• Title/Summary/Keyword: Insert core

Search Result 31, Processing Time 0.024 seconds

Programming Design for Operation of Proto-type In-core Neutron Detector Drive System (프로토 타입 원자로 중성자 검출기 구동시스템 구동프로그램 설계)

  • Kim, S.G.;Lee, E.W.;Shin, C.H.;Song, S.I.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07b
    • /
    • pp.675-677
    • /
    • 2001
  • The neutron controls a nuclear fission in the core of reactor. In-core neutron detector drive system is a equipment that drives detector and cable to survey neutron flux in the reactor. The program introduced by this paper governs proto-type drive system. The basic function of drive system is the insert and the withdraw of a cable, and the control of the movement speed. Also this program have a special function, test, auto operation, to increase the capacity of drive system.

  • PDF

Filling Imbalance of Elastomer TPVs in Injection Mold with Multi-Cavity (다수캐비티 사출금형에서 엘라스토머 TPV의 충전 불균형)

  • Han, Dong-Yeop;Kwon, Yun-Suk;No, Byeong-Su;Jeong, Yeong-Deug
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.2 s.191
    • /
    • pp.41-46
    • /
    • 2007
  • Recently, the study for filling imbalance in thermoplastic polymer has gradually been increased. However, it is hard to find the researches for filling imbalance of thermoplastic elastomer(TPE). The experiment of filling imbalance was conducted for the three kinds of thermoplastic vulcanizes(TPVs) in the mold with geometrically balanced runner system. In this experiment, the effects of the melt temperature and injection speed on the filling imbalance were investigated. To solve the filling imbalance, Runner Core pin(RC pin) in the experimental mold was adopted and it's effects was tested. In this paper, we present that the insert length of RC pin is dependent to each polymers for optimal filling balance.

Mold technology with 3D printing for manufacturing of porous implant (다공성 임플란트 제조를 위한 3D 프린팅 응용 금형기술)

  • Lee, Sung-Hee;Kim, Mi-Ae;Yun, Eon-Gyeong;Lee, Won-Sik
    • Design & Manufacturing
    • /
    • v.11 no.1
    • /
    • pp.30-33
    • /
    • 2017
  • In this study, the mold technology for manufacturing of porous implant was investigated. Firstly, we considered the concept of insert molding technology with 3D printing of porous inert part. The part on implant was designed in the end region of the implant. And then main implant bodies were manufactured using conventional machining method. The other porous parts were designed and optimized with molding simulation. As the feature size of porous implant was so small that perfect feature of it using 3D printing technology could not be obtained. So, we proposed another scheme for manufacturing of the porous implant in the replace of the former approach. Polymer mold cores with 3D printing technology were considered. The effects of addictive manufacturing process parameters on the properties of mechanical and dimensional accuracy were investigated. Direct 3D printed polymer mold cores were designed and manufactured under the simulation of thermal and molding analysis. It was shown that 3D printed mold core with polymer could be adapted to the injection molding for porous implant.

Arthroscopic assisted Core Decompression of Humeral Head Osteonecrosis - Technical Note - (상완 골두 골괴사증에서의 관절경하 핵심 감압술 - 수술 술기 -)

  • Cho, Chul-Hyun;Sohn, Sung-Won;Bae, Ki-Cheor;Kim, Dong-Hoo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.13 no.2
    • /
    • pp.174-178
    • /
    • 2009
  • Purpose: We introduce arthroscopic assisted core decompression for humeral head osteonecrosis. Operative technique: After diagnostic shoulder arthroscopy is performed using posterior and anterior portal, we make a 2 cm lateral skin incision approximately 3 cm distal to 1/3 of lateral margin of the acromion and place short gray cannula to prevent adjacent soft tissue injury when insert guide pin. Under C-arm fluoroscopic and arthroscopic guidance, 3 to 4 guide pins are inserted toward the necrotic area. Then we perform drilling using 7.0 mm reamer. Conclusion: We believe this technique is a less invasive approach and avoids the complications comparing to deltopectoral approach. Arthroscopic assisted core decompression is an effective procedure in management of early stage of the humeral head osteonecoris.

  • PDF

A Study on Industrial Security Outflow Prevention System Based on Network Biometric Authentication (네트워크 바이오 인증 기반 산업기술 유출방지 시스템에 관한 연구)

  • Lee, Dae-Sung
    • Convergence Security Journal
    • /
    • v.11 no.4
    • /
    • pp.31-36
    • /
    • 2011
  • Enterprise which has a core technology or organization which manages a core information will be walking into a critical situation like a ruins when organization's confidential information is outflowed. In the past confidential information that was leaked to the off-line, recently the outflow made possible through a variety of equipment at any time via the network based on the ubiquitous communication environment. In this paper, we propose to authenticate and block all packets transmitted via the network at real-time in order to prevent confidentials outflow. Especially in or der to differentiate between users who attempt to disclose confidentials, we propose to insert user's biometric informaion transparently at per-packet basis, and also verify a performance by simulation.

