• 제목/요약/키워드: Input power level

검색결과 587건 처리시간 0.025초

직렬 변압기를 이용한 고정밀 자동전압조절기 (High precision Automatic Voltage Regulator by using series transformer)

  • 장뢰;이화춘;정태욱;남해곤;남순열;박성준
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2008년도 하계학술대회 논문집
    • /
    • pp.574-576
    • /
    • 2008
  • Now there are two types Non-contact compensation AC automatic voltage regulator (A.V.R). One is transformer compensation regulator, whose principle is the combination of multiple compensation transformers, do the compensation by turning on and off the connections of the transformer through the multi-full bridge circuit. This method removed the mechanical drive and contacts, which increases the life and the dynamic performance of the A.V.R. However, the compensation is multilevel, and it needs many compensation transformers and switches, the circuit is complex, the compensation precision is low. Another type is PWM switch AC regulator, whose principle is getting the AC voltage from the input, then induce the AC compensation voltage through commutating and high frequency PWM transforming, and phase tracking. Here the compensation is step-less, the compensation precision is high, and the response is fast. But the circuit is complex, and it needs an inverse compensation transformer, which is difficult to realize high-power applications. In this paper, it shows an Automatic Voltage Regulator which use high frequency PWM inverter do compensation. This A.V.R has the function as the custom-power, which make the performance of the power supply in a high level.

  • PDF

Advanced Field Weakening Control for Maximum Output Power Operation of Induction Motor in a Limited Environment

  • Seo, Yong-Joo;Go, Hee-Young;Kim, Jang-Mok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.217-218
    • /
    • 2012
  • A load motor used for warship or submarine is with limited volume and weight, also specific environmental tests like impact, vibration, noise, temperature and EMC/EMI have to be satisfied. Induction motors, synchronous motors, BLDC motor and etc, are used depending on the purpose of using military equipment. Induction Motors are used for a number of military equipment more commonly due to the robust structure and simple maintenance. Domestic and foreign warships have a wide range of voltages as the DC voltage sources with battery are mainly used for them. The ${\Delta}-connection$ operation of the induction motor is required to make the maximum power in a low voltage level. But the elements' temperature of the inverter increases due to high input current when it is in the ${\Delta}-connection$ operation. Therefore, the induction motor must be driven with the Y-connection. The lack of voltage needs to be with the field weakening control. This paper suggests the optimum field weakening control algorithm to drive the induction motor with maximum power in a limited thermal and DC voltage condition.

  • PDF

EFT IEC801-4 대책용 전원케이블의 개발에 관한 연구 (A study on development of Power Cable countermeasuring EFT IEC801-4)

  • 김형근;배대환;민경찬;김동일
    • 한국항해학회지
    • /
    • 제19권2호
    • /
    • pp.107-113
    • /
    • 1995
  • Since the most of the mal-functions in the industrial equipments controlled by processors have been occured by the Electrical Fast Transient(EFT), the International Electrotechnical Commision(IEC) prepare the dummy signal to test the immunity level of the equipments controlled by processors and recommend it for the measuring. In this paper, the defined dummy EFT signal by IEC are analyzed by the spectrum analyzer in the frequency domain and studied the developed countermeasuring parts. The new developed parts are consist of the feedthrough capacitors ( $C_y$ type ) in the input and materials with high permeaility which was wound or inserted in the second layer of the Power Cable in order to increase Common Mode inductance. And it is compared inserted Permalloy to material with high permeability increasing Common Mode inductance. We could gotten a excellent insertion loss on the wide band against EFT signal. Especially, we confirm that countermeasuring Power Cable have been an excellent dynamic characteristics in computer system above the 3.6Kv. This new parts could be effectively used for industrial, MIL, and medical equipments to reduce a mal-functions on the site. Furthermore, these parts also have a good characteristics for EMI countermeasuring over the 60MHz up to several GHz band, they are also expected to be used for all kind of EMS test with IEC801-2, 3, 5 and 6 on the power distributed line.

  • PDF

단일단 어댑터를 위한 새로운 LLC 공진컨버터 (A Novel LLC Resonant Converter for Single-Stage Adapter)

  • 장상호;윤광호;노영재;강철하;김은수
    • 전력전자학회논문지
    • /
    • 제16권4호
    • /
    • pp.382-395
    • /
    • 2011
  • 본 논문에서는 다이오드정류기와 커패시터 필터로 구성된 입력전원을 가지고 동작되는 60W이하의 출력파워용량을 갖는 어댑터를 위한 새로운 LLC 공진컨버터에 대한 내용이다. 보조스위치의 동작에 의해 제안된 LLC 공진컨버터는 모든 입력전원 ($110V_{AC}$/ $220V_{AC}$) 및 부하조건에서 높은 효율특성을 가지고 전력을 전달 할 수 있다. 제안된 컨버터에 대한 동작특성에 대해 분석, 서술되어 있으며, 60W 시제품제작 및 실험을 통하여 적용 가능함을 보였다.

