• Title/Summary/Keyword: Input energy

Search Result 2,484, Processing Time 0.028 seconds

Properties of Chemical Vapor Deposited ZrC coating layer for TRISO Coated Fuel Particle (화학증착법에 의하여 제조된 탄화지르코늄 코팅층의 물성)

  • Kim, Jun-Gyu;Kum, E-Sul;Choi, Doo-Jin;Lee, Young-Woo;Park, Ji-Yeon
    • Journal of the Korean Ceramic Society
    • /
    • v.44 no.10
    • /
    • pp.580-584
    • /
    • 2007
  • The ZrC layer instead of SiC layer is a critical and essential layer in TRISO coated fuel particles since it is a protective layer against diffusion of fission products and provides mechanical strength for the fuel particle. In this study, we carried out computational simulation before actual experiment. With these simulation results, Zirconium carbide (ZrC) films were chemically vapor deposited on $ZrO_2$ substrate using zirconium tetrachloride $(ZrCl_4),\;CH_4$ as a source and $H_2$ dilution gas, respectively. The change of input gas ratio was correlated with growth rate and morphology of deposited ZrC films. The growth rate of ZrC films increased as the input gas ratio decreased. The microstructure of ZrC films was changed with input gas ratio; small granular type grain structure was exhibited at the low input gas ratio. Angular type structure of increased grain size was observed at the high input gas ratio.

Performance of Compressor with Variable Capacity (용량가변 방식을 적용한 압축기의 성능연구)

  • 권영철;진의선;허삼행;김대훈;홍주태;문제명
    • Journal of Energy Engineering
    • /
    • v.13 no.3
    • /
    • pp.214-218
    • /
    • 2004
  • In the present study, the variation of input power and efficiency improvement of a scroll compressor applying PWM method are experimentally investigated. The cooling capacity, input power and COP are measured under the cooling operation. The input power due to the change of the condenser and the coil addition in a main current part is measured to enhance the compressor efficiency. Measured results show that the input power and COP increase with increasing the tooling capacity. And the minimum input power of the compressor is observed. By the adoption of the double system, the consumption of compressor input power is reduced, compared with the existing system.

The Evaluation of Energy Efficiency of Apartment Units after Conversion of Balconies into an Integrated Part of Interior Living Space by Computing with ECO2 Software

  • Kim, Chang-Sung
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.11-16
    • /
    • 2016
  • Purpose: International efforts to save Earth's environment against global warming and environmental pollution have been made in many countries. Energy consumption of buildings has been continuously increasing, and it has been over 40% of total energy consumption in the world. Energy consumption of buildings in Korea reaches 24% of total energy consumption. So, Korea government has executed building energy rating systems to control energy consumption of buildings. Method: This study was carried out to evaluate the energy performance of apartment unit plans according to converting balconies into living areas. For the study, six types of input models were made. Two input models(SP1 and SP 2) were the standard units that balcony areas were not converted into living areas, and four ones(EP 1, EP 2, EP 3 and EP 4) were the extended unit plans that balcony areas were turned into living areas. All of them were simulated with ECO2 software to assess building energy efficiency. Result: According to the results, the energy performance of the EP 2 and EP 4 models were 21. 8% higher than SP 1 model and 9.2% higher than SP 2 model.

Impact of energy efficiency improvement on greenhouse gas in off-season tomato farming: Evidence from Punjab, Pakistan

