• Title/Summary/Keyword: Input energy

Search Result 2,479, Processing Time 0.029 seconds

The output characteristics of the input waveform to the PZT bimorph vibrator (입력파형에 따른 PZT 바이몰프 진동자의 출력특성)

  • Kim, Yong-Hyuk;Chu, Soon-Nam
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.62 no.1
    • /
    • pp.1-5
    • /
    • 2013
  • The aim of this study is to research maximum harvesting energy by the optimal input wave condition. The voltage characteristics of the PZT bimorph were investigated in terms of the sine wave, triangle wave and square wave according to frequency range 0~70Hz. It was found that the square wave compared with a triangular wave or square wave was showed the higher output energy. PZT bimorph was mechanically vibrated by solenoid coil experiments, which revealed two voltage peak mode according to frequency. Maximum voltage at second vibration frequency 28Hz demonstrated that the generated DC voltage was proportional to the tip displacement of the bimorph and the phase difference between the input frequency and bimorph vibration frequency was 90 degree. It was expected that optimized design to harvest a much higher energy level from lower frequency vibrations.

Nonorthogonal multiple access multiple input multiple output communications with harvested energy: Performance evaluation

  • Toi Le-Thanh;Khuong Ho-Van
    • ETRI Journal
    • /
    • v.46 no.3
    • /
    • pp.432-445
    • /
    • 2024
  • This paper demonstrates improved throughput and energy efficiency of wireless communications by exploiting nonorthogonal multiple access (NOMA), multiple input-multiple output (MIMO), and radio frequency energy harvesting (EH) technologies. To assess the performance of NOMA MIMO communications with EH (MMe), we consider the nonlinear characteristics of EH devices and propose explicit expressions for throughput and outage probability. Based on our results, the system performance is significantly mitigated by EH nonlinearity and is considerably improved by increasing the number of antennas. Additionally, by appropriately adjusting the system parameters, our NOMA MMe innovation can avert complete outages while optimizing system performance. Moreover, the results demonstrate the superiority of the NOMA MMe over its orthogonal multiple access MMe counterparts.

Analysis on The Production Costs and Energy Balance of Heating Wood-Chip by Yarding Machines (집재기계에 따른 난방용 목재칩의 생산비용 및 에너지 수지분석)

  • Hwang, Jin-Sung;Oh, Jae-Heun;Kim, Joon-Soon;Cha, Du-Song
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.6
    • /
    • pp.799-805
    • /
    • 2009
  • To construct the production system of forest biomass as a small scale heating energy source, energy availability of wood-chip was examined by cost and energy balance analysis in the production process. The costs to produce wood-chip of 1 kg was calculated by yarding machines and their operational gradient conditions. As a result, 195.45~210.54 won/kg were required as production costs of wood-chip. Input energy rate (%) which is output to input energy in wood-chip production process were showed as 26.58~27.38%. Energy input rate by operational gradient was not significantly difference, and scenario B with tower yarder system appeared by more efficient than scenario A with tractor yarding system in opposition to production costs analysis.

Adaptive Buffer and Burst Scheme and Its Characteristics for Energy Saving in Core IP Networks (에너지 절약을 위해 적응적 버퍼링 기법을 이용한 버스트 구성 방법 및 특성)

  • Han, Chimoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.49 no.10
    • /
    • pp.34-42
    • /
    • 2012
  • This paper analyses the energy saving basic power models in core IP networks, and proposes the adaptive buffer and burst scheme which is a possible energy saving method, and its implementation algorithm in core IP networks. Especially this paper describes the adaptive buffer and burst scheme dynamically varying the buffering interval B according to the input traffic volume of ingress router, and explains the operation principle of proposed scheme. This method is to adjust the buffering interval B according to input traffic volume of ingress router, that is increasing the interval B when input traffic volume is low, and decreasing the interval B when input traffic volume is high between some given interval regions. This method can gets the high energy saving effect as decreasing the transition number of idle/active in networks when input traffic volume is low, and decreasing the transition number of idle/active by the continuous of burst packets in transit router when input traffic volume is high. This paper shows the increasing of asleep rate for the energy saving of core IP networks and confirms the energy saving of core IP networks by the computer simulation. We confirmed that proposed method can be save the energy of IP networks by properly trade off network performances.

Identifying the hysteretic energy demand and distribution in regular steel frames

  • Akbas, Bulent;Shen, Jay;Temiz, Hakan
    • Steel and Composite Structures
    • /
    • v.6 no.6
    • /
    • pp.479-491
    • /
    • 2006
  • Structures in seismic regions are designed to dissipate seismic energy input through inelastic deformations. Structural or component failure occurs when the hysteretic energy demand for a structure or component subject to an earthquake ground motion (EQGM) exceeds its hysteretic energy dissipation capacity. This paper presents a study on identifying the hysteretic energy demand and distribution throughout the height of regular steel moment resisting frames (SMRFs) subject to severe EQGMs. For this purpose, non-linear dynamic time history (NDTH) analyses were carried out on regular low-, medium-, and high-rise steel SMRFs. An ensemble of ninety EQGMs recorded on different soil types was used in the study. The results show that the hysteretic energy demand decreases from the bottom stories to the upper stories and for high-rise structures, most of the hysteretic energy is dissipated by the bottom stories. The decrease is quite significant, especially, for medium- and high-rise structures.

