• 제목/요약/키워드: Inlet-air temperature

검색결과 674건 처리시간 0.03초

조기이유 자돈 사육을 위한 이동식 자돈사 개발에 관한 연구 (Study on the Development of the Mobile Pig Nursery for Early Weaned Piglet)

  • 유용희;이덕수;정일병;이진우;전병수;한정대
    • 한국축산시설환경학회지
    • /
    • 제4권1호
    • /
    • pp.1-8
    • /
    • 1998
  • The objective of this study was conducted to develope a mobile pig nursery(MPN) for segregation of early weaned piglet. The units of MPN was consisted of 4 rectangle-type pens, 1 workroom, 2 doors, 3 windows, 1 air-inlet, 1 exhaust fan, and 1 cooling and heating system. Total of 40 piglet were weaned at 7 days of age. The period of the feeding test was 63 days. The results obtained are as follows: 1. The insulation thickness was 70, 70 and 50 mm of roof, floor and wall, respectively. R-value was 15.32 and 10.32 of roof and wall, respectively. 2. Exhaust fan( 30.48) was installed near back door 40cm from the bottom. When exhaust fan speeds were 15, 20, 30 and 35%, Air ventilation was required 9.75, 7.07, 1.72, 1.45 minutes of respectively. 3. Average temperature in the MPN was able to maintain 27∼28$^{\circ}C$ from 7∼28 days of age, 24∼25$^{\circ}C$ from 35∼56 days of age and 20∼21.5$^{\circ}C$ from 56∼70 days of age. 4. Average daily gain, feed intake and feed conversion were 420.6g, 761.5g, 1.81 respectively.

폐열 회수용 사판식 스팀 팽창기 설계 (Design of a Swash Plate Type of Steam Expander for Waste Heat Recovery)

  • 김현재;김현진
    • 설비공학논문집
    • /
    • 제23권5호
    • /
    • pp.313-320
    • /
    • 2011
  • For a steam Rankine cycle to recover waste heat from the exhaust gas of an Internal combustion engine, a swash plate type of expander as a power conversion unit has been designed. Numerical simulation has been carried out to estimate the performance of the designed expander. With the steam pressure and temperature of 35 bar and $300^{\circ}C$ at the expander inlet, respectively, the expander was estimated to produce the shaft power output of about 2.67 kW from the exhaust gas waste heat of 25.2 kW. The expander output increased almost linearly with the amount of exhaust gas waste heat in the range of from 5~40 kW, and the expander and Rankine cycle efficiencies showed gradual decreases in the ranges of 72.2%~69.5% and 10.8%~10.4%, respectively.

수직관(수직관)내를 흘러내리는 액막식흡수기(液膜式吸收器)의 흡수(吸收) 및 열전달(熱傳達) 특성(特性) (제(第)3보(報), 증발기(蒸發器)의 냉동능력(冷凍能力)과 흡수기(吸收器)의 난방능력(暖房能力)) (Characteristics of Absorption and Heat Transfer for Film Falling along a Vertical Inner Tube (3rd. Report, Refrigerating Capacity in Evaporator and Heating Capacity in Absorber))

  • 엄기찬;카시와기 타카오;서정윤
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.175-181
    • /
    • 1994
  • This paper deals with the correlation of absorption rate in absorber and evaporation rate in evaporator. The evaporator consists of a copper tube of 10mm dia, and 600mm long and chilled water flowing through the tube is fed by the chilled water circulator. The flowrate of LiBr-water solution in the absorber plays a significant role in determining the magnitude of the heat transfer rate from chilled water to refrigerant There exists a flowrate of solution which has a maximum value of heat transfer. It is interesting to note that the absorption rate of absorber increases with increasing the heat transfer rate of the evaporator. Also, absorption rate increases with evaportation rate, and the ratio(the former/the other) depends on the inlet temperature of LiBr-water solution in the absorber. The heating capacity in the absorber is higher than the refrigerating capacity in the evaporator.

