• Title/Summary/Keyword: Inlay Technique

Search Result 57, Processing Time 0.021 seconds

A THREE DIMENSIONAL FINITE ELEMENT ANALYSIS WITH CAVITY DESIGN ON FRACTURE OF COMPOSITE RESIN INLAY RESTORED TOOTH (복합레진 인레이 수복시 와동형태에 따른 치아파절에 관한 유한요소법적 연구)

  • Kim, Chull-Soon;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.1
    • /
    • pp.231-254
    • /
    • 1994
  • Fracture of cusp, on posterior teeth, especially those carious or restored, is major cause of tooth loss. Inappropriate treatments, such as unnecessarily wide cavity preparations, increase the potential of further trauma and possible fracture of the remaining tooth structures. Fracture potential may be directly related to the stresses exerted upon the tooth during masticatory function. The purpose of this study is to evaluate the fracture resistance of tooth, restored with composite resin inlay. In this study, MOD inlay cavity prepared on maxillary first premolar and restored with composite resin inlay. Three dimensional finite element models with eight nodes isoparametric solid element, developed by serial grinding-photographing technique. These models have various occlusal isthmus and depth of cavity, 1/2, 1/3 and 1/4 of isthmus width and 0.7, 0.85 and 1.0 of depth of cavity. The magnitude of load was 474 N and 172 N as presented to maximal biting force and normal chewing force. These loads applied onto ridges of buccal and lingual cusp. These models analyzed with three dimensional finite element method. The results of this study were as follows : 1. There is no difference of displacement between width of occlusal isthmus and depth of cavity. 2. The stress concentrated at bucco-mesial comer, bucco-disal comer, pulpal line angle and the interface area between internal slopes of cusp and resin inlay. 3. The vector of stress direct to buccal and lingual side from center of cavity, to tooth surface going on to enamel. The magnitude of vector increase from occlusal surface to cervix. 4. The crack of tooth start interface area, between internal slop of buccal cusp and resin inlay. It progresses through buccopulpal line angle to cervix at buccomesial and buccodistal comer. 5. The influence with depth of cavity to fracture of tooth was more than width of isthmus. 6. It would be favorable to make the isthmus width narrower than a third of the intercuspal distance and depth of cavity is below 1 : 0.7.

  • PDF

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • v.41 no.2
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.

THE MARGINAL SEALING EFFECT OF COMPOSITE RESIN INLAYS ACCORDING TO THE LUTING TECHNIQUES (합착방법(合着方法)에 따른 복합(複合)레진 인레이의 변연폐쇄효과(邊緣閉鎖效果))

  • Moon, Young-Deok;Cho, Kyeu-Zeung
    • Restorative Dentistry and Endodontics
    • /
    • v.16 no.1
    • /
    • pp.121-132
    • /
    • 1991
  • The purpose of the study was to evaluate the marginal sealing effect of composite resin inlays according to the luting techniques and compare them to the conventional direct resin filling technique. 90 cavities of class V were prepared on the buccal surface of 90 extracted molar teeth, which were divided into four groups. Cavities of control group were directly filled with Scotchbond 2 and P - 50, and those of composite resin inlay groups were luted with one of the followings: Adhesive bond followed by Adhesive cement, All bond followed by Adhesive cement, Fuji - ionomer type L All the specimens were immersed in India ink dye solution for 7 days at $37^{\circ}C$ incubator after thermocycling between $5^{\circ}C$ and $60^{\circ}C$ and longitudinally sectioned with diamond disk inot two parts All the specimens were observed at the occlusal and gingival margins and statistical analysis was performed. The results were as follows: 1. Groups filled with composite resin inlay showed less marginal leakage than the group directly filled(p<0.01). 2. There was no significant difference in marginal leakage between composite resin inlay groups luted with Adhesive bond followed by Adhesive cement and the group luted with All bond followed by Adhesive cement(p>0.05). 3. At occlusal margins, Composite resin inlay group luted with Adhesive bond followed by Adhesive cement showed less marginal leakage than the group luted with Fuii ionomer type I(p<0.01). At gingival margins, composite resin inlay group luted with All bond followed by Adhesive cement showed less marignal leakage than the group luted with Fuji ionomer type I(P<0.01).

  • PDF

Management of the PCL Injuries (후방 십자 인대 손상의 치료)

