• 제목/요약/키워드: Injection parameters

검색결과 1,002건 처리시간 0.033초

반응고 주조공정에서 평면도 증대를 위한 공정변수의 최적설계 (Optimal Design of Process Parameters for Flatness Improvement in Semi-Solid Casting Processes)

  • 김현구;정성종
    • 한국공작기계학회논문집
    • /
    • 제17권6호
    • /
    • pp.28-34
    • /
    • 2008
  • Mg alloy is widely used for the IT, auto and consumer electronics industries. Semi-solid casting(SSC) of magnesium alloys is used to produce high quality components. SSC process is analogous with the injection molding of plastics. The high strength and low weight characteristics of magnesium alloys render the high-precision fabrication of thin-walled components with large surface areas. To produce thin-walled magnesium alloy parts, SSC process parameters on the quality of the finished product should be clearly studied. In this paper, to select optimal process parameters, Taguchi method is applied to the optimal design of the process parameters in the SSC process. The die temperature, injection velocity and barrel temperature of the SSC process are selected for the process parameters. The effectiveness of the optimal design is verified through the CAE software.

수근관증후군에서 국소 스테로이드 주사 후 임상적, 전기생리학적 변화 (Clinical and Electrophysiological Changes after Local Steroid Injection in the Carpal Tunnel Syndrome)

  • 김지훈;이기욱;윤보라;김용덕;정언석;나상준
    • Annals of Clinical Neurophysiology
    • /
    • 제15권1호
    • /
    • pp.7-12
    • /
    • 2013
  • Background: Local steroid injection is used to treat carpal tunnel syndrome (CTS). The aim of this study was to evaluate the clinical and electrophysiological effects of local steroid injection in patients with CTS over a 3-months period. Methods: Twenty-one patients (35 hands) with clinical and electrophysiological evidence of CTS were treated by injection of triamcinolone 40 mg to the carpal tunnel. Visual analog scale (VAS), Boston Carpal Tunnel Questionnaire (BCTQ), rates of paresthesia, night awakening, and electrophysiological studies were used as outcomes. Clinical and electrophysiological assessments were performed before, 1 and 3 months after treatment. Results: Prior to treatment, 86% of patients complained of night awakening. At 1 and 3 months after injection, only 17% and 29% of the patients, respectively, had night awakening (p<0.001). All patients complained of paresthesia before the treatment. This symptom disappeared in 60% and 31% of the patients after 1 and 3 months, respectively (p<0.001). Compared to baseline, both BCTQ and VAS show significant improvement during the 3 months of the study (p<0.005). Although significant improvements in clinical parameters were shown, electrophysiological parameters were not significantly improved at 1 and 3 months. Conclusions: Local corticosteroid injection for the treatment of CTS provides significant improvement in symptoms for 3 months. On the other hand, no significant improvement was observed in electrophysiological parameters.

코어백 방식을 이용한 동시사출 성형 공정 최적화 연구 (Optimization of Multi-component Injection Molding Process Based on Core-back System)

  • 최동조;박홍석
    • 한국자동차공학회논문집
    • /
    • 제17권2호
    • /
    • pp.67-74
    • /
    • 2009
  • Injection molding have been used for manufacturing various fields of automotive interior trims for years. The demands on the injection molding technique are grown with the further development of the automobile technique and the design presentations for cost reduction and environment-friendly. This paper shows that multi-component injection conditions are different from general injection, also shows how to optimize part design and mold design and how to manufacturing through the efficient use of multi-component injection in development process using core back system. To fulfill this purpose, all influential process parameters related to the quality of automobile parts were analyzed in terms of the correlation between them. Base on that, a innovative process will be developed by injection engineers to implement it in practice.

내압력.온도센서를 갖는 표준 인장시편용 사출금형설계 및 성형 (Design of Injection Mold with Cavity Pressure/Temperature Sensors and Molding for Standard Tensile Test Specimen)

  • 이도명;한병기;이옥성;이성희
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1416-1419
    • /
    • 2005
  • Design and manufacturing of plastic injection mold with cavity pressure/temperature sensors were performed in the present study for tensile test specimen. Standards of mold-base and tensile test specimen were used to design an injection molding system. Cavity pressure and temperature sensors were placed on the side of fixed platen of injection mold machine to prevent them from external impact damage. Injection molding experiments with variations of injection speed and melt temperature were performed and polycarbonate tensile specimens were prepared for the tensile test. It was shown that injection molding processing parameters can have effect on the mechanical properties of the plastic injection molded part.

