• Title/Summary/Keyword: Injection site

Search Result 559, Processing Time 0.029 seconds

Abdominal skin subcutaneous fat thickness over the gestational period in Korean pregnant women: a descriptive observational study

  • Hwang, Moon Sook
    • Women's Health Nursing
    • /
    • v.27 no.4
    • /
    • pp.318-325
    • /
    • 2021
  • Purpose: Although insulin is usually injected into the abdominal subcutaneous fat, in pregnancy women tend to avoid abdominal injections due to concern about fetal damage. Prior studies have been limited to only measuring skin-subcutaneous fat thickness (S-ScFT) at one site at specific pregnancy points. This study aimed to measure S-ScFT across several abdominal sites and over the gestational period in Korean pregnant women. This can identify which site would be relatively safe for subcutaneous injection during pregnancy. Methods: Healthy women over 24 weeks of pregnancy in Korea were invited to voluntarily participate in this descriptive study. For the 142 women, S-ScFT of 12 sites in the abdomen were measured by ultrasound, several times over the pregnancy. Each incidence was treated as a case and a total of 262 cases were analyzed. Results: The mean S-ScFT during pregnancy was 1.14±0.47 cm (1.25±0.54 cm at 24+0-27+6 weeks; 1.17±0.48 cm at 28+0-31+6 weeks; 1.09+0.40 cm at 32+0-35+6 weeks; and 1.06±0.47 cm at 36+0-40 weeks of pregnancy). Most S-ScFT were thicker than 10 mm. But S-ScFTs in the lateral abdomen and some sites were suboptimal (<6 mm), especially in the pre-pregnancy underweight body mass index group, who had a high rate of suboptimal thickness (27.1% overall and 33.9% in the lateral side). Conclusion: The whole abdomen seems to be appropriate for subcutaneous injection in most Korean women during pregnancy, with a 4 to 5-mm short needle. However, for the lateral abdomen, making the skin fold might be needed for fetal safety.

Stabilization of Solid Waste in Lysimeter by Air Injection Mode (공기주입 방식을 이용한 매립모형조내 폐기물 안정화)

  • Kim, Kyung;Park, Joon-Seok;Lee, Hwan;Lee, Cheol-Hyo;Kim, Joung-Dae
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.1
    • /
    • pp.15-22
    • /
    • 2005
  • This study was conducted to evaluate air injection mode on stabilization of solid waste in lysimeter. For three lysimeters, one was maintained under anaerobic condition as control, and air was injected into two lysimeters in continuous mode (atmospheric pressure) and intermittent mode (high pressure of 2 bar). Distilled water was sprayed over solid waste in 1.4 l/$m^3$(solid waste)/day, supposing rainfall intensity of 1,200 mm/yr and 30% infiltration. Oxygen in landfill gas was not detected in control lysimeter during operational days. After 30 day-aeration, oxygen concentrations of continuous and intermittent modes were maintained in 14% and 6%, respectively. $COD_{Cr}$ removal efficiencies of continuous and intermittent modes were about 70% and 50%, and BOD5 removal efficiencies were about 80% and 20%, respectively. In view of oxygen supply, and $COD_{Cr}$ and $BOD_5$ removal, continuous air injection mode of atmospheric pressure was more effective than intermittent mode of 2 bar. Settling degree of solid waste in case of two air injection modes was 3 times higher than that of anaerobic condition as control. Considering the above results, it was thought that air injection (especially continuous atmospheric pressure) could improve degradation of solid waste and induce preliminary stabilization in landfill site.

Performance Evaluation of 100% RAP Asphalt Mixtures using Rapid-Setting Polymer-Modified Asphalt Emulsion for Spray Injection Application (스프레이 패칭 긴급보수용 개질 유화 아스팔트와 100% 순환골재를 사용한 상온 아스팔트 혼합물의 성능 평가)

