• Title/Summary/Keyword: Input Current Improvement

Search Result 182, Processing Time 0.029 seconds

A study on imaging device sensor data QC (영상장치 센서 데이터 QC에 관한 연구)

  • Dong-Min Yun;Jae-Yeong Lee;Sung-Sik Park;Yong-Han Jeon
    • Design & Manufacturing
    • /
    • v.16 no.4
    • /
    • pp.52-59
    • /
    • 2022
  • Currently, Korea is an aging society and is expected to become a super-aged society in about four years. X-ray devices are widely used for early diagnosis in hospitals, and many X-ray technologies are being developed. The development of X-ray device technology is important, but it is also important to increase the reliability of the device through accurate data management. Sensor nodes such as temperature, voltage, and current of the diagnosis device may malfunction or transmit inaccurate data due to various causes such as failure or power outage. Therefore, in this study, the temperature, tube voltage, and tube current data related to each sensor and detection circuit of the diagnostic X-ray imaging device were measured and analyzed. Based on QC data, device failure prediction and diagnosis algorithms were designed and performed. The fault diagnosis algorithm can configure a simulator capable of setting user parameter values, displaying sensor output graphs, and displaying signs of sensor abnormalities, and can check the detection results when each sensor is operating normally and when the sensor is abnormal. It is judged that efficient device management and diagnosis is possible because it monitors abnormal data values (temperature, voltage, current) in real time and automatically diagnoses failures by feeding back the abnormal values detected at each stage. Although this algorithm cannot predict all failures related to temperature, voltage, and current of diagnostic X-ray imaging devices, it can detect temperature rise, bouncing values, device physical limits, input/output values, and radiation-related anomalies. exposure. If a value exceeding the maximum variation value of each data occurs, it is judged that it will be possible to check and respond in preparation for device failure. If a device's sensor fails, unexpected accidents may occur, increasing costs and risks, and regular maintenance cannot cope with all errors or failures. Therefore, since real-time maintenance through continuous data monitoring is possible, reliability improvement, maintenance cost reduction, and efficient management of equipment are expected to be possible.

Identification of Motor Parameters and Improvement of Voltage Error for Improvement of Back-emf Estimation in Sensorless Control of Low Speed Operation (저속 센서리스 제어의 역기전력 추정 성능 향상을 위한 모터 파라미터 추정과 전압 오차의 개선)

  • Kim, Kyung-Hoon;Yun, Chul;Cho, Nae-Soo;Jang, Min-Ho;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.5
    • /
    • pp.635-643
    • /
    • 2018
  • This paper propose a method to identify the motor parameters and improve input voltage error which affect the low speed position error of the back-emf(back electromotive force) based sensorless algorithm and to secure the operation reliability and stability even in the case where the load fluctuation is severe and the start and low speed operation frequently occurs. In the model-based observer used in this paper, stator resistance, inductance, and input voltage are particularly influential factors on low speed performance. Stator resistance can cause resistance value fluctuation which may occur in mass production process, and fluctuation of resistance value due to heat generated during operation. The inductance is influenced by the fluctuation due to the manufacturing dispersion and at a low speed where the change of the current is severe. In order to find stator resistance and inductance which have different initial values and fluctuate during operation and have a large influence on sensorless performance at low speed, they are commonly measured through 2-point calculation method by 2-step align current injection. The effect of voltage error is minimized by offsetting the voltage error. In addition, when the command voltage is used, it is difficult to estimate the back-emf due to the relatively large distortion voltage due to the dead time and the voltage drop of the power device. In this paper, we propose a simple circuit and method to detect the voltage by measuring the PWM(Pulse Width Modulation) pulse width and compensate the voltage drop of the power device with the table, thereby minimizing the position error due to the exact estimation of the back-emf at low speed. The suitability of the proposed algorithm is verified through experiment.