Two-dimensional Numerical Simulation of a Pulsed Heat Source High Temperature Inert Gas Plasma MHD Electrical Power Generator

  • Matsumoto, Masaharu;Murakami, Tomoyuki;Okuno, Yoshihiro
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.589-596
    • /
    • 2008
  • Performance of a pulsed heat source high temperature inert gas plasma MHD electrical power generator, which can be one of the candidates of space-based laser-to-electrical power converter, is examined by a time dependent two dimensional numerical simulation. In the present MHD generator, the inert gas is assumed to be ideally heated to about $10^4K$ pulsed-likely within short time(${\sim}1{\mu}s$) in a stagnant energy input volume, and the energy of high temperature inert gas is converted to the electricity with the medium of pure inert gas plasma without seeding. The numerical simulation results show that an enthalpy extraction ratio(=electrical output energy/pulsed heat energy) of several tens of % can be achieved, which is the same level as the conventional seeded non-equilibrium plasma MHD generator. Although there still exist many phenomena to be clarified and many problems to be overcome in order to realize the system, the pulsed heat source high temperature inert gas MHD generator is surely worth examining in more detail.

  • PDF

공통-모드 간섭 (CMI)에 강인한 2-전극 기반 심전도 계측 회로 (CMI Tolerant Readout IC for Two-Electrode ECG Recording)

  • 강상균;남경식;고형호
    • 센서학회지
    • /
    • 제32권6호
    • /
    • pp.432-440
    • /
    • 2023
  • This study introduces an efficient readout circuit designed for two-electrode electrocardiogram (ECG) recording, characterized by its low-noise and low-power consumption attributes. Unlike its three-electrode counterpart, the two-electrode ECG is susceptible to common-mode interference (CMI), causing signal distortion. To counter this, the proposed circuit integrates a common-mode charge pump (CMCP) with a window comparator, allowing for a CMI tolerance of up to 20 VPP. The CMCP design prevents the activation of electrostatic discharge (ESD) diodes and becomes operational only when CMI surpasses the predetermined range set by the window comparator. This ensures power efficiency and minimizes intermodulation distortion (IMD) arising from switching noise. To maintain ECG signal accuracy, the circuit employs a chopper-stabilized instrumentation amplifier (IA) for low-noise attributes, and to achieve high input impedance, it incorporates a floating high-pass filter (HPF) and a current-feedback instrumentation amplifier (CFIA). This comprehensive design integrates various components, including a QRS peak detector and serial peripheral interface (SPI), into a single 0.18-㎛ CMOS chip occupying 0.54 mm2. Experimental evaluations showed a 0.59 µVRMS noise level within a 1-100 Hz bandwidth and a power draw of 23.83 µW at 1.8 V.

접지기반 차동신호 전송을 위한 저전력 4-Gb/s 수신단 설계 (Low Power 4-Gb/s Receiver for GND-referenced Differential Signaling)

  • 이미라;김석;정영균;배준한;권기원;전정훈
    • 전자공학회논문지
    • /
    • 제49권9호
    • /
    • pp.244-250
    • /
    • 2012
  • 본 논문에서는 접지기반의 저전압 차동 입력 신호를 전달 받는 수신단에 대해 기술하였다. 공통게이트단으로 구성된 레벨시프터와 실시간 선형 이퀄라이저를 이용하여, 채널을 통과하며 왜곡된 신호의 전압 마진과 시간 마진을 확보하였다. 입력 신호의 공통모드 전압이 변하더라도, 레벨시프터에 공급되는 전류의 양을 일정하게 유지 할 수 있는 바이어스 회로를 추가하였다. 저전력 65-nm CMOS 공정으로 수신단회로를 구현하고 측정하였다. -19.7dB의 감쇄를 보이는 FR4 PCB 채널을 통해 4-Gb/s 400mVp-p 차동 신호를 수신단으로 전달하였을 때 $10^{-11}$ BER기준 0.48UI의 시간 마진을 얻을 수 있었으며, 0.30mW/Gb/s의 낮은 전력 소모를 유지하였다.

