• 제목/요약/키워드: Injection Control

검색결과 3,378건 처리시간 0.024초

The Effects of Secondary Fuel Injection on Combustion Oscillation

  • Shigeru Tachibana;Laurent Zimmer;Park, Gyung-Min;Takeshi Yamamoto;Ufosawa, Yoji-K;Seiji Yoshida;Kazuo Suzuki
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제22회 춘계학술대회논문집
    • /
    • pp.376-379
    • /
    • 2004
  • The purpose of this work is to develop an effective active control system for combustion instabilities of premixed combustors. For the first step, the natural modes of combustion oscillation were investigated for a methane-air premixed combustor and the controls by secondary fuel injection were examined. The main premixed flame is stabilized by a swirler with orifices for secondary injection installed on the central hub. For sensing purposes, a pressure transducer and a chemiluminescence sensor were placed on the appropriate positions. The acoustic characteristics and the source of the oscillation were analyzed by those signals. To test the controllability, two methods of actuations by secondary fuel injection were examined. One is the open loop control and the other is the closed loop control. The comparison of the reduction levels of p $_{rms}$ shows that the closed loop control with a phase-shift injection performs best in this condition.ition.n.

  • PDF

전자식 가솔린 엔진의 조절 방법에 관한 연구 (A study of electronic gasoline engine control technique)

  • 성낙원
    • 오토저널
    • /
    • 제9권5호
    • /
    • pp.66-76
    • /
    • 1987
  • The control technique for an electronic engine is studied. For this study an IBM-PC and a throttle body fuel injection system are selected. The computer controls fuel injection, spark timing, exhaust gas recirculation and idle speed. Fuel injection is adjusted either by a feed back signal of a zirconia $O_{2}$ sensor or programmed logic for starting, deceleration, warm ing up and idle modes. When a 3-way catalytic converter is used with the electronic engine control system, CO, THC, and NOx were reduced more than 90% simultaneously.

  • PDF

금주사액약침자극(金注射液藥鍼刺戟)의 항염증(抗炎症) 및 진통(鎭痛)에 관한 실험적(實驗的) 연구(硏究) (The Experimental study on the Anti-inflammatory and Analgesic Effects of Gold injection Aqua-acupuncture)

  • 홍성훈;최도영
    • Journal of Acupuncture Research
    • /
    • 제18권2호
    • /
    • pp.200-213
    • /
    • 2001
  • Objectives : This study was purposed to investigate the Anti-inflammatory and Analgesic Effects of Gold injection Aqua-acupuncture on the experimental model of rheumatoid arthritis. Methods : The experimental groups were divided into 4 groups : Control group (group injected with normal saline), J-NS (group injected with normal saline into bilateral Choksamni(ST36)), J-GS (group injected with Gold Injection into bilateral Choksamni(ST36)), and N-GS (injected with Gold Injection into the blank locus of the root of mouse tail). In addition, Diclofenac-Na as a comparative medicine is injected into bilateral Choksamni(ST36) and the blank locus of the root of mouse tail. So we measured the mice paw edema induced by Carrageenin and Dextran, the chronic rat paw edema induced by adjuvant, vascular permeability induced by Acetic acid in mice, the writhing syndrome induced by Acetic acid in mice, the heat-induced pain threshold in mice. Results : The following result have been obtained. 1. The mice paw edema induced by Carrageenin was significantly decreased in J-GS as compared with the control group. 2. The mice paw edema induced by Dextran was significantly decreased in J-GS and N-GS as compared with the control group. 3. The chronic rat paw edema induced by Adjuvant was significantly decreased in J-GS and N-GS as compared with the control group. Serum Iron content was significantly decreased in J-GS and N-GS as compared with the control group. But the effect on the Serum Copper contents has no significance statistically. 4. Vascular permeability induced by Acetic acid in mice was significantly decreased in J-GS and N-GS as compared with the control group. 5. The level of Acetic acid-induced Writhing syndrome and Heat-induced Pain Threshold in mice were all significantly decreased in J-GS and N-GS as compared with the control group. Conclusion : According to the result, gold injection aqua-acupuncture has significant anti-inflammatory and analgesic effects on the experimental model of rheumatiod arthiritis.

  • PDF

퍼지 제어 기법을 이용한 차량의 연료 제어 (Fuel Injection Control of Vehicles Using Fuzzy Control Technique)

  • 김광백;우영운;하상안
    • 한국정보통신학회논문지
    • /
    • 제11권5호
    • /
    • pp.1013-1018
    • /
    • 2007
  • 자동차의 연료분사에 관여하는 전자제어 센서에는 공기유량 센서, 흡기온도 센서, 대기압 센서, 냉각수 온도센서, 스로틀 포지션 센서, 모터 포지션 센서 등이 있다. 본 논문에서는 흡기온도 센서의 온도 변화와 공기와 연료의 혼합비율인 공연비에 대해 퍼지 제어 기법을 적용하여 차량의 연료 소비를 제어하는 방법을 제안하였다. 제안된 기법에서는 각각의 공기 유입량과 연료 분사량을 이용하여 공연비 수치를 구한 후, 공연비, 흡기온도, 최종 연료 보정량에 대해 설정된 퍼지 소속 함수와 퍼지 추론 규칙에 따라 차량 연료가 제어된다. 제어하는 방법을 제시하였다. 시뮬레이션을 통한 일반적인 차량의 연료 제어 방법과 비교 분석한 결과, 제안된 방법이 차량의 연료제어에 있어 효과적임을 확인하였다.

