• Title/Summary/Keyword: Inspection Equipment

Search Result 652, Processing Time 0.024 seconds

Development of the Defect Inspection Equipment for Mobile TFT-LCD Modules (Mobile용 TFT-LCD 화면 검사장비 개발)

  • Koo, Young-Mo;Hwang, Man-Soo
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.19 no.2
    • /
    • pp.259-264
    • /
    • 2009
  • High level quality control is required for mobile TFT-LCD modules which are frequently used for fine observation. However, quantitative quality control is difficult. Defect inspection using naked eyes makes irregular inspection results. This paper developed desk type defect inspection equipment for mobile TFT-LCD modules using the same inspection criterion with that of naked eyes. From experiments using this equipments, possibilities of standardization in defect inspection equipment for mobile TFT-LCD modules are presented.

The Radiation Safety Management in the Animal Hospital Using Inspection Standard of Diagnosis Radiation System (진단용 방사선발생장치의 검사기준을 적용한 동물병원의 방사선 안전관리)

  • Kim, Sang-Woo;Rhim, Jea-Dong;Han, Dong-Kyoon;Seoung, Youl-Hun
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.4
    • /
    • pp.73-80
    • /
    • 2010
  • The purpose of this study was to investigate the actual conditions of radiation safety supervision in animal clinics using inspection standard of X-ray generator for diagnosis. The surveys for inspection standard system, equipment condition, and safety supervision were carried out in 18 animal clinics randomly. The inspection standard included reproducibility of dose exposure, kVp, mAs, collimator accuracy test, collimator luminance test, X-ray view box luminance test, grounding system equipment test and external leakage current test. The surveys of equipment condition and safety supervision used one-on-one interview with 5 points measurement. As a result, 44.44% of reproducibility of dose exposure was proper, 81.25% of kVp test was good, and 100% of mAs test was appropriate. Also, 66.66% of collimator accuracy test was proper, 61.11% of collimator luminance test was good, 53.13% of X-ray view box luminance test was suitable. In addition, only 5.55% of grounding system equipment and ground resistance was proper, 63.64% of external leakage current test was appropriate in grounding system equipment test. The 100mA electric capacity of X-ray generator for diagnosis was popular with 44.44%, and its 55.56% was purchased used equipment. Monthly average of less than 50 times (61.11%) was top frequency in use, and no animal clinic had a thermo-luminescence dosimeter(TLD). The 16 animal clinics with radiation safety zone and 2 without radiation safety zone were appeared.

Comparision in Emission Inspection System of a Gasoline Vehicle in Service (운행 휘발유 자동차의 배출가스검사 시스템 비교)

  • Oh, Sangyeob;Park, Wondeok
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • In the most of a nation, the safety and emission gas inspection system of a vehicle in service have been conducted with the most compatible inspection system according to its real environmental situation. Especially, the state of vehicle emission gas is measured by advanced emission gas inspection equipment. It has the problem that the decrease effect of an environmental pollution matter is not calculated by weight percent measurement type equipment. Therefore, in this study, the correlations for the results of emission gas measurement are analyzed by comparing a weight percent measurement type (IDLE+ASM2525 mode) and an advanced mass measurement type (IM240 mode). As the result, the selectivity of an emission gas by IM240 mode is higher than that by IDLE+ASM2525 mode. In the future, therefore, the introduction of IM240 mode and a mass measurement type equipment are necessary. Also, we need to prepare a vehicle emission gas inspection system for introducing IM240 mode.

