• Title/Summary/Keyword: Inlet and outlet angle

Search Result 84, Processing Time 0.022 seconds

Wall shear stress and Pressure Distributions of Developing Turbulent Oscillatory Flows in a Square sectional Curved Duct (곡관덕트에서 난류진동유동의 전단응력분포와 압력분포)

  • Lee, H.G.;Son, H.C.;Lee, H.N.;Park, G.M.
    • Proceedings of the KSME Conference
    • /
    • 2001.06e
    • /
    • pp.380-385
    • /
    • 2001
  • In the present study, flow characteristics of turbulent oscillatory flow in a square-sectional $180^{\circ}$ curved duct are investigated experimentally. In order to measure wall shear stress and pressure distributions, experimental studies for air flow are conducted in a square-sectional $180^{\circ}$ curved duct by using the LDV system with the data acquisition and the processing system. The wall shear stress measuring point bend angle of the $150^{\circ}$ and pressure distribution of the inlet (${\phi}=0^{\circ}$) to the outlet (${\phi}=180^{\circ}$) at $10^{\circ}$ intervals of the duct. The results obtained from the experimentation are summarized as follows: A wall shear stress value in an inner wall is larger than that in an outer wall, except for the phase angle (${\omega}t/{\pi}/6$) of 3, because of the intensity of secondary flow. The pressure distributions are the largest in accelerating and decelerating regions at the bend angle(${\phi}$) of $90^{\circ}$ and pressure difference of inner and outer walls is the largest before and after the ${\phi}=90^{\circ}$.

  • PDF

Wall Shear Stress and Pressure Distributions of Developing Turbulent Oscillatory Flows in an Oscillator Connected to Curved Duct (가진 펌프에 연결된 곡관덕트에서 난류진동유동의 전단응력분포와 압력분포)

  • Sohn, Hyun-Chull;Lee, Hong-Gu;Lee, Haeng-Nam;Park, Gil-Moon
    • The KSFM Journal of Fluid Machinery
    • /
    • v.4 no.4 s.13
    • /
    • pp.37-42
    • /
    • 2001
  • In the present study, flow characteristics of turbulent oscillatory flow in an oscillator connected to square-sectional $180^{\circ}$ curved duct are investigated experimentally. In order to investigate wall shear stress and pressure distributions, the experimental studies for air flows we conducted in a square-sectional $180^{\circ}$ curved duct by using the LDV system with the data acquisitions and the processing system. The wall shear stress at bend angle of the $150^{\circ}$ and pressure distribution of the inlet (${\phi}=0^{\circ}$) to the outlet (${\phi}=180^{\circ}$) by $10^{\circ}$ intervals of the duct are measured. The results obtained from the experiment are summarized as follows : wall shear stress values in the inner wall we larger than those in an outer wall, except for the phase angle (${\omega}t/{\pi}/6$) of 3, because of the intensity of secondary flow. The pressure distributions are the largest in accelerating and decelerating regions at the bend angle(${\phi}$) of $90^{\circ}$ and pressure difference of inner and outer walls is the largest before and after the ${\phi}=90^{\circ}$.

  • PDF

A Study for Numerical Analysis of Flow Variation on Low Pressure Fuel Pump Fluid using Excavator Engine (굴삭기 엔진용 저압연료펌프 유체의 유동변화에 대한 수치해석적 연구)

  • Lee, IL Kwon;Kim, Seung Chul
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.47-53
    • /
    • 2015
  • This paper is to study applying for numerical analysis method for flow field, velocity and pressure of fuel on the low pressure pump using excavator. The pressure distribution of fuel pump certified the linear variation according to rotation angle of rotor. Especially, it knew the fact that the pressure in rotation angle $40^{\circ}$ appeared high outlet and low inlet of fuel pump. Also, this range angle can seek the fact that the leakage flow and velocity are the most increasing. And the more rotor rotation of fuel pump, the more mean outlet flow rate increased in linear. Whenever the gap size decrease with rotor and housing, the discharge flow rate could seek the approaching 0.0712kg/s that consider with theory discharge flow rate calculated from displacement between rotor gear and idle gear.

