• Title/Summary/Keyword: Inrush

Search Result 228, Processing Time 0.02 seconds

Technique for the Prevention of Inrush Current in a TCC Reactive Power Compensator

  • Yang, Ji-Hoon;Song, Sung-Geun;Park, Seong-Mi;Park, Sung-Jun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.21 no.4
    • /
    • pp.149-158
    • /
    • 2018
  • With the propagation and spread of the new regeneration energy and increase in electricity demand, power systems tend to be decentralized, and accordingly, the use of a power system stabilizer tends to expand for the stabilization of the distribution system. Thus, typical power system stabilizer, Static Var Compensator (SVC) is developed on a variety of topologies. In addition, the trend of technology leads from SVC to Static Synchronous Compensator(STATCOM) technology development. Recently, to overcome STATCOM's conversion losses and economic disadvantages, studies of a hybrid method using STATCOM and SVC in parallel have actively been conducted. This study proposes a new Soft-Step Switching method to limit inrush current problematic in Thyristor Controlled Capacitor (TCC) method in SVC function. In addition, to reduce Statcom's capacity, groups of reactive power compensation reactor and condenser for SVC were designed.

Analysis of inrush current caused by voltage sag in three-phase transformer and induction motor (삼상 변압기와 유도전동기에서의 전압 sag에 의한 들입 전류 분석)

  • Kim, Kyoung-Nam;Ahn, Seon-Ju;Jung, Il-Yop;Moon, Sung-Il
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.307-309
    • /
    • 2005
  • This paper studies the effects caused by symmetrical and unsymmetrical voltage sags on three-phase transformer and induction machine. The voltage sag on transformer and induction machine gives rise to inrush current. This inrush current makes sag more severe. These effects depend or many elements such as sag magnitude and duration, type of sag, and fault and recovery voltage instants.

  • PDF

A Modified Current Differential Relay for Transformer Protection (변압기 보호용 수정 전류차동 계전방식)

  • 강용철;김은수;원성호
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.2
    • /
    • pp.80-86
    • /
    • 2004
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a large exciting current, which can cause mal-operation of a differential relay. This paper proposes a modified current differential relay for transformer protection. The relay calculates core-loss current from the induced voltage and the core-loss resistance; the relay calculates the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. Comparison study with the conventional differential relay with harmonic blocking is also shown. The proposed technique not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the speed of the conventional relay.

The new protective relaying scheme of power transformer using wavelet transforms (웨이브렛 변환을 이용한 새로운 변압기 보호계전 방식)

  • Kwon, G.B.;Suh, H.S.;Yoon, S.M.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.199-202
    • /
    • 2002
  • This paper presents the new protective relaying scheme as a method for discriminating of power transform's transient state associated with magnetizng inrush state and internal fault using wavelet transforms. The simulation of EMTP with respect to different fault and inrush condition in transformer have been conducted, and the result prove that the preposed method is able to discriminate between inrush magnetizing current and internal fault.

  • PDF

Magnetic Flux Saturation Analysis of Matching Transformer Considering Characteristic of Dynamic Voltage Restorer(DVR) (DVR의 특성을 고려한 매칭변압기의 자속포화 해석)

  • Shon, Jin-Geun;Kim, Dong-Joon;Kang, Min-Gu;Jeon, Hee-Jong
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.236-243
    • /
    • 2008
  • This paper analyses magnetic flux saturation of matching transformer considering characteristic of dynamic voltage restorer(DVR) system to solve voltage sags which are considered the dominant disturbances affecting power quality. This DVR consist of PWM inverter to inject arbitrary voltage, LC low pass filter and matching transformer for isolation and grid connection. However, the matching transformer has an excess of inrush current by magnetic flux saturation in the core of transformer. Due to this inrush current, the rating of matching transformers is double for needed nominal rating for protection of DVR. Therefore, in this paper, an advanced modeling method of magnetic flux saturation is used to analyze a magnitude and characteristic of magnetizing current. Simulation and experimental results considering characteristic of DVR system are provided to demonstrate the validity of the proposed analysis method.

