• Title/Summary/Keyword: Input signal

Search Result 3,068, Processing Time 0.027 seconds

A Novel Single Phase Synchronous Reference Frame Phase-Locked Loop with a Constant Zero Orthogonal Component

  • Li, Ming;Wang, Yue;Fang, Xiong;Gao, Yuan;Wang, Zhaoan
    • Journal of Power Electronics
    • /
    • v.14 no.6
    • /
    • pp.1334-1344
    • /
    • 2014
  • A novel single phase Phase-Locked Loop (PLL) is proposed in this paper to accurately and rapidly estimate the instantaneous phase angle of a grid. A conjugate rotating vector pair is proposed and defined to synthesize the single phase signal in the stationary reference frame. With this concept, the proposed PLL innovatively sets one phase input of the PARK transformation to a constant zero. By means of a proper cancellation, a zero steady state phase angle estimation error can be achieved, even under magnitude and frequency variations. The proposed PLL structure is presented together with guidelines for parameters adjustment. The performance of the proposed PLL is verified by comprehensive experiments. Satisfactory phase angle estimation can be achieved within one input signal cycle, and the estimation error can be totally eliminated in four input cycles for the most severe conditions.

Design of Low Voltage Linear Tunable Transconductors using the Series Composite Transistor (직렬 복합 트랜지스터를 이용한 저전압 가변 트랜스컨덕터의 설계)

  • Yun, Chang-Hun;Yu, Young-Gyu;Choi, Seok-Woo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.38 no.5
    • /
    • pp.52-58
    • /
    • 2001
  • In this paper, the low voltage linear tunable transconductors using the series composite transistor are presented. Due to the series composite transistor operating in the saturation region and the triode region, the proposed circuits have wide input range at low supply voltage. The designed transconductors have been simulated by HSPICE using $0.25{\mu}m$ n-welll CMOS process. Simulation results show that the cutoff frequency is 309M Hz and the THD of less than 1.1% can be obtained for the differential input signal of up to l.5VP-P with the input signal frequency of l0MHz.

  • PDF

Fourier-Based PLL Applied for Selective Harmonic Estimation in Electric Power Systems

  • Santos, Claudio H.G.;Ferreira, Reginaldo V.;Silva, Sidelmo Magalhaes;Cardoso Filho, Braz J.
    • Journal of Power Electronics
    • /
    • v.13 no.5
    • /
    • pp.884-895
    • /
    • 2013
  • In this paper, the Fourier-based PLL (Phase-locked Loop) is introduced with a new structure, capable of selective harmonic detection in single and three-phase systems. The application of the FB-PLL to harmonic detection is discussed and a new model applicable to three-phase systems is introduced. An analysis of the convergence of the FB-PLL based on a linear model is presented. Simulation and experimental results are included for performance analysis and to support the theoretical development. The decomposition of an input signal in its harmonic components using the Fourier theory is based on previous knowledge of the signal fundamental frequency, which cannot be easily implemented with input signals with varying frequencies or subjected to phase-angle jumps. In this scenario, the main contribution of this paper is the association of a phase-locked loop system, with a harmonic decomposition and reconstruction method, based on the well-established Fourier theory, to allow for the tracking of the fundamental component and desired harmonics from distorted input signals with a varying frequency, amplitude and phase-angle. The application of the proposed technique in three-phase systems is supported by results obtained under unbalanced and voltage sag conditions.

Estimation for the Transfer Function of Transmission Line using the Temination and Input Impedances at Activated/Deactivated states (활성/비활성 상태에서의 종단과 입력 임피던스 변화를 이용한 전송선로의 전달함수 추정)

  • 이종헌;진용옥
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.1
    • /
    • pp.90-97
    • /
    • 1992
  • An estimation method for the amplitude and phase response of transmission line is discussed. and applied to narrow band ISDN subscriber line. The ABCD parameters of line are evaluated from four impedance values: the standard termination impedence at activated and deactivated stares, and the input impedances of line which can be estimated at each state. Estimating input impedence, the “chirp” signal is used as incident signal and noise effect can be reduced by ensemble averaging. These ABCD parameter estimations might be applicable to ether uniform or nonuniform line. Cleary the magnitude and phase response can be obtained from estimated ABCD parameters. The numerical simulation results for N ISDN subscriber line model are included, and the estimation error introduced by deviation in load impedence is also anlyzed.

  • PDF

Sensor Signal Processing for Estimating Gradient Values using Perturbation Input (섭동 입력을 사용한 구배 값 추정용 센서 신호 처리)

  • Lee, Sooyong
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.251-258
    • /
    • 2017
  • According to recent studies by scientists about how to search for food, homes and the mates, it is found that the gradient information plays a key role. From cells to insects and large animals, they mostly either have special sensing organism or use a strategy to measure the gradient. Use of a perturbation as an additional input is introduced for sensor signal processing in order to get the gradient information. Different from typical approach, which calculates the gradient from differentiation, the proposed processing is done by a form of integration, thus it is very robust to noise. Discrete time domain analyses are given for one, two and three input functions for the estimation of the gradients. The amplitude and the frequency of the perturbation are two important parameters for this approach. A quantitative index to measure the effects of the amplitude is developed based on the linear regression analysis. The frequency of the perturbation is to be selected high enough to finish one period of the perturbation before the property is changed significantly with respect to time. Another quantitative index is proposed for guiding the selection of the frequency.