  • Ali, Qamar;Khan, Muhammad T.I.;Khan, Muhammad N.I.
    • Advances in Energy Research
    • /
    • v.5 no.3
    • /
    • pp.207-217
    • /
    • 2017
  • Energy consumption in agriculture is responsible for greenhouse gas emission but it can be reduced after efficient utilization of energy inputs. Therefore, the present study aims for the estimation of energy efficiency and extent of greenhouse gas reduction after benchmarking of inefficient farms in off-season tomato in Punjab province of Pakistan. Primary data were collected from 70 farmers with simple random sampling. By using data envelopment analysis, the average value of technical, pure technical and scale efficiency was 0.80, 0.92 and 0.87, respectively while increasing, constant and decreasing return to scale was observed in 33, 26 and 11 farmers, respectively. Total input energy was reduced by $12,688.91MJ\;ha^{-1}$ (13.89%) if inefficient farms used the energy inputs according to recommendations or benchmarking. A major portion of energy saving comes from fertilizers (68.79%) followed by diesel (15.70%), chemicals (5.91%), machinery (4.37%) and water (4.00%). Total greenhouse gases reduction was $499.17kg\;CO_2\;eq.ha^{-1}$ (14.57%) as a result of improvement in energy efficiency or benchmarking of inefficient farms. Agricultural extension staff should visit the vegetable farms on regular basis and give necessary information about efficient utilization of energy inputs. The government should create awareness about the optimum use of input through seminars and pamphlets.

Wet Fine Grinding of Rice Husk Ash using a Stirred Ball Mill (교반 볼밀을 이용한 왕겨재의 습식 미세분쇄에 관한 연구)

  • Park, S.J.;Kim, M.H.;Choi, Y.K.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.1 s.114
    • /
    • pp.33-38
    • /
    • 2006
  • This work was conducted to find the operating characteristics of an efficient wet grinding system designed to obtain fine rice husk ash powder. Once the rice husk was combusted and the thermal energy was recovered from the furnace, the ash was fed and pulverized in the grinding system resulting a fine powder to be used as a supplementary adding material to the portland cement. Grinding time (15, 30, 45 min), impeller speed (250, 500, 750 rpm), and mixed ratio (6.7, 8.4, 11.l, 20.9) were three operating factors examined for the performance of a wet-type stirred ball mill grinding system. For the operating conditions employed, mean diameter of fine ash powder, specific energy input, and grinding energy efficiency were in the range of $2.83{\sim}9.58{\mu}m,\;0.5{\sim}6.73kWh/kg,\;and\;0.51{\sim}3.27m^2/Wh$, respectively. With the wet-type stirred ball mill grinding system used in this study, the grinding energy efficiency decreased with the increase in total grinding time, impeller speed, and mixed ratio. The difference in specific surface area of powder linearly increased with logarithm in total number of impeller revolution and the grinding energy efficiency linearly decreased. Grinding time of 45 min, impeller speed of 500 rpm, and mixed ratio of 6.7 were chosen as the best operating condition. At this condition, mean particle diameter of the fine ash, grinding energy efficiency, grinding throughput, and specific energy input were $2.84{\mu}m,\;2.28m^2/Wh,\;0.17kg/h$, and 2.03kWh/kg, respectively. Wet fine grinding which generates no fly dust causing pollution and makes continuous operation easy, is appeared to be a promising solution to the automatization of rice husk ash grinding process.

Sensitivity Analysis for Input Parameters of a Radiological Dose Assessment Model (U. S. NRC Model) for Ingestion Pathways (오염 음식물에 의한 피폭선량 평가모델 (U. S. NRC 모델)의 입력변수에 대한 민감도분석)

  • Hwang, Won-Tae;Suh, Kyung-Suk;Kim, Eun-Han;Choi, Young-Gil;Han, Moon-Hee
    • Journal of Radiation Protection and Research
    • /
    • v.25 no.4
    • /
    • pp.233-239
    • /
    • 2000
  • The sensitivity analysis of input parameters was Performed fer an ingestion dose assessment model (U. S. NRC's Regulatory Guide 1.109 model) from routine releases of radionuclides. In this study, three kinds of typical Korean foodstuffs (rice, leaff vegetables, milk) and two kinds of radionuclides $(^{l37}Cs,\;^{131}I)$ were considered. The values of input parameters were sampled using a Latin hypercube sampling technique based on Monte Carlo approach. Sensitivity indices, which represent the influence or the importance of input parameters for predictive results, were quantitatively expressed by the partial rank correlation coefficients. As the results, the ratio of the interception fraction to the yield of agricultural plants and the human consumption rate were sensitive input parameters for the considered foodstuffs and radionuclides. Additionally, in case of milk, the transfer factor of radionuclides from animal intake to milk and the daily intake rate of feedstuffs were sensitive input parameters. The weathering removal half-life and the delay time from food production to human consumption were relatively sensitive for $^{137}Cs$ and $^{131}I$ depositions, respectively.

