• Title/Summary/Keyword: Inlet pipe

Search Result 253, Processing Time 0.018 seconds

Condensing Heat Transfer Charactristics of R-22 Alternative Refrigerants on Water Sources Heat Pump (수열원 펌프에서의 R-22 대체냉매의 응축열전달특성에 관한 연구)

  • 김기수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.3
    • /
    • pp.285-293
    • /
    • 1998
  • This paper presents an experimental study on condensing heat transfer characteristics of R-22 alternative refrigerants, R-290 and R-410a on water sources heat pump. The apparatus mainly consisted of vapor pump condenser used to the test section evaporator manual expansion valve and measuring device. Test section constructed a smoothed tube of 10.07 mm ID and 12.7mm OD with a total length 6,300 mm was horizontal double pipe counterflow condenser. The refrigerants R-22, R-290 and R-410a were cooled by a coolant circulated in a surrounding annulus. Experimental range of mass velocities was changed from about 100 to 300 kg/($m^2$.s) and inlet quality 1.0 The credibility of experimental apparatus was 6 percent between heating capacity and cooling capacity added to compressor shaft power. The condensing heat transfer coefficients were increased with increasing mass velocity. However in case of R-290 they were more increasing than those of R-410a and R-22 Comparing the heat transfer coefficient between the experimental data and other's data the Cavallini-Zecchin's data was revealed to more similar prediction of author's experimental results on the average heat transfer coefficients.

  • PDF

An Experimental Study on dte Performance of Plasma-DeNOx Catalyst widt Supplying Hydrocarbon Reductant (탄화수소 환원제 공급에 따른 플라즈마-DeNOx 촉매의 성능에 관한 실험적 연구)

  • Hur, Dong-Han;Min, Kyoung-Doug
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.93-99
    • /
    • 2008
  • To improve the performance of plasma-DeNOx catalyst, a research on active system was performed experimentally. Two hydrocarbons, propane and diesel, were used as a reductant in this study. First, using propane, basic performances of plasma-DeNOx catalyst such as the effects of plasma and C/N ratio were measured at the various engine operating conditions. NOx conversion of catalyst was improved as plasma power or C/N ratio was increased. Next, diesel was injected in the exhaust gas flow as a reductant. The first test using diesel as a reductant is spray visualization in a high temperature flow and spray images were utilized for analysis of posterior test results. To evaluate the effect of an injection direction, it was compared with 6 installation methods of diesel injector due to THC concentrations at the inlet of plasma. From the results, injector was installed toward downstream direction below the pipe. Then, basic performances of plasma-DeNOx catalyst with various injection quantities were measured. As an injection quantity was increased, $NO_2$ conversion of plasma reactor was increased but NOx conversion of catalyst was nearly zero. This was because NOx conversion of catalyst had slowed as time goes by due to black particles which had been adhered to the catalyst.

Study on the Performance Improvement of the Aftermarket Automotive Muffler (비순정품 자동차 머플러의 성능개선)

  • Lee, Sung-Won;Choi, Doo-Seuk;Park, Sung-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.10
    • /
    • pp.2602-2608
    • /
    • 2009
  • Aftermarket muffler has been developed mainly by personal experience and trial-and error and has not been properly simulated or evaluated its performance. One of the aftermarket muffler problems is that the aftermarket muffler has quite high pressure-drop across the passage. To reduce the pressure-drop, various simulation and test has been performed for various muffler models. As a result, the muffler that has superior pressure-drop and vibration characteristics compared to the previous muffler has been developed. Developed aftermarket muffler has a structure that avoids confined space causing vibration due to exhaust pressure pulsation and bisects an inlet pipe from the engine.

