• Title/Summary/Keyword: Inlet Temperature

Search Result 1,510, Processing Time 0.023 seconds

Experimental Study on Combustion Characteristics of a Swirl-stabilized Conical Burner (스월 예혼합 버너의 연소 특성에 관한 실험적 연구)

  • Kim, Gu;Cho, Ju Hyeong;Lee, Dong Suk;Kim, Han Seok;Sohn, Chae Hoon;Lee, Sang Min;Kim, Min Kuk;Ahn, Kook Young
    • Journal of the Korean Society of Combustion
    • /
    • v.19 no.3
    • /
    • pp.1-7
    • /
    • 2014
  • Experimental study has been carried out to understand combustion characteristics of a swirl-stabilized premixed gas turbine combustor for power generation. $NO_x$ and CO emissions, extinction limit, pressure loss, and temperature distribution were measured for various operating conditions. Results show that, with increasing inlet air temperature, $NO_x$ is increased due to a higher adiabatic flame temperature while CO is increased or decreased for low or high A/F ratio regime, respectively. depending on the flame location. With decreasing load from the design condition, $NO_x$ is decreased as thermal load is reduced. With further decreasing load, however, $NO_x$ is increased due to a longer residence time. CO is decreased and then increased with decreasing load. Flame extinction limit is extended with increasing inlet air temperature as the recirculation strength is enhanced.

Investigation of Performance Characteristics in a Welded Plate Heat Exchanger according to Mass flow rate and Temperature (용접식 판형열교환기에서 작동유체의 유량과 온도변화에 따른 성능특성 고찰)

  • Ham, Jeonggyun;Kim, Min-Jun;An, Sungkook;Cho, Honghyun
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.14 no.4
    • /
    • pp.20-26
    • /
    • 2018
  • In this study, the performance characteristics of a welded plate heat exchanger was investigated experimentally. Performance tests were carried out according to the flow rate and inlet temperature of working fluid. As a result, the heat transfer capacity increased by 335.5 kW with an increasing the flow rate and temperature difference between hot and cold side. However, the overall heat transfer coefficient was increased with the increase of flow rate, and it was not effected significantly from inlet temperature difference between hot and cold working fluid. The pressure drop was increased by 55.78 kPa with an increasing the frow rate when the flow rate ratio between hot and cold side 1:1. However, the tendency of pressure drop was difference when flow rate ratio wasn't 1:1. In case that the flow rate ratio between hot and cold side was not 1:1, the pressure drop at the low flow rate side was higher than that when the flow rate ratio was 1:1, while pressure drop of the other side was decreased compared to that when the flow rate ratio was 1:1.

A Study on the Performance of Natural Ventilation of Solar Chimney Using Stack Effect (연돌 효과를 이용한 태양열 굴뚝의 자연환기 성능에 관한 연구)

  • Cho, S.W.;Lee, J.Y.
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.2
    • /
    • pp.35-43
    • /
    • 2001
  • The results of numerical simulation on the performance of a solar chimney system in building are described. The inside surface temperature of four walls within the solar chimney arc calculated with solar radiation and outdoor temperature in summer. The air within the solar chimney is heated by conduction, convection and radiation. Air temperature distribution from the bottom to the top and outlet air temperature can be obtained by solving energy balance equation. Since the buoyance or stack effect is affected by temperature difference between the bottom and the top within the solar chimney. It is evaluated using inlet and outlet temperatures. It is expected that natural ventilation by the solar chimney of witch the height is 7.8m and the cross sectional area is $4.93m^2$ can provide about $6400m^3/h$ on sunny day.

  • PDF

A Study on the Reduction of $NO_x$ Emission from Dual Fuel Engine for Co-generation System (열병합발적용 Dual Fuel Engine의 질소산화물 배출저감에 관한 연구)

  • 정일래;김용술;심용식
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.31-40
    • /
    • 1991
  • This study shows the correlation between $NO_x$ emission in the exhaust gas and various operation factors of dual fuel engine for Co-generation system. General tendency was shown that the thermal efficiency was lowered by the change of operation factors. However these were not confirmed on this experiment. Increasing T4 temperature (exhaust gas temperature at turbo-charger inlet) reduces $NO_x$ emission rate. The higher T4 temperature requires lower excess air as the excess air ratio is controlled by T4 temperature on gas mode operation. Another tendency was that $NO_x$ emission rate is reduced in case of increasing boost air temperature, quantity of pilot oil or bypassing flue gas through the exhaust gas boiler. The diameter of the fuel injection nozzle was changed smaller than design value and the injection timing was readjusted. Thus $NO_x$ emission rate could be reduced as retarding injection timing and changing hole diameter of fuel injection nozzle, however maxium engine out-put was decreased by changing fuel nozzle on the diesel mode operation.

  • PDF

Analysis of Temperature Distribution of Solid and Gas in the Rotary Cooler (회전냉각기에서 고체와 가스의 온도분포해석)

  • 이만승;최주석;전철근
    • Resources Recycling
    • /
    • v.11 no.3
    • /
    • pp.25-30
    • /
    • 2002
  • Heat transfer occurring in the rotary cooler was analyzed by applying a one-dimensional steady state. The temperature of inlet gas and the measured temperature of outlet gas were used as boundary conditions. Axial temperature distribution of solid, gas and wall were calculated by solving two differential equations and two algebraic equations under the constraint of two point boundary conditions and operating conditions. The temperatures of outer wall calculated in this study were in good agreement with those measured from running rotary cooler.

