• 제목/요약/키워드: Inlet-Air Temperature

검색결과 674건 처리시간 0.023초

저온기 육용계사의 적정 환기체계 구명

  • 이덕수;나재천;최희철;송준익;이상진;김형호
    • 한국가금학회:학술대회논문집
    • /
    • 한국가금학회 2002년도 가을 학술발표논문집
    • /
    • pp.108-109
    • /
    • 2002
  • 환기체계별 내부환경 조사에서 입기관 입기 $\longrightarrow$ 강제 굴뚝배기방식이 NH$_3$ 농도 4.2ppm으로 윈치창 입기방식보다 유리하였고, 사육 성적에서는 입기관 입기 $\longrightarrow$ 강제 굴뚝배기방식이 일당 증체량 45.6g, 사료요구율 1.71, 수당 연료비 35.4원으로 다른 환기방식보다 우수하였으며, 입기관 길이별 풍속은 4m 가 1m 입기관보다 공기가 고루 퍼져가는 경향이었고 지점별 계사내 온도는 입기관 입기방식이 5.9 ~ 7.7$^{\circ}C$(평균 7.$0^{\circ}C$) 높아 연료절감 효과가 기대되었다.

  • PDF

A Study on the Effects of System Pressure on Heat and Mass Transfer Rates of an Air Cooler

  • Jung, Hyung-Ho
    • Journal of Mechanical Science and Technology
    • /
    • 제16권5호
    • /
    • pp.696-702
    • /
    • 2002
  • In the present paper, the effects of inlet pressure on the heat and mass transfer rates of an air cooler are numerically predicted by a local analysis method. The pressures of the moist air vary from 2 to 4 bars. The psychrometric properties such as dew point temperature, relative humidity and humidity ratio are employed to treat the condensing water vapor in the moist air when the surface temperatures are dropped below the dew point. The effects of the inlet pressures on the heat transfer rate, the dew point temperature, the rate of condensed water, the outlet temperature of air and cooling water are calculated. The condensation process of water vapor is discussed in detail. The results of present calculations are compared with the test data and shows good agreements.

태양열을 이용한 공기가열 집열기의 부력효과 해석 연구 (Study on Analysis of Buoyancy Effect in Air-heating Collector using Solar Heat)

  • 양영준
    • 한국산업융합학회 논문집
    • /
    • 제24권4_2호
    • /
    • pp.467-474
    • /
    • 2021
  • The renewable energy is known as eco-friendly energy to reduce the use of fossil fuel and decrease the environmental pollution due to exhaust gas. Targets of solar collector in domestic are usually acquisitions of hot water and hot air. System of air-heating collector is one of the technologies for obtaining hot air in cases of especially heating room and drying agricultural product. The purpose of this study is to investigate the characteristics of thermal flow such as relative pressure, velocity, outlet temperature and buoyancy effect in air-heating collector using solar heat. The flow field of air-heating collector was simulated using ANSYS-CFX program and the behaviour of hot air was evaluated with SST turbulence model. As the results, The streamline in air-heating collector showed several circular shapes in case of condition of buoyancy. Temperature difference in cross section of outlet of air-heating collector did not almost show in cases of buoyancy and small inlet velocity. Furthermore merit of air-heating collector was not observed in cases of inlet velocities. Even though it was useful to select condition of buoyancy for obtaining high temperature, however, it was confirmed that the trade off between high temperature of room and rapid injection of hot air to room could be needed through this numerical analysis.

흡기조건의 변화에 따른 공기조화용 회전재생기에 관한 실험적 연구 (An Experimental Study on the Rotary Regenerator for Air Conditioning according to Variable Inlet Conditions)

  • 이태우;조진호;서정일
    • 대한기계학회논문집
    • /
    • 제14권2호
    • /
    • pp.422-429
    • /
    • 1990
  • The experimental study investigates two aspects of counterflow sensible heat regenerator operation. First, it examines the regenerator performance in periodic steady state operation with spatially nonuniform inlet temperature in one of the fluid stream. Second, the study examines the transient response of a regenerator to a step change in the inlet temperature of one of the fluid streams. The effect of transient inlet temperatures is analyzed in terms of the response of the outlet fluid temperatures to a step change in temperature of one of the inlet fluid streams. The effect of temperature nonuniformities is analyzed in terms of the change of temperature nonuniformities is analyzed in terms of the change in steady state effectiveness due to a circumferential temperature distribution in one of the inlet fluid streams. an experimental analysis has been conducted using a counterflow, parallel passage, and rotary regenerator made from polyethylene film. Efficiencies follow similar trends with increasing matrix to fluid capacity rate ratio for the balanced and symmetric regenerator with nonuniform inlet temperature.