백일해 예방약의 백혈구 증가 인자에 관한 연구 (Leucocyte Promoting Factor of B. Pertussis Vaccine)

  • 최성배
    • 대한미생물학회지
    • /
    • 제20권1호
    • /
    • pp.109-113
    • /
    • 1985
  • It was well known that B. pertussis cells possess protective antigen, histamine sensitizing factor, heatstable and labile toxin, hemagglutinin, agglutinogen and the others. Previous reports involving above antigenic properties of B. pertussis have been carried out for several years. However, leucocyte promoting property was not yet investigated. In this report, the results of studies on the leucocytosis, particulary the lymphocytosis, produced in mice by injecting pertussis vaccine were presented. Especially leucocyte promoting property and histamine sensitizing property of B. pertussis vaccine treated at various temperatures were compared. The relationship between the leucocyte promoting property and histamine sensitizing property was investigated. Results were as follows. 1. Although leucocytosis was significantly rised in both 0.5ml injection and 0.1ml injection of pertussis vaccine than in control, at the higher dose (0.5ml injection) an elevation in white cell count was more significant. The leucocyte responce to pertussis vaccine was greater following 0.5 ml injection than following 0.1ml injection. 2. Lymphocytosis was significantly rised in both 0.5ml injection and 0.1ml injection of pertussis vaccine than in control. At higher dose (0.5ml injection), an elevation in lymphocyte count was more significant. 3. Order of elevation in differential leucocyte counts was lymphocyte, polymorphonuclear leucocyte and monocyte. 4. The leucocyte response to pertussis vaccine was 2 fold greater following intravenous injection than following subcutaneous injection. 5. Decrease leucocyte promoting activity and histamine sensitizing activity resulted from exposure to temperature above $56^{\circ}C$. Histamine sensitizing activity of pertussis vaccine treated at various temperatures paralleled leucocyte promoting activity.

  • PDF

Evaluation of Injection capabilities of a biopolymer-based grout material

  • Lee, Minhyeong;Im, Jooyoung;Chang, Ilhan;Cho, Gye-Chun
    • Geomechanics and Engineering
    • /
    • 제25권1호
    • /
    • pp.31-40
    • /
    • 2021
  • Injection grouting is one of the most common ground improvement practice to increase the strength and reduce the hydraulic conductivity of soils. Owing to the environmental concerns of conventional grout materials, such as cement-based or silicate-based materials, bio-inspired biogeotechnical approaches are considered to be new sustainable and environmentally friendly ground improvement methods. Biopolymers, which are excretory products from living organisms, have been shown to significantly reduce the hydraulic conductivity via pore-clogging and increase the strength of soils. To study the practical application of biopolymers for seepage and ground water control, in this study, we explored the injection capabilities of biopolymer-based grout materials in both linear aperture and particulate media (i.e., sand and glassbeads) considering different injection pressures, biopolymer concentrations, and flow channel geometries. The hydraulic conductivity control of a biopolymer-based grout material was evaluated after injection into sandy soil under confined boundary conditions. The results showed that the performance of xanthan gum injection was mainly affected by the injection pressure and pore geometry (e.g., porosity) inside the soil. Additionally, with an increase in the xanthan gum concentration, the injection efficiency diminished while the hydraulic conductivity reduction efficiency enhanced significantly. The results of this study provide the potential capabilities of injection grouting to be performed with biopolymer-based materials for field application.

Morphine 정주를 이용한 술후 통증 조절시 진토제 일회 정주의 지속적 항오심 및 항구토 효과 (Continuous Antiemetic Effects of Single Intravenous Injection of Antiemetics during Postoperative Pain Control with Morphine)

