• Title/Summary/Keyword: Inside diameter

Search Result 738, Processing Time 0.028 seconds

Distribution of Vascular Canal at Lateral Wall of Maxillary Sinus in Korean Population Using Computed Tomography (컴퓨터단층촬영을 이용한 한국인의 상악동 측벽의 혈행 분포)

  • Song, Chi Bum;Kim, Chul Hwan
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.34 no.6
    • /
    • pp.432-439
    • /
    • 2012
  • Purpose: The aim of this study was to investigate the blood supply to the maxillary sinus in Koreans using computed tomography of the lateral wall of the sinus, and to analyze the data according to demographic data, and to compare our results with previously published research. Methods: One hundred and three patients (males 51, females 52) who visited the dental clinic were evaluated. We investigated the canals with cone-beam computed tomography, and measured the diameter and length from the bony notch of the vascular canal at the lateral wall of the sinus to each of the reference planes. Results: Most types of vascular canal were type I & II (total 72.2%) which were driving through inside the sinus wall. Type IV, V were frequently investigated in 1st premolar and 2nd molar. Mean height; from anterior nasal spine-posterior nasal spine plane to vascular canal was 5.56 mm in 1st premolar, 2.11 mm in 2nd premolar, 0.98 mm in 1st molar, 4.32 mm in 2nd molar; from the basal layer of the sinus was 4.93 mm in 1st premolar, 5.00 mm in 2nd premolar, 6.05 mm in 1st molar, 7.91 mm in 2nd molar; and from alveolar crest, 20.80 mm in 1st premolar, 16.57 mm in 2nd premolar, 14.01 mm in 1st molar, 16.17 mm in 2nd molar. The mean height of the vascular canal of each reference plane showed no significant difference between sex, site (left or right) and age. The mean diameters of the canals were 1.76 mm in male, and 1.50 mm in female. Diameter decreased with age, and tooth site (from 1st premolar to 2nd molar). Conclusion: These results show that the mean diameter of the vascular canal of the maxillary sinus varies according to age, sex, and tooth site, but that the mean height of canal had no significant difference based on these three factors.

Finite Element Analysis of the Artery and PTFE End-To-Side Anastomosis with 45${\circ}$ Anastomotic angle (45${\circ}$ 문합각을 가진 동맥과 PTFE 단측 문합의 유한요소해석)

  • Han, Geun-Jo;Kim, Hyeong-Tae;An, Seong-Chan;Sin, Jeong-Uk;Kim, Yeong-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.3
    • /
    • pp.253-259
    • /
    • 1997
  • Von Mises stress and compliance distribution was evaluated using a finite element analysis on the anastomosis of an artery with length of 20mm(z direction, along the horizental artery), inner diameter of 4mm, thickness fo 0.5mm and a PTFE graft with length of 5.7mm, inner diameter of 2mm, thickness of 0.2mm when anastomotic angle was $45^{\circ}$ and inner pressure of 1330 dyne/mm2 was applied inside the 2 conduits. From the analysis results were obtained as follows. (1) Artery diameter increased in both horizontal x(along the length of artery) and vertical y(perpendicular to the length of artery)directions and the magnitude of that in x direction was bigger than that in y direction. (2) The compliance was maximum on the anastomosis, especially on that with acute angle. The reduction of compliance was observed from the anastomosis area to the either right or left end. (3) The equivalent stress was maximum on top in the y direction and minimum on the nodes apart $110^{\circ}$ in circumferential direction from the top. (4) The equivalent stress was maximum in t도 vicinity of anastomosis with acute angle along the longitudinal direction of the artery. This trend was also observed along the PTFE graft.

  • PDF

Study on Development of the Bi-directional High Pressure Pile Load Test(BDH PLT) and Its Application (양방향 고유압 말뚝재하시험(BDH PLT)의 개발 및 적용성에 관한 연구)

  • Lee, Chung-Sook;Lee, Min-Hee;Kim, Sang-Il;Choi, Yong-Kyu
    • Journal of the Korean Geotechnical Society
    • /
    • v.23 no.6
    • /
    • pp.23-36
    • /
    • 2007
  • To overcome the limits of the static pile load test for large diameter drilled shafts, bi-directional low pressure pile load test (BDL PLT) has been used but this test method containes some problems that has not been solved basically. That is, BDL PLT has some problems: difficulty in jack (or cell) arrangement for large test capacity, void remain inside jack (or cell) due to the unrecovery of piston after test etc. In this study, bi-directional double-acting high pressure pile load test (BDH PLT W/DOJ) was developed and confirmed for a in-situ large diameter drilled shaft. At present, test specification of bi-directional pile load test (BDPLT) is being made, and severed main issues (such as, test kinds, test capacity, necessity of use of double-acting and attention of application to service pile) will be contained at the specification.

