• Title/Summary/Keyword: Input Condition

검색결과 1,854건 처리시간 0.031초

극박 다이아프램의 펄스 GTAW 공정 최적화에 관한 연구 (Study on the Optimization of Pulse GTAW Process for Diaphragm with Thin Thickness)

  • 박형진;황인성;강문진;이세헌
    • Journal of Welding and Joining
    • /
    • 제26권1호
    • /
    • pp.63-68
    • /
    • 2008
  • This paper has aimed to prevent excessive heat input by controlling arc distribution and heat input capacity with pulse GTAW in order to improve weld quality in 0.08mm pressure gauge diaphragm and flange welding parts. A design of experiment was designed using Box-Behnken method to optimize a welding process. The pulse GTAW parameters such as pulse current, base current, pulse duty, frequency and welding speed were set to input variables while hydraulic pressure that represents welding characteristics in diaphragm and flange joint were set to output variables. Based on the test result, a second regression equation was obtained between input and output variables and turned out significant. Besides, an influence of parameters has been confirmed through response surface analysis using the second-order regression equation and optimum welding condition was obtained through a grid-search method. The optimum welding condition was set to pulse current 84.4(A), base current 29.6(A), pulse duty 58.8(%), frequency 10(%), and welding speed 596(mm/min). Then, decent bead shape was acquired with no excessive heat input under the $2.3kgf/cm^2$ of hydrostatic pressure.

입력전류와 커패시터 전압의 맥동저감을 위한 개선된 LCCT Z-소스 DC-AC 인버터 (Improved LCCT Z-Source DC-AC Inverter for Ripple Reduction of Input Current and Capacitor Voltage)

  • 신연수;정영국;임영철
    • 전기학회논문지
    • /
    • 제61권10호
    • /
    • pp.1432-1441
    • /
    • 2012
  • In this study, an improved LCCT(Inductor-Capacitor-Capacitor-Trans) Z-source inverter(Improved LCCT ZSI) with characteristics of Quasi Z-source inverter(QZSI) and LCCT Z-source inverter(LCCT ZSI) is proposed. The proposed inverter can also reduce the voltage stress and input current/capacitor voltage ripples compared with conventional LCCT ZSI and Quasi ZSI. A two winding trans in Z-impedance network of the conventional LCCT ZSI is replaced by a three winding trans in the proposed inverter. To verify the validity of the proposed inverter, a DSP controlled hardware was made and PSIM simulation was executed for each method. Comparing the current and voltage ripples of each method under the condition of input DC voltage 70[V] and output AC voltage 76[Vrms], the input current and capacitor voltage ripple factors of the proposed inverter were low as 11[%] and 1.4[%] respectively. And, for generation of the same output AC voltage of each method, voltage stress of the proposed inverter was low as 175[V] under the condition of duty ratio D=0.15. As mentioned above, we could know that the proposed inverter have the characteristics of low voltage stress, low ripple factor and low operation duty ratio compared with the conventional methods. Finally, the efficiency according to load change/duty ratio and the transient state characteristics were discussed.

공기 중 메틸에틸케톤 제어를 위한 Pilot-Scale 흡수 시스템의 운영인자 분석 (Analysis of Operation Parameters of Pilot-Scale Packed-Absorption System for Airborne Methyl Ethyl Ketone Control)

  • 조완근;김왕태
    • 한국환경과학회지
    • /
    • 제20권4호
    • /
    • pp.501-509
    • /
    • 2011
  • Unlike many laboratory-scale studies on absorption of organic compounds (VOCs), limited pilot-scale studies have been reported. Accordingly, the present study was carried out to examine operation parameters for the effective control of a hydrophilic VOC (methyl ethyl ketone, MEK) by applying a circular pilot-scale packed-absorption system (inside diameter 37 cm ${\times}$ height 167 cm). The absorption efficiencies of MEK were investigated for three major operation parameters: input concentration, water flow rate, and ratio of gas flow-rate to washing water amount (water-to-gas ratio). The experimental set-up comprised of the flow control system, generation system, recirculation system, packed-absorption system, and outlet system. For three MEK input concentrations (300, 350, and 750 ppm), absorption efficiencies approached near 95% and then, decreased gradually as the operation time increased, thereby suggesting a non-steady state condition. Under these conditions, higher absorption efficiencies were shown for lower input concentration conditions, which were consistent with those of laboratory-scale studies. However, a steady state condition occurred for two input concentration conditions (100 and 200 ppm), and the difference in absorption efficiencies between these two conditions were insignificant. As supported by an established gas-liquid absorption theory, a higher water flow rate exhibited a greater absorption efficiency. Moreover, as same with the laboratory-scale studies, the absorption efficiencies increased as water-to-gas ratios increased. Meanwhile, regardless of water flow rates or water-to-gas ratios, as the operation time of the absorption became longer, the pH of water increased, but the elevation extent was not substantial (maximum pH difference, 1.1).

