• Title/Summary/Keyword: Input current patterns

Search Result 57, Processing Time 0.026 seconds

Effect of input current patterns on dynamic electrical impedance imaging of two-phase flows (이상유동의 동적 전기 임피던스 가시화에 대한 전류패턴의 영향)

  • Chung, Soon-Il;ljaz, U.Z.;Khambampati, A.K.;Kim, Sin;Kim, Kyung-Youn;Kim, Min-Chan
    • 유체기계공업학회:학술대회논문집
    • /
    • 2006.08a
    • /
    • pp.475-478
    • /
    • 2006
  • In electrical impedance tomography (EIT) an array of electrodes is attached on the boundary of an object and small alternating currents are injected through these electrodes, and then the resulting voltages are measured. An estimation for the cross-sectional resistivity distribution in the object is obtained by using these current and voltage data in a nondestructive manner. In this paper, the electrical impedance imaging of two-phase flows undergoing rapid transient is considered with a special emphasis on the effect of the current pattern on the image reconstruction. The trigonometric current pattern, which is commonly used in the conventional static electrical impedance imaging, shows poor performance in case of the dynamic imaging considered in this work. Extensive numerical experiments are conducted with various kinds of current patterns and their effects on the image reconstruction performance are examined.

  • PDF

Switching Signal Patterns to Prevent Short Circuit of AC Choppers (교류초퍼에서 단락사고 방지를 위한 스위칭 신호 패턴)

  • Jang, Do-Hyeon;Yeon, Jae-Eul
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.9
    • /
    • pp.445-452
    • /
    • 2001
  • Two switching signal patterns are proposed to prevent short circuit of PWM ac choppers. The voltage detection method and the current detection method are proposed to execute two switching signal patterns. In the voltage detection method, the dead-time has to be inserted to the switching signals after polarity of input voltage is checked by voltage transducer at input side. In the current detection method, the direction of load current is checked by current transducer at output side, and the dead-time delay is not considered. Controlling circuit built by current detection method is simple because the dead-time delay is considered. The experimental results are presented to prevent short circuit of ac chopper safely.

  • PDF

Performance analysis of EIT bladder monitoring system according to input current patterns (주입전류 패턴에 따른 EIT 방광 모니터링 시스템의 성능분석)

  • Han, You-Jung;Khambampati, Anil Kumar;Kim, Kyung-Youn
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.164-172
    • /
    • 2019
  • Current clinical methods for diagnosing urination disorder are invasive, expensive, and very inconvenient to perform continuous monitoring. EIT is a non-invasive technique that injects electrical current through an external electrodes and measures the induced voltage to visualize the internal electrical (impedance) characteristics, which makes it possible to monitor bladder conditions with low cost. The signal characteristics of the measured voltage data changes according to the current pattern injected through the electrode and affects reconstruction performance. In this paper, image reconstruction performance is compared and analyzed according to the injected current patterns to maximize the sensitivity to the variation of bladder size.

A Study on the Analysis of Coaxial Collinear Antennas for Base Station of Mobile Communications (이동통신 기지국용 동축 코리니아 안테나의 해석에 관한 연구)

  • 임성빈;최학근
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.30A no.11
    • /
    • pp.40-47
    • /
    • 1993
  • In this paper, a method for analyzing coaxial collinear antenna for base station of mobile communications using the moment method and the transmission line theory is presented. The excited voltages at the junctions between elements are expressed as the matrix with transmission parameters and these voltages are applied to the integral equation for calculating current distribution. Here, the current distributions, input admittances, radiation patterns and gains are calculated. Calculated values of the current distributions and the input admittances show good agreement with measured values. In case of beamtilted collinear antenna, radiation pattern is simialar to measured result except side lobe.

  • PDF

An Enhanced Fuzzy ART Algorithm for The Effective Identifier Recognition From Shipping Container Image (효과적인 운송 컨테이너 영상의 식별자 인식을 위한 개선된 퍼지 ART 알고리즘)

  • 김광백
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.5C
    • /
    • pp.486-492
    • /
    • 2003
  • The vigilance threshold of conventional fuzzy ART algorithm decide whether to permit the mismatch between any input pattern and stored pattern. If the vigilance threshold was large, despite of little difference among input and stored patterns, the input pattern may be classified to new category. On the other hand, if the vigilance threshold was small, the similarity between two patterns may be accepted in spite of lots of difference and the input pattern are classified to category of the stored pattern. Therefore, the vigilance threshold for the image recognition must be experientially set for the good result. Moreover, it may occur in the fuzzy ART algorithm that the information of stored patterns is lost in the weight-adjusting process and the rate of pattern recognition is dropped. In this paper, I proposed the enhanced fuzzy ART algorithm that supports the dynamical setting of the vigilance threshold using the generalized intersection operator of fuzzy logic and the weight value being adaptively set in proportional to the current weight change and the previous weight by reflecting the frequency of the selection of winner node. For the performance evaluation of the proposed method, we applied to the recognition of container identifiers from shipping container images. The experiment showed that the proposed method produced fewer clusters than conventional ART2 and fuzzy ART algorithm. and had tile higher recognition rate.