The Effect on Real Power System by the Inrush Current of a Transformer (변압기 돌입전류에 의한 실계통 영향 분석)

  • Shin, Jeong-Hoon;Jang, Gil-Soo;Yoon, Yong-Beum
    • Proceedings of the KIEE Conference
    • /
    • 1999.11b
    • /
    • pp.318-321
    • /
    • 1999
  • This paper describes the study of the effect on real power system due to the inclusion of the MTR at Buk Che-ju TP #2. The test system in which the transformers are represented in detail and rest Che-ju systems are represented as an equivalent system on the bus is simulated by the EMTDC. Simulation results include magnitude of inrush current and voltage drop on the bus at various CB closing time, and they show the effect on Che-ju system by the inrush current of the Buk Che-ju TP #2's MTR is not considerable.

  • PDF

Numerical Algorithm for Power Transformer Protection

  • Park, Chul-Won;Suh, Hee-Seok;Shin, Myong-Chul
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.3
    • /
    • pp.146-151
    • /
    • 2004
  • The most widely used primary protection for the internal fault detection of the power transformer is current ratio differential relaying (CRDR) with harmonic restraint. However, the second harmonic component could be decreased by magnetizing inrush when there have been changes to the material of the iron core or its design methodology. The higher the capacitance of the high voltage status and underground distribution, the more the differential current includes the second harmonic during the occurrence of an internal fault. Therefore, the conventional second harmonic restraint CRDR must be modified. This paper proposes a numerical algorithm for enhanced power transformer protection. This algorithm enables a clear distinction regarding internal faults as well as magnetizing inrush and steady state. It does this by analyzing the RMS fluctuation of terminal voltage, instantaneous value of the differential current, RMS changes, harmonic component analysis of differential current, and analysis of flux-differential slope characteristics. Based on the results of testing with WatATP99 simulation data, the proposed algorithm demonstrated more rapid and reliable performance.

The protective relaying scheme of power transformer using wavelet based neural networks (웨이브렛 변환을 바탕으로 한 신경회로망을 이용한 전력용 변압기 보호 계전기법)

  • Kweon, G.B.;Yoon, S.M.;Shin, M.C.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.229-232
    • /
    • 2001
  • This paper presents the protective relaying scheme as a method for discriminating of power transform's transient state associated with magnetizng inrush state, over-exciting state and internal fault using wavelet based neural networs. The simulation of EMTP with respect to different fault, inrush condition and over-exciting condition in transformer have been conducted, and the result prove that the proposed method is able to discriminate between inrush magnetizing current and internal fault.

  • PDF

The Protective Relaying Scheme of Power Transformer Using Wavelet Based Neural Networks (웨이브렛 변환을 바탕으로 한 신경회로망을 이용한 전력용 변압기 보호 계전기법)

  • Gwon, Gi-Baek;Seo, Hui-Seok;Yun, Seok-Mu;Sin, Myeong-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.3
    • /
    • pp.134-142
    • /
    • 2002
  • This paper presents a new method for the protective relaying scheme in power transformer using wavelet based neural networks. This approach is as fellows. After approximation and detail information is extracted by daub wavelet transform from differential current of power transformer, the former is used for obtaining the rate of differential currents and restrain currents, the latter used as the input of artificial neural networks to avoid the Hiss-operation in over-exciting state and magnetizing inrush state of power transformer. The simulation of EMTP with respect to different faults, inrush conditions and over-exciting conditions in power transformer have been conducted, and the results preyed that the proposed method is able to discriminate magnetizing inrush states, over-exciting stales and internal faults.

Modified-Current-Differential Relay for Transformer Protection

  • Kang Yong-Cheol;Jin En-Shu;Won Sung-Ho
    • KIEE International Transactions on Power Engineering
    • /
    • v.5A no.1
    • /
    • pp.1-8
    • /
    • 2005
  • During magnetic inrush or over-excitation, saturation of the core in a transformer draws a significant exciting current, which can cause malfunction of a current-differential relay. This paper proposes a modified-current-differential relay for transformer protection. The relay calculates the core-loss current from the induced voltage and the core-loss resistance as well as the magnetizing current from the core flux and the magnetization curve. Finally, the relay obtains the modified differential current by subtracting the core-loss and the magnetizing currents from the conventional differential current. A comparative study of the conventional differential relay with harmonic blocking is presented. The proposed relay not only discriminates magnetic inrush and over-excitation from an internal fault, but also improves the relay speed.