Drop Time Evaluation for SMART Control Rod Assembly (스마트 제어봉집합체의 낙하시간 평가)

  • Kim, Kyoung-Rean;Jang, Ki-Jong;Park, Jin-Seok;Lee, Won-Jae
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.2
    • /
    • pp.25-28
    • /
    • 2011
  • The control rod assemblies do freely fall into the reactor core by the gravity from the control rod drive mechanism. In order to achieve a rapid shutdown and control the reactor power, it is required to insert control rod assemblies as soon as possible. In this paper, we evaluated the drop time and flow characteristics caused around guide tube for SMART(System-integrated modular advanced reactor) control rod assembly. Numerical analyses are carried out with FLUENT program of computational fluid dynamics. This study results show that the drop time of the control rod assembly in the operating condition of SMART is more 20 percent rapidly than the drop time of the room temperature and ambient atmosphere condition.

Development of Cermet Cutting Tool by Powder Injection Molding

  • Chung, Seong-Taek;Kwon, Young-Sam
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.493-494
    • /
    • 2006
  • Chip breaker of cutting tool is an important feature to enhance cutting performance. Powder injection molding process was used to produce a triangular-shape cermet grooving insert which has three chip breakers. Attrition milled cermet powders were mixed with wax-based binder system in continuous twin screw extruder. Three-plate injection mold with slide cores was used to produce injection-molded parts. After molding, solvent and thermal debinding was carried out. Sintering was conducted in a batch furnace with a graphite heater. The sintered parts satisfy the requirements of dimensional tolerances and material properties.

  • PDF

Smart Glasses Cannula Guide System Development for Interventional Cardiology Procedures (중재적 심장 질환 시술을 위한 스마트 글래스 삽입관 가이드 시스템 개발)

  • Jang, Ik Gyu;Heo, Yeong Jun;Jeon, Geum Sang;Choi, Jaesoon
    • Journal of Biomedical Engineering Research
    • /
    • v.41 no.5
    • /
    • pp.173-178
    • /
    • 2020
  • Remote control intervention surgery robotic system improves treatment effect on cardiovascular patients and reduces X-ray exposure. However, at the time of the first procedure, CT (computerized tomography) and other ultrasound diagnostic equipment should be used because the operator must insert the cannula directly into the patient's leg. Improvements to this have been un-met-needs of hospitals. In this paper, we developed a system that can insert the cannula intuitively and quickly by displaying blood vessels at a glance through the system using smart wearable glasses. The core development method is as follows. In order to project augmented reality onto the surgical image, CT scan angiography image is extracted and processed. In the process, three CT-Markers are used to create a coordinate system of blood vessel images. Additionally, a reference marker is photographed on a single camera to obtain a camera coordinate system. Since the CT marker and the reference marker are in the same position, 3D registration is performed. In the text, a detailed explanation will be given.

Effect of the Heat Input on the Tensile Properties in Arc Brazing of Ferritic Stainless Steel using Cu-Si Insert Alloy (Cu-Si계 삽입금속을 사용한 페라이트계 스테인리스강의 아크 브레이징에서 인장성질에 미치는 입열량의 영향)

  • Kim, Myung-Bok;Kim, Sang-Ju;Lee, Bong-Keun;Yuan, Xin Jian;Yoon, Byoung-Hyun;Woo, In-Su;Kang, Chung-Yun
    • Korean Journal of Metals and Materials
    • /
    • v.48 no.4
    • /
    • pp.289-296
    • /
    • 2010
  • The effects of heat input and different microstructureswere investigated on the tensile-shear properties of an arc-brazed joint of theferritic stainless steel 429EM using a Cu-Si insert alloy. The brazing speed was fixed at 800 mm/min whilethe brazing current varied from 80 to 120A. For abrazing current lower than 100A, fracturing occurred at the joint root in the direction perpendicular to the tensile load. As the brazing current increased to 120A, fracturing occurred at the base metal or the joint root. The joint and the base metal had very similar yield and tensile load values. However, the amount of elongation was decreased considerably compared to when the base metal was used. The fracturing began at the triple point of the root part and was classified into three types. The difference in the tensile-shear properties was closely related to the three fracture types.

Study of Injection Molding Process of Shift Lever Using Injection Molding Analysis (사출성형해석을 통한 자동차 레버쉬프트의 사출공정에 관한 연구)

  • Park, Chul-Woo;Lee, Boo-Youn;Lee, Sang-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.6
    • /
    • pp.7-13
    • /
    • 2015
  • The production processes were reviewed through the injection analysis of the shift lever as a core component of an auto lever installed in the automatic transmission of cars. The injection analysis was carried out for the shift lever and rod among the components in a shift lever module. The shift lever and rod are designed for injection molding with the insertion of a tube, a pin cable plate, and a steel rod for securing the strength of the product. The charging time, failure of injection molding, weld line, air trap, and deformation were reviewed according to this insert. Analyses on various gate positions were carried out for reviewing the cultivation and deformation of fiber around major components, such as the generation section of manipulation feeling and assembly section, so that optimal gate conditions might be reviewed and reflected in the mold design. Finally, we plan to compare the analysis results with the production of trial products.