  • Lim, Jeong-un;Kwon, Bong Ju;Kim, Doo Youl;Lee, Sang Yum;Rhee, Suk Keun
    • International Journal of Highway Engineering
    • /
    • v.18 no.2
    • /
    • pp.61-71
    • /
    • 2016
  • PURPOSES: The objective of this study was to determine the optimum ratio of mix design, for a reclaimed asphalt pavement (RAP) content of 100%, for spray injection application. METHODS: A literature review revealed that spray injection is an efficient and cost-effective application for fixing small defective regions of an asphalt pavement. Rapid-setting polymer-modified asphalt mixtures prepared from two types of rapid-setting polymer asphalt emulsion were subjected to Marshall stability and wet track abrasion tests, in order to identify the optimum mix designs. RESULTS and CONCLUSIONS : Different mix designs of type A and type B emulsions were prepared using RAP and virgin aggregates, in order to compare the performance and determine the optimum mix design. The performance of mixtures prepared with RAP was superior to that of mixtures containing virgin aggregates. Moreover, for optimum ratio of the design, the binder content prepared from RAP was set to 1~2% lower than that consisting of virgin aggregates. Compared to their Type A counterparts, type B mixtures consisting of a reactive emulsion performed better in the Marshall stability and wet track abrasion tests. The initial results confirmed the advantages associated with using RAP for spray injection applications. Further studies will be performed to verify the difference in the optimum mix design and performance obtained in the lab-scale test and tests conducted at the job site by using the spray injection machine.

Time-lapse crosswell seismic tomography for monitoring injected $CO_2$ in an onshore aquifer, Nagaoka, Japan (일본 Nagaoka의 육상 대수층에 주입된 $CO_2$의 관찰을 위한 시간차 시추공간 탄성파 토모그래피)

  • Saito, Hideki;Nobuoka, Dai;Azuma, Hiroyuki;Xue, Ziqiu;Tanase, Daiji
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.30-36
    • /
    • 2006
  • Japan's first pilot-scale $CO_2$ sequestration experiment has been conducted in Nagaoka, where 10400 t of $CO_2$ have been injected in an onshore aquifer at a depth of about 1100 m. Among various measurements conducted at the site for monitoring the injected $CO_2$, we conducted time-lapse crosswell seismic tomography between two observation wells to determine the distribution of $CO_2$ in the aquifer by the change of P-wave velocities. This paper reports the results of the crosswell seismic tomography conducted at the site. The crosswell seismic tomography measurements were carried out three times; once before the injection as a baseline survey, and twice during the injection as monitoring surveys. The velocity tomograms resulting from the monitoring surveys were compared to the baseline survey tomogram, and velocity difference tomograms were generated. The velocity difference tomograms showed that velocity had decreased in a part of the aquifer around the injection well, where the injected $CO_2$ was supposed to be distributed. We also found that the area in which velocity had decreased was expanding in the formation up-dip direction, as increasing amounts of $CO_2$ were injected. The maximum velocity reductions observed were 3.0% after 3200 t of $CO_2$ had been injected, and 3.5% after injection of 6200 t of $CO_2$. Although seismic tomography could map the area of velocity decrease due to $CO_2$ injection, we observed some contradictions with the results of time-lapse sonic logging, and with the geological condition of the cap rock. To investigate these contradictions, we conducted numerical experiments simulating the test site. As a result, we found that part of the velocity distribution displayed in the tomograms was affected by artefacts or ghosts caused by the source-receiver geometry for the crosswell tomography in this particular site. The maximum velocity decrease obtained by tomography (3.5%) was much smaller than that observed by sonic logging (more than 20%). The numerical experiment results showed that only 5.5% velocity reduction might be observed, although the model was given a 20% velocity reduction zone. Judging from this result, the actual velocity reduction can be more than 3.5%, the value we obtained from the field data reconstruction. Further studies are needed to obtain more accurate velocity values that are comparable to those obtained by sonic logging.

Development of a Groundwater Source Heat Pump in a Fractured Rock Aquifer (암반 대수층에서 개방형 지열 시스템의 개발 및 적용)

  • Shim, Byoung Ohan;Kim, Seong-Kyun;Choi, Hanna;Lee, Soo-Hyoung;Ha, Kyoochul;Kim, Yongchul
    • New & Renewable Energy
    • /
    • v.17 no.3
    • /
    • pp.32-41
    • /
    • 2021
  • A groundwater source heat pump (GWHP) was developed in this study by adapting a borehole heat exchanger with closed-loop and open-loop systems in a new building. In the pilot test building, the air-conditioning on the second floor was designed to employ a closed-loop system and that on the third floor had an open-loop system. The GWHP design is based on the feasibility of groundwater resources at the installation site. For the hydrogeological survey of the study site, pumping and injection tests were conducted, and the feasibility of GWHP installation was evaluated based on the air-conditioning load demand of the building. The site was found to be satisfactory for the design capacity of the thermal load and water quality. In addition, the effect of groundwater movement on the performance of the closed-loop system was tested under three different operational scenarios of groundwater pumping. The performance of the system was sustainable with groundwater flow but declined without appropriate groundwater flow. From long-term observations of the operation, the aquifer temperature change was less than 2℃ at the observation well and 5℃ at the injection well with respect to the initial groundwater temperature. This pilot study is expected to be of guidance for developing GWHPs at fractured rock aquifers.

