• Title/Summary/Keyword: Inspection standards

Search Result 432, Processing Time 0.021 seconds

The Development and The Usability Evaluation of the Game using the Physical Interface of the Mobile Phone (모바일폰의 물리적 인터페이스를 활용한 게임개발 및 사용성 평가)

  • Kim, Mi-Jin;Song, Seung-Keun;Kim, Ki-Il
    • Journal of Korea Game Society
    • /
    • v.9 no.2
    • /
    • pp.13-22
    • /
    • 2009
  • Recently, mobile games are developed as the various genre and form with the hardware performance improvement and communication network speed increase of the mobile phone. But it shows the limit of the game material to be developed, because the mobile game has to play by using only the keypad handing of the mobile phone. In this research, 'Flip On / Off interface' and 'Microphone interface' were developed in order to utilize the physical device of the mobile phone as the game interface. 'Flip On / Off interface' and 'Microphone interface' have the advantage that there is no need to purchase a device as an additional interface with utilizing the hardware of the mobile phone itself and the progressing of a game is smooth in comparison with the keypad method of the pre-existence mobile game because the interface waiting time for a call response is short. Moreover, by applying to a commercializing game, the developed interface tests, we confirmed an availability at the commercialization inspection standards on mobile phone without the heap memory deficiency phenomenon to be smooth of an operation. Furthermore, in the result of usability evaluation accessability, reliability, and aesthetics were rated as 'high'. The results of this research reveal that the interface environment of the mobile game limited to a keypad will be able to be made with diversification.

  • PDF

Evaluation of the HACCP System on Microbiological Hazard during Dressing Production (드레싱 제조업체의 HACCP 시스템 적용을 위한 미생물학적 위해도 평가)

  • Kwon, Sang-Chul
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.42 no.3
    • /
    • pp.457-463
    • /
    • 2013
  • The purpose of this study was to apply the Hazard Analysis Critical Control Point (HACCP) system to the production of dressing. The hazard analysis examined the main materials, industrial water, microbial evaluation, and airborne microorganisms of each working area, as well as the pathogenic microbial contamination risk. The survey was conducted at SJ Company in Jincheon (Chungchengbuk-do), Korea for 30 days from April 1, 2012 to April 30, 2012. The results showed that raw material microorganisms had a total plate count in industrial water below $3.00{\times}10$ CFU/mL in working room I, working room II, the packing room, washing water, and the inspection room for five times in each place. During dressing production (including heat treatment and mixing), general bacteria were detected at an average of $3{\times}10$ CFU/mL, but yeast, mold, and pathogenic bacteria were not detected. Airborne microbiological evaluation (for total plate count, yeast, and mold) found levels below the legal limit at each working area. While workers were positive for microbes in total plate counts, coliform and Staphylococcus aureus were not detected. In conclusion, standards for hygienic management should be established to prevent and decrease hazards, such as general bacteria and pathogenic microorganisms (for example, E. coli, B. cereus, Listeria spp, Salmonella spp, Staph. aureus, Clostridium perfringens, yeast, and mold), and to found critical limits for microorganisms with an HACCP system.

A Study on Mission Critical Factors for Software Test Enhancement in Information Technologies Development of Public Sector (Mission Critical 공공 정보화 구축 시험평가 개선 지표 연구)

  • Lee, Byung-hwa;Lim, Sung-ryel
    • Journal of Internet Computing and Services
    • /
    • v.16 no.6
    • /
    • pp.97-107
    • /
    • 2015
  • Up until recently, Korea has ranked the first place in UN e-Government Survey for three consecutive years. In keeping with such accomplishment, the size of budget execution has been consistently growing in accordance with Korea's Government 3.0 policy and vision, leading to increase in big-sized informatization projects in the business. Especially in mission critical public sector's infrastructure where it affects many people, growing demand for establishing high-quality information system with new technologies being brought to attention in order to meet the complex needs of citizens. National defense information system, being one of representative domains examples in the concerned area, established high military competency by applying breakthrough technology. Network-oriented national defense knowledge informatization was set as the vision in order to implement core roles in making efficient national defense management; and effort has been made to materialize the vision by making advancement in national defense's information system and its informatization implementation system. This research studies new quality index relevant to test and evaluation (T&E)of informatization business in national defense which is the representative example of mission critical public sector's infrastructure. We studied international standards and guidelines, analyzed actual T&E cases, and applied them to the inspection items that are currently in use, complying with the e-government law (Act No. 12346, Official Announcement Date 2014. 1.28., Enforcement Date 2014. 7.29.) As a result of productivity analysis, based on hypothesis in which suggested model was applied to T&E of the national defense informatization business, we confirmed the possibility of enhancement in the T&E productivity by assessing reliability, expertise, and safety as evaluation factors.