Survey on the Actual Condition and the Improvement Factors of Foreign Workers at the Construction Site. (건설현장 외국인근로 실태조사 및 개선요소 도출)

  • Baek, Nak-Ku;Hong, Jun-Pyo;Lim, Hyoung-chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.136-145
    • /
    • 2018
  • Companies that have suffered serious labor shortages are relocating their factories abroad where they can solve this problem by increasing the employment of foreign workers. Construction sites also employ foreign workers to supplement the scarce manpower, and the demand for foreign workers has been gradually increasing over time. Recently, based on discussions on whether or not to introduce foreign workers, the policy on the input of foreign workers into domestic construction sites has been shifted to exploring the actual input conditions and efficient management methods. In this study, we investigated the current status and input situation of foreign workers at the construction sites of the target area, analyzed the problems they posed from the manager's viewpoint, and derived a method of improving the utilization of foreign workers at construction sites. In order to proceed with this study, we surveyed the actual situation of the construction sites, which consisted mainly of foreign workers and domestic workers (managers), by investigating the construction sites, and conducted 1: 1 interviews to ensure the reliability of the survey. The data obtained from the survey were analyzed using the SPSS analysis program, and the response rate was analyzed for each item. As a result, various problems, such as institutional problems, communication problems, and quality deterioration due to malfunction, appeared. Therefore, this study derives an improvement plan for the efficient utilization of foreign workers by improving the institutional level related to their language education, wages and employment.

DEVELOPMENT OF SAFETY-BASED LEVEL-OF-SERVICE PARAMETERS FOR TWO-WAY STOP-CONTROLLED INTERSECTIONS (무신호 교차로의 안전 -서비스 수준 측정에 관한 연구-)

  • 이수범
    • Proceedings of the KOR-KST Conference
    • /
    • 1996.02a
    • /
    • pp.59-86
    • /
    • 1996
  • Current methods for evaluating unsignalized intersections, and estimating level-of-service (LOS) is determined from efficiency-based criteria such as little or no delay to very long delays. At present, similar procedures to evaluate intersections using safety-based criteria do not exist. The improvement of sight distances at intersections is the most effective way of improving intersection safety. However, a set of procedures is necessary to account for the limitations in current methodology. Such an approach would build upon such methods, but also account for: deficiencies in the current deterministic solution for the determination of intersection sight distances; opportunity for an accident and severity of an accident; and cost-effectiveness of attaining various levels of sight distances. In this research, a model that estimates the degree of safety at two-way stop-controlled intersections is described. Only crossing maneuvers are considered in this study because accidents caused by the crossing maneuvers are the dominate type among intersection accidents. Monte Carlo methods are used to estimate the hazard at an intersection as a function of roadway features and traffic conditions. Driver`s minimum gap acceptance in the crossing vehicles and headway distribution on the major road are used in the crossing vehicles and headway distribution on the major road are used in the model to simulate the real intersectional maneuvers. Other random variables addressed in the model are: traffic speeds; preception-reaction times of both drivers in the crossing vehicles and drivers in oncoming vehicles on the major road; and vehicles on the major roads. The developed model produces the total number of conflicts per year per vehicle and total potential kinetic energy per year per vehicle dissipated during conflicts as measurements of safety at intersections. Based on the results from the developed simulation model, desirable sight distances for various speeds were determined as 350 feet, 450 feet and 550 feet for 40 mph, 50 mph and 60 mph prevailing speed on the major road, respectively. These values are seven to eight percent less than those values recommended by AASHTO. A safety based level-of-service (LOS) is also developed using the results of the simulation model. When the total number of conflicts per vehicle is less than 0.05 at an intersection, the LOS of the intersection is `A' and when the total number of conflicts per vehicle is larger than 0.25 at an intersection, the LOS is `F'. Similarly, when the total hazard per vehicle is less than 350, 000 1b-ft2/sec2, the LOS is `F'. Once evaluation of the current safety at the intersection is complete, a sensitivity analysis can be done by changing one or more input parameters. This will estimate the benefit in terms of time and budget of hazard reduction based upon improving geometric and traffic characteristics at the intersection. This method will also enable traffic engineers in local governments to generate a priority list of intersection improvement projects.