  • Jung, Young Bok;Jung, Ho Joong
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.25-32
    • /
    • 1998
  • The distinction between isolated and combined injuries is crucial both for treatment and prognosis. For most combined injuries, surgical treatment continues to be favored over nonoperative treatment. It is generally agreed that isolatel PCL injuries do well without surgery. There has been an interest by many authors to fix the graft directly to the posterior aspect of the tibia(tibial inlay). With this procedure, tibial graft fixation will be more direct and theoretically reduce the bending effects of the graft with a fixation site far away from the tibial insertion. Modified tibial inlay technique, which is the posterior approach does not require the patient to be in the prone or lateral decubitus position during the operation. Use of a double-bundle reconstructive technique is attractive and has been performed by some surgeons. At this time, this procedure is still being investigated and should not be routinely used in the clinical setting until studies have indicated an advantage over current single-bundle techniques. However theologically, double-bundle reconstructive technique is more useful in severe posterior unstable knee. Recent advances have increased our knowledge of the anatomy and mechanical characteristics of the PCL. Basic science research has further increased our awareness of the interaction of the posterolateral structures with the PCL. To achieve restoration of normal posterior laxity, it is critical to address the posterior as well as the postero-lateral structures. Surgical treatment is often complex and requires a wide range of surgical techniques and skills to treat associated injuries. When the PCL is reconstructed, most surgeons choose to reconstruct the anterolateral component using a graft of sufficient size and strength. The initial postoperative rehabilitation should be addressed cautiously in an effort to avoid excessive forces on delicate repairs and reconstructions in these complex injuries. Further research is necessary to evaluate new surgical approaches such as double-bundle reconstructions and tibial inlay techniques as well as improved techniques for capsular and collateral ligament injuries.

  • PDF

Clinical comparison of marginal fit of ceramic inlays between digital and conventional impressions

  • Franklin Guillermo Vargas-Corral;Americo Ernesto Vargas-Corral;Miguel Angel Rodríguez Valverde;Manuel Bravo;Juan Ignacio Rosales Leal
    • The Journal of Advanced Prosthodontics
    • /
    • v.16 no.1
    • /
    • pp.57-65
    • /
    • 2024
  • PURPOSE. The aim of this stuldy was to compare the clinical marginal fit of CAD-CAM inlays obtained from intraoral digital impression or addition silicone impression techniques. MATERIALS AND METHODS. The study included 31 inlays for prosthodontics purposes of 31 patients: 15 based on intraoral digital impressions (DI group); and 16 based on a conventional impression technique (CI group). Inlays included occlusal and a non-occlusal surface. Inlays were milled in ceramic. The inlay-teeth interface was replicated by placing each inlay in its corresponding uncemented clinical preparation and taking interface impressions with silicone material from occlusal and free surfaces. Interface analysis was made using white light confocal microscopy (WLCM) (scanning area: 694 × 510 ㎛2) from the impression samples. The gap size and the inlay overextension were measured from the microscopy topographies. For analytical purposes (i.e., 95-%-confidence intervals calculations and P-value calculations), the procedure REGRESS in SUDAAN was used to account for clustering (i.e., multiple measurements). For p-value calculation, the log transformation of the dependent variables was used to normalize the distributions. RESULTS. Marginal fit values for occlusal and free surfaces were affected by the type of impression. There were no differences between surfaces (occlusal vs. free). Gap obtained for DI group was 164 ± 84 ㎛ and that for CI group was 209 ± 104 ㎛, and there were statistical differences between them (p = .041). Mean overextension values were 60 ± 59 ㎛ for DI group and 67 ± 73 ㎛ for CI group, and there were no differences between then (p = .553). CONCLUSION. Digital impression achieved inlays with higher clinical marginal fit and performed better than the conventional silicone materials.

Inlay graft of acellular dermal matrix to prevent incisional dehiscence after radiotherapy in prosthetic breast reconstruction

  • Kim, Mi Jung;Ahn, Sung Jae;Fan, Kenneth L.;Song, Seung Yong;Lew, Dae Hyun;Lee, Dong Won
    • Archives of Plastic Surgery
    • /
    • v.46 no.6
    • /
    • pp.544-549
    • /
    • 2019
  • Background As the indications for postmastectomy radiotherapy expand, innovative solutions are required to reduce operative complications and reconstructive failure after prosthetic breast reconstruction. In this study, we investigated the effectiveness of acellular dermal matrix (ADM) inlay grafts in preventing postoperative wound dehiscence of irradiated breasts in the context of prosthetic breast reconstruction. Methods A retrospective analysis was conducted of 45 patients who received two-stage prosthetic reconstruction and radiotherapy following mastectomy. An ADM graft was placed beneath the incisional site during the second-stage operation in 19 patients using marionette sutures, whereas the control group did not receive the ADM reinforcement. Patient demographics and complications such as wound dehiscence, capsular contracture, peri-prosthetic infection, cellulitis, and seroma were compared between the two groups. Results During an average follow-up period of 37.1 months, wound dehiscence occurred significantly less often in the ADM-reinforced closure group (0%) than in the non-ADM group (23.1%) (P=0.032). There was no significant difference between the two groups in relation to other complications, such as capsular contracture, postoperative infection, or seroma. Conclusions The ADM inlay graft is a simple and easily reproducible technique for preventing incisional dehiscence in the setting of radiotherapy after prosthetic breast reconstruction. The ADM graft serves as a buttress to offload tension during healing and provides a mechanical barrier against pathogens. Application of this technique may serve to reduce complications in prosthetic breast reconstruction after radiotherapy.

