensive consideration of the appropriate slope of the ramp, the distance of the continuous slope, the handle and upstand for pedestrian safety. In order to improve convenience, setting the proper slope and limiting the length of the slope are very important, and improvements are required to the levels presented by international and foreign standards. The unclear standards of Korean law and BF certification standards should be clearly improved so as not to be misinterpreted in construction and Barrier Free Certification. Implication: International and foreign standards should be reviewed to ensure practical mobility and safety. And comprehensive improvement measures should be presented through continuous research.

Lug Arrangement and Dynamic Analysis of Lifting Simulation for Underwater Installation of Structure in Asymmetric Position (비대칭 위치의 수중 구조물 설치를 위한 러그 위치 산정 및 리프팅 동역학 해석)

  • Jo, A-Ra;Park, Kwang-Phil;Lee, Hyun-Jin
    • Journal of the Society of Naval Architects of Korea
    • /
    • v.52 no.4
    • /
    • pp.283-289
    • /
    • 2015
  • RGT(Riser Guide Tube) is a part of mooring on the bottom of a turret system to be connected with a production riser, and DBSC(Diverless Bend Stiffener Connector) is a latching component between them. In this paper, appropriate lug arrangement is decided mathematically for the case that a DBSC is lifted and installed on a RGT under the water while FPSO is under construction. Considering asymmetric arrangement & position of RGT and initial lug position, additional lug positions are determined by using an optimization method. The modified installation scheme with new lug points is investigated with a lifting simulation system, SIMSON. The simulation result shows that the installation of DBSC on RGT under the given conditions is quite feasible; therefore the mathematical method is proven to be appropriate.

A Study on the Improvement of Proper Location for Subway Transit Station Sign Type - Focusing on the Cases of L Type - (지하철 환승역 안내표지 유형별 적정 위치 개선방안 연구 -L자형 지하철역 사례 중심으로-)

  • Kim, Hwang Bae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.37 no.5
    • /
    • pp.915-926
    • /
    • 2017
  • The subway is the transportation means most commonly used by the citizens of the metropolitan area along with the buses in the metropolitan area and major metropolitan municipalities. However, satisfaction with the signboards is low and the signboards need to be improved. In this study, we investigated the problem of guide signs of city hall and exchange area with L - shaped history structure for guide signs affecting route finding. As a result, it is necessary to confirm whether the moving distance is long and moving accurately to the desired destination due to the L - shaped historical structure in both the station and the alternate area. In both stations, the number of the guide signs, Problems such as installation position, height, other. In this study, the movement within the subway station is classified according to the space. The type of guide sign installation was defined, and the specific principles for guiding the movement route were proposed. This research is expected to be useful as an important basic data for the types and layout of subway stations.

A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities (방폭설비 성능유지 실태분석을 통한 관리방안 연구)

  • Kwon, Yong Jun;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.

An Evaluation of User's Facility and Suggestion for the Improvement on the Interior Design of Metropolitan Railroads Trains - Focus on the opening 14 metropolitan railroad lines in Seoul through checklist - (도시철도 차량 실내의 이용자 시설 평가와 개선방향 - 체크리스트를 통하여 수도권 노선에 운행 중인 14개 철도 차량을 대상으로 -)

  • Moon, Suh-Hyun;Kim, Gu-Seul;Shin, Kyung-Joo
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.5
    • /
    • pp.11-20
    • /
    • 2010
  • User-oriented Design is necessary in planning the interior design of Metropolitan Railroads trains, since this is a typical means of transportation in this modem society and all ages people with different body scale use this facility. However, there are little studies about facility panning and zoning of Metropolitan Railroads train considering users. Therefore, in this study, after completing the checklist based on the current legal standards of facility installation of South Korea and Japan, we examined user's facility and suggest several improvement of the opening 14 metropolitan railroad lines in Seoul. Then, we evaluated this facilities according to 41 standards; general facility(24 standards), safety facility(4 standards), guide facility(11 standards), other facility(4 standards). The result of this study may be summarized as follows. 1) General facility has to be designed to obtain lots of room for storage and this facility should be fixed up tightly with secure system. 2) Safety facility should be designed to minimize a difference of floor-level between threshold of train and ground. Also, using various color and material could help passengers to distinguish different space and facility. 3) Guide facility should be designed to guide passengers to the accurate direction with proper sign design in the pathway of Metropolitan railroad train. Also, more various color, which based on the research about physiological and psychological effect, should be used to guide people. 4) Other facility should equip more visual system using common good and informative contents. Through this study, we try to understand the current interior physical condition of Metropolitan Railroads trains. However, for future studies, it is expected to supplement evaluation standards considering aesthetic design, environmental improvement of indoor air quality and the satisfaction and demand of Metropolitan Railroads trains.

Fixed Prosthetic Restoration in an Edentulous Patient with NobelGuideTM System (양악 무치악 환자에서 NobelGuideTM 시스템을 이용한 고정성 임플란트 보철수복)

  • Shin, Hyoung-Joo;Kim, Dae-Gon;Cho, Lee-Ra;Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.3
    • /
    • pp.243-253
    • /
    • 2009
  • This report described a technique utilizing a computer-aided design (CAD) /computer-aided machining (CAM) - guided surgical implant placement and prefabricated fixed complete denture for an immediately loaded restoration. A patient with an edentulous maxilla and mandible received 6 implants in maxilla and 6 implants in the mandible using CAD/CAM surgical templates. Prefabricated provisional maxillary and mandibular implant supported fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics, function during 6 months. Definitive prostheses were fabricated.

Study on Cracking Causes and Patterns in Median Barrier and Guardrail Concrete in RC Bridge (콘크리트 교량 방호벽의 균열원인 및 패턴 분석에 대한 연구)

  • Choi, Se-Jin;Choi, Jung-Wook;Kwon, Seung-Jun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.18 no.5
    • /
    • pp.19-26
    • /
    • 2014
  • Concrete guide rail and median barrier are an attached RC member, however they are vulnerable to cracking due to slip form construction and large surface of member. In this study, causes and pattern of cracking are analyzed through assessment and NDT (Non-Destructive Technique) evaluation for concrete guide rail and median barrier on highway structure. For this work, analysis on drying shrinkage and hydration heat are performed considering installation period, and plastic shrinkage is also analyzed considering their environmental conditions. From the evaluation, plastic settlement around steel location, drying/ plastic shrinkage, and aggregate segregation are inferred to be the main causes of cracking in the structures. The crack causes and patterns are schematized and techniques of crack-control are suggested. Furthermore concrete guide rail/ median barrier in the bridge on the sea are vulnerable to cracking at early age so that special attentions should be paid at the stages of material selection and construction.