Concentric Structure and Radial Joint System within Basic Lava Flow at the seashore of Aewol, Jeju Island, South Korea (제주도 애월읍 해안의 염기성 용암류에 발달한 동심원 구조와 방사상 절리)

  • Ahn, Kun Sang
    • Journal of the Korean earth science society
    • /
    • v.42 no.2
    • /
    • pp.185-194
    • /
    • 2021
  • A lava dome and sheet lava flow can be observed at the seashore of Aewol, Jeju island. The cylindrical lobes are characterized by a concentric structure consisting of a massive core and radial joints. Columnar joints with different thickness between the upper and lower parts are developed in the sheet lava flow around the rock salt field in Goeomri. The upper part of the columnar joints is uneven in shape, and has a diameter of 120-150 cm. The lower part of the columnar joints is hexagonal and pentagonal in shape, and has a diameter of about 60 cm. The cylindrical lobes can be divided into two groups based on size and shape. One is a megalobe, with a semicircular outline and a maximum diameter of 30 m. The other is a circular lobe with a diameter of less than 10 m. The columns in the radial joints have hexagonal and pentagonal cross sections and gradually increasing diameter, outward from the core, to a size of 80-120 cm at the rim. The concentric structure observed in the cylindrical lavas is attributable to a combination of four factors. The first is a circular crack caused by the decrease of the temperature and density difference between the inside and outside of the cylindrical lava flow. The second is a concentric chisel mark of the radial joints, which formed at the same time as the radial joints. The third is a flow band, which is a trace left in a round passage when lava flows through. The fourth is a vesicular band formed in a cave by gas bubbles escaping from the lava flow.

Numerical analysis study on the concentration change at hydrogen gas release in semi-closed space (수치해석을 통한 반밀폐공간 내 수소가스 누출 시 농도변화에 관한 연구)

  • Baek, Doo-San;Kim, Hyo-Gyu;Park, Jin-Yuk;Yoo, Yong-Ho
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.23 no.1
    • /
    • pp.25-36
    • /
    • 2021
  • Hydrogen in hydrogen-electric vehicles has a wide range of combustion and explosion ranges, and is a combustible gas with a very fast flame propagation speed, so it has the risk of leakage, diffusion, ignition, and explosion. The fuel tank has a Thermally active Pressure Relief Device (TPRD) to reduce the risk of explosion and other explosions, and in the event of an accident, hydrogen inside the tank is released outside before an explosion or fire occurs. However, if an accident occurs in a semi-closed space such as an underground parking lot, the flow of air flow is smaller than the open space, which can cause the concentration of hydrogen gas emitted from the TPRD to accumulate above the explosion limit. Therefore, in this study, the leakage rate and concentration of hydrogen over time were analyzed according to the diameter of the nozzle of the TPRD. The diameter of the nozzle was considered to be 1 mm, 2.5 mm and 5 mm, and ccording to the diameter of the nozzle, the concentration of hydrogen in the underground parking lot increases in a faster time with the diameter of the nozzle, and the maximum value is also analyzed to be larger with the diameter of the nozzle. In underground parking lots where air currents are stagnant, hydrogen concentrations above LFL (Lowe Flammability Limit) were analyzed to be distributed around the nozzle, and it was analyzed that they did not exceed UFL (Upper Flammability Limit).

Effects of Dimple Depth and Reynolds Number on the Flow and Heat Transfer in a Dimpled Channel (딤플이 설치된 채널에서 레이놀즈 수 및 딤플 깊이에 따른 유동 및 열전달 특성)

  • Ahn, Joon;Lee, Young-Ok;Lee, Joon-Sik
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3253-3258
    • /
    • 2007
  • A large eddy simulation (LES) has been conducted for the flow and heat transfer in a dimpled channel. Two dimple depths of 0.2 and 0.3 times of the dimple print diameter (= D) have been compared at the bulk Reynolds number of 20,000. Three Reynolds numbers of 5,000, 10,000 and 20,000 have been studied, while the dimple depth is kept as 0.2 D. With the deeper dimple, the flow reattachment occurs father downstream inside the dimple, so that the heat transfer is not as effectively enhanced as the case with shallow ones. At the low Reynolds number of 5,000, the Nusselt number ratio is as high as those for the higher Reynolds number, although the value of heat transfer coefficient decreases because of the weak shear layer vortices.

