• 제목/요약/키워드: Input Capacity Factor

Search Result 89, Processing Time 0.025 seconds

The Analysis of The Three Phase Rectifier (다중 3상 PWM 정류기의 해석)

  • Shin, D.H.;Youn, K.S.;Cho, J.G.;Kwon, W.H.
    • Proceedings of the KIEE Conference
    • /
    • 1995.11a
    • /
    • pp.242-245
    • /
    • 1995
  • In this paper the multiple three rectifiers for the power factor correction are proposed, analyzed and designed. The multiple three phase rectifiers draw sinusoidal ac currents from the ac voltage sources with nearly unity input power factor and operate with PWM making the control circuit simple and system cost low. Outstandingly it reduces the rated power capacity of devices and the input filter size by reducing input current ripples. Moreover design rules can be obtained from input and output current equations. With the proposed rules, input power factor and output power capacity are determined approximately. Finally these design rules are verified with computer simulations.

  • PDF

The effect on the seasonal performance of an inverter compressor with higher and lower operating range (인버터 압축기의 저속과 고속운전범위가 계절성능에 미치는 영향)

  • 박윤철;하도용;민만기
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.2
    • /
    • pp.173-179
    • /
    • 1998
  • An experimental study was conducted on the effect of compressor capacity control range of heat pump on the seasonal energy efficiency ratio with variation of the maximum and minimum compressor input frequencies. To obtain seasonal energy efficiency ratio, steady state test at the maximum, minimum and intermediate compressor speed and cyclic test at the minimum compressor speed should be conducted. Maximum input frequency was varied to 95Hz, 105Hz, and 115Hz, and the minimum input frequency was varied to 35Hz, 45Hz, and 55Hz. The seasonal energy efficiency ratio increased as the input frequency of the compressor decreased. The maximum input frequency had only slight effects on the SEER.

  • PDF

The Influence of Innovative Capacity on Regional Economic Performance (지역혁신역량이 지역경제 활성화에 미치는 영향)

  • Huh, Dongsuk
    • Journal of the Korean Geographical Society
    • /
    • v.49 no.6
    • /
    • pp.884-896
    • /
    • 2014
  • This study aims to identify the factors that contribute to the regional innovative capacity and to analyze the effects on the regional economic development including newly-established corporation and job creation. The results are as follows. First, as a result of factor analysis, the 14 variables were grouped into 3 factors, i.e. innovative input, infrastructure, and linkage. Second, the panel models were developed using the above factor scores and economic performance variables such as the number of newly-established corporation and employees. As a result, innovative capacity factors positively contributed to the newlyestablished corporation and job creation. The innovative input was the most influential factor determining the regional economic performance, followed by linkage and infrastructure. This study suggests several policy implications for the reinforcement of innovative capacity and regional competitiveness.

  • PDF

Fuzzy Control Method By Automatic Scaling Factor Tuning (자동 양자이득 조정에 의한 퍼지 제어방식)

  • 강성호;임중규;엄기환
    • Proceedings of the IEEK Conference
    • /
    • 2003.07c
    • /
    • pp.2807-2810
    • /
    • 2003
  • In this paper, we propose a fuzzy control method for improving the control performance by automatically tuning the scaling factor. The proposed method is that automatically tune the input scaling factor and the output scaling factor of fuzzy logic system through neural network. Used neural network is ADALINE (ADAptive Linear NEron) neural network with delayed input. ADALINE neural network has simple construct, superior learning capacity and small computation time. In order to verify the effectiveness of the proposed control method, we performed simulation. The results showed that the proposed control method improves considerably on the environment of the disturbance.

  • PDF

A Study on Social Carrying Capacity in Outdoor Recreation Setting: An Exploratory Analysis on the Perceived Crowding Path Model in National Park (옥외휴양공간에서의 사회적 수용능력연구: 국립공원에서의 혼잡지각의 경로모형 분석)

  • Park, Chung In
    • KIEAE Journal
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2005
  • The primary concerns of recreation plan are to provide visitors with quality of recreational experience and to protect of recreation resources. The quality of recreational experience is often defined in terms of social carrying capacity. The carrying capacity is revealed as perceived crowding. In this respects, measuring perceived crowding is useful tool of social carrying capacity determination. This study is to test the structural equation model that includes variables affecting perceived crowding. Through an on-site questionnaire survey, 467 visitors on Naejangsan national park were collected. The results of the study are follows. The encounter level on facility area is higher evaluated as crowding factor than other area in the park. It can be concluded that visitor perceived crowding when facility area situates high density use level rather than other areas expose high density use level. In the path analysis, the input variables(attitude, experience, encounter level) on the structural equation model affect significantly on perceived crowding. Especially, the attitude on the park management polocy is the most affecting factor on perceived crowding.