  • PDF

Electronic Ballast Design for Power Factor Improvement and Harmonic Reduction (역률개선 및 고조파 저감을 위한 전자식 안정기 설계)

  • Lee, Chung-Sik;Cho, Moon-Taek;Na, Seung-Kwon
    • Journal of Advanced Navigation Technology
    • /
    • v.18 no.5
    • /
    • pp.483-489
    • /
    • 2014
  • Proposed electronic ballast circuit for harmonic reduction includes adding lossless snubber circuit to DC-DC converter. To get inverter for changing DC-AC, a lamp has been changed to equivalence resistance in the standard lamp voltage and current data, also inverter circuit has been interpreted by being changed to R, L, C equivalence circuit. Using converted equivalent circuit, the most suitable circuit constant which can satisfy the characteristics of fluorescent lamps has been decided on and finally designed. It could not only eliminate distortion waveform from pulsation frequency in inverter direct side current but also reduce considerably pulsation rate and switching loss by making input current of inverter discontinuous. The validity for the results of this study has been verified through the experiment to measure harmonic occurrence after applying a newly-manufactured product of electronic ballast to 40 W line tube style fluorescent lamps.

Harmonics reduction by accuracy of DC shaping of power converters (전력변환장치의 직류 파형 개선을 통한 고조파 저감)

  • Kim, Jongsu;Ahn, Jaehong;Kim, Seonghwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1131-1136
    • /
    • 2014
  • Recently, power converters installed on the specialized vessels such as LNG Carrier and Icebreaker and offshore plants mainly use diode rectifier. However, such devices cause distortion of supply voltage waveform by involving much harmonics to input current of non linearity load in rectifying operation. Distortion of supply voltage waveform can be problems such as false operation of generator, transformer and load device and deterioration of power quality. This thesis is focusing with a view to producing accurate sinusoidal AC waveform with certain load through improvement of distortion of current waveform causing under operation of rectifier by using accurate circuit of DC shaping. The result of computer simulation proved that harmonics involved in current and voltage waveform of power system can be reduced.

A zero-voltage zero-current switching power conversion system for fuel cell (영전압 영전류 스위칭을 이용한 연료전지용 전력변환시스템)

  • Son, Gyoung-Jong;Song, Sung-Geun;Moon, Chae-Joo;Kim, Kwang-Heon;Lim, Young-Cheol;Choi, Joon-Ho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.385-394
    • /
    • 2006
  • The application areas of traditional push-pull converters are limited because the voltage stress of switches is high (twice of the input voltage). But the push - pull converter topology is suitable for unregulated low-voltage to high-voltage power conversion such as the fuel cell. This paper presents a novel power converter structure that is very suitable for the DC/DC converter in fuel cell systems. Based on this structure, a ZVS- ZCS push-pull converter is proposed. The switches of the proposed push-pull converter can operate under ZVS or ZCS condition with the help of a new passive clamping circuit. The passive clamping techniques solves the voltage overshoot problem. Because the buck converter circuit operates at twice the synchronous switching frequency of the push-pull converter, the peak current in the current-fed inductor and transformer is reduced. The operation principle of the proposed converter is analyzed and verified by simulations and experimental results. A 1 kW DC/DC converter was implemented with DSP TMS320F2812, from which experimental results have shown that efficiency improvement and surge suppression can be achieved effectively.