  • PDF

스크류 열펌프 시스템의 운전제어 방안에 관한 연구 (A Study on the Operating Control of a Heat Pump System with Screw Compressors)

  • 박준택;이영수;김지영;채규정;양희정
    • 설비공학논문집
    • /
    • 제25권3호
    • /
    • pp.168-172
    • /
    • 2013
  • A preliminary performance test of a 30RT 2-stage screw heat pump was carried out in order to develop a high performance large-scale unutilized energy source heat pump system, which will be used for district heating and cooling. In this study, two issues of the system operating control were investigated. The first issue is the mode switching control from 1-stage to 2-stage. A stable 2-stage heating operation is guaranteed, only if the load-side water inlet temperature is over a certain value, where the 1-stage heating operation should be done first from a cold start. The second issue is oil level control. An oil shortage problem in the low stage compressor, which depends on the degree of suction superheat, was solved by a proper oil level control scheme.

이온 보조 반응법에 의한 친수성 처리가 충전재 특성값에 미치는 영향 (Effects of Hydrophilic Treatment by IAR Method on the Packing Characteristic Value)

  • 김진호;최충현;강병하;이재헌
    • 대한기계학회논문집B
    • /
    • 제25권4호
    • /
    • pp.554-560
    • /
    • 2001
  • Hydrophilic treatment of the packing materials in a cooling tower has been made by the ion assisted reaction (IAR) method to increase the wettability of the packing materials. The effects of hydrophilic treatment of packing materials on the performance of a cooling tower have been investigated in a wide range of operating parameters, such as water flow rate, air flow rate, and the water inlet temperature. A pilot cooling tower has been designed and built to model a counter-flow cooling tower. The results obtained indicate that the packing characteristic value with hydrophilic packing could be substantially increased by 6∼19.3% than that with conventional packing in the operating ranges considered. The correlations of the packing characteristic value as a function of water-to-air ratio are suggested for a counter-flow cooling tower with hydrophilic packing as well as with conventional packing.

빙축열시스템의 실질적인 최대 축열 가능량 예측 (Prediction of practically chargeable cold energy in an ice storage system)

  • 이대영;강병하;김민수
    • 설비공학논문집
    • /
    • 제11권1호
    • /
    • pp.133-146
    • /
    • 1999
  • The charge operation of an ice storage system has been analyzed in this paper. The thermal characteristics of major components of the ice storage system. i.e., the refrigerator and the ice storage tank are evaluated from performance tests on an existing ice storage system. Based on the measured data for thermal characteristics, a simulation is carried out for the charge operation and the effect of the refrigerator size on the system performance is investigated. The results indicate that the larger the refrigerator size for a given storage capacity, the lower the inlet temperature of the ice storage tank so that the lower the efficiency of charge operation. It is also found that there exists an optimal size of the refrigerator with which the ice storage at the end of the charge operation is maximized, but the complete charge is not possible even with the optimally sized refrigerator. This leads to the result that the design capacity of the storage tank should be larger than the required amount of cold energy for the daytime cooling considering the practically chargeable amount of cold energy during the nighttime. Where the cooling load sharing of the storage is 40%, the nominal capacity of an ice storage tank needs to be larger than the required storage amount by 30%.

  • PDF

Evaporating Heat Transfer Characteristics of R-l34a in a Horizontal Smooth Channel

  • Pamitran, A.S.;Choi, Kwang-Il;Oh, Jong-Taek;Oh, Hoo-Kyu
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권4호
    • /
    • pp.156-165
    • /
    • 2006
  • Convective boiling heat transfer coefficients were measured in a horizontal minichannel with R-l34a. The test section was made of stainless steel tube with an inner diameter of 3.0 mm and a length of 2m. It was uniformly heated by applying electric current directly to the tube. Local heat transfer coefficients were obtained for heat fluxes from 10 to $40kW/m^2$, mass fluxes from 200 to $600kgT/m^2s$, qualities up to 1.0, and the inlet saturation temperature of $10^{\circ}C$. The experimental results were mapped on Wojtan et $al.'s^(7)$ and Wang et $al.'s^(8)$ flow pattern maps. The nucleate boiling was predominant at low vapor quality whereas the convective boiling was predominant at high vapor quality. Laminar flow appeared in the flow with minichannel. The experimental results were compared with six existing two-phase heat transfer coefficient correlations. A new boiling heat transfer coefficient correlation based on the superposition model for refrigerants was developed with mean and average deviations of 10.39% and -3.66%, respectively.