Determining factor about the regulation compliance of inspection on harmful machine, instrument and equipment (위험기계.기구 및 설비 검사의 규제 순응 결정 요인)

  • Yi, Kwan-Hyung;Oh, Ji-Young;Rhee, Kyung-Yong
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.77-84
    • /
    • 2007
  • This study was planned to investigate what the main factor of the regulation compliance of inspection on harmful machine, instrument and equipment by industrial safety and health act is. This study subject was composed of three groups as employers, employees of manufacturing and using the harmful machine and safety inspectors. Manufacturing workplace were 236 places, using workplace were 201 places and the safety inspectors were 100 people. The study subject was sampled by stratified random sampling considering the type of harmful Machine. Data for analysis is collected from each sample using interview with structured questionnaires. Compliance is measured by 2, 3, and 4 point scale composed by 8 sub items such as general perception, understanding, clearness, necessity, relevancy, implementation, penalty, and general compliance of the regulation. The level of 8 items of employer's compliance are not differentiated among three groups. The determining factors for inspection observance of the workplace using the harmful Machine were understanding, penalty and cognized compliance. The determining factors for inspection observance of the workplace manufacturing the harmful Machine were understanding and object conformity. These results show that the strategy to adapt the regulated group to inspection regulation will be the elevation of understanding for regulation first of all.

Ball Grid Array Solder Void Inspection Using Mask R-CNN

  • Kim, Seung Cheol;Jeon, Ho Jeong;Hong, Sang Jeen
    • Journal of the Semiconductor & Display Technology
    • /
    • v.20 no.2
    • /
    • pp.126-130
    • /
    • 2021
  • The ball grid array is one of the packaging methods that used in high density printed circuit board. Solder void defects caused by voids in the solder ball during the BGA process do not directly affect the reliability of the product, but it may accelerate the aging of the device on the PCB layer or interface surface depending on its size or location. Void inspection is important because it is related in yields with products. The most important process in the optical inspection of solder void is the segmentation process of solder and void. However, there are several segmentation algorithms for the vision inspection, it is impossible to inspect all of images ideally. When X-Ray images with poor contrast and high level of noise become difficult to perform image processing for vision inspection in terms of software programming. This paper suggests the solution to deal with the suggested problem by means of using Mask R-CNN instead of digital image processing algorithm. Mask R-CNN model can be trained with images pre-processed to increase contrast or alleviate noises. With this process, it provides more efficient system about complex object segmentation than conventional system.

A Study on Clean Agent Fire Extinguishing Ability Using Nitrogen and Novec Mixtures Gas (질소와 노벡 혼합가스를 이용한 청정소화약제의 소화성능에 관한 연구)

  • Lim, Woo-Sub;Jung, Jong-Jin;Nam, Dong-gun;SaKong, Seong-Ho;Kim, Jong-Won;Choi, Kenu-Joo
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.6
    • /
    • pp.76-83
    • /
    • 2008
  • In the course of increasing in human and material damage caused by fire, it is an important research field to develop clean extinguishing agent which does no harm to global environment as well as has a good extinguishing efficiency. This research is a basic step to develop a new clean extinguishing agent. In order to get a satisfactory result, we tested fire extinguishing ability using nitrogen and Novec mixtures gas which are inert gas and new clean extinguishing agent. We used Cup Burner Test made by international standard ISO-14520 regulations of gaseous extinguishing agent ability test, and the fuels used in the test are n-heptane, methanol, ethanol, iso-propanol and 1-butanol. The experimental results of flame extinguishing concentration are n-heptane 6.54%, methanol 8.47%, ethanol 6.98%, isopropanol 6.10% and butanol 6.54% by pure Novec agent. So the finding is that a new clean agent, Novec has an efficient extinguishing ability in a state of gas. Also, in a test as to mixtures gas of nitrogen and Novec, it has a good result for minimum oxygen concentration is under 16%.