Numerical Analysis of Flow Fields for Optimum Design of Vehicle Vacuum Pump with Multivanes (자동차용 진공펌프 멀티 베인의 최적 설계를 위한 유동장 수치해석)

  • Lim, Tae-Eun;Lee, Kye-Bock
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.9
    • /
    • pp.883-890
    • /
    • 2011
  • A numerical study was conducted to determine the optimal design for a vehicle vacuum pump. The degree of vacuum was examined for different design factors such as the angle of vanes, number of vanes, angle and position of the pump inlet-outlet pipe, and angular rotational speed of vanes. The results show that there is a little difference in the degree of vacuum when the angle of vanes are changed, but an angular change in the outlet pipe reduces the pump loss. As the rotational speed is increased, the mass flow rate increases, but a high rotational speed does not result in the maximum degree of vacuum. In addition, when the number of vanes is increased, the scattering range of mass flow rate decreases and pressure drop is abated.

Flow Characteristics for the Variation of Total Angles in Open Channel Bends (개수로 만곡부에서의 중심각 변화에 따른 흐름특성)

  • Lee, Jong Tae;Yoon, Sei Eui
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.7 no.3
    • /
    • pp.195-202
    • /
    • 1987
  • The flow characteristics in the shallow open channel bends are investigated, whose total angles were 30, 60, 90, 120, 150 and 180 in degree, and whose bed frictions were relatively rough(C=30) and smooth(C=60), respectively. The terms analyzed in this study are the water surface profile, the distribution of velocity and the flow direction, relating to the various total angles in the bends. The maximum depth in the bends could be found at the outside section of the location of $15^{\circ}$ local angle from the bend inlet, having no relation to the total angle and bed friction. It is supposed that the path of maximum velocities is especially influenced by the bottom friction when the total angles are bigger than 150 in degree, approximately. The ratio of the superelevation to the velocity head seems to increase as the total angle of the bends increases. The flow direction is skewed to the inner side at the bend inlet, and skewed to the outside at the bend outlet, regardless of their total angles.

  • PDF

Investigation of Flow and Heat Transfer Characteristics of Plate Heat Exchanger Taking into Account Entrance Effects and Variation in Corrugation Height (입구영향 및 주름높이의 변화를 고려한 판형열교환기의 유동 및 열전달 특성)

  • Moh, Jeong-Hah
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.11
    • /
    • pp.965-973
    • /
    • 2010
  • Numerical analysis has been carried out to investigate the heat transfer characteristics of a plate heat exchanger. The multi-cell models with inlet part and outlet part are used for performing numerical simulation. The plate heat exchanger is characterized by chevron angle of $15^{\circ}$, corrugation pitch of 24mm and corrugation height 6~12mm. The length of the inlet-part considered in the analysis ranges from 24.8 to 124mm and Reynolds numbers range from 1,000 to 10,000. The correlations such as friction factor and Colburn factor are compared with previous experimental data. The results can be utilized for designing the plate heat exchanger.

A Numerical Analysis on High Pressure Control Valve for Offshore (해양구조물용 고압 컨트롤 밸브 수치해석)

  • Yi, Chung-Seub;Jang, Sung-Cheol;Jeong, Hwi-Won;Nam, Tae-Hee
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.1195-1200
    • /
    • 2008
  • This study have goal with conceptual design for Offshore Structures of high pressure control valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the Offshore Structures high pressure control valve. Numerical simulation using CFD(Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the glycerin($C_3H_8O_3$). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated until increasing 1bar to 10bar. CFD analysis used STAR-CCM+ which is commercial code and Governing equations were calculated by moving mesh which is rotated 90 degrees when ball valve operated opening and closing in 1 degree interval. The result shows change of mass flow rate according to opening and closing angle of valve. Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. Relation with flow and flow coefficient can not be proportional according to inlet pressure when compare with mass flow rate. Because flow coefficient have influence in flow and pressure difference. Namely, flow can be change even if it has same Cv value. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