Study on the Improvement of Nitrate Removal Efficiency in Multi-Step Electro-chemical Process (전기화학적공정에서 질산성질소 제거효율 향상에 관한 연구)

  • Sim, Joo-Hyun;Kang, Se-Han;Seo, Hyung-Joon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.30 no.2
    • /
    • pp.155-160
    • /
    • 2008
  • In this study, the nitrate removal efficiency was examined under a variety of operating conditions, such as different doses of the reducing agent, different electrode types, different HRTs(hydraulic retention times), and different current densities, using the multistep electrochemical process. The nitrate removal efficiency increased and the input energy decreased when the reducing agent was used, and almost no difference was found between the electrode types in terms of their nitrate removal efficiency and current efficiency. So that the Zn reducing agent could be recovered, though, the B-type electrode was chosen(step 1: Pt-Zn; step 2: Pt-Zn; step 3: Pt-Zn; step 4: Pt-Zn). HRT experiments were carried out on constant electric current density unrelated HRTs and various electric current density related HRTs: the constant amount of electric current per unit volume. As a result, HRT and the electric current density caused concentration polarization and the lack of an applied current. That is to say,the lower the HRT, the greater the decrease in concentration polarization and in the amount of applied current per unit volume. Therefore, optimal conditions were found through the experiments that were conducted on HRT and electric current density. When a spacer was installed in the process, the nitrate removal efficiency and energy efficiency increased even more because the diffusion likewise increased.

Harmonic Reduction Scheme By the Advanced Auxiliary Voltage Supply (개선된 보조전원장치에 의한 고조파 저감대책)

  • Yoon, Doo-O;Yoon, Kyoung-Kuk;Kim, Sung-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.759-769
    • /
    • 2015
  • Diode rectifiers are very popular in industry. However, they include large low-order harmonics in the input current and do not satisfy harmonic current content restrictions. To reduce the harmonics to the power system, several methods have been introduced. It is heavy and expensive solution to use passive filters as the solution for high power application. Another solution for the harmonic filter is utilization of active filter, but it is too expensive solution. Diode rectifiers with configurations using switching device have been introduced, but they are very complicated. The combined 12-pulse diode rectifier with the square auxiliary voltage supply has been introduced. It has the advantages that auxiliary circuit is simple and inexpensive compared to other strategies. The advanced auxiliary voltage supply in this thesis is presented as a new solution. When the square auxiliary voltage supply applied, the improvement of THD is 6~60[%] in whole load range. But when the advanced auxiliary voltage supply applied, it shows stable and excellent reduction effect of THD as 57~71[%]. Especially, for the case with 10[%] load factor, reduction effect of THD has little effect as 6[%] in the case of inserting a square auxiliary voltage supply. But when the proposed new solution applied, reduction effect has excellent effect as 71[%]. Theoretical analysis of the combined 12-pulse diode rectifier with the advanced auxiliary voltage supply is presented and control methods of the auxiliary supply is proposed. The reduction in the input current harmonics is verified by simulation using software PSIM.

Determination and Performance Evaluation of Codevectors Utilizing Phase Difference Distribution Characteristics of Circular Antenna Arrays (원형 안테나 배열의 위상 차이 분포 특성을 활용한 코드벡터 결정 방식 및 성능 평가)

  • Kim, Huiwon;Suh, Junyeub;Sung, Wonjin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.10
    • /
    • pp.3-9
    • /
    • 2016
  • Current mobile communication systems utilize the multiple-input multiple-output (MIMO) transmission technique as an important means to enhance the bandwidth efficiency. Accurate beamforming via channel estimation contributes to the signal-to-interference-plus-noise ratio (SINR) increase and the system performance improvement when MIMO transmission techniques are employed. Therefore, determination of beamforming vectors as well as the design of appropriate codebooks defining these codevectors play an important role in system operation. In this paper, we statistically analyze the phase difference between the channels corresponding to adjacent antenna elements in order to design an efficient codebook for uniform circular arrays (UCAs). We introduce new parameters which compensate for the additional phase difference observed in its probability density functions (PDFs). The performance of the proposed codebook is tested using the spatial channel model (SCM) to demonstrate its gain over the standard codebooks adopted in the long term evolution (LTE) Releases 8 and 10.