• 제목/요약/키워드: Injection interval

검색결과 269건 처리시간 0.028초

충격기류식 여과집진장치의 펄스간격 밀 분사거리에 따른 압력손실변화에 관한 기초 연구 (A Study on the Pressure drop Variance of Pulse interval, injection distance in Pulse Air Jet Type Bag Filter)

  • 서정민;최금찬;박정호
    • 한국환경과학회지
    • /
    • 제13권3호
    • /
    • pp.223-232
    • /
    • 2004
  • The change of pressure drop according to the change in the inlet concentration, pulse interval, and injection distance of pulse air jet type bag filters, and the effect of venturi installation are as follows. The pressure drop with the range of 30 to $50mmH_2O$ varies according to the injection distance with 30, 50, 70, 90sec and the inlet concentration of venture built-in fabric filters. For the lower concentration of 0.5g/㎥ and 1g/㎥, the pressure $drop(\DeltaP)$ was stable 60 to 90minutes after operation. For the higher concentration of 3g/㎥, as $\DeltaP$ continues to go up, pulse interval should be set shorter than 30 seconds. The pressure drop with the injection distance of 1l0mm, when inlet dust concentration is 0.5g/㎥ or 1g/㎥, is 1.3 to 2 lower than with the injection distance of 50, 160, and 220mm, which means that the inflow amount of the secondary air by the instant acceleration is large. The injection distance of 2g/㎥ and 3g/㎥ has the similar pressure distribution. The higher inlet concentration is, the more important pulse interval is than injection distance. The pressure drop has proved to be larger when inlet concentration is lower and injection distance closer, on condition that the venturi is installed. The change in the pressure drop was smallest when injection distance was 50mm, followed by 220mm, 160mm, and 110mm.

초음파를 활용한 회전근개 간격으로 접근한 견관절 주사법 (Ultrasound Guided Shoulder Joint Injection through Rotator Cuff Interval)

  • 임종범;김영기;김성우;성규완;정일;이청
    • The Korean Journal of Pain
    • /
    • 제21권1호
    • /
    • pp.57-61
    • /
    • 2008
  • Background: Shoulder joint injection is currently performed under fluoroscopic or computed tomography scan guidance. We performed this study to determine if an ultrasound guided shoulder joint injection through rotator cuff interval would have clinical usefulness. Methods: A total of 17 volunteers [12 women, 5 men; mean age 28 yr (23-32 yr)] received shoulder joint injection under multilinear ultrasound (5-10 MHz). Volunteers were positioned supinely on a table with their arm in a neutral position. The anterior shoulder region of the patient was sterilized using povidone iodine. A 24 gauge needle was introduced and directly visualized in real time as it passed obliquely from the skin surface to the inferior space of the biceps tendon. If there was little or no resistance to the injection, a contrast media (omnipaque) was injected and checked fluoroscopically. Results: Ultrasound guided shoulder joint injection through rotator cuff interval was successful in all cases. The average time taken for the procedure was $27.5{\pm}16.5sec$. The vertical distance from skin to the inferior space of the biceps tendon was $1.6{\pm}0.4cm$ and the distance of needle from the skin to the inferior space of biceps tendon was $2.8{\pm}0.6cm$. The procedure was well tolerated by all volunteers. Conclusions: Ultrasound guided shoulder joint injection through rotator cuff interval is an effective, rapid, and easy-to-perform injection technique. Ultrasound guided injection enables exact needle placement and avoids the use of both ionizing radiation and iodinated contrast material.

황철석으로 조성된 성토구조체의 중화제 주입을 위한 최적 방안 제안 (Optimal Method for Injection of Neutralizer into Embankment Structure Composed of Pyrite Rocks)

  • 송영석;윤중만
    • 한국지반신소재학회논문집
    • /
    • 제22권4호
    • /
    • pp.73-82
    • /
    • 2023
  • 본 연구에서는 황철석 암버럭으로 시공된 성토체를 대상으로 산성배수 발생을 억제하기 위하여 중화제를 주입할 경우 최적의 주입방안을 제시하고자 한다. 성토체 내에 중화제 주입으로 인한 침투효과를 수치해석으로 검토하기 위하여 유한요소해석을 수행하였다. 수치해석을 위하여 중화제 주입관의 직경을 50mm로 선정하고 주입관의 간격을 1-4m, 주입압을 100-220kPa로 변화시키면서 침투해석을 수행하였다. 해석결과에 따르면 중화제의 주입관 간격 1.0m 및 주입압 130kPa인 경우와 주입관 간격 2.0m 및 주입압 160kPa인 경우가 상대적으로 낮은 주입압에서 성토체 전체의 포화 도달시간이 빠른 것으로 나타났다. 그리고, 성토체 전체의 포화를 위한 중화제 주입관의 간격은 3m인 경우 130kPa에서 190kPa까지 다양한 주입압을 적용할 수 있으며, 성토체의 포화 도달시간은 주입압에 상관없이 유사한 것으로 나타났다. 따라서 경제성을 고려한 최적의 중화제 주입조건으로 주입관의 간격은 3.0m, 주입압은 130kPa로 선정하였다.

