• 제목/요약/키워드: Inlet Part

검색결과 275건 처리시간 0.026초

30kVA 초전도 전동기의 기기상수 (Machine Constants of 30 kVA Superconducting Synchronous Motor)

  • 최경달;한송엽;츠키지히로시;호시노토모노리;무타이쯔야
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 A
    • /
    • pp.34-36
    • /
    • 1996
  • For the test of the operating characteristics as a moor, a 20 kVA super conducting synchronous machine with rotating field windings has been made in Saga university, Japan from 1991. Before the load tests of it as a motor, we carried out cooling down tests and measured its machine constants. During the cooling down tests, we found that the rotor itself had no cryogenic problem, but the inlet part for liquid He had one. Though enough liquid He couldn't be accumulated inside the rotor because of this problem, we drove field currents up to 20 A and could acquire the machine constants and V curves of the super-conducting synchronous motor.

  • PDF

단면의 폭이 감소하는 180^{\circ}$ 곡덕트 내 난류유동의 수치해석적 연구 (Numerical Study on the Turbulent Flow in the 180^{\circ}$ Bends Decreasing Cross-sectional Aspect Ratio)

  • 김원갑;최영돈
    • 설비공학논문집
    • /
    • 제14권12호
    • /
    • pp.1056-1062
    • /
    • 2002
  • This paper reports the characteristics of the three dimensional turbulent flow in the 180 degree bends with decreasing cross-sectional area by numerical method. Calculated pressure and velocity, Reynolds stress distributions are compared to the experimental data. Turbulence model employed are low Reynolds number k-epsilon model and algebraic stress model. The results show that the main vortex generated from the inlet part of the bend maintained to outlet of the bend because of the contraction of cross-sectional area. The rate of increase of turbulent kinetic energy through the bend are lower than that of mean flow. Secondary flow strength of the flow is lower about 60% than that of square duct flow.

Amino acid Thiohydantoin 유도체(誘導體)의 질량분석(質量分析) (제 I 보)(第 I 報) (Mass Spectrometric Identification of Thiohydantoins Derived from Amino Acids (I))

  • 송경덕
    • 한국식품영양과학회지
    • /
    • 제3권1호
    • /
    • pp.53-68
    • /
    • 1974
  • The thiohydantoin derivative derived from amino acid was used for the stepwise sequence analysis of peptide or protein from the carboxyl termini. Recently, SUZUKI reported the mass spectrometric identification about a part of these compounds. In this paper, was described the mass spectrometric identification of thiohydantoins derived from 20 amino acids. Mass spectra were obtained with a mass spectrometer, JEOL model JMS-06H and samples were introduced with a direct inlet probe. The molecular ion peaks and fragment ion peaks were identified easily, because these peaks appeared differently every amino acids and specially, it was easy discrimination between leucine and isoleucine. It is suggested that mass spectrometry was one of the useful methods to identify thiohydantoins derived from amino acids.

  • PDF

헬리콥터용 터보샤프트엔진 2단 축류압축기 개량설계 (Design of Two Stage Axial Compressor of a Turbo Shaft Engine for Helicopters)

  • 김진한;김춘택;이대성
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1998년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.183-190
    • /
    • 1998
  • This paper introduces the part of efforts to develop a derivative type turbo-shaft engine from an existing baseline engine for multi-purpose helicopters targeting at 4000kg of take-off weight for 10-12 passengers. As a first step in meeting the development goal of increasing the output power to 840hp from 720hp with minimum modification, two stage axial compressor was redesigned to obtain the higher pressure ratio by removing the inlet guide vane and increasing the chord length. As a result, two stage axial compressors were designed to have the flow rate of 3.04 kg/s, the pressure ratio of 2.01 and the adiabatic efficiency of $85\%$. Its performance tests were carried out and verification of test results and redesign are under progress. Aerodynamic and structural analyses of the preliminary design are mainly described in this paper.

  • PDF

수리특성을 고려한 수로터널 설계 (Design Consideration for Tunnel Spillway related to Hydraulic Characteristics)

  • 윤동덕;김태혁;이중우;오명렬
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2006년도 추계 학술발표회
    • /
    • pp.161-168
    • /
    • 2006
  • The recent unpredictable weather condition, especially abnormal heavy precipitation which is on the verge of PMF, made implement more rigorous design standard. Following these trends, the idea of additional auxiliary spillway, most of them are tunnel around existing one, is adopted to many sites. Tunnel spillway, having free water table is generally consisted of several compartments such as inlet, transition, inclined, curved and stilling parts. It may has some technical problems to be considered. Among them, the surface deterioration due to cavitation is reported many times in the part of irregularities on lining. Including this kind of problem, several technical considerations for tunnel spillway will be handled in this paper during design procedure.