Experimental Investigation and Performance Test of Heavy Duty Torque Converter (중부하 토크 컨버터의 실험적 성능분석)

  • Lee, Hae-Jong;kim, Se-Hyun;Lee, Chung-Seub;Lee, Sang-Chul;Jeong, Hyo-Min;Chung, Han-Shik
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.690-695
    • /
    • 2004
  • The present study is an investigation on the characteristics of heavy load toque converter by experimental process. To get the dynamic performance, the dynamometer was used with a parameters of speed, torque, oil pressure and oil flux, etc. The torque converter was tested for various input speed, output oil pressure and input oil flow rate. All experiments were investigated in case that the speed ratio is increased. The torque ratio and capacity factor was in inverse proportion to speed. Engine revolution had a more effects at region of low speed ratio. But, the opposite phenomena were represented increase of efficiency. In result of this experiments, the characteristics of torque converter were not influenced by oil pressure and oil flux.

  • PDF

Cycloconverters with Resonant Circuits for Induction Motor Drives (기진회로를 이용한 사이크로콘버터에 의한 유도전동식 구동)

  • 김영석;조규민
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.2
    • /
    • pp.125-134
    • /
    • 1992
  • This paper presents a cycloconverter with an LC resonant circuit for an induction motor drive. The cycloconverter can keep input displacement factor at 1.0 by independently controlling real and reactive power under any load conditions. Furthermore it can keep power factor at about 1.0 since input and output current waveforms are nearly sinusoidal. Since it uses high frequency resonant circuit for commutation source, it can produce an output voltage of hundreds of hertz. Since it is also possible to make a system of high capacity using the cycloconverter, it is appropriate to drive motors with high speed and high capacity as well as general purpose motors, In this paper, we describe the operating principles of the cycloconverter and power control algorithms, and analyze its waveforms and present its characteristics. Expermental results are shown for the volts/hertz control of the induction motor and the validity of the proposed model is verified.

Boost Input type High Power Factor Resonant Power Supply for driving Magnetron Device (마그네트론 구동용 고역률 부스트 입력 방식의 공진형 전원장치)

  • Jeong, Jin-Beom;Yeon, Jae-Eui;Kim, Hee-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1078-1080
    • /
    • 2003
  • This paper proposes the boost input type resonant power supply for driving the magnetron device of the high-capacity microwave oven. Circuit topology of the proposed power supply is the boost input type resonant converter which uses the resonance between transformer leakage inductance and resonance capacitance. Proposed power supply obtains high power factor more than 98% through continuous current mode pulse width modulation. To verify the validity of the proposed power supply, operation principle in the steady state is analyzed and experimental results are presented.

  • PDF

Fabrication and Characteristics of Transformers for High Power Density SMPS (고밀도 SMPS 용 변압기의 제조와 특성)

  • Kim, Hyun-Sik;Kim, Jong-Ryung;Huh, Jung-Sub;Oh, Yong-Woo;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.04a
    • /
    • pp.7-10
    • /
    • 2002
  • We designed the flyback planar transformer, which had 8W capacity, with 70V input voltage and 8.2V output voltage for the establishment of design method and the confirmation of application possibility. The numerical value of inductance measured under the switching frequency of 120 kHz was 1650 ${\mu}H$, which was the inductance efficiency of 85~87% against theoretical value. The A.C. resistance of primary and secondary coil was 4.2 ${\Omega}$ and 0.25 ${\Omega}$ respectively. On the other hand, the quality factor for each wound numbers showed quite a high value of 158 and 75 respectively. And the Coupling Factor was 0.96~0.97 under 120 kHz switching frequency. And the shape of the output wave of the planar transformer at 70V input voltage was a stable square wave.

  • PDF

Post-earthquake capacity evaluation of R/C buildings based on pseudo-dynamic tests

  • Kang, Dae-Eon;Yi, Waon-Ho
    • Structural Engineering and Mechanics
    • /
    • v.24 no.1
    • /
    • pp.91-105
    • /
    • 2006
  • In this paper, post-earthquake capacity evaluation method of reinforced concrete buildings was studied. Substructure pseudo-dynamic test and static loading test of first story column in a four-story R/C building was carried out in order to investigate the validity of the evaluation method proposed in the Damage Assessment Guideline (JBDPA 2001). In pseudo-dynamic test, different levels of damage were induced in the specimens by pre-loading, and input levels of seismic motion, at which the specimens reached to the ultimate stage, were examined. From the experimental result, no significant difference in damage levels such as residual crack width between the specimens under static and pseudo-dynamic loading was found. It is shown that the seismic capacity reduction factors ${\eta}$ can provide a reasonable estimation of post-earthquake seismic capacity of R/C buildings suffered earthquakes.