Input-Output Decoupling Control of Multivariable System with Robustness against Feedback Loop Failure (궤환회로 고장에 대해 강인성을 갖는 다변수 시스템의 비간섭 제어)

  • 김동화
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.17 no.8
    • /
    • pp.805-815
    • /
    • 1992
  • In this paper, robust decoupling control scheme of miftivarlable systems Is studied. Design methods for Input-Output decoupling systems with robustness against signal failure In arbitrary feedback loop or actuator loop Is suggested based on the Riccati type matrix equation and state feedback, and is simulated In Turbo-Generator systems with B-Input, 2 output. The results of simulation represents the decoupled and stable response against the failure of signal In sensor or actuator loop. However, the system designed by conventional ,it ate feedback shows the unstable response. This method Is applied for robust decoupling control of the complicated multivariable systems.

  • PDF

An Adaptive UPFC Based S tabilizer forDamping of Low Frequency Oscillation

  • Banaei, M.R.;Hashemi, A.
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.197-208
    • /
    • 2010
  • Unified power flow controller (UPFC) is the most reliable device in the FACTS concept. It has the ability to adjust all three control parameters effective in power flow and voltage stability. In this paper, a linearized model of a power system installed with a UPFC has been presented. UPFC has four control loops that by adding an extra signal to one of them, increases dynamic stability and load angle oscillations are damped. In this paper, after open loop eigenvalue (electro mechanical mode) calculations, state-space equations have been used to design damping controller and it has been considered to influence active and reactive power flow durations as the input of damping controller, in addition to the common speed duration of synchronous generators as input damper signal. To increase stability, further Lead-Lag and LQR controllers, a novel on-line adaptive controller has been used analytically to identify power system parameters. Closed-loop calculations of the electro mechanical mode verify the improvement of system pole placement after controller designing. Suitable operation of adaptive controller to decrease rotor speed oscillations against input mechanical torque disturbances is confirmed by the simulation results.

An Acoustic Echo Canceler for Hands-Free Telephony, Considering Double Talk and Environment Noise (동시통화 및 주변 잡음을 고려한 핸즈프리 환경의 반향제거기)

  • Kim, Hyun-tae;Lee, Chan-Hee;Park, Jang-sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2009.10a
    • /
    • pp.471-473
    • /
    • 2009
  • In this paper, we propose a double talk and noise robust acoustic echo canceler for hands-free telephony applications. The proposed system includes a double-talk detection method that detects the double-talk durations, which uses covariance between microphone input signa and estimated microphone input signal. And proposed adaptive algorithm for estimating acoustic echo path, uses normalized auto-covariance matrix of input signal with multiplication of residual error power and projection order of AP(affine projeciton) algorithm. It is confirmed that the proposed algorithm shows better performance from acoustic interference cancellation (AIC) viewpoint in double talk and noisy environments.

  • PDF

SINR loss and user selection in massive MU-MISO systems with ZFBF

  • Hu, Mengshi;Chang, Yongyu;Zeng, Tianyi;Wang, Bin
    • ETRI Journal
    • /
    • v.41 no.5
    • /
    • pp.637-647
    • /
    • 2019
  • Separating highly correlated users can reduce the loss caused by spatial correlation (SC) in multiuser multiple-input multiple-output (MU-MIMO) systems. However, few accurate analyses of the loss caused by SC have been conducted. In this study, we define signal-to-interference-plus-noise ratio (SINR) loss to characterize it in multiuser multiple-input single-output (MU-MISO) systems, and use coefficient of correlation (CoC) to describe the SC between users. A formula is deduced to show the accurate relation between SINR loss and CoC. Based on this relation, we propose a user selection method that utilizes CoC to minimize the average SINR loss of users in massive MU-MISO systems. Simulation results verify the correctness of the relation and show that the proposed user selection method is very effective at reducing the loss caused by SC in massive MU-MISO systems.

The Design and Construction of VHF TV Translator (VHF TV TRASLATOR의 시작에 관한 연구)

  • 김원후
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.6 no.1
    • /
    • pp.38-44
    • /
    • 1981
  • This paper is for the design and construction of TV translator using in the areas where TV signal is not detectible. In this paper, theoretical design method and the scheme to decrease the intermodulation occurred by the harmonics of local oscillator are proposed. In the processes of design we have known that intermodulation of wideband IF amplifier is cannot avoidable when only single IF band is used for all the TV channels As the input vs output characteristics of TV trasnlator we have obtained the constant output signal level of +30 dBm for the input signal levels of -76dBm~-26dBm. And in the 6MHz passband, more than 95% of linearity is obtained.

  • PDF