램제트 성능에 미치는 흡입 공기 온도에 대한 고찰 (Review of the Inlet Air Temperature Effect on the Ramjet Performance Efficiency)

  • 이태호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2007년도 제29회 추계학술대회논문집
    • /
    • pp.271-274
    • /
    • 2007
  • 고체 램제트 추진기관에서도 일반 로켓 추진기관에서와 같이 Isp 즉 추력을 증대시키기 위하여 고체 입자들을 연로에 함유시킨다. 이러한 고체입자가 포함된 연료들은 매우 짧은 연소실 체류시간 때문에 연소 효율의 증대가 필수적이며 흡입공기 온도가 중요한 역할을 한다. 이 흡입공기 온도가 램제트 성능에 미치는 영향을 조사하였다. 연소실 흡입공기 온도에 영향을 미치는 인자는 자유 유동장 즉 대기 온도와 비행 마하수이다. 램제트 연소실에서의 유속 또한 중요한 역할을 함으로 유속 전 영역 즉 정체상태부터 음속까지에 대하여 조사하였다.

  • PDF

냉복도 밀폐시스템을 적용한 서버실의 실내온도조건 (Server Room Temperature Condition in Data Center with Cold Aisle Containment System)

  • 정용호;장현재;서장후
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.79-84
    • /
    • 2013
  • In this study, a cold aisle containment system was proposed among various strategies to reduce the energy waste by recirculation air from the hot aisle. To verify the effectiveness of the cold aisle containment system, a test bed which is similar to an actually existing server room was set up in the Internet Data Center(IDC) building. Comparative experiments, conventional open type cooling system and cold aisle containment system were carried out under actual conditions. The result revealed that the range of inlet temperature of the server system was $20{\sim}25^{\circ}C$ in an existing cooling system and the range of inlet temperature dropped below $20^{\circ}C$ by the cold aisle containment system. After all, cold aisle containment system was proved to be the solution for energy saving cooling system.

고분자 제습로터의 저온재생 성능시험 (Performance Test of Low Temperature Regeneration Polymeric Desiccant Rotor)

  • 이진교;이대영;오명도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.629-632
    • /
    • 2009
  • The polymeric desiccant rotor is made from the super absorbent polymer by ion modification. The moisture sorption capacity of the super desiccant polymer(SDP) is 4 to 5 times larger than those of common desiccant meterials such as silica gel or zeolite. It is also known that SDP can be regenerated even at the relatively low temperature. To fabricate the desiccant rotor, firstly the SDP was laminated by coating the SDP on polyethylene sheet. Then corrugated and rolled up into a rotor. The diameter, the depth, the dimensions of the corrugated channel, etc. were pre-determined from numerical simulation on the heat and mass transfer in the desiccant rotor. The dehumidification performance was tested in a climate chamber. The relevant tests were carried out at the process air inlet temperature of $32^{\circ}C$, the regeneration air inlet temperature of $60^{\circ}C$ and the inlet dew-point temperature of both the process air and the regeneration air of $18.5^{\circ}C$, when the rotation period is long, the moisture sorption is not effective. In the desiccant rotor developed in this study, the optimum rotation period is found about 350s at the regeneration temperature of $60^{\circ}C$. It was found from further experiments that the optimum rotation tends to decreases as the regeneration temperature increases. Meanwhile, the outlet temperature of the process air deceases monotonically as the rotation period increases.

