Soft switching high power factor buck converter using loss less snubber circuit (무손실 스너버 회로를 이용한 소프트 스위칭 강압형 고역률 컨버터)

  • 구헌회;변영복;김성철;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.6
    • /
    • pp.77-84
    • /
    • 1997
  • buck type converter doesn't appear when an input voltag eis lower than an output voltage. This is the main reason the buck converter has not been used for high power factor converters. In this paper, soft switching high power factor buck converter is proposed. This converter is composed of diode rectifier, input capacitor can be small enough to filter input current, buck converter with loss less snubber circuit. Converter is operated in discontinous conduction mode, turn on of the switching device is a zero current switching (ZCS) and high powr factor input is obtianed. In addition, zero voltage switching (ZVS) at trun off is achieved and switching loss is reduced using loss less snubber circuit. The capacitor used in the snubber circuit raised output voltage. Therefore, proposed converter has higher output voltage and higher efficiency than conventional buck type converter at same duty factor in discontinous conduction mode operation. High power factro, efficiency, soft switching operation of proposed converter is veified by simulation using Pspice and experimental results.

  • PDF

Decoupling Control of the Modified Arago System Using Cross Compensator with Gain Scheduler Structure (게인 스케줄러 구조의 교차 보상기를 사용한 변형 아라고시스템의 비결합 제어)

  • Choi, Goon-Ho
    • Journal of the Semiconductor & Display Technology
    • /
    • v.19 no.4
    • /
    • pp.105-111
    • /
    • 2020
  • In most multiple input/output systems, one input affects two or more different outputs. Therefore, there are many inconveniences in using the actual system. In order to solve this problem, a controller that makes an input signal and an output correspond 1:1 is called a decoupling controller. In this paper, I try to implement a relatively simple decoupling controller using a cross-compensator, that is, a compensator that takes an uncorresponding output as an input value. And this cross-compensator has a gain scheduler structure in order to increase the performance. In addition, this system is designed with a distributed control structure using CAN communication, so that it can be manufactured and operated in an easier way when implementing an actual experimental system. The proposed structure is applied to the modified new Arago's disk system and tested, and through this, the effectiveness is confirmed and reported.

A New Robust Output Feedback Variable Structure Controller for Uncertain More Affine Nonlinear Systems with Mismatched Uncertainties and Matched Disturbance

  • Lee, Jung-Hoon
    • Journal of IKEEE
    • /
    • v.18 no.2
    • /
    • pp.206-213
    • /
    • 2014
  • In this note, a new robust nonlinear output feedback variable structure controller is first systematically and generally designed for the output control of more affine uncertain nonlinear systems with mismatched uncertainties and matched disturbance. A transformed integral output feedback sliding surface with a most simple form is applied in order to remove the reaching phase problems. The closed loop exponential stability and the existence condition of the sliding mode on the integral output feedback sliding surface is investigated with a corresponding output feedback control input in Theorem 1. For practical application the continuous implementation of the control input is made by the modified saturation function. The effectiveness of the proposed controller is verified through a design example and simulation study.

Measuring the Degree of Integration into the Global Production Network by the Decomposition of Gross Output and Imports: Korea 1970-2018

  • KIM, DONGSEOK
    • KDI Journal of Economic Policy
    • /
    • v.43 no.3
    • /
    • pp.33-53
    • /
    • 2021
  • The import content of exports (ICE) is defined as the amount of foreign input embodied in one unit of export, and it has been used as a measure of the degree of integration into the global production network. In this paper, we suggest an alternative measure based on the decomposition of gross output and imports into the contributions of final demand terms. This measure considers the manner in which a country manages its domestic production base (gross output) and utilizes the foreign sector (imports) simultaneously and can thus be regarded as a more comprehensive measure than ICE. Korea's input-output tables in 1970-2018 are used in this paper. These tables were rearranged according to the same 26-industry classification so that these measures can be computed with time-series continuity and so that the results can be interpreted clearly. The results obtained in this paper are based on extended time-series data and are expected to be reliable and robust. The suggested indicators were applied to these tables, and, based on the results we conclude that the overall importance of the global economy in Korea's economic strategy has risen and that the degree of Korea's integration into the global production network increased over the entire period. This paper also shows that ICE incorrectly measures the movement of the degree of integration into the global production network in some periods.

Control of a Single Phase Unified Power Quality Conditioner-Distributed Generation Based Input Output feedback Linearization

  • Mokhtarpour, A.;Shayanfar, H.A.;Bathaee, M.;Banaei, M.R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.6
    • /
    • pp.1352-1364
    • /
    • 2013
  • This paper describes a novel structure for single phase Unified Power Quality Conditioner-Distributed Generation (UPQC-DG) with direct grid connected DC-AC converter for low DC output DG systems which can be used not only for compensation of power quality problems but also for supplying of load power partly. This converter has been composed of one full-bridge inverter, one three winding high frequency transformer with galvanic isolation and two cycloconverters. Proper control based on Input Output feedback Linearization is used to tracking the reference signals. The simulation and experimental results are presented to confirm the validity of the proposed approach.

