Design and Performance Evaluation of MIN for Nonuniform Traffic (비균등 트래픽을 위한 MIN의 설계 및 성능 평가)

  • Choe, Chang-Hun;Kim, Seong-Cheon
    • Journal of the Institute of Electronics Engineers of Korea CI
    • /
    • v.37 no.6
    • /
    • pp.1-9
    • /
    • 2000
  • This paper presents a Cluster Oriented Multistage Interconnection Network called COMR. COMR can be constructed suitable for the parallel application with localized communication by providing the shortcut path inside the processor-memory cluster which has frequent data communication. We evaluate the performance of COMR with respect to probability of acceptance, bandwidth, cost-effectiveness and average distance under varying degrees of localized communication. According to the result of analysis for performance evaluation, COMR shows higher performance than the regular MINs of the same network size in the highly localized communication. In the worst case, the diameter of an N$\times$N COMR is only n+1 which has only one stage more as compared the MIN with the same network size. Therefore COMR can be used as an attractive interconnection network for parallel applications with not only the localized communication distribution but also the uniform distribution in shared-memory multiprocessor system.

  • PDF

A Study on Performance Evaluation for Oil Mist Removal using a High-speed Centrifugal Cyclone (고속원심분리 사이클론을 이용한 오일 미스트 제거 성능 연구)

  • Kim, SooYeon;Kim, Jin-Seon;Sung, Jin-Ho;Han, Bangwoo;Kim, Yong-Jin;Kim, Hak-Joon
    • Particle and aerosol research
    • /
    • v.15 no.4
    • /
    • pp.139-148
    • /
    • 2019
  • This study was performed for the application of a high-speed centrifugal cyclone to shale gas mining process. This device uses the centrifugal force to control particles similar to typical cyclones, and the disk located inside the cyclone is forced to rotate using a motor. The pressure difference occurred during the rotating of disk. Hence, inflow rate was generated without a blower fan. In addition, flow rate increased with elevating rpm of motor. The installing the disk in multiple stages on the inner rotor increased the instantaneous disk outlet flow. Hence, the control efficiency of oil particle increased from 1.05% to 31.2%. By modifying the structure of the disk so that the air flow to the opposite direction of the cyclone, the control efficiency of oil particles increased to 81.5%. By increasing the capacity of the motor and the size of the disk, the flow rate was increased to 2.5 ㎥/min because the rpm of motor and pressure difference increased. As rpm of motor increased, the cut-off diameter (dpc) became smaller. Unlike the Lapple's equation, dpc was inversely proportional to the effective number of rotations (Ne). The control efficiency was maintained even if the concentration of oil particles increased, for this reason, the higher the oil concentration, the more particles were accumulated and controlled.

Acoustic Effect of an Orifice on Suppression of Pressure Oscillation in a Fluid Feeding Line (유체 공급 배관내 압력진동 감쇠에 미치는 오리피스의 음향학적 효과)

  • Son, Chae-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.34 no.4
    • /
    • pp.11-16
    • /
    • 2006
  • Effects of an orifice on suppression of pressure oscillation in a fluid feeding line are investigated numerically through the installation of an orifice inside the feeding line. Based on linear acoustic theory, acoustic-damping effect of an orifice is emphasized in this study. When an orifice is installed at the node of pressure oscillation corresponding to the anti-node of velocity oscillation, damping capacity is maximized. On the other hand, the orifice installed at the anti-node of pressure oscillation has little damping capacity. As the blockage ratio and thickness of an orifice increase in the feeding line, damping factor increases. The feeding line with smaller diameter has more damping capacity, but damping factor increases more appreciably with blockage ratio in the feeding line with larger diameter.

Review of SQUID Sensors for Measuring Magnetocardiography (심자도 측정을 위한 SQUID 센서 기술의 개발 현황)

  • Lee, Y.H.;Kim, J.M.;Yu, K.K.;Kim, K.;Kwon, H.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

Effect of Piston Cavity Geometry on Formation and Behavior of Fuel Mxture in a DI Gasoline Engine (직분식 가솔린엔진에서 피스톤 형상이 연료 혼합기의 형성과 거동에 미치는 영향 .)