국내 화력발전산업의 연료의 효율적 배분과 CO2 저검규모 추정

  • 이명헌
    • 자원ㆍ환경경제연구
    • /
    • 제21권1호
    • /
    • pp.3-25
    • /
    • 2012
  • 일반적으로 정부규제를 포함한 여러 제약적 환경에 직먼한 기업은 생산요소 투입단계에서 요소간의 비효율적인 배분으로 인하여 적정 수준 대비 각 요소의 과잉 혹은 과소 사용이 초래된다. 본 논문에서는 국내 화력발전산업을 대상으로 적정 수준의 자본스톡 규모를 전제로 화석연료간의 효율적 배분 여부를 검증하고 각 연료별 과잉 과소 투입량을 산정한 다음 각 연료를 적정 수준으로 투입할 경우 확보할 수 있는 잠재적 $CO_2$ 감축량을 추정하였다. 1987~2008년 기간에 걸쳐 모든 화석연료에 대한 효율적 배분 조건이 기각됨에 따라 화력발전소는 주어진 연료의 시장가격으로 생산비용의 최소화를 달성하지 못하는 것으로 나타났다. 또한 두 연료간의 효율적 배분 여부를 검증한 결과 석탄과 석유 간, 석탄과 가스 간, 그리고 석유와 가스 간의 조건 모두 기각되었다. 평균적으로 석탄과 가스는 과잉 사용되었으며, 석유는 과소 투입된 것으로 나타났다. 연료간의 배분 효율화를 통하여 연간 평균적으로 1.000만 톤 이상의 $CO_2$ 감축이 가능한 것으로 추정되었다.

  • PDF

전력소비 최소화를 위한 새로운 펑션유닛의 자원 할당 알고리듬 (A New Resource Allocation Algorithm of Functional Units to Minimize Power Dissipation)

  • 인치호
    • 전기전자학회논문지
    • /
    • 제8권2호
    • /
    • pp.181-185
    • /
    • 2004
  • 본 논문에서는 산술 연산을 수행하는 연산자의 수가 많은 펑션유닛의 입력 데이터의 스위칭을 최소화하여 소비 전력을 줄인다. 따라서 회로전체의 전력 소모를 줄이기 위해 연산자가 소모하는 전력을 우선적으로 최소화하는 것은 전력 감소의 큰 효과를 가진다. 본 논문은 VLSI회로에서 전력소비에 가장 영향을 많이 미치는 펑션유닛의 연산과정에서 소비하는 전력을 최소화하는 알고리즘을 제안한다. 펑션유닛에서 모든 연산은 전력소비 정보를 가진 전력 라이브러리를 이용하여 피연산자를 스케줄링한다. 전력 라이브러리는 펑션유닛의 모든 입력에 대해 각각의 컨트롤 스텝마다 입력 데이터의 정보를 갱신하고, 그 정보는 스케줄링 과정에서 사용되어진다. 따라서 모든 연산에서 최적화된 데이터를 펑션유닛의 입력으로 하여 전력소비를 최소화 할 수 있다. 본 논문은 상위 레벨 합성 과정에서 펑션유닛에 대한 최소의 전력소비를 위하여 제안하는 알고리즘을 적용하여 실험한 결과 최대 9.4%의 전력 감소효과가 있었다.

  • PDF

고령자의 사회적 건강이 삶의 질에 미치는 영향 (Effects of the Social Health of the Aged on their Quality of Life)

  • 박영석
    • 한국콘텐츠학회논문지
    • /
    • 제13권11호
    • /
    • pp.726-739
    • /
    • 2013
  • 다가올 고령사회 고령자의 사회문제를 해결하기 위한 방안으로 사회적 건강의 필요성을 주장하고, 고령자의 사회적 건강이 삶의 질에 미치는 영향을 파악하고자 함이 주된 연구의 목적이다. 이를 위해 경기도 의왕시에 거주하고 있는 65세 이상 고령자 중 사회활동에 참가하는 고령자를 대상으로 하였으며, 총 157부가 최종분석에 사용되었다. IBM SPSS 21.0 을 이용하여 빈도분석, t-Test와 one-way ANOVA, Duncan 사후검정상관관계분석, 위계적 회귀분석을 실시하였다. 주된 연구결과는 다음과 같다. 사회인구학적 요인과 사회적 건강의 상관관계에 있어서는 경제적수준, 주관적 건강과 사회적 건강은 양(+)적인 상관관계를 나타냈으며, 요양등급은, 경제적수준, 주관적 건강은 사회적 건강과는 음(-)적인 상관관계를 나타냈다. 사회적 건강이 삶의 질에 미치는 영향에 있어서는 사회인구학적 특성 변인만을 투입한 모델1의 경우 분산설명력은 38.2%로 나타났고, 회귀모형은 유의미하였다(F=13.141, p<.001). 사회인구학적 특성과 사회적 건강 변인을 투입한 모델2의 경우 분산설명력은 13.8%로 나타났으며, 회귀모형은 유의미하였다(F=20.057, p<.001). 이상의 연구결과를 바탕으로 몇 가지 제언을 제시하였다.