• 제목/요약/키워드: Inside diameter

검색결과 736건 처리시간 0.027초

전열면 온도의 균일분포를 위한 냉각 및 가열관의 최적 배열에 관한 연구 (A Study on the Optimal Arrangement of Heating and Cooling Tubes for Uniform Temperature Distribution of Heat Transfer Surface)

  • 민현석;이우일
    • 설비공학논문집
    • /
    • 제2권1호
    • /
    • pp.74-83
    • /
    • 1990
  • The temperature distributions inside molds with heating or cooling tubes were calculated using special boundary element method. This special boundary element method was employed in order to reduce the error for small diameter tubes. Calculated temperature was compared with results using finite element method. It was found that the current method becomes more accurate as tubes' diameter gets smaller. Optimal arrangement of tubes for uniform temperature distribution along specific surface was found. CONMIN program was employed for the optimization.

  • PDF

대구경 초전도 코일의 ?치 전류 특성 (Characteristics of the Quench Current of Superconducting Coils with Large Bore)

  • 조전욱;배준한;김해종;심기덕;성기철
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제53권6호
    • /
    • pp.368-371
    • /
    • 2004
  • The quench current characteristics of the superconducting solenoids with large diameter were experimentally investigated. Three solenoids with inside diameter of 450mm were fabricated with different tensions and different types of epoxy applications. The quench current of each solenoid was measured according to the various ramping rates of current. The highest quench current was obtained in the solenoid impregnated with epoxy after winding with tension of 20 percents of the yield strength of the superconducting wire. It was found that the quench currents were almost independent of the ramp rate of current. From the results, although the training effect in the solenoid appeared with epoxy impregnation, the quench current of solenoid impregnated with epoxy was higher than that without epoxy impregnated The test results are presented and discussed.

전자장 해석 프로그램을 이용한 와전류 문제의 해석 및 이해 (Analysis and Understanding of Eddy Current Problem using electromagnetic field Packeg)

  • 임건규;이향범
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1697-1698
    • /
    • 2006
  • When the coil with alternating current approaches to the conductor the eddy current flows in conductor. Eddy current is concentrated on the conductor surface and decrescent because of skin effect. In this paper investigated eddy current characteristic that is happened in conductor. Analyzed characteristic using electromagnetic field finite element analysis program that is commercialized to analyze value of eddy current and penetration depth. Analyzed creation value of eddy current and penetration depth in conductor that change operation frequency and the material of conductor, coil outside diameter, inside diameter, position, type of conductor from analyzed eddy current characteristic. The results, using distribution of eddy current and penetration depth data is that will help to forecast ECT(Eddy Current Testing), Eddy current application and use field, eddy current loss.

  • PDF

핀튜브 열교환기용 전관확관 유닛 개발 (Development of Hybrid Expander Unit for Fin Tube Heat Exchanger)

  • 노건상;김종남
    • 한국기계기술학회지
    • /
    • 제13권4호
    • /
    • pp.165-168
    • /
    • 2011
  • In this paper, the hybrid tube expander unit for fin and tube type heat exchanger are developed by means of enlarging and inserting the smooth tube with a small diameter to a finned tube having larger diameter. In other word, the tube expander tool that is easy to attach and remove from tube is developed. The hybrid tube expander unit developed in this study can move easily and enlarge the tube without fixing at tube sheet. Also, this unit has a function removing scales inside tube by replacing a tube expander ball.

초소형 Lapple 사이클론 집진기의 수치적 성능평가 (Numerical Performance Evaluation of an Ultra-small Lapple Cyclone Separator)

  • 박수민;권재성
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.90-95
    • /
    • 2020
  • The purpose of this study is to numerically evaluate the collection performance of an ultra-small Lapple cyclone separator for 1~10 ㎛ particles introduced at flow rate of 10 L/min. The numerical evaluation reveals that a static pressure drop occurs more dominantly inside of the cyclone separator than at the inlet and the vortex finder. Also a fluid flow in the cyclone separator is confirmed to have a helical structure heading upward in the center of cyclone separator and downward in the vicinity of wall. The investigation on dust collection efficiency of the Lapple cyclone separator shows that particles of 4~8 ㎛ diameters are collected at very lower efficiency than other sizes. Then, the cut-point diameter of the cyclone separator is 1.48 ㎛.