Fresh Water Injection Test in a Fractured Bedrock Aquifer for the Mitigation of Seawater Intrusion (해수침투 저감을 위한 균열암반 대수층 내 담수주입시험)

  • Shin, Je-Hyun;Byun, Joong-Moo
    • Economic and Environmental Geology
    • /
    • v.43 no.4
    • /
    • pp.371-379
    • /
    • 2010
  • Fresh water injection test in a fractured bedrock aquifer was applied as an efficient approach to lower saline concentrations in the saltwater-freshwater transition zone formed by seawater intrusion in a coastal area. The methodology and effectiveness of fresh water injection for hydraulically controlling seawater intrusion is overwhelmingly site dependent, and there is an urgent need to characterize the permeable fractures or unconsolidated porous formations which can allow for seawater flow and transport. Considering aquifer characteristics, injection and monitoring boreholes were optimally designed and completed to inject fresh water through sand layer and fractured bedrock, respectively. We devised and used the injection system using double packer for easy field operation and maintenance. Overall fracture distribution was systematically identified from borehole image logs, and the section of fresh water injection was decided from injection test and monitoring. With fresh water injection, the fluid electrical conductivity of the monitoring well started to be lowered by the inflow of fresh water at the specific depth. And this inflow leaded to the replacement of the fluid in the upper parts of the borehole with fresh water. Furthermore, the injection effect lasted more than several months, which means that fresh water injection may contribute to the mitigation of seawater intrusion in a coastal area.

A Study on the Reinforcement Effect of Low Flow Mortal Injection Method Using Field Test (현장시험을 이용한 저유동성 몰탈주입공법의 보강효과에 관한 연구)

  • Junyeong Jang;Gwangnam Lee;Daehyeon Kim
    • The Journal of Engineering Geology
    • /
    • v.33 no.4
    • /
    • pp.599-609
    • /
    • 2023
  • In the seismic retrofitting of harbor breakwaters in Korea, the recovery rate is often uncertain due to site conditions and site conditions, and problems continue to arise. Therefore, in this study, we analyzed the recovery rate and compressive strength of the improved material through drilling survey by grouting confirmation method after applying low-fluidity mortar injection method, and furthermore, we checked the elastic modulus by downhole test and tomography to confirm the reinforcement effect of soft ground after ground improvement. The experimental results showed that the average shear wave velocity of the ground increased from 229 m/s to 288 m/s in BH-1 and BH-3 boreholes to a depth of 28.0 m, and the average shear wave velocity of the ground to a depth of 30.0 m tended to increase from 224 m/s to 282 m/s in the downhole test. This is believed to be a result of the increased stiffness of the ground after reinforcement. The results of the tomographic survey showed that the Vs of the soft ground of the sample at Site 1 increased from 113 m/s to 214 m/s, and the Vs of the sample at Site 2 increased from 120 m/s to 224 m/s. This shows that the stiffness of the ground after seismic reinforcement is reinforced with hard soil, as the Vs value satisfies 180 m/s to 360 m/s in the classification of rock quality according to shear wave velocity.

Chemical Neurolytic Block with Absolute Ethyl Alcohol on Cervical Sympathetic Ganglion in Rabbits (토끼에서 경부 교감신경절의 무수 에틸 알코올에 의한 화학적 차단)