  • PDF

항공사진을 이용한 경안천 하천변화추세 분석 (Analysis of Gyeong-an Stream Change using Multi-temporal Aerial Photographs)

  • 박근애;이미선;김현준;김성준
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2003년도 학술발표논문집
    • /
    • pp.67-70
    • /
    • 2003
  • This study is to trace the change of stream shape using the past series of aerial photographs and compare the land use changes of inland along the stream. For the Gyeong-an national stream, aerial photographs of 1966, 1981 and 2000 was selected and ortho photograph was made with RMSE of 1.25, 0.54, 0.72 pixels, respectively. As apparent changes of the stream, the consolidated reaches of stream with levee construction were straightened and their stream width widened. Especially the stream width of inlet part of Paldang lake was widened almost twice because of the rise of water level by dam construction in 1974.

  • PDF

간극에서의 역방향 유동 제한 현상 연구 (Counter-Current Flow Limit in Narrow Gap)

  • 김용훈;서균렬
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.1054-1060
    • /
    • 1998
  • Previous counter-current flow limitation (CCFL) and critical heat flux (CHF) studies included investigations on the inlet entrance, inclined channel and gap effects for the most part. In this study, the local CHF correlation was presented to be used in the numerical analysis for the 3 dimensional hemispherical geometry. Also, first-principle analyses were performed to determine the maximum heat removal capability from the debris through the gap that may be formed during a core melt accident. The maximum heat removal capability by gap cooling can be applied in quantitatively assessing the severe accident management measures.

  • PDF

Analysis of River Channel Morphology and Riparian Land Use Changes Using Aerial Photographs and GIS

  • Park Geun Ae;Lee Mi Seon;Kim Hyeon Jun;Kim Seong Joon
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.566-569
    • /
    • 2004
  • This study is to trace the change of stream shape using the past series of aerial photographs, and to compare the land use changes of riparian area along the stream. For the Gyeongan national stream, aerial photographs of 1966, 1981 and 2000 were selected and ortho photographs were made with interior orientation and exterior orientation, respectively. As apparent changes of the stream, the consolidated reaches of stream with levee construction were straightened and their stream widths were widened. Especially the stream width of inlet part of Paldang lake was widened almost twice because of the rise of water level by dam construction in 1974. The land use maps (1966, 1981,2000) of riparian areas were also made, respectively and classified into 6 categories (water, forest, agricultural land, urban area, road, sandbar) by digitizing. The area of forest and agricultural land decreased and urban area increased as the stream maintenance was performed.

  • PDF

마이크로 가스터빈 발전시스템의 운전성능 분석 (Analysis of Operation Performance of a Micro Gas Turbine Generator System)

  • 이종준;김동섭
    • 한국유체기계학회 논문집
    • /
    • 제8권5호
    • /
    • pp.13-21
    • /
    • 2005
  • This study aims to analyze operating performance of a micro gas turbine with the aid of detailed measurements of various system parameters. In addition to embedded measurements, parameters such as exhaust temperatures, engine inlet temperatures and fuel flow rates are measured. Variations in measured data and estimated performance parameters are analyzed. Those data are processed to calculate losses along the power transmission line and the net gas turbine performance (power and efficiency based on the gas turbine shaft end) is isolated from the overall system performance. A method to estimate characteristic parameters such as component efficiencies, based on the comparison between measured and predicted performance data, is suggested and exemplified for the full load condition.

공기조화기 축류팬의 공력소음 특성 연구 (The Study on the Aeroacoustic Characteristics of an Axial Fan for an Air-Conditioner)

  • 이수영;한재오;김태헌;이재권;전완호
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.205-208
    • /
    • 2006
  • This paper proposes a new computational aeroacoustics method for an axial fan analysis. The major aeroacoustic noise source of an outdoor air-conditioner is the axial fan. It was revealed that the dominant noise source is the aerodynamic interactions between the rotating blade and stationary orifice. Many researches were focused on the fan only case. However, it does not fit to a real outdoor unit of air-conditioner. Especially, the inlet part of the axial fan of real system case is complex and not uniform. So, in order to identify the dominant noise source of axial fan, full outdoor unit analysis is important. Transient CFD analysis of full system was performed by commercial CFD code - SC/Tetra. Dominant noise source of the system was calculated by commercial CFN code - FlowNoise. The results show that not only BPF peaks but also broadband noise are similar to the measured data.

  • PDF