  • Kim Dongwook;Kang Jeongjung;Choi Gyungmin;Kim Duckjool
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.13 no.5
    • /
    • pp.82-89
    • /
    • 2005
  • This study was performed to investigate the behavior and spatial distribution of fuel mixtures with different wall angle and diameter of piston cavity in a DI gasoline engine. The spatial distribution of fuel mixtures after impingement of the spray against a piston cavity is one of the most important. factors for the stratification of fuel mixture. Thus, it is informative to understand in detail the behavior and spatial distribution of fuel mixtures after impingement in the cavity. Two dimensional spray fluorescence images of liquid and vapor phase were acquired to analyze the behavior and distribution of fuel mixtures inside cylinder by exciplex fluorescence method. The exciplex system of fluorobenzene/DEMA in non-fluorescing base fuel of hexane was employed. Cavity wall angle was defined as an exterior angle of piston cavity. Wall angles of the piston cavity were set to 30, 60 and 90 degrees, respectively. The spray impinges on the cavity and diffuses along the cavity wall by its momentum. In the case of 30 degrees, the rolling-up moved from the impinging location to the round and fuel-rich mixture distributed at periphery of cylinder. In the case of 60 and 90 degrees, the rolling-up recircurated in the cavity and fuel mixtures concentrated at center region. High concentrated fuel vapor phase was observed in the cavity with 90 degrees. From. present study, it was found that the desirable cavity wall angle with cavity diameter for stratification in a Dl gasoline engine was demonstrated.

An Experimental Study on Principal Factors for Non-destructive Test of Detecting Steel bars (비파괴 철근탐사의 주요 영향인자에 관한 실험적 연구)

  • Oh, Kwang Chin;Kim, Jong Ho;Rhee, Jong Woo;Lee, Yun Hyang
    • Journal of Korean Society of societal Security
    • /
    • v.3 no.1
    • /
    • pp.25-32
    • /
    • 2010
  • Detecting rebars in side the concrete structures is one of the important steps in assessing condition of the structure. In order to determine the detection capability of locating rebars inside the concrete, two types of equipments, which use radar system and electromagnetic system each, were tested. Four concrete specimens which have the dimensions of $1,000mm(length){\times}300mm(width)$ with different thickness and diameter of steel bars were applied. A series of testing was achieved after drying in air for 90 days, immersed in water for 3, 24, 48 hour and 28 day. From the experimental outcome, it is shown that error is increased as the diameter of rebar enlarge in case of electromagnetic method. In case of radar method, the detection of embedded rebars in deep is good in the view of reliability. As moisture content increase from 3.6% to 5.5%, the relative permittivity of concrete test specimens show tendency to increase, too. Therefore, it is shown that moisture content is one of the major contributing factors to determine the relative permittivity. And the relative permittivity regression equation is suggested.

  • PDF

Development of Liquid Density Measurement Sensor Using the Natural Frequency of a Pipe (파이프의 고유진동수를 이용한 액체밀도측정 센서개발)

  • Chang, Kyung-Ho;Lee, Yong-Jae;Kim, Kwang-Pyo;Ahn, Byung-Duk
    • Journal of Sensor Science and Technology
    • /
    • v.4 no.3
    • /
    • pp.9-14
    • /
    • 1995
  • For the development of liquid density measuring sensor using the natural frequency of a pipe, its principle and construction method were described. The stainless steel pipe, which has length of 32 cm, inside diameter of 2.3 cm and outside diameter of 2.5 cm, was used for the sensor. The exciting coil and the photo sensor were used to excite and to pick-up it, and the feedback circuit was designed to continue its vibrating. The natural frequency was consistent with the result of the spectrum analysis. It had a linearity of 0.0027 % and a sensitivity of 0.032 % in liquid density range from $0.8\;g/cm^{3}$ to $1.4\;g/cm^{3}$ and its frequency variation ratio was 0.024 $%/^{\circ}C$ in temperature range from $10^{\circ}C$ to $35^{\circ}C$.