  • PDF

CO2 Emission Structure Analysis with Environmental Input-Output Table 2000 (환경산업연관표 2000을 이용한 산업부문의 이산화탄소(CO2) 발생 분석)

  • Kim, Yoon Kyung
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.425-450
    • /
    • 2006
  • The index of energy intensity(energy/GDP) has been a primary policy concern since it can clarify industry sectors which use energy intensively and generate $CO_2$ emission heavily. Although energy intensity index may be suitable for estimating $CO_2$ emission from an isolated industry sector, we need an index for induced $CO_2$ emission since industrial activities are interconnected in terms of input and output. By employing Environmental Input-Output Table 2000, this paper analyses the flow of energy demand and pollutants after first estimating an induced $CO_2$ emissions from various industrial sectors and economic activities. The paper reports higher induced $CO_2$ emissions from industry sectors with larger energy intensity since they produces goods or services retaining relatively considerable environmental load. Furthermore, it is shown that environmental load and $CO_2$ emissions in overall economy are likely increasing when the products of energy intensive industrial sector is used as inputs for less intensive sectors' production process. The result suggests we need consistent policy efforts to reduce energy intensity to lower $CO_2$ emissions.

  • PDF

A Material Simulation of High-Strain-Rate Deformation with Dislocations and Vacancies (전위 및 공공을 고려한 고변형률 변형에 대한 재료 시뮬레이션)

  • Choi, Deok-Kee;Ryu, Han-Kyu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.9
    • /
    • pp.1306-1313
    • /
    • 2004
  • This paper addresses a theoretical approach to calculate the amount of the stored energy during high strain-rate deformations using atomistic level simulation. The dynamic behavior of materials at high strain-rate deformation are of great interest. At high strain-rates deformations, materials generate heat due to plastic work and the temperature rise can be significant, affecting various properties of the material. It is well known that a small percent of the energy input is stored in the material, and most of input energy is converted into heat. However, microscopic analysis has not been completed without construction of a material model, which can simulate the movement of dislocations and vacancies. A major cause of the temperature rise within materials is traditionally credited to dislocations, vacancies and other defects. In this study, an atomistic material model for FCC such as copper is used to calculate the stored energy.

An Assessment of the Energy Consumption & CO2 Emission during the Construction Stage of Government Building using the Input-Output Analysis (산업연관분석법을 통한 공공청사 신축공사단계의 에너지 소비량 및 CO2 발생량 평가)

  • Choi, Young-Hun;Lee, Sang-Beom;Song, Ho-San
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2011.11a
    • /
    • pp.149-150
    • /
    • 2011
  • Recently, Goverment's Energy-saving policy in Korea as 'Green Growth' is very remarkable effort. By intensive poliicies, the private is encouraged to participate in policy. Especially, it is very important in the field of architecture and we have to work for construction of law system. However, these efforts of the government buildings for energy efficiency in use stage is as mandatory system that may occur in the construction phase and the enviromental impact of greenhouse gas reductions is not affected. For this reason, Assess the amount of the energy consumption and CO2 emissioont of Government Buildings in 2010 ordered by PPS(Public Procurement Service) in the construction phase and suggest to recognize the need for legal restrictions.

  • PDF

Development of MARS Transient Analyzer

  • Hwang, M.K.;Kim, K.D.;Jeong, J.-J.;Lee, Y.J.;Chung, B.D.
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2002.10a
    • /
    • pp.155.2-155
    • /
    • 2002
  • A visual environment for system analysis codes (hereinafter called "ViSA") has been developed to support code users in their input preparations, code executions, and output interpretations. ViSA provides a more convenient way for base input data generation and modification on a user-friendly basis. It also provides on-line graphical displays to give an in-depth understanding of transient thermal-hydraulic behaviors in nuclear power plants. This paper presents the main features of ViSA.

  • PDF