  • Kang, Yoo-Jin;Suh, Jae-Hyun
    • The Korean Journal of Pain
    • /
    • v.7 no.2
    • /
    • pp.162-169
    • /
    • 1994
  • Blockade of cervicothoracic sympathetic ganglion (stellate ganglion controls pain on face, head, neck, shoulder, upper limbs, and upper chest, including their viscera and sympathetically maintained pain. This procedure also increases blood flow to the above areas and relieves hyperreactivity of sympathetic nervous system. Clinically, repeated stellate ganglion blocks with local anesthetic agent may become difficult with complications such as accidental intravascular or subdural injection, recurrent laryngeal nerve or bracheal plexus paralysis, pneumothorax and edema on injection site. Therefore, at times long-term cervicothoracic ganglion block with neurolytics is necessitated but its applications are prohibited by the critical structures surrounding ganglion. There are also few reports of neurolytic stellate ganglion block. This study was performed to observe the complications, gross changes of surrounding structures, and microscopic findings of ganglion cells after neurolytic block and to certify the possibility of clinical use of neruolytic stellate ganglion block. The unilateral superior cervical sympathetic ganglion of rabbit was blocked with absolute ethyl alcohol 0.4 ml at the level of cricoid cartilage. Normal ganglion was used as a control and 5 animals were sacrificed at each intervals of 7, 15 and 50 days after block. The results were as follows; 1) All experimental animals showed no specific changes of behavior, motor function. No necrotic tissues were present in the block area during the observation period. There were some gross scar tissues along the fascia of muscles surrounding the needle injection site, but gross atrophy of muscles or injured major vessels were not found. 2) Microscopically, structures of normal ganglion of rabbit were very similar to those of humans. Seven days after absolute ethyl achohol injection there were marked edema of ganglion cells and nuclei with irregular nuclear membrane. Some of the ganglion cells lost their nuclei and showed degenerative changes. Fifteen days after block, cell edema were decreased and loss of the Nissl's body was prominant. The ganglion cell structures looked close to normal but the cytoplasm and nucleus were generally contracted 50 days after block. These results suggest absolute ethyl alcohol injection on cervical sympathetic ganglion with above method mainly blocks pre- and post-synaptic fibers and the long-term neurolytic blockade of this ganglion may be possible in rabbits.

  • PDF

Biological Activity of Recombinant Human Thrombopoietin (유전자 재조합 인간의 Thrombopoietin의 생리활성)

  • Kim, Boing-Soon;Naidansuren, Purevjargal;Min, Kwan-Sik
    • Journal of Life Science
    • /
    • v.17 no.11
    • /
    • pp.1497-1504
    • /
    • 2007
  • To investigate the function and secretion of human thrombopoietin (TPO) in mammalian cells, hTPO cDNA was cloned using human liver cDNA, and recombinant hTPO (rec-hTPO) was produced in CHO cell lines. In addition, six N-linked glycosylation sites were substituted for Ala to elucidate the role of each carbohydrate chain. To analyze the biological activity, rec-hTPO protein was injected subcutaneously. Blood was withdrawn for platelet determination. The metabolic clearance rate (MCR) was also analyzed at the 1, 4, 10 and 24 hr after tail vein injection. Wild-type TPO (WT) was efficiently secreted into the medium. However, a hTPO mutant with 116 deleted nucleotides detected by PCR cloning was not secreted. The N-linked glycosylation sites had nearly the same expression quantity as rec-hTPO WT apart from mutants 3 and 4. The glycosylation site of mutant 4 appeared to be an indispensable site for hTPO secretion. Also characterized was the biological activity through an injection with rec-hTPO (10 ng) to ICR mice (7 weeks). The result of the blood analysis showed a considerable increase in the platelet number six days after He injection. To analyze the pharmacokinetics, rec-hTPO was injected into the tail vein (5 ng). The result was 200 pg/ml 1hr after this injection. Following this, it dramatically decreased and virtually disappeared 10 hours after the injection. Thus, rec-hTPO may be a treatment for thrombopenia by the production of the high active rec-hTPO. In addition, hTPO can permit the development of potent new analogues that stimulate the platelet value.

Application of single-well push-drift-pull tests using dual tracers (SF6 and salt) for designing CO2 leakage monitoring network at the environmental impact test site in Korea

  • Kim, Hong-Hyun;Lee, Seong-Sun;Ha, Seung-Wook;Lee, Kang-Kun
    • Geosciences Journal
    • /
    • v.22 no.6
    • /
    • pp.1041-1052
    • /
    • 2018
  • A single-well push-drift-pull tracer test using two different tracers ($SF_6$ and salt) was performed at the Environmental Impact Test (EIT) site to determine suitable locations for monitoring wells and arrange them prior to artificial $CO_2$ injection and leak tests. Local-scale estimates of hydraulic properties (linear groundwater velocity and effective porosity) were obtained at the study site by the tracer test with two tracers. The mass recovery percentage of the volatile tracer ($SF_6$) was lower than that of the non-volatile tracer (salt) and increased drift time may make degassing of $SF_6$ intensified. The $CO_2$ leakage monitoring results for both unsaturated and saturated zones suggest that the $CO_2$ monitoring points should be located near points at which a high concentration gradient is expected. Based on the estimated hydraulic properties and tracer mass recovery rates, an optimal $CO_2$ monitoring network including boreholes for monitoring the unsaturated zone was constructed at the study site.