주입식 총유량 자동제어방식 분관 방제기의 개발 (A Direct Injection-mixing Total-flow-control Boom Sprayer System)

  • 구영모
    • Journal of Biosystems Engineering
    • /
    • 제21권2호
    • /
    • pp.155-166
    • /
    • 1996
  • A direct injection sprayer was designed using the concepts of injection mixing and total flow control, flowrate-based system compensating for the variation of forwarding speed. A metered rate, proportionally to the actual diluent flow rate, of a tracer chemical was injected directly into the diluent stream. The injection of chemical may improve the precision and safety of chemical application process. The control system was evaluated for the variables of the control interval, tolerances and sensitivities of flow regulation valve and injection pump. Performance of the system was assessed as that the response time of flow rate, response time of injection rate, absolute steady state error, and the coefficient of variance(C.V.) of concentration were 8.5 and -0.53 seconds, 0.067 lpm(0.8%) and 3.15%, respectively, at optimal parameters of control interval of 1.0 sec, fast sensitivity of flow regulation valve, medium sensitivity of injection pump and medium tolerance of flow rate. Performance of the system can be improved by increasing the sensitivity of flow regulating valve and employing a high resolution velocimeter, such as Doppler radar.

  • PDF

커먼레일 타입 피에조 인젝터의 정밀 다단분사 제어를 위한 분사특성 연구 (A Study on the Injection Characteristics of a Piezo Injector for Controlling Accurate Multiple Injection)

  • 박희범;김형익;박상기;이기형
    • 한국분무공학회지
    • /
    • 제18권4호
    • /
    • pp.176-181
    • /
    • 2013
  • In this study, injection quantity, rate and spray image of multiple injections which are important design parameters for a piezo type injector have been investigated. Interval of injections and a number of injections in multiple injection strategy has been controlled to verify interaction of each injection. Spray characteristics of multiple injections have been researched through optical process with a high speed camera in a high pressure chamber. In addition, a method of RMS(Root Mean Square) process has been used for comprehending the distribution of injection easily. As a result, in case of piezo type injector, characteristics of injection quantity according to charging voltage and the difference of injection quantity between single and triple injection were confirmed. Also, injection rate for increasing injection duration was confirmed. And spray characteristics of multiple injections were improved; multiple injections were possible in a shorter time interval between each injection. With this study, a possibilities of more accurate multiple injection control would be expected.

2차 공기분사 및 냉각수제어에 의한 SI 엔진의 탄화수소 배기저감 (SI Engine Hydrocarbon Emissions Reduction with Secondary Air Injection and Coolant Control)

  • 박기수;조영진;박심수
    • 한국자동차공학회논문집
    • /
    • 제8권4호
    • /
    • pp.51-58
    • /
    • 2000
  • It is well known that the majority of the emissions measured from vehicle exhaust in the US Federal Test Procedure(FTP-75) are emitted during the first 60 seconds. This paper describes an experimental study on SI engine emissions reduction after cold start with interval secondary air injection and coolant control. Secondary air injection after cold start to reduce exhaust emissions causes an exothermic reaction at the exhaust port and gives sufficient air to the catalyst. For that reason engine-out emissions oxidized in the exhaust port and the rapid heating of a catalytic converter after cold start with CSAI and ISAI are estimated. The influence of the coolant temperature on SI engine emissions has been estimated. In the present studycoolant control of the cylinder head tempeature is used to investigate the effect of coolant temperature on SI engine emissions. The results show that engine-out hydrocarbon and carbon monoxide emissions are considerably reduced with interval secondary air injection and coolant control.

  • PDF

Angiographic Features and Clinical Outcomes of Intra-Arterial Nimodipine Injection in Patients with Subarachnoid Hemorrhage-Induced Vasospasm

  • Kim, Sang-Shin;Park, Dong-Hyuk;Lim, Dong-Jun;Kang, Shin-Hyuk;Cho, Tai-Hyoung;Chung, Yong-Gu
    • Journal of Korean Neurosurgical Society
    • /
    • 제52권3호
    • /
    • pp.172-178
    • /
    • 2012
  • Objective : The aim of this study was to determine the role of intra-arterial (IA) nimodipine injections for cerebral vasospasm secondary to ruptured subarachnoid hemorrhage (SAH) and to investigate the factors that influence vasodilation and clinical outcomes. Methods : We enrolled 29 patients who underwent aneurysm clipping for ruptured cerebral aneurysms between 2009 and 2011, and who received IA nimodipine after subsequently presenting with symptomatic vasospasm. The degree of vasodilation shown in angiography was measured, and the correlation between the degree of vasodilation and both the interval from SAH to cerebral vasospasm and the interval from clipping to cerebral vasospasm was determined. The change in blood flow rate after IA injection was assessed by transcranial Doppler ultrasound. Multiple clinical parameters were completed before and after IA nimodipine injection to evaluate any improvements in clinical symptoms. Results : For eight patients, Glasgow Coma Scale (GCS) scores increased by two or more points. The regression analysis demonstrated a positive correlation between the change in GCS scores after IA nimodipine injection and the change in blood vessel diameter (p=0.025). A positive correlation was also observed between the interval from SAH to vasospasm and the change in diameter (p=0.040); and the interval from clipping to vasospasm and the change in diameter (p=0.022). Conclusion : IA nimodipine injection for SAH-induced vasospasm led to significant vasodilation in angiography and improvement in clinical symptoms without significant complications. Our findings suggest that IA nimodipine injection should be utilized when intractable vasospasm develops despite rigorous conservative management.