Usability Evaluation of Foot Pedal Switch in X-ray Radiography System (진단용 엑스선 촬영장치에서 발판 스위치의 유용성 평가)

  • Kwon, Hyeokjin;Jung, Hongmoon;Jung, Jaeeun;Jung, Kyunghwan;Won, Doyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.651-658
    • /
    • 2018
  • A foot pedal switch in the diagnosis x-ray radiography system has been researched to improve radiologic technologist works and patient satisfaction. The switch has been installed in the diagnosis x-ray radiography system used in domestic clinics. Quantitative evaluation has been conducted by measuring the exposure dose reproducibility test, tube voltage, mAs, and percentage average error. Qualitative evaluation has been conducted by analysis of the radiologic technologists questionnaire. In the quantitative evaluation for the use of the foot pedal switch, the coefficient of variation was less than 0.05 in the exposure dose reproducibility test. In the mAs test, percentage average error of ${\pm}20%$ was measured. There was no problem raised since it meets the all inspection standards of the diagnosis x-ray generator. In the qualitative evaluation, most of the opinions are that it has a clinical value for the foot pedal switch in the diagnosis x-ray radiography system. Therefore, developing the foot pedal switch for the diagnosis x-ray radiography system can improve effectively the rapidity and accuracy of the radiologic technologist work. In addition, it is effective in decreasing the x-ray exposure of patients and increasing satisfaction for the medical service due to reduction of retaking x-ray.

Testing and Analysis of Tube Voltage and Tube Current in The Radiation Generator for Mammography (유방촬영용 방사선발생장치의 관전압과 관전류 시험 분석)

  • Jung, Hong-Ryang;Hong, Dong-Hee;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Breast shooting performance management and quality control of the generator is applied to the amount of current IEC(International Electrotechnical Commission) 60601-2-45 tube voltage and tube current are based on standards that were proposed in the analysis of the test results were as follows. Tube voltage according to the value of the standard deviation by year of manufacture from 2001 to 2010 as a 42-3.15 showed the most significant, according to the year of manufacture by tube amperage value of the standard deviation to 6.38 in the pre-2000 showed the most significant, manufactured after 2011 the standard deviation of the devices, the PAE(Percent Average Error) was relatively low. This latest generation device was manufactured in the breast of the tube voltage and tube diagnosed shooting the correct amount of current to maintain the performance that can be seen. The results of this study as the basis for radiography diagnosed breast caused by using the device's performance and maintain quality control, so the current Food and Drug Administration "about the safety of diagnostic radiation generator rule" specified in the test cycle during three years of self-inspection radiation on a radiation generating device ensure safety and performance of the device using a coherent X-ray(constancy) by two ultimately able to keep the radiation dose to the public to reduce the expected effect is expected.

Evaluation of the Management of Sanitation in Food Service Establishments in Korea and Strategies for Future Improvement (국내 급식위생관리의 현황고찰 및 발전방안)

  • 김종규
    • Journal of Food Hygiene and Safety
    • /
    • v.15 no.3
    • /
    • pp.186-198
    • /
    • 2000
  • The quality of the management of sanitation in food service establishments (school lunch programs, hospital patient food services, and commercial catering food services) in Korea was reviewed and evaluated, and ten strategies fur future improvement were suggested. They were: (1) An increase of qualified manpower and improvement of the professional training of the staff; (2) Obtaining special facilities exclusively for food service; (3) Improvement of facilities especially the kitchens; (4) Improvement of policy fur procuring raw materials and being assured of their quality by designing some standards and specifications for the raw materials to be purchased; (5) Production and use accurate and reliable kitchen apparatus and instruments; (6) An increase of the laboratory apparatus and instruments for inspection and evaluation of the sanitary level of raw materials and food service environments; (7) Enforced improvement of personal hygiene of the staff; (8) Use of a variety of methods in sanitary education and training; (9) Actively inspect the quality of imported foods; (10) Strengthening the research and accumulation of background data regarding sanitation management. There is a long process from the production of food to eating. The cooking process is the ultimate end of preparation of food before eating. This process sometimes increases the occurrence of food-borne diseases if we mishandle the food, even we obtained safe food. The process can also remove health hazards and reduce the risk from the hazards if we handle the food well although we have unsafe foods. This means the cooking process is a major key to preventing food-borne diseases. The concepts of hazard analysis critical control point (HACCP) should be applied and practiced in food service establishments in Korea as soon as possible.

  • PDF

A Comparative Study on the Lens Dose According to the Change of Shielding Material Used in Brain Computed Tomography (Brain CT에서 차폐 재료 변화에 따른 수정체 선량 비교 연구)

  • Hwang, Incheol;Shin, Woonjae;Gang, Eunbo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.1
    • /
    • pp.31-37
    • /
    • 2015
  • The cases of radiographic inspection for medical diagnosis in Korea have been continuously increasing year after year, which pays particularly more attention to CT which occupies over the half of medical radiation exposure. To find an effective alternative for reducing radiation exposure, the researchers conducted comparative experiments using some shields made of bismuth, aluminum 6mm, and silicone 22mm. These shielding materials have been used to reduce the entrance surface dose (ESD) on lenses, maintaining the CT number, noise, and uniformity in brain CT scanning which forms the largest part in CT scanning these days. These experiments showed that the doses in the spiral scan parallel to IOML and the conventional scan in Bismuth were 26.41% and 17.52%, respectively; in Aluminum 18.24% and 9.39%; in Silicone 19.47% and 14.39% lower than compared with those in the cases without any shields. In the items of the CT number, noise, and uniformity, the bismuth shield satisfied exceedingly the standards of the phantom image test while aluminum and silicone were within. To keep the graphic quality and get good shielding effect, we recommend the silicone shield which can be manufactured and purchased with ease.