  • PDF

공기 온습도가 공조용 가습 소자의 가습 성능에 미치는 영향에 대한 실험 연구 (An Experimental Study on the Effect of Air Temperature and Humidity on Humidification Performance of the Humidifying Element Used for Air Conditioning)

  • 김내현
    • 한국산학기술학회논문지
    • /
    • 제20권2호
    • /
    • pp.732-740
    • /
    • 2019
  • 가습 소자를 이용한 증발식 가습은 건물이나 데이터 센터의 공조에 널리 사용되고 있다. 가습 소자의 성능은 가습 효율로 나타내는데 이 효율은 공기의 온습도나 물 온도에 무관하게 사용되고 있다. 본 연구에서는 데이터 센터와 건물 공조의 두 공기 조건에 대하여 셀룰로오스/PET, Glasdek의 두 소자를 사용하여 전벙 풍속과 물 온도를 변화시키며 일련의 실험을 수행하였다. 실험 결과 측정된 가습 효율은 공기 조건과 물 온도에 따라 다르게 나타났다. 심지어 건물 조건에서는 소자의 입구부에서 감습이 나타나기도 하였는데 그 이유는 공급수 온도가 입구 공기의 노점온도보다 낮았기 때문이었다. 건물 조건에서는 공급수 온도와 공기의 노점 온도 차이가 증가할수록 가습 효율은 감소하였다. 이로부터 가습 효율 모델을 적절히 세우려면 길이 방향으로 수분 전달량이 변화하는 입구 영역에 대한 해석이 중요하다고 판단된다. 셀룰로오스/PET 소자에 대하여 성능 해석을 수행한 결과 Sherwood 수는 적절히 예측하였으나 마찰 손실은 과대 예측하였다. 이는 해석시 채널 형상을 단순한 삼각형으로 가정하고 소자 표면에 형성된 액막의 영향을 무시한 때문으로 판단된다.

유동방향의 열전도가 전열면의 성능에 미치는 영향 (Effects of longitudinal conduction on the performance of heat transfer surfaces)

  • 박병규;홍택;박상희
    • 설비공학논문집
    • /
    • 제11권5호
    • /
    • pp.561-569
    • /
    • 1999
  • The effects of longitudinal heat conduction on the performance of heat transfer surfaces are investigated by using a single-blow method. In the transient testing method for determining the heat transfer characteristics, exponential inlet temperature variations are made by using screen-mesh heater with small time constant and low frontal velocities of the test section, and the experimentally determined inlet temperature profile is used as the inlet fluid temperature condition. The effects of longitudinal heat conduction are negligible only if $\gamma^\act<0.05\;and \;N_{tu}\le3$ and should be considered if $N_{tu}\le3$ The test results ate compared with the existing theoretical and experimental data and the validity of this technique is confirmed by the good agreement.

  • PDF

엔진구동 지열 열펌프의 성능 분석(III) - 대체냉매를 이용한 증기압축식 열펌프의 운전특성 - (Performance Analysis of an Earth Coupled Heat Pump System Operated by an Engine(III) - Operating Characteristics of a Vapour Compression type Heat Pump Using Alternate Refrigerant -)

  • 김영복;이승규;김성태;송대빈;강호철
    • Journal of Biosystems Engineering
    • /
    • 제24권6호
    • /
    • pp.513-522
    • /
    • 1999
  • This study was performed to get the optimal operating conditions of an water-air compact heat pump system using R-134a. The experiments was done for three elvels of the air mass flow rate and the compressor driving speed during air-heating process. The temperature of the air at the condenser inlet and outlet was 17~23$^{\circ}C$, 36~44$^{\circ}C$, respectively. The average temperature of the refrigerant at the evaporator and condenser was 1$0^{\circ}C$, 6$0^{\circ}C$, respectively. The temperature of the refrigerant was not depending on the air mass flow rate and the compressor driving speed. The pressure of the refrigerant at the condenser inlet and outlet was ranged of 10~18.5kg/$\textrm{cm}^2$ and that at the evaporator was ranged of 3.1~3.3kg/$\textrm{cm}^2$. The pressure drop at the condenser and evaporator was about 1.5, 1.2 kg/$\textrm{cm}^2$, respectively. The performance of coefficient for air heating was about 3.3~4.0.

  • PDF