FDM장치에서 추사간격과 시작품의 경사가 표면거칠기에 미치는 영향 (The influence of surface roughness on injection interval and part angle at FDM)

  • 하만경;전재억;정진서
    • 한국공작기계학회논문집
    • /
    • 제10권5호
    • /
    • pp.104-109
    • /
    • 2001
  • Nowadays, Industrial competition power is depended on that rapidly produce the customized products. Therefor, it is necessary to reduce period of product development. Thus, concurrent engineering that work many process at a time was appeared and Rapid prototyping was appeared, it is method that rapidly produce the prototype. If the graphic model was made by CAD, the prototype can be made in short term. That provide what the part was directly tested by the worker. It provide a worker with believable data. We study on the influence of surface roughness on injection interval and part angle at FDM.

  • PDF

Hormone의 처리방법이 Mouse의 배란, 핵 성숙도 및 체외수정에 미치는 영향 (Influences of Hormone Treatment on the Ovulation Rates, Maturation and In Vitro Fertilization of Mouse)

  • 박기상;김광식;서병부;송해범
    • 한국수정란이식학회지
    • /
    • 제7권2호
    • /
    • pp.89-96
    • /
    • 1992
  • This research was conducted to investigate the interrelationship among methods of injection of PMSG-hCG to the number of ovulated eggs, percentage of matured oocytes and in vitro fertilization using out-bred ICR mice. The results obtained are as follows, 1) The optimurn dose was 5 IU for both PMSG and hCG, while the number of ovulated eggs was 42$\pm$8, percentage of M II was 73% and in vitro fertilization rate was 81 %. 2) The optimum injection interval of PMSG-hCG was 48 hours, while the number of ovulated eggs was 48 $\pm$ 8, percentage of M II was 80% and in vitro fertilization rate was 81%. 3) The optimum time for collecting eggs was between 16 and 18 hours after hCG injection, while the numbers of ovulated eggs were 44$\pm$8, 42$\pm$7 and 43$\pm$7 in 14,16 and 18 hours after hCG injection respectively, and percentages of M II were 79 and 81 %, and in vitro fertilization rates were 81 and 80% in 16 and 18 hours after hCG injection, respectively. 4) The repeat of superovulation decreased with the number of ovulated eggs, percentage of M II and in vitro fertilization rate, than in control. But it was recovered by increasing the repeat interval.

  • PDF

고강도 인터벌 트레이닝이 D-Gal/LPS로 유도된 마우스의 급성 간 부전에 미치는 효과 (Effect of High-Intensity Interval Training on Acute Liver Failure Induced by D-Galactosamine/Lipopolysaccharide in Balb/c Mice)

  • 조진경;박수현;강현식
    • 운동과학
    • /
    • 제26권3호
    • /
    • pp.223-228
    • /
    • 2017
  • PURPOSE: This study investigated the protective role of high-intensity interval training against acute liver injury induced by D-galactosamine (D-Gal)/lipopolysaccharide (LPS). METHODS: A total of 30 male BALB/c mice aged 5-week were randomly assigned to high-intensity, interval training group (EX, n=10) or control group in cage (Non-EX, n=20) for 10 weeks. Peritoneal injection of D-Gal (700 mg/kg body weight) and LPS ($10{\mu}g/kg$ body weight) was applied to induce acute liver injury, and liver tissue was harvested 6 hours after the injection. Hematoxylin and Eosin (H&E) staining was used for liver histology. Real-time PCR was used to quantify expression of pro-inflammatory and anti-inflammatory genes in the liver. RESULTS: The liver histology showed that D-Gal/LPS treatment resulted in hepatic damage and increased number of neutrophils in conjunction with upregulation of hepatic IL-6 and $TNF-{\alpha}$ mRNAs and downregulation of hepatic $PPAR{\alpha}$ and SIRT1 mRNAs. On the other hand, the 10-week interval training resulted in a significant improvement in cardiorespiratory fitness assessed as run time to exhaustion on a treadmill. In addition, the interval training attenuated the D-Gal/LPS-induced liver damage and increased number of neutrophil in conjunction with downregulation of hepatic IL-6 and $TNF-{\alpha}$ mRNAs and upregulation of hepatic $PPAR{\alpha}$ and SIRT1 mRNAs. CONCLUSIONS: This study suggests that high-intensity interval training suppresses the D-Gal and LPS-induced acute liver damage and inflammatory responses.