무인항공기용 고분자전해질형 연료전지 시스템의 열교환기 성능 특성 연구 (Experimental Study on the Characteristics of Heat Exchanger of 1 kW PEMFC System for UAV)

  • 강상규;김병준;김한석
    • 한국수소및신에너지학회논문집
    • /
    • 제22권6호
    • /
    • pp.819-826
    • /
    • 2011
  • The proton exchange membrane fuel cell (PEMFC) is regarded as the most promising alternative power sources for unmanned aerial vehicle (UAV) due to its high energy density and silent operation. Since there are many load changes during UAV flight, thermal management is one of the important factor for the performance of PEMFC. In order to reduce the UAV weight for the stable operation of UAV, thermal management system (TMS) studied in this work does not use the fan but use the air flowing into UAV by UAV flight. In order to develop the passive type heat exchanger (HEX) for 1kW PEMFC, four types of HEXs are fabricated and their cooling performances are compared. The parametric study on the cooling performance of HEXs has performed with the variation of operating parameters such as mass flow rates and inlet temperature of air and coolant. Type 4 has the best performance in every case. This study can be helpful to achieve the optimal design of HEX for PEMFC powered UAV.

수축열조의 온도 계층화에 대한 수치해석 및 실험적 연구 (Numerical Analysis and Experiments for the Stratification of the Hot Water Storage)

  • 양윤섭;백남춘;김홍제;유제인;이준식
    • 설비공학논문집
    • /
    • 제5권3호
    • /
    • pp.187-197
    • /
    • 1993
  • In this study, the numerical analysis and experiments of the hot water storage using the thermal stratification techniques were carried out. The CPU time for a typical run of the the thermal stratification up to 900 seconds took one week for a $81{\times}31$ mesh size and 10 days for a $118{\times}31$ mesh size, respectively, for a cylindrical shape of the storage. In the initial stage, the numerical results were in favorable agreement with the experimental results, but it showed that the temperature gradients in the storage decreased gradually with time. It was also found that the increase of ${\delta}t$ decreased the convergent speed due to the intensive fluctuation of the velocity field in every iteration. The increase of numbers of grids is projected to forecast a more accurate result, but it made the computing time longer and woul slow down convergence. At the experiments of the flow visualization, it was confirmed that the thermal stratification was apparently built up due to the installation of diffuser at the lower part of the storage. Thus, the thermal performance of the storage could be improved by installing the diffusers at the inlet and outlet.

  • PDF

수중 빙 제조방식을 적용한 빙축열시스템의 축방냉 특성 실험 (Experiment of Characteristic on the Charge and Discharge of Cold in Ice Storage System Applied Ice Making Method In-Water)

  • 최인수;김재돌;윤정인
    • 설비공학논문집
    • /
    • 제14권1호
    • /
    • pp.31-37
    • /
    • 2002
  • This paper is concerned with the development of a new method for making and separating ice and saving floated ice by installing an evaporation plate at in-water within a storage tank. In a conventional harvest-type ice storage system, a tank saves ice by separating a formed ice from an installed evaporation plate, which is located above an ice storage tank as an ice storage system. A new harvest-type method shows very good heat transfer efficiency than a convectional method. It is because the evaporation panel is directly contacted with water in a storage tank. Also, at a conventional system a circulating pump, a circulating water distributor and a piping are installed, but these components are not necessary in a new method. In this study two kinds of ice storage systems are experimentally investigated to study the thermal characteristics of ice storage tanks. The results showed discharge of cold capacity of new type indicated the high values about 30~40% based on five time of drive, the temperature difference of inlet/outlet occurred the big range about $1.3^{\circ}C$. So, the new type which makes ice in water showed superiorly.