Heat Transfer Characteristics of R-407C During Condensing Inside Horizontal Smooth and Micro-Fin Tubes (수평 평활관 및 전열촉진관내 대체 냉매 R-407C의 응축 열전달 특성에 관한 연구)

  • Roh, Geonsang;Oh, Hookyu
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.2
    • /
    • pp.210-217
    • /
    • 1999
  • This paper reports the experimental results on heat transfer characteristics of R-22 and R-407C(HFC-32/125/134a 23/25/52 wt%) condensing inside horizontal smooth and finned tubes. The test condensers used In the study are double pipe heat exchangers of 7.5 mm ID, 9.5 mm OD smooth tube, and 60 finned micro-fin tube with 8.53 mm ID, 9.53 mm OD. Each of these tubes was 4 000 mm long tubes connected with an U-bend. These U type two-path test tubes are divided In 8 local test sections for the identification of the local condensing heat transfer characterisitcs and pressure drop, U-bend effects on condensing flows. Inlet quality is maintained 1.0, and refrigerant mass velocity is varied from 102.0 to $301.0kg/m^2{\cdot}s$. From the results, it was found that the pressure drop of the R-407C Increased, and heat transfer coefficient decreased compared to those of R-22. In comparison condensing heat transfer characteristics of micro-fm tube with those of smooth tube, increasing of condensing heat transfer coefficient was found outstanding compared to the increasing ratio of pressure drop. Furthermore, pressure drop In U-bend showed at most a 30 % compared to the total pressure drop in the test section.

Removal of Heavy Metals Through Conventional Water Treatment Processes (정수처리 과정에서의 중금속제거에 관한 연구)

  • 김중구;고영송;남상호
    • Journal of Environmental Health Sciences
    • /
    • v.20 no.4
    • /
    • pp.36-44
    • /
    • 1994
  • A study was carried out in order to investigate the removal efficiencies and removal characteristics of heaw metals such as Pb, Cd, Cr, Cu in raw water by one of conventional water treatment processes. The coagulants used in this study were Alum and PAC. Three kinds of water samples were provided: kaolin water, kaolin water mixed with humic acid and raw water from Han River mixed with suspended matter deposited on raw water inlet pipe. Heaw metals were added to the water samples with their respective turbidity, and jar tests were performed. In the results from heaw metal removal studies, lead might be adsorbed or exchanged on the particle surface (SS) rather than react with organic matter added. Cadmium was affected on the dissolved organic matter. Chromium was affected by the both dissolved organic matter and SS concentration, and the restabilization and the enmeshment appeared at moderate (50~80 NTU) and high (100 NTU) turbidity as defined in this experimenL The removal efficiency of copper was relatively little affected by the dissolved organic matter but by SS concentration in comparison with other heavy metals. In these studies as to the raw water turbidities and concentration of heaw metals, it is proved out that the removal efficiency on heaw metals in both cases of PAC and Alum as coagulants was not significantly different.

  • PDF

Flow Network Analysis for the Flow Control of a Main Cooling Water System in the HANARO Fuel Test Loop (하나로 핵연료 시험 루프 주냉각수 계통의 유량 제어에 대한 유동 해석)

  • Park, Young-Chul;Lee, Yong-Sub;Chi, Dae-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.5
    • /
    • pp.7-12
    • /
    • 2009
  • A nuclear fuel test loop(after below, FTL) is installed in the IRI of an irradiation hole in HANARO for testing the neutron irradiation characteristics and thermo hydraulic characteristics of a fuel loaded in a light water power reactor or a heavy water power reactor. There is an in-pile section(IPS) and an out-pile section(OPS) in this test loop. When HANARO is operated normally, the fuel loaded into the IPS has a nuclear reaction heat generated by a neutron irradiation. To remove the generated heat and to maintain the operation conditions of the test fuel, a main cooling water system(MCWS) is installed in the OPS of the FTL. The MCWS is composed of a main cooler, a pressurizer, two circulation pumps, a main heater, an interconnection pipe line and instruments. The interconnection pipeline is a closed loop which is connected to an inlet and an outlet of the IPS respectively. The MCWS is under a cold function test during a start-up period. This paper describes the system flow network analysis results of the flow control of a main cooling water system in the HANARO fuel test loop. It was confirmed through the results that the flow was met the system design requirements.