Single Input Multi Output DC/DC Converter: An Approach to Voltage Balancing in Multilevel Inverter

  • Banaei, M.R.;Nayeri, B.;Salary, E.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1537-1543
    • /
    • 2014
  • This paper presents a new DC/AC multilevel converter. This configuration uses single DC sources. The proposed converter has two stages. The first stage is a DC/DC converter that can produce several DC-links in the output. The DC/DC converter is one type of boost converter and uses single inductor. The second stage is a multilevel inverter with several capacitor links. In this paper, one single input multi output DC-DC converter is used in order to voltage balancing on multilevel converter. In addition, as compare to traditional multilevel inverter, presented DC/AC multilevel converter has less on-state voltage drop and conduction losses. Finally, in order to verify the theoretical issues, simulation and experimental results are presented.

Coherent Analysis of HVAC Using the Multi-Dimensional Spectral Analysis (다차원 스펙트럼 해석법을 이용한 자동차 공조시스템의 기여도분석)

  • Hwang, Dong-Kun;Oh, Jae-Eung;Lee, Jung-Youn;Kim, Sung-Soo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.999-1004
    • /
    • 2004
  • In this study, we identify contribution of structure-borne-noise of vehicle HVAC system using Multi-Dimensional spectral analysis (MDSA) method. Firstly, to identify the applicability of MDSA method, the case of HVAC system was modeled with four input / single output system. The four inputs which is given vibration data is composed of blower, evaporator, heater and duct. The single output is noise data from driver's seat. When the blower motor is operating, we analyze the contributions of four input / single output. As a result of experiment, we identify efficiency of systems modeled with four input / single output through ordinary coherence function (OCF) and multiple coherence function (MCF).

  • PDF

Identification of a Parametric ARX Model of a Steam Generation and Exhaust Gases for Refuse Incineration Plants (소각 프린트의 증기발생 및 배기가스에 대한 파라메트릭 ARX 모델규명)

  • Hwang, Lee-Cheol
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.8 no.7
    • /
    • pp.556-562
    • /
    • 2002
  • This paper studies the identification of a combustion model, which is used to design a linear controller of a steam generation quantity and harmful exhaust gases of a Refuse Incineration Plant(RIP). Even though the RIP has strong nonlinearities and complexities, it is identified as a MIMO parametric ARX model from experimental input-output data sets. Unknown model parameters are decided from experimental input-output data sets, using system identification algorithm based on Instrumental Variables(IV) method. It is shown that the identified model well approximates the input-output combustion characteristics.

Design and Measurement of SFQ DFFC and Inverter (단자속 양자 DFFC와 Inverter의 설계와 측정)

  • 정구락;홍희송;박종혁;임해용;강준희;한택상
    • Progress in Superconductivity
    • /
    • v.5 no.1
    • /
    • pp.17-20
    • /
    • 2003
  • We have designed and measured a SFQ(Single Flux Quantum) DFFC and an Inverter(NOT) for superconducting ALU(Arithmetic Logic Unit) development. To optimize the circuit, we used Julia, XIC, and L meter for circuit simulations and circuit layouts. The Inverter was consisted of a D Flip-Flop, a data input, a clock input and a data output. If a data pulse arrives at the inverter, then the output reads ‘0’ (no output pulse is produced) at the next clock period. If there is no input data pulse, it reads out ‘1’(output pulse is produced). The DFFC was consisted of a D flip-Flop, an Inverter, a Data in, a Clock in and two outputs. If a data pulse arrives at the DFFC circuit, then the output2 reads ‘1’ at the next clock period, otherwise it reads out ‘1’ to output1. Operation of the fabricated chip was performed at the liquid helium temperature and at the frequencies of 1KHz.

  • PDF

The Identification of Generation Mechanism of Noise and Vibrtaion and Transmission Characteristics for Engine System - The Source Identification and Noise Reduction of Compartment by Multidimensional Spectral Analysis and Vector Synthesis Method - (엔진의 소음.진동발생기구 및 전달특성 규명 -다차원해석법과 벡터합성법에 의한 차실소음원 규명 및 소음저감 -)

  • O, Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.7
    • /
    • pp.1127-1140
    • /
    • 1997
  • With the study for identifying the transmission characteristics of vibration and noise generated by operating engine system of a vehicle, recently many engineers have studied actively the reduction of vibration and noise inducing uncomfortableness to the passenger. In this study, output noise was analyzed by multi-dimensional spectral analysis and vector synthesis method. The multi-dimensional analysis method is very effective in case of identification of primary source, but this method has little effect on suggestion for interior noised reduction. For compensation of this, vector synthesis method was used to obtain effective method for interior noise reduction, after identifying primary source for output noise. In this paper, partial coherence function of each input was calculated to know which input was most coherent to output noise, then with simulation of changes for input magnitude and phase by vector synthesis diagram, the trends of synthesized output vector was obtained. As a result, the change of synthesized output vector could be estimated.