  • PDF

A Fundamental Study on Offshore Structures of high pressure control valve (해양구조물용 고압 컨트롤 밸브에 대한 기초 연구)

  • Lee, Chi-Woo;Jang, Sung-Cheol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.19 no.6
    • /
    • pp.883-888
    • /
    • 2010
  • This study have goal with conceptual design for Offshore Structures of high pressure control valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the Offshore Structures high pressure control valve. Numerical simulation using CFD (Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the glycerin (C3H8O3). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated until increasing 1bar to 10bar. CFD analysis used STAR-CCM+ which is commercial code and Governing equations were calculated by moving mesh which is rotated 90 degrees when ball valve operated opening and closing in 1 degree interval. The result shows change of mass flow rate according to opening and closing angle of valve, Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. Relation with flow and flow coefficient can not be proportional according to inlet pressure when compare with mass flow rate. Because flow coefficient have influence in flow and pressure difference. Namely, flow can be change even if it has same Cv value. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

A Numerical Analysis on Flow and Strength of Ball Valve for petrochemistry (석유화학용 Ball Valve 유동 및 강도 수치해석)

  • Yi, Chung-Seub;Jeong, Hwi-Won;Jang, Sung-Cheol;Nam, Tae-Hee;Park, Jung-Ho;Yun, So-Nam
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.357-362
    • /
    • 2008
  • This study have goal with reverse engineering for petrochemistry of high pressure ball valve for localization. Ball valve for development accomplished with flow analysis based on provision of ANSI B16.34, ANSI B16.10, ANSI B16.25 In order to localize the petrochemistry high pressure control valve. Numerical simulation using CFD(Computational Fluid Dynamic) in order to predict a mass flow rate and a flow coefficient form flow dynamic point of view. The working fluid assumed the water($H_2O$). The valve inlet and outlet setup a pressure boundary condition. The outlet pressure was fixed by atmospheric pressure and calculated inlet velocity 5m/s. CFD solver used STAR-CCM+ which is commercial code. The result shows change of mass flow rate according to opening and closing angle of valve. Flow decrease observed open valve that equal percentage flow paten which is general inclination of ball valve. The structural analysis used ANSYS which is a commercial code. Stress analysis result of internal pressure in valve showed lower than yield strength. This is expect to need more detail design and verification for stem and seat structure.

  • PDF

Investigation Into the Drilling Characteristics of Carbon Fiber Reinforced Plastic (CFRP) with Variation of the Stacking Sequence Angle (탄소섬유강화플라스틱(CFRP)의 적층 배향각에 따른 드릴링 가공 특성 고찰)

  • Kim, Tae-Young;Kim, Ho-Seok;Shin, Hyung-Gon
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.3
    • /
    • pp.250-258
    • /
    • 2014
  • Due to recent industrial growth and development, there has been a high demand for light and highly durable materials. Therefore, a variety of new materials has been developed. These new materials include carbon fiber reinforced plastic (CFRP or CRP), which is a wear-, fatigue-, heat-, and corrosion-resistant material. Because of its advantageous properties, CFRP is widely used in diverse fields including sporting goods, electronic parts, and medical supplies, as well as aerospace, automobile, and ship materials. However, this new material has several problems, such as delamination around the inlet and outlet holes at drilling, fiber separation, and tearing on the drilled surface. Moreover, drill chips having a fine particulate shape are harmful to the work environment and engineers' health. In fact, they deeply penetrate into machine tools, causing the reduction of lifespan and performance degradation. In this study, CFRP woven and unidirectional prepregs were formed at $45^{\circ}$ and $90^{\circ}$, respectively, in terms of orientation angle. Using a high-speed steel drill and a TiAIN-coated drill, the two materials were tested in three categories: cutting force with respect to RPM and feed speed; shape changes around the input and outlet holes; and the shape of drill chips.