  • PDF

Energy Storage Characteristics In Fixed Beds (Charging, Storing, Discharging)

  • Hassanein, Soubhi A.;Choi, Sang-Min
    • 한국연소학회:학술대회논문집
    • /
    • 2004.11a
    • /
    • pp.17-23
    • /
    • 2004
  • In the present work, the numerical model was refined to predict the thermal analysis of energy storage in a fixed beds during (charging ,storing, discharging) mode. The governing energy equations of both fluid and the solid particles along with their initial and boundary conditions are derived using a two-phase, one dimensional model. The refined model is carried out by taking into account change of (air density , air specific heat) with air temperature and also by taking into considerations heat losses from bed to surrounding. Finite difference method was used to obtain solution of two governing energy equations of both fluid and solid particles through a computer program especially constructed for this purpose. The temperature field for the air and the solid are obtained, also efficiency of energy stored inside the bed is computed. Finally using refined model the effect of air flow rate per unit area Ga (0.2, 0.3, and 0.4 kg/$m^2$-s), and inlet air temperature (200, 250, 300 $^{\circ}C$) on energy storage characteristics was studied in three mode ( charging ,storing, discharging). The rock particles of diameter 1 em is used as bed material in this research.

  • PDF

Characterization of Gas Distribution Effect in Inductively Coupled Plasma System (유도결합 플라즈마 시스템의 수치 모델링에서 가스 분배 특성 해석)

  • Joo, Junghoon
    • Journal of the Korean institute of surface engineering
    • /
    • v.46 no.3
    • /
    • pp.133-138
    • /
    • 2013
  • We have developed a 2D axi-symmetric numerical model for an inductively coupled plasma system in order to analyze gas mixing effect through a narrow gap shower head. For frictional flow, holes of 0.5 mm diameter and 2 mm length are approximately modeled in 2D. Gas velocity distribution 10 mm below the shower head showed 2 times difference between the center and the edge at 10 mTorr. At 10 mm above the wafer, it was increased to 6 times difference due to the pumping duct effect. The model with a 5 mm height buffer region of a shower head showed reasonable behavior of Ar discharge. The density of Ar metastable showed additional peak inside the buffer region around the edge holes.

Development of Directional Digital Hearing Aid Performance Testing System (지향성 디지털 보청기의 성능 검사 장치 개발)

  • Jarng, Soon-Suck;Kwon, You-Jung;Lee, Je-Hyeong
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.411-414
    • /
    • 2005
  • The most recent trend on digital hearing aid is to increase the ratio of signal to noise by directivity or to develop noise reduction algorithm inside DSP IC chip. This paper designed, fabricated and tested a digital hearing aid directivity testing device in which a micro-mouse-like the stepping motor with a speaker rotates around an examinant. Both ears of the examinant were fixed with ITE hearing aids in order to response to receiving sound. The diameter of the directivity testing device was 2 [m] and the micro-mouse was precisely controlled by PICBASIC micro processor.

  • PDF

Design of a large bore superconducting solenoid (대구경 초전도 솔레노이드 디자인)

  • 장현식;박수현;오상준;심성엽;김형찬;김영순;방소희;이명호;이형철
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.310-311
    • /
    • 2002
  • We designed a large bore superconducting solenoid as a source of magnetic field inside liquid-nitrogen-jacketed liquid helium dewar. The diameter of the sample space in the dewar is about 10.0 cm. Considering the space for thermal insulation between liquid helium and the sample tube, the solenoid bobbin has been designed to be 12.0 cm and the most inner layer of the solenoid 13.0 cm. The desired uniformity of the field, which is ~ $\pm$0.1% of the central field amplitude deviation within ~5.0$^2$$\times$3.6 ㎤ with the shortest dimension along the solenoidal axis, restricted the length of the solenoid to be at least 41.14 cm.

  • PDF