• Title/Summary/Keyword: Inside humidity

Search Result 382, Processing Time 0.026 seconds

A Study on the Environment and Inhabitant of Gosu Cave in Sindanyang (신단양 고수동굴의 환경과 서식생물에 관한 연구)

  • Kim, Byoung-Woo;Park, Sang-Young
    • Journal of the Speleological Society of Korea
    • /
    • no.67
    • /
    • pp.11-20
    • /
    • 2005
  • The envirronment of Gosu cave and distribution of inhabitant were surveyed every month from 2002, April to 2003, march. in Gosu Cave, average temperature in summer was $16^{circ}C$ and in winter $14^{circ}C$. Average humidity in summer was $85\%$ and in winter $90\%$. At the entranceof cave in the site 1, trogloxenes:4 species were observed. Troglophiles: Diestrammena japanica was a large population. inside of cave in the site 2 and in the middle Part of the site 3, troglobites:4 species, troglophiles:2 species, trogoxenes: Rhinoiophus ferrumeqinum korai, skleroprotopus laticoxalis longus were observed. Galloisiana sp. were observed on the ground of the Sindong in the site 4, Pseudocrangonyx asiaticus were obserued in the water of yongsu valley. Troglobites have to be preserve as cave animals living in the darkness for a long time.

Effect of the factor developing the Heat of Hydration on Durability Design in the Subway Concrete Structure (수화열 발생인자가 지하철 콘크리트 구조물의 내구설계에 미치는 영향)

  • Lim Young-Su;Kim Eun Kyum;Sung Ki Han
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.1131-1137
    • /
    • 2004
  • With the recent continuous expansion of subways, newly created subways tend to have lower locations and wider sections. Furthermore. since box structures and evacuating tunnels are classified into a category of mass-concrete. the thermal-stress, emitted from the inside. causes cracks to structures from the inception of constructing. In this paper, thermal-stress analysis and durability evaluation of box structure were carried out to investigate relationship between durability and parameter causing the heat of hydration. Through the examination, this paper tries to find out satisfactory solutions to regulated thermal crack and ensure the required duration period. The results of this paper showed that to control thermal crack and guarantee the required duration period it was more effective to use low-heat-portland cement and moderateheat-portland cement. As cement volume due to reduction of water-cement ratio increased, the possibility of thermal cracks occurrence increased but results of durability evaluation was different depending on evaluation method. The results showed that the appropriate water-cement ratio to control the heat of hydration and satisfy the required durability was $45\∼55\%$. And it was showed that during placement of concrete blocks ambient temperature affect the heat of hydration. thermal crack and long-term durability largely and when concrete was placed at low temperature to control thermal crack. it need to try to guarantee the required duration period. Henceforth, by studying not only internal and external conditions, such as the relative humidity and the unit weight. but also methods, to evaluate durability, in accordance with domestic situations, more reasonable design of durability should be achieved.

  • PDF

Android based Reagent Cabinet Safety Management System (안드로이드 기반 시약장 안전 관리 시스템)

  • Choi, Hyungwook;Min, Gyeongbae;Lee, Jongwon;Jung, Hoekyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.579-580
    • /
    • 2017
  • Recently, as safety accidents by reagents increase in laboratories, systems are being developed to safely manage reagents. The existing system monitoring and manages the reagent through the web page, but the internal environment change of the reagent cabinet is considered or the remote monitoring and control function is insufficient. In order to solve this problem, this paper predicts the deterioration of the reagent loaded in the reagent cabinet. And we propose a system that can monitoring and control remotely. It predicts the deterioration of the reagent through the temperature attached to the inside of the reagent cabinet, the value measured by the humidity sensor and the validity period of the reagent, and sends a alert message to the manager. The manager monitoring and controls the reagent cabinet through the application. By predicting the deterioration of the reagents and remotely managing the reagents cabinet it is thought that safety accidents can be reduced.

  • PDF

Physiological Response of Panax Ginseng to Tcmpcrature II. Leaf physiology, soil temperature, air temperature, growth of pathogene (인삼의 온도에 대한 생리반응 II. 엽의 생리, 지온, 기온, 병환의 생육)