Clinical Significance of Orbital Inferiomedial Blow Out Fracture (안와하내벽 파열골절의 임상적 의의)

  • Yoo, Jae Hong;Ha, Won;Lee, Ji Won;Yang, Wan Suk
    • Archives of Craniofacial Surgery
    • /
    • v.14 no.1
    • /
    • pp.24-29
    • /
    • 2013
  • Background: The incidence of blow out fractures is increasing and the techniques of diagnosis and treatment have been recently evolving. Despite its clinical significance, there has been no study on orbital inferiomedial blow out fractures. Therefore, this study was designed to investigate the clinical significance of treatment of orbital inferiomedial blow out fractures. Methods: A retrospective review of fifty-seven patients who could be followed up for at least 1 year after surgical reconstruction of pure inferiomedial blow out fracture was undertaken. The transconjunctival approach was performed in all cases. The onlay technique was used in 32 patients and the inlay/sheet method was used in 25 patients. We evaluated the clinical outcomes using the chi-square test. Results: In the group using the onlay technique, postoperative diplopia and enophthalmos were observed in 14 cases and 3 cases, respectively. Of these, 5 cases and 3 cases lasted for more than 6 months, respectively. In the group using the inlay/sheet method, postoperative diplopia was observed in 9 cases, but there were no cases of enophthalmos. Among the 9 diplopia cases, 4 lasted for more than 6 months. Conclusion: Postoperative diplopia and enophthalmos were increased after treatment of inferiomedial blow out fractures compared to isolated medial (0.6%, 0.3%) or inferior (1.8%, 0.6%) blow out fractures. Therefore, careful dissection is necessary not to injure the inferior oblique muscle to decrease the incidence of postoperative diplopia. Moreover, the inlay/sheet method is an effective option for reconstruction of inferiomedial blow out fractures.

Acquisition and Processing of 3D Data (3차원 데이터의 획득 및 가공)

  • Kim A.H.;Kim Y.S.;Bae C.;Kang W.C.;Kim Y.D.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.286-290
    • /
    • 2003
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Two camera method keeps accuracy more than double than mechanical method. In this paper, we describe the processes surface data of teeth for automatic processing, transformation that changes to coping data of possible numeric data form and processed inlay teeth. As the result of the Inlay manufacture, which can process with high resolution, therefore we construct the automatic processing system that depends on manual

  • PDF

3D Processing System of Tooth shape (치형 3차원 가공시스템)

  • Kim, Young-Su;Kim, Nam-Oh;Min, Wan-Ki;Shin, Suck-Doo;Kang, Won-Can;Kim, Young-Dong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07e
    • /
    • pp.120-123
    • /
    • 2003
  • Accurate acquisition of surface geometries such as machined surfaces, biological surfaces, and deformed parts have been very important technique in scientific study and engineering, expecially for system design, manufacturing and inspection. Two camera method keeps accuracy more than double than mechanical method. In this paper, we describe the processes surface data of teeth for automatic processing, transformation that changes to coping data of possible numeric data form, and processed inlay teeth. As the result of the Inlay manufacture, which can process with high resolution, therefore we construct the automatic processing system that depends on manual.

  • PDF

CORRELATION BETWEEN BIS-GMA : TEGDMA RATIO AND DEGREE OF CONVERSION IN VARIOUS LAYERS OF COMPOSITE AFTER ADDITIONAL HEAT CURING (수종 복합레진 내의 bis-GMA와 TEGDMA의 구성비가 레진 인레이 법에 의한 부가적 열처리시 복합레진의 표면 및 내부의 중합률 변화에 미치는 영향)

  • Park, Seong-Ho;Chung, Chan-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.21 no.2
    • /
    • pp.642-651
    • /
    • 1996
  • The purpose of this study was to evaluate the relationship between monomer compositions and the changes in the degree of conversion in the various layers of composites after additional heat curing. Four types of composites and 3 types of inlay ovens were used in this study. Composite was placed in a 4-mm thick teflon mold, and light cured from the top for 60 seconds. Ten samples were prepared for each composite ; 5 of these were additionally heat cured in an inlay oven as the manufacturer recommended. After light curing or light and heat curing, the samples were sectioned into four parts and assigned to groups A, B, C, or D according to their distance from the light source. These sections were then thinned to 50-$70{\mu}m$, and these wafers were analyzed with a Fourier Transform Infrared Spectrometer(FI-IR) to determine the degree of conversion. A standard baseline technique was used to calculate the degree of conversion. $^{13}C$ NMR spectra of bis-GMA, TEGDMA and bis-EMA, were acquired using a Varian Gemini spectrometer operated at 200 MHz. $CDCl_3$ solvent was used for qualitative analysis. The degree of conversion was affected by bis-GMA : TEGDMA ratio but it seemed to be also affected by other factors. When the composites were heat cured, significant increases in the degree of conversion were noted throughout the samples, but the amount of increase differed between materials. Thus, clinical performance of a heat-treated composite inlay may be different depending on materials.

  • PDF