Preparation of ITO Transparent Conductive thin film for Display at Room Temperature (디스플레이용 ITO 투명전도막의 저온 제작)

  • Kim Kyung-Hwan;Kim Hyun-Woong
    • Journal of the Semiconductor & Display Technology
    • /
    • v.4 no.4 s.13
    • /
    • pp.5-8
    • /
    • 2005
  • In this study, we prepared the ITO thin film for TOLED(Top-emitting OLED) or flexible display at room temperature using the FTS(Facing Targets Sputtering Apparatus). We observed characteristics of deposited thin films as a function of sputtering conditions. XRD patterns were independence trom oxygen gas flow and input current. But electrical and optical properties were strongly dependence. In the results, we could prepare good properties of ITO thin films resistivity of $4.27X10^{-4}[\Omega-cm]$, transmittance of over 80% at working gas pressure 1[mTorr], input current 0.6[A], oxygen gas ratio 0.3[sccm], at room temperature.

  • PDF

A High-Efficiency Bidirectional AC/DC Topology for V2G Applications

  • Su, Mei;Li, Hua;Sun, Yao;Xiong, Wenjing
    • Journal of Power Electronics
    • /
    • v.14 no.5
    • /
    • pp.899-907
    • /
    • 2014
  • This paper proposes a single-phase bidirectional AC/DC converter topology applied in V2G systems, which consists of an inverter and a bidirectional non-inverting buck-boost converter. This topology can operate in four modes: buck charging, boost charging, buck discharging and boost discharging with high input current quality and unity input power factor. The inverter switches at line frequency, which is different from conventional voltage source inverters. A bidirectional buck-boost converter is utilized to adapt to a wider charging voltage range. The modulation and control strategy is introduced in detail, and the switching patterns are optimized to reduce the current ripple. In addition, the semiconductor losses are analyzed. Simulation and experimental results demonstrate the validity and effectiveness of the proposed topology.

New Single-Phase AC-AC Converters With High-Reliability and Common-Ground Structure (새로운 공통접지 고신뢰성 AC-AC 전력변환기)

  • Kim, Jeonghun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.6
    • /
    • pp.446-453
    • /
    • 2021
  • This paper proposes enhanced single-phase pulse width modulation buck, boost, and buck-boost type ac-ac converters. The proposed converters, where input and output voltages share a common ground, require no isolated voltage sensor and have no leakage current problem. The commutation problem is solved with series-connected switching cell structures without using an additional RC snubber. In addition, with the use of the polarity of input voltage, switching patterns are determined so that the inductor currents can flow through switching devices during all operational modes. Two switches are always turned on during a half-period of the input voltage; thus, the switching loss is significantly reduced. Detailed analysis and experimental results are provided to verify the performance of the proposed converter.

Novel Anomaly Detection Method for Proactive Prevention from a Mobile E-finance Accident with User"s Input Pattern Analysis (모바일 디바이스에서의 전자금융사고 예방을 위한 사용자입력패턴분석 기반 이상증후 탐지 방법)

  • Seo, Ho-Jin;Kim, Huy-Kang
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.21 no.4
    • /
    • pp.47-60
    • /
    • 2011
  • With the increase in the use of mobile banking service, mobile banking has become an attractive target to attackers. Even though many security measures are applied to the current mobile banking service, some threats such as physical theft or penetration to a mobile device from remote side are still remained as unsolved. With aiming to fill this void, we propose a novel approach to prevent e-financial incidents by analyzing mobile device user's input patterns. This approach helps us to distinguish between original user's usage and attacker's usage through analyzing personal input patterns such as input time-interval, finger pressure level on the touch screen. Our proposed method shows high accuracy, and is effective to prevent the e-finance incidents proactively.

Comparative Analysis of Offset Voltage PWM and $V_{max}-V_{mid}$ PWM Method for 3 Phase Matrix Converter (3상 매트릭스 컨버터에 사용되는 옵셋전압 PWM 방법과 $V_{max}-V_{mid}$ PWM 방법의 비교분석)

  • Cha, Han-Ju;Kim, Woo-Jung
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.2
    • /
    • pp.285-291
    • /
    • 2009
  • In this paper, comparative analysis of offset voltage PWM method and $V_{max}-V_{mid}$ PWM method for three-phase matrix converter is addressed by using a simple analytical and graphical method. Offset voltage PWM method calculates PWM patterns in terms of offset voltage and variable slope of carrier, and it simplifies matrix converter modulation algorithm significantly. $V_{max}-V_{mid}$ PWM method generates patterns by using two phases and maintaining a remaining phase to base phase, and it is implemented in the industrial products. The most important performance criterion of modulation method is a magnitude of current ripples and it is analytically modelled. The graphical illustration of theses complex multivariable functions make per-carrier cycle and per fundamental cycle behavior of two PWM methods understood. Two modulation methods are analysed with the analytical formulas and graphics, and the analysis shows offset voltage PWM method is superior to $V_{max}-V_{mid}$ PWM method with respect to input current ripples and output voltage ripples.