  • Park, Hoon
    • Journal of Ginseng Research
    • /
    • v.4 no.1
    • /
    • pp.104-120
    • /
    • 1980
  • The effects of temperature on transpiration, chlorophyll content, frequency and aperture of stomata, and leaf temperature of Panax ginseng were reviewed. Temperature changes of soil and air under spade roof were also reviewed. Growth responses of responses of ginseng plant at various temperature were assessed in relation to suseptibillity of ginseng plants. Reasonable management of ginseng fields was suggested based on the response of ginseng to various temperatures. Stomata frequency may be increased under high temperature during leaf$.$growing stage. Stomata aperture increased by high temperature but the increase of both frequency and aperture appears not enough for transpiration to overcome high temperature encountered during summer in most fields. Serial high temperature disorder, i.e high leaf temperature, chlorophyll loss, inhibition of photosynthesis, increased respiration and wilting might be alleviated by high humidity and abundant water supply to leaf. High air temperature which limits light transmission rate inside the shade roof, induces high soil temperature(optimum soil temperature 16∼18$^{\circ}C$) and both(especially the latter) are the principal factors to increase alternaria blight, anthracnose, early leaf fall, root rot and high missing rate of plant resulting in poor yield. High temperature disorder was lessen by abundant soil water(optimum 17∼21%) and could be decreased by lowering the content of availability of phosphorus and nitrogen in soil consequently resulting in less activity of microorganisms. Repeated plowing of fields during preparation seems to be effective for sterilization of pathogenic microoganisms by high soil temperature only on surface of soils. Low temperature damage appeared at thowing of soils and emergence stage of ginseng but reports were limited. Most limiting factor of yield appeared as physiological disorder and high pathogen activity due to high temperature during summer(about three months).

  • PDF

The Comparison on the Compression Measurement Value of Medical Compression Stockings (수입 의료용 압박스타킹의 압력 측정치 비교)

  • Do, Wol-Hee;Kim, Nam-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.37 no.8
    • /
    • pp.1060-1074
    • /
    • 2013
  • This study measured and analyzed pressure at each measurement part of imported compression stockings sold in Korea to provide basic information to establish a pressure standard and grade ranking. This study used 40 medical compression stockings imported from 6 countries. Pressure measurements were taken at 11 points: front side and back side of ankle, end-point of the gastrocnemius muscle, front, inner side, back, and outer side of calf, back side of below knew girth, inner side, and outer side of mid-thigh girth, and inner side of thigh girth. AMI 3037-10 and AMI 3037-2 were used for measurements taken inside an environmental chamber at a temperature of $21^{\circ}C$ and a relative humidity (RH) of 65%. For the measurements, 11 air pack sensors were attached to a wooden model leg (Hohenstein) and three measurements were taken at each measurement point in three minutes. The average of these measurements was used for analysis. The findings of this study were as follows. As for the front side of the ankle, of the 40 products, 14 products (6 USA, 2 Swiss, 3 Italian, and 2 Taiwanese) were within the pressure range indicated on the product label; however, no German products fell within the pressure range. A total of 8 products (5 USA, 1 Swiss, 1 Italian, and 1 German) were gradient compression type; however, no Japanese or Taiwanese product were of this type. The majority of products had the highest pressure at the end-point of the gastrocnemius muscle. Only 3 products, 1 USA (Jobst Opaque 30-40mmHg), 1 Swiss (Sigvaris Cotton 34-46mmHg) and 1 Italian (Jobstocking 25-32mmHg), had measurements that met the indicated standard pressure, were a gradient compression type, and met the overall standard for compression stockings.

Reagent Cabinet Danger Priority Based Reagent Cabinet Safety Management System (시약장 위험 우선순위 기반 시약장 안전 관리 시스템)

  • Choi, Hyungwook;Lee, Jongwon;Kim, Changsu;Ryu, Seunghan;Jung, Hoekyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.10a
    • /
    • pp.727-728
    • /
    • 2017
  • Recently, various accidents caused by reagents in laboratories have demanded a safety management system suitable for the danger situation. The existing system operated the equipment according to the temperature and humidity change inside the reagent cabinet, but the operation of the device corresponding to the danger situation and the countermeasures against many dangerous situations are insufficient. In order to solve this problem, this paper proposes a reagent cabinet safety management system based on the reagent cabinet danger priority in happen of accidents caused by reagents under management. The danger priority is type of reagents and selected by the danger situation that can be caused by the reagents. If a danger situation occurs, operate the device according to the selected danger priority and the type of danger situation. It is considered that the reagent cabinet can be safely managed by checking the danger situation in the reagent cabinet and operating the device according to the danger priority.

  • PDF

Fracture Toughness Measurement of the Semiconductor Encapsulant EMC and It's Application to Package (반도체 봉지수지의 파괴 인성치 측정 및 패키지 적용)