Large-Scale Turbulent Vortical Structure Inside a Sudden Expansion Cylinder Chamber (급 확대부를 갖는 실린더 챔버 내부 유동의 큰 척도 난류 보텍스 구조에 관한 연구)

  • Seong, Hyeong-Jin;Go, Sang-Cheol
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.7
    • /
    • pp.905-914
    • /
    • 2001
  • A large eddy simulation(LES) is performed for turbulent flow around a bluff body inside a sudden expansion cylinder chamber, a configuration which resembles a premixed gas turbine combustor. To promote turbulent mixing and to accommodate flame stability, a flame holder is installed inside the combustion chamber. The Smagorinsky model is employed and the calculated Reynolds number is 5,000 based on the bulk velocity and the diameter of the inlet pipe. The simulation code is constructed by using a general coordinate system based on the physical contravariant velocity components. The predicted turbulent statistics are evaluated by comparing them with the laser-doppler velocimetry (LDV) measurement data. The agreement of LES with the experimental data is shown to be satisfactory. Emphasis is placed on the time-dependent evolutions of turbulent vortical structure behind the flame holder. The numerical flow visualizations depict the behavior of large-scale vortices. The turbulent mixing process behind the flame holder is analyzed by visualizing the sectional views of vortical structure.

A study on the free surface vortex in the pipe system (배관내 자유수면에서 와류현상에 대한 연구)

  • 오율권;장완호;이종원;김상녕
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.11
    • /
    • pp.2126-2135
    • /
    • 1992
  • In order to prevent the decay heat removal system from failure due to air entrainment or free surface vortex in the piping system, a set of simulating experiments for the midloop operation of nuclear power plant was performed. Through these experiments, a relation between the dimensionless numbers, such as submergence H/d, froude number, reynolds number, was found. However, the effect of reynolds number was negligible for the operation conditions of Nuclear power plant. It was also found that the perturbation of the system by the disturbance such as pump start, valve operation, etc., has a strong effect on the free surface vortex. Furthermore, from a view point of reactor safery, a modified inlet device of reducer type is strongly recommendable for the prevention of air entrainment.

Evaluation of water treatment characteristics at the improved circle secondary settling basin (개량 고속원형침전지의 수처리 특성 평가)

  • Jang, Honggyu;Cho, Youngman;Kim, Changwon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.28 no.5
    • /
    • pp.609-614
    • /
    • 2014
  • Researcher of this study improved conventional circle secondary settling basin, through the way such as extend of inlet pipe length, introduction of device for inducting uniforming of flow, keeping of height of sludge interface. Also, we compared conventional circle settling basin to improved circle settling basin the water treatment efficiency. Result of research, when SVI is average 117, improvement rate of SS and BOD were 51.0%, 37.0% approximately compared to conventional settling basin. And when SVI is average 178, improvement rate of SS and BOD were 22.7%, 36.0% approximately. Also when SVI is average 196, improvement rate of SS and BOD were 24.7%, 30.3% approximately. When it's winter, improvement rate of SS, BOD, COD, TN and TP were 20.6%, 17.9%, 13.9%, 13.5%, 12.4% approximately. Therefore, we can be the judge, this improved settling basin can be used as the final settling basin in the waste water treatment plant.

A Case Study for Reasonable Emission Regulation of Odor Exhaust Stack (악취 배출구의 합리적인 배출규제를 위한 사례연구)

  • Park, Jeong-Ho;Lee, Hyung-Chun
    • Journal of Environmental Science International
    • /
    • v.25 no.1
    • /
    • pp.155-161
    • /
    • 2016
  • In this study, field experiment, odor simulator, and dispersion modeling were used to evaluate the odor impact from J sewage sludge treatment facility. The height and flow rate of exhaust stack at this facility were 22.3 m and $100Nm^3/min$. The mean odor concentrations of the wet scrubber inlet and exhaust stack were $267{\pm}160$ and $93{\pm}44OU/m^3$, respectively. The odor removal efficiency of wet scrubber showed 65%. The odor simulator is used for the regulated standard calculation of the exhaust pipe(stack). Resulting odor emission rate(OER) by odor simulator was $2.4{\times}10^6(24,000OU/m^3)$. The forecasting result by Screen3 modeling showed that odor exhaust concentration up to $30,000OU/m^3$ was't exceeded maximum allowable emission level on site boundary($15OU/m^3$).