Evaluation of Out-door Fitness Safety in the Korea - TUV Standards Applied - (국내 야외 운동기구 안전성 평가에 관한 연구 - TUV 기준을 적용하여 -)

  • Kim, Yeong-Ha;Hwang, Sun-Ju;Park, Seung-Burm
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.41 no.5
    • /
    • pp.46-56
    • /
    • 2013
  • This research prepared safety standard for out-door fitness and this research's purpose is to evaluate and investigate safety condition for out-door fitness which was distributed in domestic residence by applying TUV standard which evaluate product's safety inspection. We choose twelve companies which have many sales' amount and investigated for ten out-door fitness which have high consumer preferences. As a result of that, the ratio of successful applicants for safety evaluation was 55.1%. The terms desired was evaluated highly in safety for out-door fitness's fixing condition. However, the terms desired was evaluated lowly in safety for movable condition. Fitness equipment which has high consumer preferences was compared lowly than other equipment in safety part. It was analyzed that there was no difference in safety evaluation according to manufacturing company. So, it is necessary to prepare safety standard by establishing law in order to prevent accident while they are using because we cannot think that fitness equipments which was distributed in domestic area have high safety. We think that preparing safety standard can influence on preventing accident and reinforcing out-door fitness manufacturing companies' competitive.

A Study on the Method of Magnetic Flux Leakage NDTfor Detecting Axial Cracks (축방향 미소결함 검출을 위한 자기누설 비파괴 검사 방법에 관한 연구)

  • Yun, Seung-Ho;Park, Gwan-Soo
    • Journal of the Korean Magnetics Society
    • /
    • v.21 no.1
    • /
    • pp.23-31
    • /
    • 2011
  • From among the NDT (nondestructive testing) methods, the MFL (magnetic flux leakage) method is specially suitable for testing pipelines because pipeline has high magnetic permeability. The system applied to MFL method is called the MFL PIG. The previous MFL PIG showed high performance in detecting the metal loss and corrosions. However, MFL PIG is highly unlikely to detect the cracks which occur by exterior-interior pressure difference in pipelines and the shape of crack is long and very narrow. In MFL PIG, the magnetic field is performed axially and there is no changes of cross-sectional area at cracks that the magnetic field passes through. Cracks occur frequently in the pipelines and the risk of the accident from the cracks is higher than that from the metal loss and corrosions. Therefore, the new PIG is needed to be researched and developed for detecting the cracks. The circumferential MFL (CMFL) PIG performs magnetic fields circumferentially and can maximize the magnetic flux leakage at the cracks. In this paper, CMFL PIG is designed and the distribution of the magnetic fields is analyzed by using 3 dimensional nonlinear finite element method (FEM). In CMFL PIG, cracks, standards of NACE, are detectable. To estimate the shape of crack, the leakage of magnetic fields for many kinds of cracks is analyzed and the method is developed by signal processing.

Statistical analysis of hazen-williams C and influencing factors in multi-regional water supply system (광역상수도 유속계수와 영향인자에 관한 통계적 분석)

  • Kim, Bumjun;Kim, Gilho;Kim, Hung soo
    • Journal of Korea Water Resources Association
    • /
    • v.49 no.5
    • /
    • pp.399-410
    • /
    • 2016
  • In case of the application of Hazen-Williams C for design, operation or maintenance of water supply system, field situations always should be reflected on the factors. In this study, the relationships between C factors and influencing factors are analyzed using statistical techniques with 174 measured C factor data collected in periodic inspection for safety diagnosis in multi-regional water supply systems. To analyze their relationships, cross analysis, one-way ANOVA, correlation analysis were conducted. Analysis results showed that C factors had high correlations with both of elapsed year and pipe diameter and were relatively highly affected by coating material among influencing factors with the categorical type. On the other hand, elapsed year, pipe diameter and water type were meaningful influencing factors according to the results of multiple regression analysis. The Cluster analysis revealed that C factors had a tendency of being fundamentally classified on the basis of the elapsed year of about 20 years and the pipe diameter of 1500mm. Although C factors were generally greatly affected by elapsed year, size of pipe diameter relatively had an large influence on values of them in case of large diameter pipes. Lastly, It can be suggested that C factor estimation formulas using multiple regression analysis and clustering analysis in this study, can be applied as decision standards of C factor in multi-regional water supply systems.