자성유체를 이용한 우퍼 스피커의 보이스 코일 온도 특성에 관한 수치적 연구 (Numerical Analysis on Temperature Characteristics of the Voice-Coil for Woofer Speaker Using Ferrofluid)

  • 이무연;김형진;이우영
    • 한국자기학회지
    • /
    • 제23권5호
    • /
    • pp.166-172
    • /
    • 2013
  • 본 연구는 자성유체 우퍼 스피커 내부에 위치한 보이스 코일의 입력전류에 따른 열전달 특성을 수치 해석적으로 고찰하는 것이다. 이를 위하여 일반 우퍼 스피커 및 자성유체 우퍼 스피커에 대하여 입력전류를 10W에서 50W로 10W씩 변화시켜가면서 입력전류에 따른 보이스 코일 발열 및 각 부품으로 전달되는 열전달 및 온도 특성 변화를 고찰하였다. 그 결과 우퍼 스피커에 공급되는 입력전류가 증가함에 따라 보이스 코일 온도가 선형적으로 증가하였고 자성유체 우퍼 스피커의 보이스 코일 온도가 일반 우퍼 스피커에 비하여 동일 입력 전류 40 W 기준에서 51.0 % 감소하였고, 동일 보이스 코일 발생 온도 490 K 기준에서 필요 입력전류는 42.5 % 감소하였다. 또한 보이스 코일에서 주변 부품으로 열전달은 자성유체 우퍼 스피커가 일반 우퍼 스피커에 비하여 51.7 % 증가하였다.

시변 시간지연 하에서 안정성을 보장하는 양방향 원격제어기 : 시간영역 수동성 기법 (Bilateral Controller for Time-varying Communication Delay: Time Domain Passivity Approach)

  • 유지환
    • 제어로봇시스템학회논문지
    • /
    • 제13권11호
    • /
    • pp.1099-1105
    • /
    • 2007
  • In this paper, modified two-port time-domain passivity approach is proposed for stable bilateral control of teleoperators under time-varying communication delay. We separate input and output energy at each port of a bilateral controller, and propose a sufficient condition for satisfying the passivity of the bilateral controller including time-delay. Output energy at the master port should be less than the transmitted input energy from the slave port with time-delay, and output energy at the slave port should be less than the transmitted input energy from the master port with time-delay. For satisfying above two conditions, two passivity controllers are attached at each port of the bilateral controller. A packet reflector with wireless internet connection is used to introduce serious time-varying communication delay of teleoperators. Average amount of time-delay was about 190(msec) for round trip, and varying between 175(msec) and 275(msec). Moreover some data packet was lost during the communication due to UDP data communication. Even under the serious time-varying delay and packet loss communication condition, the proposed approach can achieve stable teleoperation in free motion and hard contact as well.

열전모듈을 이용한 냉방기의 최적 운전조건에 관한 실험적 연구 (An Experimental Study on the Optimal Operation Condition of an Air-Cooler using Thermoelectric Modules)

  • 황준;강병하
    • 설비공학논문집
    • /
    • 제18권1호
    • /
    • pp.66-72
    • /
    • 2006
  • This article presents the optimal operation of an air conditioner using thermoelectric modules. A prototype of air conditioner using four thermoelectric modules has been designed and built. The system performance with evaporative cooling for hot side of the module are studied in detail for several operating parameters, such as input power to the thermoelectric module, fans and pump. It is found that the optimal input voltage to the thermoelectric module and pump is selected for the best system performance based on the cooling capacity and the COP at a given operating condition. It is also found that both the cooling capacity and COP of a system is increased with an increase in the input power to fans. The cooling performance could be improved when the ambient temperature is increased and the relative humidity is decreased since the evaporative cooling at the hot side has been increased.