파이프(Annular) 형상 제품의 사출성형 조건에 따른 수축 변형에 관한 연구 (A study on shrinkage deformation according to injection molding conditions of pipe (annular) shaped products)

  • 전대선
    • Design & Manufacturing
    • /
    • 제15권2호
    • /
    • pp.36-41
    • /
    • 2021
  • The 3 dimensional Pipe (Annular) Shaped Products was selected as a test sample, then a attribute of a molding shrinkage according to the parameters of a injection process was examined with PC, which is the typical engineering plastic. Both the inside and the outside diameter of the Pipe (Annular) sample were shrank into the inner direction of the part. And then the comparative analysis of the samples proved that a increasing thickness led a bigger shrinkage rate in the equal outside diametric samples, and a decreasing outside diameter caused a bigger shrinkage rate in the same thickness samples. The comparative study of the cushion volume of a injection machine showed that the molding shrinkage was most affected by the pressure strength among the resin temperature, the maintenance pressure strength and the maintenance pressure duration time. Each of the shrinkage rates according to the measuring direction and the gate position was different. As a result, the injection molded sample had not a typical circular shape.

소형 디퓨저의 최적화 설계 (Optimization Design of Compact Diffuser)

  • 이영태
    • 반도체디스플레이기술학회지
    • /
    • 제21권4호
    • /
    • pp.163-167
    • /
    • 2022
  • In this paper, an optimization design method of a diffuser using Bernoulli's theorem was reviewed. The aspect ratio of the cylindrical diffuser chamber and the diameter ratio of the air inlet and outlet were used as design parameters. For the optimal design of the cylindrical diffuser chamber, the air flow inside the chamber was simulated using ANSYS while changing the aspect ratio of the chamber. In order to confirm the simulation results, the diffuser manufactured using the laser processing machine was measured. Through ANSYS simulation and measurement, it was found that the optimal design condition was when the aspect ratio (chamber height/radius) of the diffuser chamber was 1/2 and the diameter ratio of the air inlet and outlet was also 1/2.

수직상향 이상류에서 동심원관 간극이 유동양식과 보이드분포에 미치는 영향 (Effects of Annular Gap Size on the Flow Pattern and Void Distribution in a Vertical Upward Two-Phase Flow)

  • 손병진;김인석;김문철
    • 대한설비공학회지:설비저널
    • /
    • 제16권4호
    • /
    • pp.383-391
    • /
    • 1987
  • An experimental investigation has been conducted to determine the flow pattern for two-component , two-phase mixtures which flow vertically upwards in concentric annuli based on the measurement for the local void fraction and the distribution of the local void fraction in various radial locations in the annular gap. The annular test section consists of a lucite outer tube whose inside diameter is 38mm and a stainless steel rod, The rod diameter is either :2mm,16mm or 20mm. It is demonstrated that the probability density function of the fluctuations in void fraction may be used as an flow pattern indicator and the local void fraction distribution depends on the flow pattern and radial location in the annular passage.

  • PDF

Modeling of Pressure Drop for Water Vapor Flow across Tube Banks inside Horizontal Tube Absorber

  • Phan Thanh Tong;Yoon Jung-In;Kim Eun-Pil
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권4호
    • /
    • pp.483-493
    • /
    • 2006
  • A model for a pressure drop of water vapor flow across tube banks in a horizontal tube absorber of an absorption chiller/heater using LiBr solution as a working fluid has been developed based on a commercial 20RT(70kW) absorption chiller/heater. The numerical results show that the characteristic of the pressure drop in the shell side of the horizontal tube absorber is completely different from that in a conventional shell and tube heat exchanger. Especially, solution film thickness has significant influence on the vapor pressure drop in the horizontal tube absorber. In addition, the effects by the tube diameters, the longitudinal pitch to diameter ratio, and Reynolds number of the vapor flow, on the vapor pressure drop have been studied to evaluate the compactness of tube absorber. It was found that the vapor pressure drop decreases as tube diameter increases, the longitudinal pitch to diameter ratio increases, and Reynolds number of the vapor flow decreases. A comparison of the present study results with well-established experimental and numerical results showed a good overall agreement.

유출홀이 설치된 회전하는 정사각 유로에서의 열/물질전달 특성 (Heat/Mass Transfer Characteristics on Rotating Square Channel with Bleed Holes)

  • 김상인;김경민;이동현;이동호;조형희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1104-1109
    • /
    • 2004
  • The present study has been conducted to investigate convective heat/mass transfer inside the cooling passage with bleed holes. The rotating square channel has 40.0 mm hydraulic diameter and the bleed holes on the leading surface of the channel. The hole diameter of bleed hole is 4.5 mm and its spacing (P/d=4.9) is about five times of hole diameter. Mass flow rate through bleed holes is 10% of the main flow rate and rotation number is changed form 0.0 to 0.4. A naphthalene sublimation technique is employed to determine the detailed local heat transfer coefficients using the heat and mass transfer analogy. The cooling performance is influenced by mass flow rate through bleed holes and Coriolis force of rotating channel for fixed reynolds number. The heat transfer is enhanced around holes on the leading surface because of trapping flow by bleeding. However heat transfer on the leading surface is decreased due to Coriolis force.

  • PDF