Design Principles and Validation of a Human-sized Quadruped Robot Leg for High Energy Efficiency (에너지 효율적인 인간 크기 4족 보행 로봇의 설계와 검증)

  • Yeom, Hoyeon;Ba, Dang Xuan;Bae, Joonbum
    • The Journal of Korea Robotics Society
    • /
    • v.13 no.2
    • /
    • pp.86-91
    • /
    • 2018
  • This paper presents about design efforts of a human-sized quadruped robot leg for high energy efficiency, and verifications. One of the representative index of the energy efficiency is the Cost of Transport (COT), but increased in the energy or work done is not calculated in COT. In this reason, the input to the output energy efficiency should be also considered as a very important term. By designing the robot with customized motor housing, small rotational inertia, and low gear ratio to reduce friction, high energy efficiency was achieved. Squatting motion of one leg was performed and simulation results were compared to the experimental results for validation. The developed 50 kg robot can lift the weight up to 200 kg, and during squatting, it showed high energy efficiency. The robot showed 71% input to output energy efficiency in positive work. Peak current during squatting only appears to be 0.3 A.

A Study on Fume Formation Ratio on Flux Cored Arc Welding Process (플럭스 코어드 아크 용접 공정에서의 흄 형성량에 관한 연구)

  • Yoon, Chung-Sik;Paik, Nam-Won
    • Journal of Environmental Health Sciences
    • /
    • v.25 no.3
    • /
    • pp.108-112
    • /
    • 1999
  • A study was conducted for the effects of input energy on fume formation ratios based on electrode(FFR$_{electrode}(g/kg_{electrode})),\;deposited\;metal(FFR_{weld}(g/kg_{weld}))\;and\;slag(FFR_{slag}(g/kg_{slag}))\;at\;CO_2$ flux cored arc welding on stainless steel. Experiments were run in well designed welding fume box. Six types of flux cored wires were used and three levels of current and voltages were given. The measured values of $FFR_{electrode},\;FFR_{weld},\;FFR_{slag}\;are\;7.90{\pm}1.47\;g/kg_{electrode},\;9.18{\pm}1.65\;g/kg_{\electrode},\;71.8{\pm}24.2\;g/kg_{slag}$ respectively. Fume formation ratios are not increased dramatically by input energy because of simultaneous increasing of melted electrodes, deposited metal and slag. The results indicate that the test of fume formation ratios in the research on production of low fume welding wire can be run at the fixed condition of input energy rather than various condition.

  • PDF

The MARS Simulation of the ATLAS Main Steam Line Break Experiment

  • Ha, Tae Wook;Yun, Byong Jo;Jeong, Jae Jun
    • Journal of Energy Engineering
    • /
    • v.23 no.4
    • /
    • pp.112-122
    • /
    • 2014
  • A main steam line break (MSLB) test at the ATLAS facility was simulated using the best-estimate thermal-hydraulic system code, MARS-KS. This has been performed as an activity at the third domestic standard problem for code benchmark (DSP-03) that has been organized by Korea Atomic Energy Research Institute (KAERI). The results of the MSLB experiment and the MARS input data prepared for the previous DSP-02 using the ATLAS facility were provided to participants. The preliminary MSLB simulation using the base input data, however, showed unphysical results in the primary-to-secondary heat transfer. To resolve the problems, some improvements were implemented in the MARS input modelling. These include the use of fine meshes for the bottom region of the steam generator secondary side and proper thermal-hydraulics calculation options. Other input model improvements in the heat loss and the flow restrictor models were also made and the results were investigated in detail. From the results of simulations, the limitations and further improvement areas of the MARS code were identified.

Design and Control of Novel Topology for Photovoltaic DC/DC Converter with High Efficiency under Wide Load Ranges

  • Lee, Jong-Pil;Min, Byung-Duk;Kim, Tae-Jin;Yoo, Dong-Wook;Yoo, Ji-Yoon
    • Journal of Power Electronics
    • /
    • v.9 no.2
    • /
    • pp.300-307
    • /
    • 2009
  • In this paper, design and control is proposed for a four input-series-output-series-connected ZVS full bridge converter for the photovoltaic power conditioning system (PCS). The novel topology for a photovoltaic (PV) DC/DC converter that can dramatically reduce the power rating and increase the efficiency of a PV system by analyzing PV module characteristics is proposed. The control scheme, including an input voltage controller is proposed to achieve equal sharing of the input voltage as well output voltages by a four series connected module. Design methods for ZVS power stage are also introduced. The total PV system is implemented for a 250-kW PV power conditioning system (PCS). This system has only three DC/DC converters with a 25-kW power rating and uses only one-third of the total PV PCS power. The 25-kW prototype PV DC/DC converter is introduced to verify experimentally the proposed topology. In addition, an experimental result shows that the proposed topology exhibits good performance.

A Novel Dual-Input Boost-Buck Converter with Coupled Inductors for Distributed Thermoelectric Generation Systems

  • Zhang, Junjun;Wu, Hongfei;Sun, Kai;Xing, Yan;Cao, Feng
    • Journal of Power Electronics
    • /
    • v.15 no.4
    • /
    • pp.899-909
    • /
    • 2015
  • A dual-input boost-buck converter with coupled inductors (DIBBC-CI) is proposed as a thermoelectric generator (TEG) power conditioner with a wide input voltage range. The DIBBC-CI is built by cascading two boost cells and a buck cell with shared inverse coupled filter inductors. Low current ripple on both sides of the TEG and the battery are achieved. Reduced size and power losses of the filter inductors are benefited from the DC magnetic flux cancellation in the inductor core, leading to high efficiency and high power density. The operational principle, impact of coupled inductors, and design considerations for the proposed converter are analyzed in detail. Distributed maximum power point tracking, battery charging, and output control are implemented using a competitive logic to ensure seamless switching among operational modes. Both the simulation and experimental results verify the feasibility of the proposed topology and control.