  • PDF

Hydrodynamic Design of Thrust Ring Pump for Large Hydro Turbine Generator Units

  • Lai, Xide;Zhang, Xiang;Chen, Xiaoming;Yang, Shifu
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • Thrust-ring-pump is a kind of extreme-low specific speed centrifugal pump with special structure as numerous restrictions from thrust bearing and operation conditions of hydro-generator units. Because the oil circulatory and cooling system with thrust-ring-pump has a lot of advantages in maintenance and compactness in structure, it has widely been used in large and medium-sized hydro-generator units. Since the diameter and the speed of the thrust ring is limited by the generator set, the matching relationship between the flow passage inside the thrust ring (equivalent to impeller) and oil bath (equivalent to volute) has great influence on hydrodynamic performance of thrust-ring-pump. On another hand, the head and flow rate are varying with the operation conditions of hydro-generator units and the oil circulatory and cooling system. As so far, the empirical calculation method is employed during the actual engineering design, in order to guarantee the operating performance of the oil circulatory and cooling system with thrust-ring-pump at different conditions, a collaborative hydrodynamic design and optimization is purposed in this paper. Firstly, the head and flow rate at different conditions are decided by 1D flow numerical simulation of the oil circulatory and cooling system. Secondly, the flow passages of thrust-ring-pump are empirically designed under the restrictions of diameter and the speed of the thrust ring according to the head and flow rate from the simulation. Thirdly, the flow passage geometry matching optimization between thrust ring and oil bath is implemented by means of 3D flow simulation and performance prediction. Then, the pumps and the oil circulatory and cooling system are collaborative hydrodynamic optimized with predicted head-flow rate curve and the efficiency-flow rate curve of thrust-ring-pump. The presented methodology has been adopted by DFEM in design process of thrust-ring-pump and it shown can effectively improve the performance of whole system.

Design and Preliminary Performance Test for 5kWt Dish Solar Collector ($5kW_t$급 접시형 태양열 집열기의 설계 및 예비 성능실험)

  • Seo, Joo-Hyun;Ma, Dae-Sung;Kim, Yong;Seo, Tae-Beom;Han, Gui-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.27 no.4
    • /
    • pp.113-120
    • /
    • 2007
  • The 5kWt dish solar collector is designed and the preliminary performance test for this is carried out. The diameter of the parabolic dish is 3.2 m, and its focal length is 2 m. It consists of 10 small reflectors which have their own curvatures, and the effective reflecting area is $5.9\;m^2$, and the rim angle of the dish is $43.85^{\circ}$. The reflectivity of reflectors is 0.95, and the thermal capacity of the system is about 5 kW thermal. The aperture diameter of the cylindrical-shape receiver which is made of stainless steel is 100 mm, and the height is 210 mm. A quartz window is installed at the receiver aperture to minimize the convective heat loss and prevent air leakage. In order to increase the heat transfer area, porous materials (nickel-alloy) are inserted into the receiver. Air flows into the upper part of the receiver which is the opposite side of the aperture. After the air flows through the inside of the receiver, that goes out of the receiver through 3 exits which are located near the aperture. The volumetric flow rates of air are varied from 600 to 1200 L/min. The results show that the system efficiency and receiver efficiency increase as the volume flow rate increases.

Heat Transfer and Pressure Drop Characteristics of Supercritical $CO_2$ in a Helically Coiled Tube (초임계 $CO_2$의 헬리컬 코일관 내 열선단과 압력강하 특성)

  • Yu, Tae-Guen;Kim, Dae-Hui;Son, Chang-Hyo;Oh, Hoo-Kyu
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.353-358
    • /
    • 2005
  • The heat transfer and pressure drop of supercritical $CO_2$ cooled in a helically coiled tube was investigated experimentally. The experiments were conducted without oil in the refrigerant loop. The experimental apparatus of the refrigerant loop consist of receiver, a variable speed pump, a mass flowmeter, a pre-heater, a gas cooler(test section) and an isothermal tank. The test section is a helically coiled tube in tube counter flow heat exchanger with $CO_2$ flowed inside the inner tube and coolant( water) flowed along the outside annular passage, It was made of it copper tube with the inner diameter of 4.55[mm]. the outer diameter of 6.35 [mm] and length of 10000 [mm]. The refrigerant mass fluxes were $200^{\sim}600$ [kg/m2s] and the inlet pressure of gas cooler varied from 7.5 [MPa] to 10.0 [MPa]. The main results are summarized as follows : The heat transfer coefficient of supercritical $CO_2$ increases, as the cooling pressure of gas cooler decreases. And the heat transfer coefficient increases with the increase of the refrigerant mass flux. The pressure drop decreases in increase of the gas cooler pressure and increases with increase the refrigerant mass flux.

  • PDF