An experimental study on piston temperature measurement at various locations in a S.I. engine utilizing L-LINK mechanism (L-LINK를 이용한 S.I.엔진 피스톤 각 부위의 온도측정에 대한 실험적 연구)

  • 김승수;김지연
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.9 no.3
    • /
    • pp.55-65
    • /
    • 1987
  • This paper presents the method of piston temperature measurement and its data under various engine operating conditions. In case of high speed engine, the thermocouple wires must be guided from moving piston to stationary place with carful attention. for this purpose L_LINK SYSTEM was made and assembled to a passenger car engine on the test bench and then the piston temperature was successfully measured. The tested engine speed ranged from 1,000 to 4,000 rpm with 500 rpm increments. Not only the effects of engine speed and load on the piston temperature but those of spark timing, detonation, coolant temperature and Reynolds number based on inlet air condition were studied form the measurement obtained by this L_LINK SYSTEM.

  • PDF

A Study on Performance Characteristics of A Single Effect LiBr/Water Refrigeration Cycle (단효용 LiBr/물 흡수식 냉동사이클의 성능특성에 관한 연구)

  • 연제문;임삼택;오주원;이경우
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.95-99
    • /
    • 2001
  • As a way to use energy effectively, the present study is aimed at investigating the performance characteristics of a Single Effect LiBr/Water Absorption Refrigerator using a low temperature driving heat-source. It was carried out by changing the driving heat-source temperature, the cold water outlet temperature(the refrigeration load), the cooling water inlet temperature, and the weak solution flow rate and this study compares the performance characteristics of refrigerator against the existence and non-existence of the Recirculation of the Weak solution which is used as a method to improve the performance of refrigerator. In case of Recirculation of the weak solution, more improved the Refrigeration Capacity and COP was obtained, and these effects became more larger in the high temperature of driving heat-source and large quantity of solution.

  • PDF

A Numerical Study on Transient Performance Behavior of a Turbofan Engine with Variable Inlet Guide Vane and Bleed Air Schedules (가변 입구 안내익과 블리드 공기 스케줄에 따른 터보팬 엔진에서의 천이 성능특성에 관한 수치연구)

  • Kim, Sangjo;Son, Changmin;Kim, Kuisoon;Kim, Myungho;Min, Seongki
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.19 no.5
    • /
    • pp.52-61
    • /
    • 2015
  • This paper performed a numerical study to analyse the transient performance behavior of a turbofan engine with variable inlet guide vane (IGV) and bleed air schedules. The low bypass ratio mixed flow turbofan engine was considered in this study. For modeling the compressor performance with IGV, the performance maps were generated by using a one-dimensional meanline analysis and feed to the engine simulation program. The IGV and bleed air according to the rotating speed were scheduled to satisfy 10% of surge margin at steady-state condition. The transient engine performance analysis was conducted with the schedules. The engine with IGV schedule showed a higher surge margin and lower turbine inlet temperature than the engine with bleed air schedule during the transient period.

Numerical Investigation on Multi-stage Axial Fan and Compressor for Considering Pressure Losses by Instrumentation and Area-averaged Properties (측정장치 압력손실과 면적평균 물리량 보정을 위한 다단 축류 팬과 압축기의 수치해석적 연구)

  • CHOI, JAEHO;KIM, SEMI;LEE, WONSUK;CHOI, TAEWOO;KIM, JINWOOK
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.29 no.4
    • /
    • pp.401-409
    • /
    • 2018
  • A numerical investigation has been conducted to find the effects of pressure losses by struts and rakes, and averaging methods on the performance of a multi-stage axial fan and a multi-stage axial compressor. Struts and rakes which produce pressure losses are installed upstream of the aerodynamic inlet plane in the fan and the compressor rigs. Some of normal stator vanes are substituted with thick vanes with total pressure probes to measure total pressure between stages. Three-dimensional Reynolds-averaged Navier- Stokes equations with $k-{\omega}$ SST turbulence model were applied to analyze the pressure losses by the struts, inlet rakes, and thick instrumented vanes. The hexahedral grids were used to construct computational domain. Inlet pressure losses were evaluated for the compressor as a function of Mach number. The passage pressure losses due to the instrumented vanes were evaluated at the two speed lines in the fan. Total properties, such as pressure and temperature, were evaluated at the exit of the fan and the compressor with two different averaging methods which are area-averaging and mass-averaging, respectively.

Effect of Parameters on the Two-Phase Flow Distribution Characteristics of Refrigerants in a Horizontal T-Junction (수평 T형 분지관 내 냉매 이상유동 분배특성에 미치는 변수들의 영향)

  • Tae Sang-Jin;Cho Keumnam
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.1
    • /
    • pp.31-37
    • /
    • 2006
  • The present study has been experimentally investigated the effect of geometric and operating parameters on the two-phase flow distribution of refrigerants in a horizontal T-junction. The operating parameters were the kind of refrigerants (R-22, R- l34a, and R-410A), saturated temperature, and the inlet mass flux and quality. The geometric parameters were the tube diameter and the tube diameter ratio. The measured data of refrigerants were compared with the values predicted using the models developed by several researchers for air/water or steani/water two-phase flow. Among the operating parameters, the inlet Quality was the most sensitive to the mass flow rate ratio. Between the geometric parameters, the tube diameter ratio was more sensitive than tube diameter.