  • 김경섭;신영의;장의구
    • Electrical & Electronic Materials
    • /
    • v.10 no.6
    • /
    • pp.519-527
    • /
    • 1997
  • The micro crack was occurred where the stress concentrated by the thermal stress which was induced during the cooling period after molding process or by the various reliability tests. In order to estimate the possibility of development from inside micro crack to outside fracture, the fracture toughness of EMC should be measured under the various applicable condition. But study was conducted very rarely for the above area. In order to provide a was to decide the fracture resistance of EMC (Epoxy Molding Compound) of plastic package which is produced by using transfer molding method, measuring fracture is studied. The specimens were made with various EMC material. The diverse combination of test conditions, such as different temperature, temperature /humidity conditions, different filler shapes, and post cure treatment, were tried to examine the effects of environmental condition on the fracture toughness. This study proposed a way which could improve the reliability of LOC(Lead On Chip) type package by comparing the measured $J_{IC}$ of EMC and the calculated J-integral value from FEM(Finite Element Method). The measured $K_{IC}$ value of EMC above glass transition temperature dropped sharply as the temperature increased. The $K_{IC}$ was observed to be higher before the post cure treatment than after the post cure treatment. The change of $J_{IC}$ was significant by time change. J-integral was calculated to have maximum value the angle of the direction of fracture at the lead tip was 0 degree in SOJ package and -30 degree in TSOP package. The results FEM simulation were well agreed with the results of measurement within 5% tolerance. The package crack was proved to be affected more by the structure than by the composing material of package. The structure and the composing material are the variables to reduce the package crack.ack.

  • PDF

Experiments on granular flow in a hexagonal silo: a design that minimizes dynamic stresses

  • Hernandez-Cordero, Juan;Zenit, R.;Geffroy, E.;Mena, B.;Huilgol, R.R.
    • Korea-Australia Rheology Journal
    • /
    • v.12 no.1
    • /
    • pp.55-67
    • /
    • 2000
  • In this paper, an experimental study of the rheological behavior of granular flow in a new type of storage silo is presented. The main characteristic of the new design is a hexagonal shape chosen with the objective of minimizing the stresses applied to the stored grains, and to reduce grain damage during the filling and emptying processes. Measurements of stress distribution and flow patterns are shown for a variety of granular materials. Because of the design of the silo, the granular material adopts its natural rest angle at all times eliminating collisional stresses and impacts between grains. A homogeneous, low friction flow is naturally achieved which provides a controlled stress distribution throughout the silo during filling and emptying. Secondary dynamic stresses, which are responsible for wall failure in conventional silos of the vertical type, are completely eliminated. A comparison between the two geometries is presented with data obtained for these silos and a number of granular materials. The discharge pattern inhibits powder formation in the silo and the filling system virtually eliminates unwanted material packing. Finally, notwithstanding the rheological advantages of this new design, the hexagonal cells that constitute the silo have many other advantages, such as the possible use of solar energy to control the humidity inside them. The cell type design allows for versatile storage capabilities and the elevation above the ground provides unlimited transportation facilities during emptying.

  • PDF

Control of Powdery Mildew on Cucumber by Using Oleic Acid in the Greenhouse (올레산을 이용한 오이의 흰가루병 방제)

  • Lee, Moon-Haeng;Kim, Young-Shik
    • Korean Journal of Organic Agriculture
    • /
    • v.22 no.4
    • /
    • pp.695-703
    • /
    • 2014
  • We experimented with the effect of oleic acid and its appropriate concentration to prevent powdery mildew eco-friendly in a cucumber greenhouse cultivation. 'Baekbongdadaki' (Nongwoo Bio. co. Korea) was treated in the plastic greenhouse at Sangmyung University. We treated four levels of concentration of oleic acid, which were 0, 2000, 4000, 6000, and 8000 ppm. There were investigated diseased severity, diseased leaf area, control value, and pesticide injury. The degree of control values by oleic acid treatments was investigated at 3 days after treatment. The recurrence of powdery mildew was checked for 55 days. The day and night temperature in the greenhouse were controlled to 23 and $15^{\circ}C$ respectively. The humidity inside the greenhouse was not controlled to prevent outbreak of the disease. From the experimental results, oleic acid was very efficient to control powdery mildew. 2000 ppm of oleic acid was shown to be the most control efficiency without any pesticide injury. The recommended method to treat it was to spray three times every 3 weeks.

Design and Implementation of Remote Monitoring System for Underground Low Voltage Handhole Using Zigbee Communication (지그비 통신을 이용한 지중저압접속함 원격 모니터링 시스템 설계 및 구현)

  • Weon, La-Kyoung
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.18 no.3
    • /
    • pp.58-67
    • /
    • 2019
  • The low-voltage connection box used as a low-voltage transmission line of KEPCO is intended to branch or connect to an underground line. In comparison with the utility considering the aesthetics of the distance, and safety measures are needed. In this paper, temperature and humidity, $CO_2$, water level, acceleration, and vibration sensor are installed inside the underground low voltage handhole, and the sensor data is transmitted to the ground using the Zigbee module. Antenna (Bolted Antenna) for communication with the ground was proposed and the data reception through it was confirmed. In the LF mode and the HEX mode, the transmitted data was confirmed to be a perfect reception success rate. In the case of the bolted antenna, the difference between the ground state and the underwater state was observed as a result of the experiment in the environmental environment. However, It was judged that reception sensitivity was sufficient for communication. The received data could be confirmed through PC based GUI.