  • PDF

내압력.온도센서를 갖는 표준 인장시편용 사출금형 (Injection Mold with Cavity Pressure/Temperature Sensors for Standard Tensile Test Specimen)

  • 이도명;한병기;이성희
    • 한국정밀공학회지
    • /
    • 제24권11호
    • /
    • pp.84-90
    • /
    • 2007
  • In this study, design and manufacturing of plastic injection mold with cavity pressure/temperature sensors were performed fur tensile test specimen. International standard system for plastic tensile specimen was applied to design an injection molding system. Cavity pressure and temperature sensors were placed on the side of fixed platen of the injection mold to prevent them from external impact damage. Injection molding experiments with variations of injection speed and melt temperature were performed and then tensile test of the manufactured polycarbonate specimens was also performed. It was shown that injection molding processing parameters can have effect on the mechanical properties of the plastic injection molded part.

고압 연료 제어와 분사 특성 (A High Pressure Fuel Control and its Injection Characteristics)

  • 김상호;이용규;김재업;김응서
    • 한국자동차공학회논문집
    • /
    • 제3권6호
    • /
    • pp.123-133
    • /
    • 1995
  • An injection control valve(ICV) was designed to control the fuel flow between a common rail and an injector with two commercial solenoids. To improve the performance of ICV, the characteristic method was applied. With this method, the flow characteristics in the ICV and the injector were studied and the parameters which affect the injection characteristics were also studied. From this study, following results were obtained. The injection duration can be controlled and with modifications of the effective valve stroke of ICV, the injection quantity and duration can be reduced to desired amount. Also the injection quantity and pressure can be controlled by reducing the hole size of the injector without the variation of the injection duration. For some conditions, the desired injection characteristics can be obtained by the changes of the valve timing, the effective valve stroke, the open pressure of the injector and the hole size of the injector.

  • PDF

Subcutaneous Injection of Bee Venom in Wistar Rats: effects on blood cells and biochemical parameters

  • Yousefpoor, Yaser;Osanloo, Mahmoud;Mirzaei-Parsa, Mohamad Javad;Najafabadi, Mohammad Reza Hoseini;Hashemi, Seyyed Mohammad;Abbasifard, Mitra
    • 대한약침학회지
    • /
    • 제25권3호
    • /
    • pp.250-257
    • /
    • 2022
  • Objectives: Bee venom (BV) therapy is performed by a bee sting or subcutaneous injection of BV. However, there is not much information on the effect of BV on blood parameters after entering the body. This project aimed to assess the side effects of subcutaneous BV injections in healthy rats by measuring the hematological and biochemical parameters. Methods: Various amounts of BV, including 100, 200, and 500 (㎍/day), were subcutaneously injected into rats for 30 days. The results showed that BV affected the metabolism of the liver, kidney, and glands. Results: An increase in blood sugar and a decrease in other biochemical parameters, including cholesterol, triglyceride, urea, creatinine AST, ALT, ALP, and phosphorous, were observed. Results also showed increased counts of white blood cells, neutrophils (%), and platelets and decreased levels of red cells, hemoglobin, and hematocrit. Conclusion: This study demonstrates that BV therapy in medical clinics requires routine care and testing to prevent eventual metabolic and anemia side effects.

승용차용 플라스틱 펜더의 사출성형해석과 금형설계 (The Injection Molding Analysis and The Mold Design for Automotive Plastic Fender)

  • 김헌영;김중재;김영주
    • 소성∙가공
    • /
    • 제6권6호
    • /
    • pp.489-499
    • /
    • 1997
  • The injection molding process is analyzed to get the information on the mold design parameters and the optimum process conditions for automotive plastic front fender. The gate position, runner size and cooling channel are determined by the estimation of the flow balance, packing time, uniform cooling and shrinkage and warpage in the injection molding analyses. The procedure can be used in the mold design in the early stage when developing plastic parts.

  • PDF