양변위 되먹임 제어기의 안정성, 제어 성능 및 설계 방법 (The Stability Conditions, Performance and Design Methodology for the Positive Position Feedback Controller)

  • 곽문규;한상보;허석
    • 한국소음진동공학회논문집
    • /
    • 제14권3호
    • /
    • pp.208-213
    • /
    • 2004
  • This paper is concerned with the theoretical estimation of the single-input single-output(SISO) positive position feedback(PPF) controller and the derivation of the stability conditions for the multi-input multi-output (MIMO) PPF controller. Although the stability condition for the SISO PPF controller was derived in the earlier works, the question regarding the performance estimation of the SISO PPF controller has never been studied theoretically. Hence, the SISO PPF controller for the single degree-of-freedom system was first investigated and then control parameters including gain, the filter frequency, and the damping factor of the PPF controller were analyzed in detail thus providing the design methodology for the SISO PPF controller. In the case of real structure. there are infinite number of natural modes so that some modes are to be controlled by a limited number of actuator and sensor. Based on the theoretical results on the SISO PPF controller, the stability condition for the multi-input multi-output PPF controller was derived when only the few number of modes are to be controlled. The control spillover problem is also discussed in detail.

단상 AC Line 호환형 대용량 전원 장치 구현 방안 (Universal Single-Phase Line Compatible High Power AC/DC Converter)

  • 김병석;강경수;노정욱
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.297-304
    • /
    • 2015
  • A conventional single-phase high-power system typically generates a large AC line input current at universal 90 VAC condition. Sometimes, this phenomenon can block the Earth Leakage Circuit Breaker (ELCB), which causes problems. Replacing power facilities is essential to ensure smooth operations. Thus, this paper proposes a method that can drive higher power than the limit of conventional power facilities. The proposed method can reduce the large AC line input current by limiting the input power of Power Factor Correction (PFC). An additional battery circuit can supplement the power deficiency. Specifically, a bidirectional converter with charging and discharging functions was adopted for the battery circuit. Finally, the validity of the proposed system could be confirmed by modal analysis and simulation, and an experiment in 2 KW condition was implemented with a prototype sample as well.

흡수식 칠러를 장착한 마이크로터빈 구동 열병합시스템의 성능 해석 (Performance Analysis of Micro-turbine CHP System with Absorption Chiller)

  • 윤린;한승동
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.540-545
    • /
    • 2007
  • The performance of microturbine CHP system equipped with an absorption chiller was analyzed by modelling of a microturbine and an absorption chiller. The microturbine having recuperator was simulated by the Brayton cycle model. The mass flow rate and available heat energy of the exhaust gas from the microtubune were simulated, and this results were utilized as input values for the generator of the absorption chiller. The absorption chiller is a single-effect air cooled type having solution heat exchanger. When heat input to the generator increased, the heat transfer rate and UA of the heat exchangers of the absorption chiller proportionally increased. Besides, the COP of the absorption chiller increased with increase of the heat input to the generator under the sufficient size of the evaporator condition. When the capacity of the CHP system increased from 30 to 60 kW, the mass flow rate of the LiBr for the absorption chiller increased by two times, and UA values for evaporator and condenser were increased by 3.9 and 3.4 times, respectively, under the same COP condition.

  • PDF

흡수식 칠러를 장착한 마이크로터빈 구동 열병합시스템의 성능 해석 (Performance Analysis of Microturbine CHP System with Absorption Chiller)

  • 윤린;한승동
    • 설비공학논문집
    • /
    • 제20권7호
    • /
    • pp.486-491
    • /
    • 2008
  • The performance of a microturbine CHP system equipped with an absorption chiller was analyzed by modeling it. The microturbine with recuperator was simulated with the Brayton cycle model. The mass flow rate and available heat energy of the exhaust gas from the microturbine were simulated. These results were utilized as input values for the generator of the absorption chiller. The absorption chiller is a single-effect air cooled type with a solution heat exchanger. The heat input into the generator was proportional to the heat transfer rate and the UA values of the heat exchangers of the absorption chiller. Furthermore, the COP of the absorption chiller increased with respect to an increase of the heat input into the generator, under the sufficient evaporator capacity condition. When the capacity of the CHP system increased from 30 to 60 kW, the mass flow rate of the LiBr for the absorption chiller doubled, and the UA values for evaporator and condenser increased by factors of x3.9 and x3.4, respectively, under the same COP condition.