Implementation for Real-Time of MIL-STD-1553B Communication in Inspection Equipment Based on Windows with RTiK and DPC Control (RTiK과 DPC 제어를 통한 윈도우즈 기반의 검사장비에서 MIL-STD-1553B 통신의 실시간 구현)

  • Kim, Jong-Jin;Lee, Sang-Gil;Lee, Cheol-Hoon
    • Journal of Korea Multimedia Society
    • /
    • v.24 no.2
    • /
    • pp.199-207
    • /
    • 2021
  • It is very important to support real-time on the inspection equipment based on Windows. In particular, in the system using MIL-STD-1553B communication, which is widely used in military weapon systems, real-time is required for inspection equipment that uses mostly platforms based on Windows such as Industrial PCs. However, in order to use a complete real-time operating system such as VxWorks, the purchase cost is expensive and the implementation is complicated on the system, so it is not suitable for inspection equipment that requires simple functions to just check go or no-go. Therefore, in this paper, a Real-Time implanted Kernel(RTiK) in the Windows kernel is implanted in order to improve these defects, and real-time performance is implemented for periodically MIL-STD-1553B communication by Deferred Procedure Call(DPC) of Windows. Also, it was verified that the period of up to 2ms was guaranteed with a RDTSC into the EDX:EAX registers for measuring the periodicity.

Structure and Fatigue Analyses of the Inspection Equipment Frame of a Semiconductor Test Handler Picker (반도체 테스트 핸들러 픽커 검사장비 프레임에 대한 구조 및 피로해석)

  • Kim, Young-Choon;Kim, Young-Jin;Kook, Jeong-Han;Cho, Jae-Ung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.10
    • /
    • pp.5906-5911
    • /
    • 2014
  • Currently, there are many processes of package assembly and inspections of real fields that examine whether a manufactured semiconductor can be operated regularly and can endure low humidity or high temperatures. As the inspection equipment of a semiconductor test handler picker has been used at the inspection process, these inspection equipment frames were modelled in 3D and these models were analyzed using 3 kinds of fatigue loadings. As the analysis result, maximum deformation occurred at the midparts of the frames at cases 1 and 2. Among the cases of nonuniform fatigue loads, the 'SAE bracket history' with the severest change in load became the most unstable but the 'Sample history' became the most stable. Fatigue analysis result can be used effectively with the design of an inspecting equipment frame of a semiconductor test handler picker to examine the prevention and durability against damage.

A Study on the Reformation of Certified Fire Fighting Specialists - Focused on Fire Protection System Managers - (소방전문자격사제도의 개선에 관한 연구 - 소방시설관리사를 중심으로 -)

  • Oh, Hyeong-Geun
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.6 no.4 s.23
    • /
    • pp.21-28
    • /
    • 2006
  • This research analyzed the operational status of fire protection system managers who execute self inspection of the fire equipment in the specific fire protection facilities and presented the improvement scheme. Being made up inquiry for job environment, institutional environment, and operational environment for the subject of fire protection system managers who execute self inspection to complement the fire equipment inspection by city public fire protection service, the issues of the operational status of the institution of fire protection system managers were positively understood. The research result showed the conflict among building owner, fire equipment inspector, and fire protection system manager was existed due to the legal and institutional inertia to the self inspection, so it is judged that mutual complementary and cooperative relation should be established.

A Specialized Reader for High Speed UHF RFID Tag Inlay Inspection Equipment (고속 UHF RFID 태그 검사 장비를 위한 전용 리더)

  • Bae, Sung Woo;Park, Jun-Seok;Seong, Yeong Rak;Oh, Ha-Ryoung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.1
    • /
    • pp.63-69
    • /
    • 2014
  • RFIDs have not become widespread as expected partly due to the cost, size, read range, and reliability problems of tags. The success rate of reading must be improved in order for RFIDs to be widely adopted. Quality control of tags is crucial to meet this requirement. In this study, we designed and implemented a high-performance reader used in inspection equipment that conducts prior inspection of tags. To improve performance of the developed reader, the baseband modem and command processor (CP) were designed using H/W logic and implemented with FPGA. The inspection of small pitch inlays was made possible through the antenna shielding device and H/W command processor function. This equipment enables accurate evaluation of performance and identification of tags satisfying a given read range. By contributing to sort out defective tags, the results can ultimately lead to more stable RFID services.