  • 최기선;안치홍;박성식;임동건;백운이;박진웅
    • The Korean Journal of Pain
    • /
    • 제10권1호
    • /
    • pp.42-47
    • /
    • 1997
  • Background : This study was designed to evaluate the continuous effects of single intravenous injection of antiemetics on nausea and vomiting during continuous morphine injection for postoperative pain control. Methods : Prior to the study, we divided patients into two major groups according to the type of surgery performed intra-abdominal(Open: O) and non intra-abdominal(Close: C). When patients regained orientation after routine general anesthesia, enflurane-$O_2-N_2O$, we injected bolus dose of morphine and started continuous injection of morphine for postoperative pain control(Group I; Control). After bolus injection and just before continuous injection, we injected single dose of droperidol(Group II) or ondansetron(Group III). Mean arterial blood pressure, heart rate, pain score and symptom-therapy score were checked at 10 minutes, 4, 8, 16, 24, 36 hours after continuous morphine injection. Results : The pain score of group III was lower than group II(10 min.) and group I(24, 36 hours) in the open group. Symptom-therapy score of group III(10 min., 4, 24 hours) and group II(10 min.) were lower than group I in the open group. In the close group, symptom-therapy score of group III(8 hours) was lower than group I. Conclusions : Single intravenous injection of antiemetics have a tendency of lowering symptom-therapy score for 36 hours in spite of their relatively short elimination half-life.

  • PDF

Effects of warmed carrier fluid on nefopam injection-induced pain

  • Cho, Hyung Rae;Kim, Seon Hwan;Kim, Jin A;Min, Jin Hye;Lee, Yong Kyung
    • The Korean Journal of Pain
    • /
    • 제31권2호
    • /
    • pp.102-108
    • /
    • 2018
  • Background: Nefopam is a non-opioid, non-steroidal analgesic drug with fewer adverse effects than narcotic analgesics and nonsteroidal anti-inflammatory drugs, and is widely used for postoperative pain control. Because nefopam sometimes causes side effects such as nausea, vomiting, somnolence, hyperhidrosis and injection-related pain, manufacturers are advised to infuse it slowly, over a duration of 15 minutes. Nevertheless, pain at the injection site is very common. Therefore, we investigated the effect of warmed carrier fluid on nefopam injection-induced pain. Methods: A total of 48 patients were randomly selected and allocated to either a control or a warming group. Warming was performed by diluting 40 mg of nefopam in 100 ml of normal saline heated to $31-32^{\circ}C$ using two fluid warmers. The control group was administered 40 mg of nefopam dissolved in 100 ml of normal saline stored at room temperature ($21-22^{\circ}C$) through the fluid warmers, but the fluid warmers were not activated. Results: The pain intensity was lower in the warming group than in the control group (P < 0.001). The pain severity and tolerance measurements also showed statistically significant differences between groups (P < 0.001). In the analysis of vital signs before and after the injection, the mean blood pressure after the injection differed significantly between the groups (P = 0.005), but the heart rate did not. The incidence of hypertension also showed a significant difference between groups (P = 0.017). Conclusions: Use of warmed carrier fluid for nefopam injection decreased injection-induced pain compared to mildly cool carrier fluid.

서보모터를 이용한 유압 하이브리드식 사출성형기의 공정시간 및 절전효과에 관한 연구 (A Study on Cycle Time and Power Saving Effect of a Hydraulic Hybrid Injection Molding Machine using a Servo Motor)

  • 윤홍식;김성동
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권3호
    • /
    • pp.15-25
    • /
    • 2020
  • The cycle time and power saving effect of a hydraulic hybrid injection molding machine using a servo motor are considered in this paper. In order to verify control characteristics, such as pressure and speed, experiments were performed with the hydraulic hybrid injection molding machine, clamping force of 110 ton. The power consumption and production cycle time of a conventional hydraulic injection molding machine were measured to compare its performances with the hydraulic hybrid injection molding machine. An injection molding machine with a clamping force of 1300 ton was used as the conventional machine, the hybrid machine was implemented by replacing its induction motors with servo motors. In the remodeled hybrid machine, experiments were performed to investigate how the displacement of the mold clamping pump affects the power consumption and production cycle time. The results showed that the production cycle time of the hybrid injection molding is similar to a conventional hydraulic injection molding machine but with a significant energy saving of about 40%.

A Study on the Behavior Characteristics of Diesel Spray by Using a High Pressure Injection System with Common Rail Apparatus

  • Yeom, Jeong-Kuk;Hajime Fujimoto
    • Journal of Mechanical Science and Technology
    • /
    • 제17권9호
    • /
    • pp.1371-1379
    • /
    • 2003
  • The effects of change in injection pressure on spray structure in high temperature and pressure field have been investigated. The analysis of liquid and vapor phases of injected fuel is important for emissions control of diesel engines. Therefore, this work examines the evaporating spray structure using a constant volume vessel. The injection pressure is selected as the experimental parameter, is changed from 22 MPa to 112 MPa using a high pressure injection system (ECD-U2). Also, we conducted simulation study by modified KIVA-II code. The results of simulation study are compared with experimental results. The images of liquid and vapor phase for free spray were simultaneously taken by exciplex fluorescence method. As experimental results, the vapor concentration of injected fuel is leaner due to the increase of atomization in the case of the high injection pressure than in that of the low injection pressure. The calculated results obtained by modified KIVA-II code show good agreements with experimental results.